Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Sci Rep ; 14(1): 13262, 2024 06 10.
Article in English | MEDLINE | ID: mdl-38858417

ABSTRACT

The purpose of this study was to evaluate the fatigue survival of 5Y-PSZ zirconia infiltrated with an experimental glass and bonded onto dentin analogues. Disc-shaped specimens of a 5Y-PSZ (Katana UTML Kuraray Noritake) were cemented onto dentin analogs (NEMA G10) and divided into four groups (n = 15): Zctrl Group (control, without infiltration); Zglz Group (Glaze, compression surface); Zinf-comp Group (Experimental Glass, compression surface); Zinf-tens Group (Experimental Glass, tension surface). Surface treatments were varied. Cyclic fatigue loading, oblique transillumination, stereomicroscope examination, and scanning electron microscopy were performed. Fatigue data were analyzed (failure load and number of cycles) using survival analysis (Kaplan-Meier and Log-Rank Mantel-Cox). There was no statistically significant difference in fatigue survival between the Zglz, Zctrl, and Zinf-comp groups. The Zinf-tens group presented a significantly higher failure load when compared to the other groups and exhibited a different failure mode. The experimental glass effectively infiltrated the zirconia, enhancing structural reliability, altering the failure mode, and improving load-bearing capacity over more cycles, particularly in the group where the glass was infiltrated into the tensile surface of the zirconia. Glass infiltration into 5Y-PSZ zirconia significantly enhanced structural reliability and the ability to withstand loads over an increased number of cycles. This approach has the potential to increase the durability of zirconia restorations, reducing the need for replacements and save time and resources, promoting efficiency in clinical practice.


Subject(s)
Dentin , Glass , Materials Testing , Zirconium , Zirconium/chemistry , Glass/chemistry , Dentin/chemistry , Humans , Microscopy, Electron, Scanning , Surface Properties
2.
Braz Oral Res ; 38: e053, 2024.
Article in English | MEDLINE | ID: mdl-38922213

ABSTRACT

To evaluate the effect of acidic challenge on erosion depth and topographic characteristics of different materials used as occlusal sealants. Two hundred specimens of five sealant materials (Fuji IX, Ketac Molar, Fuji II, Equia and Clinpro) and forty bovine teeth enamel samples (control) were prepared and exposed to acidic challenge. The specimens were immersed in four different solutions (orange juice, coke drink, citric acid or distilled water) under mildly shaken conditions for 3 days. The erosion depth profiles were measured using a profilometer and Scanning Electron Microscope (SEM). Two-way ANOVA with Tukey post-hoc test was performed to evaluate the interactions. Sealant material and acidic challenge had significant effects on erosion depth. Among the materials, Fuji II presented the highest mean of erosion depth after immersion in orange juice, coke drink, and citric acid. All materials groups presented higher erosion depth values after immersion in the citric acid solution, except Clinpro. Bovine enamel presented higher erosion depth values compared to all materials when submitted to erosive challenge. Sealant materials submitted to the acidic challenge presented different degrees of erosion and topographic modification; however, they are less susceptible to erosion than bovine teeth enamel.


Subject(s)
Citric Acid , Dental Enamel , Materials Testing , Microscopy, Electron, Scanning , Pit and Fissure Sealants , Surface Properties , Tooth Erosion , Cattle , Animals , Tooth Erosion/prevention & control , Tooth Erosion/chemically induced , Dental Enamel/drug effects , Pit and Fissure Sealants/chemistry , Analysis of Variance , Time Factors , Surface Properties/drug effects , Glass Ionomer Cements/chemistry , Glass Ionomer Cements/therapeutic use , Reproducibility of Results , Carbonated Beverages/adverse effects , Reference Values , Hydrogen-Ion Concentration , Composite Resins/chemistry
3.
J Mech Behav Biomed Mater ; 150: 106338, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38159495

ABSTRACT

The aim of this study was to mechanically characterize through flexural fatigue test two CAD-CAM glass-ceramics according to distinct surface etching protocols. To do so, feldspathic (FELD) and lithium disilicate (LD) glass ceramics were subjected to different surface treatments: (1) control - no treatment (Ctrl); (2) conventional protocol etching with 5% hydrofluoric acid followed by silane coupling agent application (HF + SIL; Monobond N, Ivoclar); or (3) using a self-etching ceramic primer (E&P; Monobond Etch & Prime, Ivoclar). Ceramic discs (N = 120; Ø = 12 mm; thickness = 1.2 mm) were produced from CAD-CAM blocks, with 60 being from FELD (VITABLOCS Mark II, Vita Zahnfabrik) and 60 from LD (IPS e.max CAD, Ivoclar). Next, 20 disks of each ceramic were allocated into three groups: Ctrl, HF + SIL, or E&P. Surface roughness data were collected on all samples before and after surface treatments (except for Ctrl). Cyclic fatigue (n = 15) biaxial flexural strength tests were performed by the piston-on-three-balls geometry (ISO 6872) considering the test parameters established from a monotonic test (n = 5). The monotonic test was carried out at a 1 mm/min loading rate and 500 kgf loading cell until fracture to obtain the failure data. The cyclic fatigue test was executed underwater at a frequency up to 20 Hz, with the first stress being 25% of the monotonic test for 5000 cycles, followed by increments of 5% of the monotonic test at each step of 10,000 cycles until failure (fracture). Complementary fractography, topography and Atomic Force Microscopy (AFM) analyses were performed. Characteristic Fatigue Strength (CFS) and Weibull modulus were analyzed by Weibull analysis using the fatigue test data. Roughness and complementary analysis data were analyzed by one-way ANOVA. The statistical results exhibited similar CFS among Ctrl, HF + SIL and E&P for both glass-ceramics. The survival analysis corroborates the findings, however the Weibull modulus pointed out superior structural reliability of FELD treated with the E&P group compared to HF + SIL. According to the complementary analyses, HF + SIL exhibited a higher surface area than E&P and Ctrl for FELD (p = 0.001). Roughness showed statistically significant differences among conditions for FELD (E&P < Ctrl = HF + SIL; p < 0.05) and no difference for LD (p > 0.05). Therefore, the CFS were not influenced by any condition evaluated for FELD and LD glass-ceramics; however, superior structural reliability (higher Weibull modulus) for the feldspathic ceramic treated with the E&P was observed.


Subject(s)
Dental Bonding , Silanes , Surface Properties , Silanes/chemistry , Hydrofluoric Acid , Reproducibility of Results , Materials Testing , Acid Etching, Dental , Ceramics/chemistry , Dental Porcelain , Dental Stress Analysis , Resin Cements
4.
Clin Oral Investig ; 27(9): 5539-5548, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37490118

ABSTRACT

OBJECTIVE: To evaluate the effects of cusp inclination of the prosthetic preparation's occlusal surface and type of restorative material on the fatigue behavior, failure mode, and stress distribution of occlusal veneers. MATERIALS AND METHODS: Glass fiber-reinforced epoxy resin prosthetic preparations for occlusal veneers with three different occlusal surface cusp inclination degrees (0°, 15°, and 30°) were produced and assigned into six testing groups (n = 11) according to the cusp inclination (0°, 15°, or 30°) and type of restorative material (lithium disilicate-LD or resin composite-RC). Despite different substrate preparation cusp inclination degrees, the restorations were designed maintaining 30° inclination between the cusps at the occlusal surface and a thickness of 0.7 mm at the central groove region of the restorations to be machined in a CAD/CAM system. After cementation, the specimens were stored for about 7 days (under water at 37 °C), and subsequently submitted to a load to failure test (n = 2) and an intermittent cyclic fatigue test (n = 9) (initial load: 100 N; step size: 50 N; cycles/step: 10,000; loading frequency: 20 Hz; loading piston: 6-mm-diameter stainless steel) until observing cracks. The data were analyzed by two-way ANOVA, Kaplan-Meier, and Mantel-Cox post hoc tests. Finite element analysis (FEA) and fractographic analyses were performed. RESULTS: The fatigue performance of LD and RC occlusal veneers was evaluated based on different prosthetic preparation cusp inclinations. The 0° inclination showed the best fatigue performance for both materials (LD: 944N, RC: 861N), while the 15° and 30° inclinations had lower values (LD: 800N and 533N, RC: 739N and 717N, respectively). The study also found that for a 0° inclination, LD occlusal veneers performed better than RC ones (LD: 944 N > RC: 861N), while for a 30° inclination, RC occlusal veneers had better fatigue performance than LD ones (LD: 533N < RC: 717N). No significant difference was observed between the materials for a 15° inclination (LD: 800N = RC: 739N). The FEA results showed a higher tensile stress concentration on lithium disilicate than on resin composite occlusal veneers. All lithium disilicate occlusal veneers showed radial crack failures, while resin composite occlusal veneers showed Hertzian cone cracks and radial cracks combined. CONCLUSION: Considering mechanical perspective only, RC occlusal veneers should be indicated when prosthetic preparation cusps inclinations are 30°. When 0° prosthetic preparation cusps inclinations are observed, LD occlusal veneers will behave mechanically better. When a 15° cusp inclination is preserved, both restorative materials behave similarly.


Subject(s)
Ceramics , Dental Porcelain , Materials Testing , Dental Stress Analysis , Composite Resins , Computer-Aided Design , Dental Restoration Failure , Surface Properties
5.
J Mech Behav Biomed Mater ; 144: 105975, 2023 08.
Article in English | MEDLINE | ID: mdl-37379673

ABSTRACT

OBJECTIVE: To summarize the existing scientific evidence on the effect of distinct intraoral (IOS) and extraoral (EOS) scanners in terms of their accuracy for image acquisition and the marginal/internal adaptation of indirect restorations. METHODS: The protocol of this scoping review is available online (https://osf.io/cwua7/). A structured search, with no date restriction, was performed in LILACS, MEDLINE via Pubmed, EMBASE, Web of Science, and Scopus, for articles written in English. The inclusion criteria were studies that considered at least two scanners, regardless of method (intra or extraoral), for the production of tooth-supported restorations. Two independent and blinded researchers screened the studies, collected and analyzed the data descriptively. RESULTS: 103 studies were included (55 on marginal/internal adaptation, 33 on accuracy, 5 on both outcomes, and 10 reviews). Most of them, shown clinically acceptable adaptation (<120 µm). Factors commonly related to the performance of scanners are: use of anti-reflection powders, method of image acquisition, and restoration/tooth characteristics. The need of anti-reflection powders was controversial. Different scanning principles seems to result on similar performance; IOS that combine them could be promising. The most explored systems were Omnicam - IOS, and inEos X5 - EOS, which showed similar performance on marginal/internal adaptation. Scarce studies explored the performance of EOS systems, especially in terms of accuracy. Different restoration designs as single-unit seemed not to modify the performance of scanners. Limited information is available regarding the planned cement space, restorative material and design (multi-unit restorations), as also techniques to measure adaptation. CONCLUSIONS: Digital scanners are valid approaches to obtain accurate impressions resulting in clinically acceptable restorations. Systems that uses combined principles of image acquisition seems promising for optimal performance. Based on high discrepancy, the quality of evaluated evidence is low, and well-designed studies are still encouraged, especially considering validated IOS/EOS as a control comparison condition.


Subject(s)
Computer-Aided Design , Tooth , Powders , Dental Prosthesis Design
6.
J Mech Behav Biomed Mater ; 142: 105819, 2023 06.
Article in English | MEDLINE | ID: mdl-37062098

ABSTRACT

OBJECTIVE: To evaluate the influence of intaglio ceramic surface treatments, resin cement viscosities, and storage regimens on the microshear bond strength of lithium disilicate ceramic. In addition, to investigate the dynamic viscosity of the resin-based luting agents. MATERIALS AND METHODS: Ceramic slices were randomly allocated into eight groups (n = 19) considering three factors: ceramic surface treatment (hydrofluoric acid followed by silane, HF; or self-etching ceramic primer, E&P), resin cement viscosity (high, HIGH; or low, LOW) and storage regimen (baseline or aging). Surface treatments were performed, resin cement cylinders were built and microshear bond strength tests (µSBS, wire-loop method, speed: 1.0 mm/min) were run according to the storage factor. Failure mode, topographic and dynamic viscosity (37 °C; shear rate of 1.0-100 s-1) of resin cement components (base, high and low catalyst) were also performed. RESULTS: Resin cement viscosity and the association among ceramic surface treatment, resin cement viscosity, and storage regimen were statistically significant factors (p < 0.05). Worse behavior was identified for the E&P_HIGH group compared to the E&P_LOW and HF_LOW in the baseline condition. After aging, the HF_HIGH group (16.78 MPa) presented the worst result among the aged groups (21.44-25.25 MPa). Most of the failures were adhesive. Surface micrographs revealed a distinct pattern after etching, more aggressive by HF and milder by E&P. High viscosity catalyst is 5.3 and 8.5-fold more viscous than the base and low viscosity catalyst, respectively (high > base > low). CONCLUSION: Differences in filler content can impact the resin viscosity of the material (more fillers increase the viscosity), which in turn can influence the bond strength of a lithium disilicate ceramic, depending on the surface treatment and storage regimen.


Subject(s)
Dental Bonding , Resin Cements , Resin Cements/chemistry , Viscosity , Surface Properties , Materials Testing , Ceramics , Dental Porcelain , Hydrofluoric Acid , Silanes
7.
J Mech Behav Biomed Mater ; 140: 105746, 2023 04.
Article in English | MEDLINE | ID: mdl-36878081

ABSTRACT

OBJECTIVE: To characterize the effect of the occlusal contact region on the mechanical fatigue performance and on the fracture region of monolithic lithium disilicate ceramic crowns. MATERIALS AND METHODS: Monolithic lithium disilicate ceramic crowns were machined in a CAD/CAM system and adhesively luted onto glass-fiber reinforced epoxy resin preparations with resin cement. The crowns were divided into three groups (n = 16) according to load application region (cusp tip: restricted to cusp tips; cusp plane: restricted to cuspal inclined plane; or mixed: associating tip cusp and cuspal inclined plane). The specimens were submitted to a cyclic fatigue test (initial load: 200 N; step-size: 100 N; cycles/step: 20,000; loading frequency: 20 Hz; load applicator: 6 mm or 40 mm diameter stainless steel) until observing cracks (1st outcome) and fracture (2nd outcome). The data were analyzed by the Kaplan-Meier + Mantel-Cox post-hoc tests for both outcomes (cracks and fracture). Finite element analysis (FEA), occlusal contact region, contact radii measurements, and fractographic analyzes were performed. RESULTS: The mixed group presented worse fatigue mechanical behavior (550 N / 85.000 cycles) compared to the cuspal inclined plane group (656 N / 111,250 cycles) (p < 0.05) for the first crack outcome, while the cusp tip group was similar to both groups (588 N / 97,500 cycles) (p > 0.05). The mixed group had the worst fatigue behavior (1413 N / 253,029 cycles) in relation to the other groups (Cusp tip: 1644 N / 293,312 cycles; Cuspal inclined plane: 1631 N / 295,174 cycles) considering the crown fracture outcome (p < 0.05). FEA showed higher tensile stress concentration areas just below the load application region. In addition, loading on the cuspal inclined plane induced a higher tensile stress concentration in the groove region. The most prevalent type of crown fracture was the wall fracture. Groove fracture was observed in 50% of the loading specimens exclusively on the cuspal inclined plane. CONCLUSION: Load application on distinct occlusal contact regions affects the stress distribution pattern and consequently the mechanical fatigue performance and fracture region of the monolithic lithium disilicate ceramic crowns. A combination of loading at distinct regions is recommended to promote better evaluation of the fatigue behavior of a restored set.


Subject(s)
Fractures, Bone , Tooth Fractures , Humans , Ceramics , Materials Testing , Dental Porcelain , Crowns , Computer-Aided Design , Dental Stress Analysis , Dental Restoration Failure , Surface Properties
8.
J Mech Behav Biomed Mater ; 139: 105667, 2023 03.
Article in English | MEDLINE | ID: mdl-36657192

ABSTRACT

This study aimed to evaluate the influence of ceramic surface treatments, resin cement viscosities, and storage regimens on the fatigue performance of bonded glass-ceramics (lithium disilicate, LD; feldspathic, FEL). Ceramic discs (Ø = 10 mm; thickness = 1.5 mm) were allocated into eight groups per ceramic (n = 15), considering three factors: "ceramic surface treatment" in two levels - 5% hydrofluoric acid etching and silane-based coupling agent application (HF), or self-etching ceramic primer (E&P); "resin cement viscosity" in two levels - in high or low viscosity; and "storage regimen" in two levels - baseline, 24 h to 5 days; or aging, 180 days + 25,000 thermal cycles. Adhesive luting was performed onto glass fiber-reinforced epoxy resin discs (Ø = 10 mm; thickness = 2 mm) and the bonded assemblies were subjected to cyclic fatigue tests: initial load = 200 N; step-size = 25 N (FEL) and 50 N (LD); 10,000 cycles/step; 20 Hz. Scanning electron microscopy (SEM) inspections were performed. Regarding the LD ceramic, the fatigue behavior was reduced after aging for HF_HIGH and E&P_LOW conditions, while stable performance was observed for HF_LOW and E&P_HIGH. Regarding the FEL results, aging negatively affected HF_HIGH, E&P_HIGH, and E&P_LOW, being that only the HF_LOW condition presented a stable behavior. The failure initiated from defects on the etched surface of the ceramics, where the cross-sectional analysis commonly revealed unfilled areas. Long-term aging might induce a decrease in mechanical behavior. The 'ceramic microstructure/surface conditioning/resin cement viscosity relationships' modulate the fatigue performance of lithium disilicate and feldspathic glass-ceramics.


Subject(s)
Dental Bonding , Resin Cements , Surface Properties , Viscosity , Cross-Sectional Studies , Materials Testing , Acid Etching, Dental/methods , Hydrofluoric Acid , Ceramics , Dental Porcelain , Dental Stress Analysis
9.
J Mech Behav Biomed Mater ; 138: 105597, 2023 02.
Article in English | MEDLINE | ID: mdl-36459706

ABSTRACT

The aim of the study was to evaluate whether the region (internal or external) of the CAD/CAM block influences the mechanical performance of restorative materials. Blocks of different CAD/CAM materials (Composites: KAV - Katana Avencia; LULT - LULT Ultimate; Ceramics: ENAM - Vita Enamic; NICE - N!CE; EMP - IPS Empress CAD; VMII - Vita Mark II; EMAX - IPS e.max CAD) were selected, and direct resin composite blocks (APX - Clearfil AP-X; FSUP - Filtek Supreme) were built using the incremental technique on a mold from one of the CAD/CAM blocks. All blocks were sectioned into bar-shaped specimens (1 × 1 × 14 mm), which were separated into two groups according to the region of the block (inside or outside). 3-point bending tests were performed following ISO 6872:2015 and flexural strength data were analyzed using one-way ANOVA and Bonferroni post-hoc tests (p < 0.05). Weibull module and characteristic strength were also calculated. In general, the mean flexural strength values were not statistically different (p > 0.05) between the inside and outside regions of each material, except for LULT (inside > outside) and EMAX (outside > inside). Comparing the materials, a similar strength (only discrete variations) was observed for inside, outside or merged (inside and outside data assembled together) regions: EMAX > KAV = LULT > NICE = APX > EMP = ENAM = VMII ≥ FSUP (merged condition). Characteristic strength at 63.2% failure probability and at 5% failure probability generally corroborates such observations. There were no statistical differences for Weibull module data (inside, outside, or merged), except for KAV and NICE (outside > inside). Thus, the region from where the restoration is milled within the CAD/CAM block generally does not influence the mechanical performance hereof (flexural strength, failure probability, risk of premature failures, and mechanical reliability) of the material, except for LULT and EMAX.


Subject(s)
Ceramics , Flexural Strength , Materials Testing , Reproducibility of Results , Ceramics/chemistry , Computer-Aided Design , Composite Resins , Surface Properties , Dental Porcelain
10.
J Mech Behav Biomed Mater ; 138: 105607, 2023 02.
Article in English | MEDLINE | ID: mdl-36549251

ABSTRACT

The characteristics of dental ceramics have been extensively studied over the years to provide highly qualified materials for use in prosthetic restorations. The ability to adhere to dental substrates, outstanding aesthetics (translucency, color, and substrate masking ability) and improved mechanical properties provide these materials with optical features and high strength to withstand masticatory stimuli. Different classifications are adopted, and it is generally considered that glass-ceramics have better optical characteristics due to the high glass content, and polycrystalline ceramics have superior strength favored by their densified and organized crystals, hampering crack growth. This knowledge was largely built-up during years of scientific research through different testing methodologies, but mainly employing static loads. It is important to not only take into account the intensity of loads that these materials will be exposed to, but also the effect of the intermittence of cyclic load application leading to mechanical fatigue and the influence of factors related to the crack origin and their propagation under this condition. Furthermore, the bonding surface of ceramic restorations requires surface treatments that improve the bond strength to luting agents; however, these treatments require caution because of their potential to produce defects and affect the structural behavior. Moreover, ceramic restorations often require internal adjustments for proper seating or external adjustments for fitting the occlusal contact with the antagonist. In this sense, finishing/polishing protocols may alter the defect population, as luting agents may also interact by filling in the superficial defects on the restoration intaglio surface. Thus, the balance among all these factors will define the performance of a restorative setup, as well as the posterior exposure to the humid environment and the masticatory stimuli (cyclical loading), which may favor developing slow and subcritical growth of cracks in ceramic materials and the degradation of the bond interface. Therefore, it is essential that the concepts which explain the fatigue mechanism are understood, as well as the crack propagation and failure patterns of restorative ceramic materials.


Subject(s)
Ceramics , Glass , Materials Testing , Ceramics/chemistry , Dental Cements , Dentistry , Dental Porcelain , Surface Properties , Computer-Aided Design , Dental Stress Analysis , Dental Restoration Failure
11.
Dent Mater ; 38(12): 1910-1920, 2022 12.
Article in English | MEDLINE | ID: mdl-36229280

ABSTRACT

OBJECTIVE: To explore the effect of resin cement viscosities on the shear bond strength under static and fatigue load of lithium disilicate and dentin substrates. METHODS: Bonded tri-layer samples (lithium disilicate ceramic cylinder, resin cement, and substrate - ceramic or dentin) was performed considering 2 factors (n = 15): "resin cement viscosity" (high, HV; or low, LV) and "loading mode" (static, s-SBS; or fatigue shear bond strength, f-SBS). The specimens were subjected to s-SBS (1 mm/min, 1 kN load cell) and f-SBS (cyclic fatigue, initial load: 10 N; step-size: 5 N; 10,000 cycles/step; underwater). Failure mode, topography, and finite element analysis (FEA) were performed. RESULTS: The resin cement viscosity did not influence the s-SBS and f-SBS of lithium disilicate substrate; however, it affected the bond strength to dentin, with HV presenting the worst fatigue behavior (f-SBS = 6.89 MPa). Cyclic loading in shear testing induced a notorious detrimental effect with a relevant decrease (16-56 %) in bond strength and survival rates, except for dentin substrate and LV. Most failures were adhesive. A distinct pattern comparing the disilicate and dentin was identified and FEA demonstrated that there was a stress concentration on the top of the cement layer. SIGNIFICANCE: Cyclic fatigue loading in shear testing has detrimental effects on the adhesive behavior and survival probabilities of bonded lithium disilicate sets, regardless of resin cement viscosity. In contrast, resin cement viscosity affects the bond strength and the survival rates of dentin substrate submitted to cyclic loading mode, in which a low viscosity results in better performance.


Subject(s)
Dental Bonding , Resin Cements , Resin Cements/chemistry , Viscosity , Dental Bonding/methods , Dental Stress Analysis , Dental Cements , Materials Testing , Dental Porcelain/chemistry , Ceramics/chemistry , Shear Strength , Dentin , Surface Properties
12.
J Mech Behav Biomed Mater ; 135: 105455, 2022 11.
Article in English | MEDLINE | ID: mdl-36148725

ABSTRACT

This study compared the flexural strength under monotonic (static - sσ) and cyclic load application (fatigue - fσ), hardness (H) and fracture toughness (KIC) of different layers of a multi-layered zirconia (IPS e.max ZirCAD MT Multi, Ivoclar). Each layer was sectioned, classified into three groups according to yttria content (4-YSZ, 4/5-YSZ and 5-YSZ), and shaped on samples for flexural strength and fracture toughness tests (bars: 1.0 × 1.0 × 11 mm); and Vickers hardness test (plates: 1.5 × 4.0 × 5.0 mm). Flexural strength under monotonic load application (sσ; n = 10) was obtained through two different devices (three-point-bending and ball-in-hole device) and fatigue flexural strength (fσ; n = 15; initial load: 10 N; step-size: 5 N; 10,000 cycles/step) was assessed using a ball-in-hole device under cyclic load application. Vickers hardness test (n = 5), fracture toughness test (n = 10), and additional analyzes (Finite Element Analysis - FEA, Energy-dispersive X-ray spectroscopy - EDS and Scanning Electron Microscopy - SEM) were also performed. No differences were found between the different devices in the monotonic flexural strength test, and FEA showed similar tensile stress distribution for the two devices. 4-YSZ showed higher values of flexural strength under monotonic and cyclic load application modes (sσ = 1114.73 MPa; fσ = 798.84 MPa), and fracture toughness (KIC = 3.90 MPa√m). 4/5-YSZ had an intermediate sσ; however, fσ was similar to 5-YSZ (404.00-429.36 MPa) and KIC similar to 4-YSZ (KIC = 3.66 MPa√m). No statistical differences were found for hardness and Weibull modulus for fatigue flexural strength data. The amount of yttria in the layer compositions increased from 4-YSZ to 5-YSZ, and larger zirconia crystals were observed in the topographic images of 5-YSZ. Failures in the flexural strength and toughness tests started from the face subjected to tensile stress. Different layers of the multi-layered zirconia blank presented distinct mechanical properties. 4-YSZ (cervical layer) presented the highest flexural strength under monotonic and cyclic loads (fatigue), and higher fracture toughness even similar to the transition layer (4/5-YSZ). Hardness was similar between the layers. The ball-in-hole device performed similarly to the three-point bending device and can be used as an alternative to the traditional method.


Subject(s)
Flexural Strength , Zirconium , Ceramics/chemistry , Dental Porcelain , Hardness , Humans , Materials Testing , Surface Properties , Yttrium , Zirconium/chemistry
13.
J Mech Behav Biomed Mater ; 134: 105417, 2022 10.
Article in English | MEDLINE | ID: mdl-36049370

ABSTRACT

OBJECTIVES: To evaluate the effect of in-lab simulation of CAD/CAM grinding and intaglio surface treatments on the surface characteristics (topography and roughness) and fatigue behavior of adhesively luted 4YSZ simplified restorations. METHODS: Ceramic discs (Ø = 10 mm, thickness = 1 mm) were randomly allocated into 6 groups considering: "In-lab simulation of CAD/CAM grinding" (ground or polished) and "intaglio surface treatments": Ctrl (without surface treatment), AlOx (aluminum oxide air abrasion) or GLZ (glaze spray application). The surface roughness of all samples was measured, the treated discs received a ceramic primer, were luted with resin cement onto a dentin analogue material (woven glass-reinforced epoxy resin) and tested under a cyclic fatigue test (step-stress approach, n = 15; 1.4 Hz, 10,000 cycles/step, step-size of 100N starting at 200N until failure). A complementary analysis was performed to corroborate the findings in the fatigue test that the glaze fill defects increase the mechanical properties of the ceramic. To do so, bars (n= 10; 1.0 × 1.0 × 12 mm; considering the groups: N-ID: non-indented; ID: indented; ID-GLZ: indented plus glaze spray application) were indented in a vickers hardness tester to produce a crack pattern, treated with glaze or not, and then submitted to flexural strength tests (FS). Fractographic and topographic analysis were performed. RESULTS: In-lab simulation of CAD/CAM grinding decreased the fatigue failure load of the 4YSZ ceramic when comparing polished and ground groups, regardless of surface treatment. GLZ induced better fatigue performance compared to the air abrasion, regardless of the grinding condition (ground or polished surface). The results of the flexural strength test corroborated the findings in the fatigue test, as the ID-GLZ group presented superior FS than the ID group, however both had inferior FS than N-ID. There is an inverse association between roughness and fatigue failure load, as the higher the surface roughness, the lower the fatigue failure load. Failures in the fatigue and flexural strength tests started from the face subjected to tensile stresses. CONCLUSION: In-lab simulation of CAD/CAM grinding had a detrimental effect on the fatigue behavior of 4YSZ and glaze spray induced better 4YSZ performance compared to the air abrasion. The intaglio surface treatments differently influenced the 4YSZ fatigue performance, however, only glaze spray can reverse the damage caused by the grinding.


Subject(s)
Ceramics , Computer-Aided Design , Dental Porcelain , Dental Stress Analysis , Materials Testing , Surface Properties , Weight-Bearing , Zirconium
14.
J Mech Behav Biomed Mater ; 134: 105407, 2022 10.
Article in English | MEDLINE | ID: mdl-35988524

ABSTRACT

OBJECTIVES: To evaluate the fatigue failure load (FFL), cycles for fatigue failure (CFF) and survival rates of different occlusal thicknesses of resin composite simplified crowns with internal adjustments (IA) or without as control (C). METHODS: 30 monolithic simplified crowns of CAD/CAM resin composite (Tetric CAD, Ivoclar) were milled in three different occlusal thicknesses (0.5 mm, 1.0 mm, and 1.5 mm). Half of the crowns were submitted to restricted adjustment with diamond burs on the crown's inner surface and half remained milled without internal adjustment. The samples were treated and adhesively luted onto a prosthetic preparation made of epoxy resin reinforced by glass-fiber substrate. The sets were subjected to a fatigue test (cyclic fatigue: initial load of 200 N; step-size of 50 N; 10,000 cycles/step; 20 Hz; maximum load: 2800 N).Microscopic analysis of tested representative samples was performed. The fatigue data were statistically analyzed (α= 0.05) and the micrograpic images were qualitatively evaluated. RESULTS: All specimens from groups 1.0C and 1.5C survived the cyclic loads, while all 0.5C samples failed during the test. The 1.0IA and 1.5IA crowns showed no statistical difference for FFL (2530 N= 2670 N) and CFF (471,000 cycles= 499,000 cycles) between them, and they were both statistically superior to the 0.5IA (FFL= 1812.50 N; CFF= 327,500 cycles). The 1.0 mm and 1.5 mm crowns presented superior fatigue behavior (2530 N-2800 N) compared to the 0.5 mm crowns (1812 N-2140 N), whether internal adjustment was performed or not. A statistically significant difference was found for FFL and CFF of 0.5 mm crowns with and without internal adjustment, with a deleterious impact of the adjustment for both parameters (FFL and CFF: 0.5C > 0.5IA). SIGNIFICANCE: Resin composite milled crowns can bear high cyclic fatigue loads despite thickness, although thicker crowns had better mechanical behavior; however, the internal adjustment in the composite resin crown leads to a detrimental effect on its fatigue behavior, which presents a risk of mechanical failure due to premature fatigue.


Subject(s)
Ceramics , Composite Resins , Computer-Aided Design , Dental Porcelain , Dental Restoration Failure , Dental Stress Analysis , Materials Testing , Surface Properties , Weight-Bearing
15.
J Mech Behav Biomed Mater ; 134: 105398, 2022 10.
Article in English | MEDLINE | ID: mdl-35961241

ABSTRACT

This study evaluated the influence of the piston material (glass fiber-reinforced epoxy resin or stainless steel) and the piston tip diameter (6 or 40 mm) on the fatigue mechanical behavior, failure mode, and stress distribution of feldspathic ceramic simplified restorations. Pistons were machined in glass fiber-reinforced epoxy resin (ER) and in stainless steel (SS), with active tips simulating the curvature radius of 6- or 40-mm diameter spheres. A total of sixty (N= 60) feldspathic ceramic discs (Ø= 10 mm; thickness= 1.0 mm) were adhesively luted onto supporting substrate discs (Ø= 10 mm; thickness= 2.5 mm) and allocated into 4 groups (n= 15) according to the piston used for fatigue testing: ER_6, ER_40, SS_6, SS_40. Afterwards, the specimens were submitted to the cyclic fatigue test (20 Hz frequency; initial load= 100 N; step= 50 N; 10,000 cycles/step, upon specimen failure detection). The collected data were analyzed by two-way ANOVA (α= 0.05) to verify differences by considering 'piston material' and 'piston diameter' as factors, and their association. In addition, a survival analysis (Kaplan Meier with Mantel-Cox log-rank post-hoc tests) was conducted (α= 0.05). Fractographic and finite element (FEA) analyzes were also performed. 'Piston material' (p= 0.040, F= 4.43) and 'piston diameter' (p < 0.000, F= 563.21) had a significant influence on the fatigue failure load (FFL) and the number of cycles for failure (CFF) values. Feldspathic restorations showed higher FFL and CFF (p < 0.05) when tested with a 40 mm diameter piston compared to a 6 mm diameter piston (ER_40 and SS_40 > ER_6 > SS_6). In relation to the piston material, ER and SS pistons with 40 mm diameter promoted similar fatigue performance (ER_40: 946.67 N/179,333 cycles = SS_40: 936.67 N/177,333 cycles), while 6 mm diameter groups presented different fatigue performance (ER_6: 440 N; 78,000 cycles > SS_6: 353.3 N; 60,667 cycles). Hertzian cone crack failures were only observed in the groups tested with 6 mm pistons, regardless of piston material. Higher stress concentration on the ceramic surface was observed when using 6 mm diameter pistons, whereas the SS_6 group showed a slight increase in stress concentration in comparison to the ER_6 group. The piston diameter showed an influence on the fatigue behavior, failure mode, and stress distribution of feldspathic ceramic simplified restorations. However, the influence of piston material is only observed when 6 mm diameter pistons are used. The 40 mm diameter pistons led to radial crack, being more appropriate for fatigue test of simplified feldspathic ceramic restorations with a thickness ≤ 1 mm. Whilst the 6 mm diameter pistons should be avoided, once tend to induce Hertzian cone crack failures and to underestimate fatigue performance.


Subject(s)
Ceramics , Epoxy Resins , Dental Porcelain , Dental Restoration Failure , Dental Stress Analysis , Materials Testing , Stainless Steel , Surface Properties
16.
J Mech Behav Biomed Mater ; 132: 105278, 2022 08.
Article in English | MEDLINE | ID: mdl-35653917

ABSTRACT

The aim of this study was to evaluate the topography and the fatigue performance of lithium disilicate glass-ceramic after surface grinding through different laboratory protocols used to simulate the Computer-aided design/Computer-aided manufacturing (CAD/CAM) milling. Ceramic discs (IPS e.max CAD, Ø = 13.5 mm × 1.2 mm of thickness) were produced through different methodologies: milling in CAD/CAM system (CAD/CAM group); produced in-lab with a polished surface (POL group); or produced through in-lab methods and randomly distributed into five groups according to different grinding protocols to simulate the CAD/CAM milling [grinding with a CAD/CAM bur coupled to a mandrel (CAD/CAM Bur group); fine diamond bur using oscillatory movements (DBO group); fine diamond bur in x and y axes of the disc (DBXY group); #60-grit silicon carbide sandpaper (SiC group); and #60-grit wood sandpaper (WS group)]. The specimens were fatigue tested (n = 15) according to the step-stress method (initial load: 60 N; step-size: 20 N; 10,000 cycles/step; 20 Hz frequency). A roughness analysis was performed on all specimens, while fractal dimension (FD) and fractography were performed on representative samples. The Kaplan-Meier analysis showed that the POL (293.3 N) group presented better fatigue performance (higher load and number of cycles for failure) (p < 0.05) than the other groups (CAD/CAM = 222.7 N; CAD/CAM Bur = 181.3 N; DBO = 184.0 N; DBXY = 192.0 N; SiC = 182.6 N; WS = 182.6 N). For roughness, only the SiC (Ra = 1.616; Rz = 10.465) and WS (Ra = 1.673; Rz = 10.655) groups produced statistically similar Ra (µm) and Rz (µm) values to the CAD/CAM (Ra = 1.628; Rz = 9.571) group (p > 0.05). The surface created by CAD/CAM milling and POL group exhibited more complexity (FD) higher values than the experimental groups. For the ceramic surface topography images, the CAD/CAM milling visibly produced a uniform surface compared to the other groups; however, the POL group was the smoothest. The DBO, DBXY, SiC, and WS groups resulted in similar characteristics of surface topography. Therefore, although the SiC and WS groups showed similar roughness to the control group (CAD/CAM), no in-lab simulation method was fully capable to mimic the mechanical performance of the CAD/CAM-milled lithium disilicate glass-ceramic.


Subject(s)
Ceramics , Computer-Aided Design , Dental Porcelain , Diamond , Materials Testing , Surface Properties
17.
Dent Mater ; 38(6): 1060-1071, 2022 06.
Article in English | MEDLINE | ID: mdl-35527035

ABSTRACT

OBJECTIVES: This study aimed to evaluate the impact of mechanical fatigue cycling using the step-stress approach along with hydrothermaldegradation (134 ºC with a constant pressure of 2 bars for 20 h), and a novel intercalated hydrothermal/fatigue aging protocol on different aspects of the aging resistance of three generations of dental zirconias. METHODS: "Y"Z T (VITA), INCORIS "T"ZI (Dentsply Sirona) and "K"ATANA UTML (Noritake Kuraray) - 1st, 2nd and 3rd generation, respectively-, zirconia disks (N = 153), were divided into 6 groups (n = 3) for monotonic testing and 9 groups (n = 15) for mechanical fatigue testing, according to 3 proposed treatments for each zirconia: CF (control - only mechanical fatigue cycling); AF (aging in hydrothermal reactor at 134 °C for 20 h + mechanical fatigue cycling); AFA (Alternating protocol: 4 steps of 5 h of hydrothermal aging intercalated with mechanical fatigue cycling). Mechanical fatigue aging was performed according to the step-stress approach through biaxial flexural setup (piston-on-3-balls, initial strength: 100 MPa, step: 50 MPa/10,000, frequency: 20 Hz) until failure. Data were analyzed using Kaplan-Meier and Mantel-Cox test (α = 0.05), in addition to Weibull analysis. Fractured disks were analyzed in stereomicroscope, Scanning Electron Microscopy and X-Ray Diffraction. RESULTS: Continuous hydrothermal and mechanical fatigue cycling decreased the fatigue strength of YAF group (516 ± 38 MPa), while the alternating protocol increased it (730 ± 58 MPa). KATANA UTML showed no differences for both treatments and did not undergo t-m phase transformation. The TAF group showed the highest fatigue strength (810 ± 76 MPa) and cycles for failure (147,000.00 cycles). The fracture origin for all specimens was on the tensile side in pre-existing defects. SIGNIFICANCE: INCORIS TZI zirconia had higher fatigue strength and survival rates after hydrothermal and mechanical fatigue aging. Although less resistant, KATANA UTML did not suffer chemical degradation.


Subject(s)
Dental Materials , Yttrium , Ceramics , Materials Testing , Stress, Mechanical , Surface Properties , Zirconium
18.
J Adhes Dent ; 24(1): 209-222, 2022 Apr 13.
Article in English | MEDLINE | ID: mdl-35416449

ABSTRACT

PURPOSE: This systematic review aims to explore and compile the effect of adhesive luting on the mechanical properties of dental ceramics used as restorative materials. MATERIALS AND METHODS: The PubMed/MEDLINE, Web of Science and Scopus databases were searched on January 31st, 2021 to select laboratory studies written in English, without publishing-date restrictions, which compared the mechanical properties of commercially available dental ceramics as restorative materials luted using adhesive vs non-adhesive strategies. A total of 20 (out of 2039) studies were eligible and included in the analysis. Two authors independently selected the studies, extracted the data and assessed the risk of bias. Mean differences (RevMan5.1, random effects model, α = 0.05) were obtained by comparing resistance values of adhesive and non-adhesive conditions (global analysis). Subgroup analyses were performed considering ceramic composition and aging. RESULTS: In the global analysis, adhesive luting induced higher mechanical resistance values compared to non-adhesive luting (p ≤ 0.01). The same effect was observed for glass and alumina ceramics (p ≤ 0.01), but not for zirconia polycrystals (p = 0.83). Adhesive luting was favorable in both the aged and non-aged subgroup analysis (p ≤ 0.01). High heterogeneity was found in all meta-analyses. All analyzed studies in the systematic review scored negatively for risk of bias in most of the factors considered. CONCLUSIONS: Adhesive luting reinforces the mechanical properties of dental ceramics used as restorative materials, with the exception of zirconia polycrystals.


Subject(s)
Dental Bonding , Resin Cements , Ceramics/chemistry , Dental Cements/chemistry , Dental Materials/chemistry , Dental Porcelain/chemistry , Materials Testing , Resin Cements/chemistry , Surface Properties
19.
Dent Mater ; 38(3): e59-e67, 2022 03.
Article in English | MEDLINE | ID: mdl-34969523

ABSTRACT

OBJECTIVE: To assess the effects of a resin cement in high and low viscosity and distinct conditioning of the intaglio surface of lithium disilicate glass-ceramic crowns on fatigue performance of the crowns. METHODS: Prosthetic preparations (full-crown) in resin epoxy and crowns in lithium disilicate glass-ceramic were machined and allocated considering 2 factors (n = 10): "surface treatment" (HF - 5% hydrofluoric acid etching, followed by silane application; or E&P-self-etching ceramic primer) and "resin cement" (high or low viscosity). The preparations were etched with 10% hydrofluoric acid and an adhesive was applied. The intaglio surfaces of the ceramic crowns were treated as aforementioned (HF or E&P) and luted with high or low viscosity. The bonded sets were subjected to fatigue testing (step-stress approach: initial load of 200 N, step-size of 50 N, 10,000 cycles/step, 20 Hz) and complementary analyses (fractographic, topographic, and cross-sectional bonded interfacial zone analyses) were performed. RESULTS: Treatment with HF and silane with high viscosity resin cement (955 N/156,000 cycles) and E&P with low viscosity resin cement (1090 N/183,000 cycles) showed the best fatigue performance (statistical similarity between them). The failures originated from defects of the cement-ceramic interface, and the HF treatment induced a more pronounced topographical alteration. SIGNIFICANCE: Distinct topographical patterns from the HF and E&P treatments induced better fatigue results for the specific viscosity of the resin cement. Therefore, the fatigue performance depended on the existing topography, type of intaglio surface's defects/irregularities after surface treatment, and how the luting agent filled the irregularities.


Subject(s)
Dental Bonding , Resin Cements , Ceramics , Cross-Sectional Studies , Crowns , Dental Porcelain , Dental Stress Analysis , Hydrofluoric Acid , Materials Testing , Surface Properties , Viscosity
20.
J Mech Behav Biomed Mater ; 126: 104985, 2022 02.
Article in English | MEDLINE | ID: mdl-34861521

ABSTRACT

The aim of the present scoping review was to identify and discuss the methods, testing parameters, and characteristics used to induce cyclic fatigue on non-anatomic dental ceramic specimens. In vitro studies written in English which evaluated commercially-available non-anatomic dental ceramic specimens subjected to mechanical cyclic fatigue were selected. The search was performed in the PubMed, Scopus and Web of Science databases. The initial search yielded 1,636 articles, of which 81 were included. Based on the collected data, most of the included studies evaluated dental ceramic specimens cemented to supporting substrate (n= 42; 51.9%); used step-stress (n= 35; 42.2%) accelerated fatigue test, loading frequencies above 10 Hz (n= 31, 35.6%), stainless steel (n = 28, 32.6%) load applicator with spherical shaped tip 40 mm diameter (n= 25, 30.9%); applied only axial loads (n= 77, 95.1%); and considered a wet testing environment (n= 65, 78.3%). The definition of test geometry, method, and testing parameters must be cautiously considered according to the study objective and the scenario that is simulated. Accelerated fatigue tests, load frequencies up to 20 Hz, a 40 mm stainless steel spherical load applicator and a wet testing environment are the major common defined parameters presented in the existing literature. More studies exploring the influence of such factors on fatigue mechanism are necessary.


Subject(s)
Ceramics , Dental Porcelain , Dental Restoration Failure , Dental Stress Analysis , Materials Testing , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...