Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
Arch Orthop Trauma Surg ; 144(1): 493-500, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37740060

ABSTRACT

INTRODUCTION: Bone preservation and long-term survival are the main challenges in cementless total hip arthroplasty (THA). A good bone stock is especially important for adequate anchorage of the cup in revision cases. However, the optimal acetabular cup design for preserving good bone stock is still unclear. We aimed to compare clinical outcome, radiological alterations, migration, and wear at mid-term for two different cup types. MATERIALS AND METHODS: This retrospective matched-pair study was performed using the data for 98 THA cases treated with a monoblock cup composed of vitamin E-blended highly cross-linked polyethylene (VEPE; monoblock group) or a modular cup composed of a highly cross-linked polyethylene (HXLPE) without an antioxidant (modular group). Clinical results were evaluated using the Harris Hip Score (HHS). The obtained radiographs were analyzed for radiological alterations, migration, and wear using Einzel-Bild-Röntgen-Analyse (EBRA) software. RESULTS: The mean follow-up duration was 73.2 ± 19.2 months (range: 32-108 months) and 60.5 ± 12.2 months (range: 20-84 months) in the monoblock and modular groups, respectively. HHS improved to 95.7 points in the monoblock group and 97.6 points in the modular group, without significant differences (p = 0.425). EBRA measurements were obtained in all cases. Acetabular bone alterations were not detected on radiological assessments. Mean cup migration was 1.67 ± 0.92 mm (range: 0.46-3.94 mm) and 1.24 ± 0.87 mm (range: 0.22-3.62 mm) in the monoblock and modular groups. The mean wear rate was 0.21 ± 0.18 mm (range: 0.00-0.70 mm) and 0.20 ± 0.13 mm (range: 0.00-0.50 mm) in the monoblock and modular groups. Both migration and wear pattern showed no significant differences (p = 0.741 and 0.243). None of the cases required revision surgery, yielding an implant survival rate of 100% in both groups. CONCLUSION: The isoelastic press-fit monoblock VEPE cup and modular metal-back HXLPE cup showed equivalent mid-term wear and cup migration. Long-term studies are required to determine the effects of modularity, isoelasticity, and polyethylene stabilization with vitamin E on cup loosening and survival rates.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Retrospective Studies , Matched-Pair Analysis , Arthroplasty, Replacement, Hip/methods , Acetabulum/diagnostic imaging , Acetabulum/surgery , Polyethylene/therapeutic use , Software , Metals , Vitamin E , Prosthesis Design , Prosthesis Failure , Follow-Up Studies
2.
J Hand Surg Am ; 49(1): 8-14, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37978963

ABSTRACT

PURPOSE: The purpose of the study was to determine if the sphericity of the thumb metacarpophalangeal (MCP) joint influences the joint's rotational axis (RA) and elongation patterns of the ulnar collateral ligament (UCL). METHODS: Ulnar collateral ligament origins and attachments of 28 fresh-frozen cadaveric thumbs were marked with a radiopaque marker. Lateral radiographs were obtained in neutral and 20°, 40°, and 60° of flexion. The dorsal and palmar joint gap and the length of four different UCL portions were digitally measured in all flexion states. The RA was determined by the intersection of the midshaft axis of the proximal phalanx in neutral and flexion states. Sphericity of the MCP joint was assessed using morphometric parameters. Joints were grouped as round or flat. Differences in all measured parameters between groups were analyzed. RESULTS: During flexion, the dorsal joint gap increased by 322% in flat joints and 163% in round joints. The palmar joint gap decreased to 45% in flat joints and to 87% in round joints. The RA was at 29% of metacarpal height and 96% of metacarpal length in flat joints and at 40% of height and 86% of length in round joints. Maximum UCL elongation (111%) was noted at 40° flexion in the dorsal proper UCL in flat joints and at 60° flexion in the accessory UCL (117%) in round joints. CONCLUSIONS: In flat MCP joints, the RA is more dorsal and distal in the metacarpal head compared to round joints, resulting in a hinged flexion motion. Elongation of the UCL is highest at end flexion in round joints and highest at midflexion in flat joints. CLINICAL RELEVANCE: The different kinematics of flat and round MCP joints may contribute to the understanding of the pathophysiology of UCL ruptures. The propensity of this injury and the position in which they occur may be affected by the MCP joint morphology.


Subject(s)
Collateral Ligament, Ulnar , Collateral Ligaments , Humans , Thumb , Collateral Ligament, Ulnar/diagnostic imaging , Collateral Ligament, Ulnar/injuries , Collateral Ligaments/injuries , Biomechanical Phenomena , Metacarpophalangeal Joint
3.
J Orthop Surg Res ; 18(1): 971, 2023 Dec 17.
Article in English | MEDLINE | ID: mdl-38105223

ABSTRACT

BACKGROUND: Various fixation methods are available for tibiotalocalcaneal arthrodesis: nail, plate, or screws. An intramedullary bone stabilization system within a balloon catheter has not previously been used in tibiotalocalcaneal arthrodesis. The aim of this study was to compare the stability of these techniques. METHODS: Twenty-four lower legs from fresh-frozen human cadavers were used. Tibiotalocalcaneal arthrodesis was performed with a retrograde nail, a lateral locking plate, three cancellous screws, or an intramedullary bone stabilization system. The ankles were loaded cyclically in plantarflexion and dorsiflexion. RESULTS: For cyclic loading at 125 N, the mean range of motion was 1.7 mm for nail, 2.2 mm for plate, 6.0 mm for screws, and 9.0 mm for the bone stabilization system (P < .01). For cyclic loading at 250 N, the mean range of motion was 4.4 mm for nail, 7.5 mm for plate, 12.1 mm for screws, and 14.6 mm for the bone stabilization system (P < .01). The mean cycle of failure was 4191 for nail, 3553 for plate, 3725 for screws, and 2132 for the bone stabilization system (P = .10). CONCLUSIONS: The stability of the tibiotalocalcaneal arthrodesis differs depending on the fixation method, with nail or plate showing the greatest stability and the bone stabilization system the least. When three screws are used for tibiotalocalcaneal arthrodesis, the stability is intermediate. As the biomechanical stability of the bone stabilization system is low, it cannot be recommended for tibiotalocalcaneal arthrodesis.


Subject(s)
Ankle Joint , Bone Nails , Humans , Ankle Joint/surgery , Biomechanical Phenomena , Arthrodesis/methods , Cadaver
4.
J Hand Surg Eur Vol ; 48(8): 768-772, 2023 09.
Article in English | MEDLINE | ID: mdl-37005740

ABSTRACT

Studies on graft reconstruction techniques for ruptured thumb metacarpophalangeal (MCP) ulnar collateral ligaments (UCL) do not consider the variety of MCP joint morphology. Optimal reconstruction method for flat MCP joints is therefore unclear. Twenty-four fresh-frozen, human thumbs were tested for flexion, extension and valgus stability of the MCP joint. After resection of the UCL, four reconstruction methods, differing in the metacarpal origin and phalangeal attachment, were performed on each specimen, which were then tested again in the same way. Specimens were grouped as 'round' or 'flat' depending on morphometric parameters and group differences were analysed. In flat joints, only the non-anatomical Glickel reconstruction and a modified Fairhurst reconstruction maintained normal mobility and stability. In round joints, only the Glickel reconstruction maintained normal mobility and stability. The original Fairhurst method and a modification with the origin palmar in the metacarpus were disadvantageous in both flat and round joints.


Subject(s)
Collateral Ligament, Ulnar , Collateral Ligaments , Humans , Collateral Ligament, Ulnar/surgery , Thumb/surgery , Collateral Ligaments/surgery , Range of Motion, Articular , Metacarpophalangeal Joint/surgery
5.
Technol Health Care ; 31(5): 1607-1617, 2023.
Article in English | MEDLINE | ID: mdl-36970923

ABSTRACT

BACKGROUND: Rupture of the anterior cruciate ligament (ACL) is one of the most common knee injuries and has substantial impact on knee function. Beside primary ruptures, an increasing number of re-(re-)ruptures occur, representing a therapeutical challenge for the treating surgeon. Several risk factors for re-ruptures have been previously identified, including an increased tibial slope. OBJECTIVE: In this study, we investigated the effect of femoral condyle configuration on ACL-ruptures and re-ruptures. METHODS: In-vivo magnetic resonance imaging scans of three different groups of patients were compared. Group 1 included patients with an intact ACL on both sides, group 2 included patients with primary, unilateral ACL-rupture, while group 3 included patients with an ACL-re-rupture or re-(re-)rupture. Fourteen different variables were obtained and analyzed regarding their impact on ACL-re-(re-)rupture. RESULTS: Overall, 334 knees were investigated. Our data allowed us to define parameters to identify anatomical configurations of bones associated with an increased risk of ACL-re-rupture. Our results show, that patients with ACL-re-rupture show increased radii of the extension facet of the lateral femoral condyle (p< 0.001) as well as of the extension facet of the medial femoral condyle (p< 0.001). CONCLUSION: We conclude that a spherical femoral condyle form does influence the clinical outcome after ACL-reconstruction.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Humans , Knee Joint/surgery , Anterior Cruciate Ligament/pathology , Anterior Cruciate Ligament/surgery , Femur/surgery , Femur/pathology , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Injuries/pathology , Tibia/surgery , Tibia/pathology , Magnetic Resonance Imaging , Bone and Bones/pathology , Anterior Cruciate Ligament Reconstruction/methods
6.
Z Orthop Unfall ; 161(4): 396-404, 2023 Aug.
Article in English, German | MEDLINE | ID: mdl-35104904

ABSTRACT

In recent decades, a large number of cementless short stems have been introduced to the market. The concept aims at saving soft tissue using minimally invasive surgery and at the same time preserving as much bone as possible. In particular, the latest generation of short stems, which are implanted using a calcar-guided round-the-corner technique, are attracting increasing attention. An individualised resection level allows individual stem alignment and thus an ideal reconstruction of the hip anatomy. The early clinical results of short-stem total hip arthroplasty (THA) are promising and have led to an expansion of the indications and limitations for the use of short stems. In particular, the individual positioning in valgus or varus and the resulting individual metaphyseal or metadiaphyseal anchorage offers various possibilities to reconstruct even abnormal joint morphologies. Consequently, short stems are increasingly used in patients with complex anatomical variations or in cases of osteonecrosis of the femoral head. In some various cases, they can also be used in revision or conversion arthroplasty. In some patients, short stems can also be used after femoral neck fracture. Currently, scientific data on those areas of indication of short-stem THA is scarce.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/methods , Treatment Outcome , Prosthesis Design , Reoperation , Retrospective Studies
7.
Clin Biomech (Bristol, Avon) ; 92: 105588, 2022 02.
Article in English | MEDLINE | ID: mdl-35121348

ABSTRACT

BACKGROUND: Various fixation methods are available for the operative treatment of metatarsal shaft fractures: Kirschner wire, Titanium elastic nail, plate, or an intramedullary bone stabilization system within a balloon catheter. The aim of this study was to compare the stability of these techniques. METHODS: 72 metatarsals II to V from fresh frozen human cadaver feet were used. A shaft fracture was performed and fixed with a 1.6-mm Kirschner wire, a 1.5-mm Titanium elastic nail, a locking 6-hole-plate, or an intramedullary bone stabilization system. In a cantilever configuration, the head of the metatarsals was loaded statically (2 mm/min until failure; all groups) or cyclically (0 to 20 N for 1000 cycles with 10 mm/s, after 1000 cycles 2 mm/min until failure; plate and bone stabilization system). FINDINGS: The mean failure strength for static loading was 17 N for Kirschner wire, 13 N for Titanium elastic nail, 73 N for plate and 34 N for the bone stabilization system (P < .01). For cyclic loading, the mean cycle of failure was 1000 for plate and 961 for the bone stabilization system (P = .76). The mean failure strength after cyclic loading was 73 N for plate and 48 N for the bone stabilization system (P = .03). INTERPRETATION: Stability differs depending on the fixation method, with a plate showing the greatest stability and Kirschner wire or Titanium elastic nail the least. The stability of the bone stabilization system for fixing metatarsal shaft fractures is intermediate.


Subject(s)
Fracture Fixation, Intramedullary , Fractures, Bone , Metatarsal Bones , Biomechanical Phenomena , Bone Plates , Bone Screws , Cadaver , Fracture Fixation, Internal/methods , Fracture Fixation, Intramedullary/methods , Fractures, Bone/surgery , Humans , Metatarsal Bones/surgery
8.
Orthopade ; 51(3): 230-238, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34581833

ABSTRACT

BACKGROUND: Short stems have constantly gained popularity in primary total hip arthroplasty (THA) over the last decade. Although cementless short stems are not primarily designed to be used as revision implants, there may be certain indications for which downsizing the femoral component in failed conventional THA is potentially advantageous. METHODS: In this single center retrospective case series, six patients who underwent revision using a calcar-guided short stem after failed THA are presented. The mean follow-up was 3.32 years (SD 0.63 years). The health status was evaluated by the EQ-5D-5L score. Patient reported outcome measurements (PROM) were recorded using the Harris hip score (HHS) and The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Pain and satisfaction were assessed using a visual analogue scale (VAS). Radiographic analysis was performed by evaluating osteolysis, stress shielding, alignment and signs of aseptic loosening. Complications were documented. RESULTS: At last follow-up the mean EQ-5D-5L index was 0.851 (SD 0.098). Clinical outcome was excellent (HHS ≥ 90) in 4 patients and moderate (HHS 71 and 79) in 2 patients. The mean WOMAC score was 9.20% (SD 12.61%). Pain and satisfaction on VAS were 1.00 (SD 1.15) and 9.17 (SD 0.37), respectively. No major complications occurred. To date, no further revision surgery was needed. Radiologically, no signs of subsidence, aseptic loosening, stress shielding and fractures were obvious. CONCLUSION: The present case series indicates that in failed conventional THA downsizing may be considered a treatment option, using short stem THA in selected cases.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Follow-Up Studies , Hip Prosthesis/adverse effects , Humans , Prosthesis Design , Reoperation , Retrospective Studies , Treatment Outcome
9.
J Orthop ; 27: 130-136, 2021.
Article in English | MEDLINE | ID: mdl-34616117

ABSTRACT

BACKGROUND: One-stage, bilateral, short-stem total hip arthroplasty (1B-ssTHA) represents an alternative to staged, unilateral, short-stem total hip arthroplasty (U-ssTHA); however, the safety and reliability of 1B-ssTHA remain unknown. The objective of the present study was to compare the functional outcomes, complications, and mortality rates between 1B-ssTHA and U-ssTHA at mid-term. METHODS: A retrospective, matched-pair study was performed, including 216 short stems implanted in 162 patients. Among the study population, 54 patients were treated with 1B-ssTHA. Patients were matched by gender, age, body mass index (BMI), and American Society of Anesthesiologists (ASA) classification. A total of 46 full matches could be accomplished. The mean follow-up time for the 1B-ssTHA group was 61.7 months (standard deviation [SD] 6.2 months), compared with was 63.4 months (SD 8.0 months) for the U-ssTHA group. Mortality, complication, and revision rates were documented. For clinical examinations, the visual analogue scale (VAS) was used to evaluate satisfaction, rest pain, and load pain, and the Harris Hip Score (HHS) was determined. RESULTS: No surgery-related deaths were observed. At mid-term, none of the 1B-ssTHA patients required stem revision. The rate of complications for both groups was low. The mean drop in haemoglobin measured in the 1B-ssTHA group was 4.42 mg/dl, compared with 3.18 mg/dl in the U-ssTHA group. The mean HHS in the 1B-ssTHA group was 98.3 points (SD 2.80), whereas, in the U-ssTHA group, the mean HHS was 97.9 points (SD 3.44) (p = 0.478). Satisfaction rates were significantly higher in the 1B-ssTHA group (p = 0.04) than in the U-ssTHA group, whereas no significant differences were found for pain at rest and pain at load (p = 0.56 and p = 0.26, respectively). CONCLUSION: Our findings indicate that 1B-ssTHA is an effective and beneficial procedure for a select population. Mortality, complications, implant survival, and clinical outcomes were comparable to those for a matched group with unilateral osteoarthritis treated with U-ssTHA. However, an increase in blood loss must be acknowledged for the 1B-ssTHA procedure.

10.
Acta Orthop Traumatol Turc ; 55(4): 349-354, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34464312

ABSTRACT

OBJECTIVE: The aim of the study was to investigate the effect of different arm positions (hand pronation/supination and elbow flexion/extension) on fragment rotation in extra-articular distal radius fractures in a cadaveric model. METHODS: In this study, ten fresh-frozen cadaveric upper extremities from five donors with a mean age of 69 ± 12 years were used. Two cortical pins were inserted in the radius and the ulna. In a custom-made device, different forearm (30°, 60°, and 90° of pronation and supination) and elbow positions (full extension) were tested, using a fluoroscopic analysis. The degree of malrotation between the two pins was measured in these positions. At the last test sequence, the tendon of the brachioradialis muscle was released. RESULTS: A significant difference was found in concerns of the rotational angle between the distal fragment and the radial shaft at different degrees of pronation and supination if the elbow joint was in an extended and flexed position. The release of the brachioradialis tendon did not show any effect. CONCLUSION: The results of this study supported that rotational malpositions in distal radius fractures can be decreased if the forearm is in a neutral position. Accordingly, the forearm should be in a neutral position while initially immobilization in a plaster splint is performed.


Subject(s)
Forearm , Radius Fractures , Aged , Aged, 80 and over , Cadaver , Humans , Middle Aged , Pronation , Radius/diagnostic imaging , Rotation , Supination
11.
J Orthop ; 24: 274-279, 2021.
Article in English | MEDLINE | ID: mdl-33897129

ABSTRACT

BACKGROUND: The usage of short stems in primary total hip arthroplasty (THA) has constantly gained popularity over the last decade, however, to date, short stems are not eligible to be used as revision implants. The aim of this study was to retrospectively evaluate the outcome of revision surgery of failed hip resurfacing arthroplasty (HRA) using short-stem THA. METHODS: In a single center, retrospective analysis, 6 consecutive patients who were treated with a calcar-guided short stem after failure of HRA were evaluated. The mean follow-up was 3.25 years (SD 0.45). Patient reported outcome measurements (PROMs) were recorded using the Harris hip score (HHS) and The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). The health status was evaluated by the EQ-5D-5L score. Pain and satisfaction were obtained using the visual analogue scale (VAS). Radiographic analysis was performed by evaluating osteolysis, stress shielding, alignement and signs of aseptic loosening. Complications were documented. RESULTS: At last follow-up, clinical outcome was excellent (HHS ≥ 90) in 5 patients and good (HHS = 87) in 1 patient. The mean WOMAC score was 5.73% (SD 3.66%). The mean EQ-5D-5L index was 0.914 (SD 0.07). Pain and satisfaction on VAS was 1.83 (SD 5.18) and 8.67 (SD 0.94), respectively. Radiologically, no signs of subsidence, aseptic loosening, stress shielding and fracture were obvious. No major complications occurred. To date, no further revision surgery was needed. CONCLUSIONS: The outcomes of the present case series propose that HRA can be safely revised using short-stem THA in a selected patient group. Clinical and radiological results are encouraging. Based on the present data, short stems may be considered as a revision implant for failed HRA for experienced surgeons.

12.
BMC Musculoskelet Disord ; 22(1): 107, 2021 Jan 23.
Article in English | MEDLINE | ID: mdl-33485345

ABSTRACT

BACKGROUND: The newest generation of cementless titanium-coated, isoelastic monoblock cup with vitamin E-blended highly cross-linked polyethylene (HXLPE) was introduced to the market in 2009. The aim of the present study was to obtain mid-term follow-up data including migration and wear analyses. METHODS: This prospective study investigated 101 primary total hip arthroplasty (THA) cases in 96 patients treated at a single institution. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) and pain and satisfication on a visual analogue scale (VAS) were assessed at a mean follow-up of 79.0 months. Migration and wear were assessed using Einzel-Bild-Roentgen-Analyse (EBRA) software. Radiological acetabular bone alterations and complications were documented. RESULTS: At mid-term follow-up (mean 79.0 months, range: 51.8-101.7), 81 cases with complete clinical and radiological data were analyzed. Utilisable EBRA measurements were obtained for 42 hips. The mean HHS was 91.1 (range 38.0-100.0), VAS satisfaction was 9.6 (range 6.0-10.0), VAS rest pain was 0.2 (range 0.0-4.0), and VAS load pain was 0.6 (range 0.0-9.0). Mean migration was 0.86 mm (range: 0.0-2.56) at 24 months and 1.34 mm (range: 0.09-3.14) at 5 years, and the mean annual migration rate was 0.22 (range: - 0.24-1.34). The mean total wear was 0.4 mm (range: 0.03-1.0), corresponding to a mean annual wear rate of 0.06 mm per year (range: 0.0-0.17). Radiographic analysis did not reveal any cases of osteolysis, and no revision surgeries had to be performed. CONCLUSIONS: After using vitamin-E blended HXLPE in cementless isoelastic monoblock cups, there were no obvious signs of osteolysis or aseptic loosening occurred. No patients required revision surgery after mid-term follow-up. Cup migration and wear values were well below the benchmarks considered predictive for potential future failure. TRIAL REGISTRATION: The trial registration number on ClinicalTrials.gov : NCT04322916 (retrospectively registered at 26.03.2020).


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/diagnostic imaging , Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Follow-Up Studies , Hip Prosthesis/adverse effects , Humans , Polyethylene , Prospective Studies , Prosthesis Design , Prosthesis Failure , Vitamin E
13.
Arch Orthop Trauma Surg ; 140(12): 2091-2100, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33011847

ABSTRACT

INTRODUCTION: Osteonecrosis of the femoral head (ONFH) is a disabling condition that often results in secondary arthritis necessitating total hip arthroplasty (THA). Short-stem THA has constantly gained popularity. It remains controversial, whether ONFH represents a risk factor for failure after the implantation of short stems with pronounced metaphyseal anchorage. The potential spread of the osteonecrotic area and bone marrow edema into the metaphyseal bone might result in compromised stability. Early implant migration is considered predictive of subsequent aseptic loosening. The purpose of this study was a migration analysis of a modern, calcar-guided short-stem implant in patients with ONFH in a mid-term follow-up. MATERIALS AND METHODS: This retrospective analysis investigated the migration pattern of 45 calcar-guided short stems in patients with ONFH, using Einzel-Bild-Roentgen-Analyse Femoral-Component-Analysis (EBRA-FCA). Influencing factors such as ARCO categories, age, gender, body weight and BMI were analyzed. Complications and adverse events were documented. RESULTS: At mid-term [48.1 months (SD 20.7 months)], mean axial migration was 1.56 mm (SD 1.77 mm). Mean migration rate stabilized after 2 years. No influence of ARCO categories, age and BMI was found. A tendency of increased axial migration was observed in male patients and in overweight patients. No revision surgeries had to be performed during follow-up. CONCLUSION: The results indicate a migration pattern comparable to that of primary osteoarthritis patients with slight initial migration under full load followed by subsequent stabilization in the metaphyseal femur. The 100% survival rate at mid-term supports the usage of this short-stem design in patients with ONFH.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Femur Head Necrosis/surgery , Hip Prosthesis , Osteoarthritis, Hip/surgery , Prosthesis Design , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Body Weight , Female , Femur/surgery , Femur Head/surgery , Femur Head Necrosis/complications , Follow-Up Studies , Humans , Male , Middle Aged , Osteoarthritis, Hip/etiology , Retrospective Studies , Risk Factors , Time Factors , Young Adult
14.
J Orthop Res ; 38(4): 747-758, 2020 04.
Article in English | MEDLINE | ID: mdl-31696983

ABSTRACT

Knee osteoarthritis (OA) involves several structures and molecules in the joint, which interact in a pathophysiological process. One of these molecules is the cartilage oligomeric matrix protein (COMP). Elevated COMP levels in the synovial fluid as well as in the serum have been described in OA patients. However, this has not been described in the infrapatellar fat pad (IPFP) tissue before. In this prospective trial, we collected 14 IPFPs from patients with high-grade OA (mean age 63.8 ± 17.6 years) who underwent total knee replacement (OA group) and from 11 healthy patients (mean age 33.7 ± 14.8 years) who underwent anterior cruciate ligament reconstruction (control group). The presence of macrophages (CD68 and CD206) and proinflammatory cytokines (interleukin 1ß [IL-1ß] and IL-6) was analyzed. Histological and immunohistological examinations as well as immunoblotting analysis for COMP, leptin, and matrix-metalloproteinase-3 were performed. The IPFPs of both the OA and control group consisted of adipose tissue and fibrous tissue, and the fibrous tissue showed higher score values than the adipose tissue for COMP staining (intensity as well as stained area) in both groups. Although COMP could be detected in most samples, leptin expression was found only in single specimens. COMP could be detected mostly in the fibrous tissue portion of the IPFP. We speculate that it is involved in a remodeling process taking place in the IPFP during OA. Presence of leptin was irregular in immunohistology, and the control group showed higher scores in case of presence. Interestingly, immunoblotting could detect leptin in all analyzed samples. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society J Orthop Res 38:747-758, 2020.


Subject(s)
Adipose Tissue/metabolism , Cartilage Oligomeric Matrix Protein/metabolism , Osteoarthritis, Knee/metabolism , Adipose Tissue/pathology , Age Factors , Aged , Aged, 80 and over , Antigens, CD/analysis , Antigens, Differentiation, Myelomonocytic/analysis , Case-Control Studies , Extracellular Matrix/metabolism , Female , Humans , Interleukin-1beta/metabolism , Interleukin-6/metabolism , Lectins, C-Type/analysis , Leptin/metabolism , Male , Mannose Receptor , Mannose-Binding Lectins/analysis , Matrix Metalloproteinases/metabolism , Middle Aged , Osteoarthritis, Knee/pathology , Patella , Receptors, Cell Surface/analysis
15.
J Orthop Traumatol ; 20(1): 31, 2019 Oct 31.
Article in English | MEDLINE | ID: mdl-31673809

ABSTRACT

BACKGROUND: In recent years, a variety of short stems have been introduced. To date, mid- and long-term results of calcar-guided short-stem designs have been rarely available. MATERIALS AND METHODS: Two hundred and sixteen calcar-guided short stems were included in combination with a cementless cup in a prospective study. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) as well as pain and satisfaction on visual analogue scale (VAS) were assessed during a median follow-up of 61.7 months. Standardised radiographs were analysed at predefined time points regarding radiological alterations such as bone resorption and remodelling, radiolucency, osteolysis and cortical hypertrophy using modified Gruen zones. RESULTS: At mid-term follow-up, no revision surgery of the stem had to be performed in the whole collective. At 5 years, HHS was 97.8 (SD 4.7), satisfaction on VAS was 9.7 (SD 0.7), rest pain on VAS was 0.1 (SD 0.5), and load pain on VAS was 0.6 (SD 1.2). Compared to the 2-year results, femoral bone resorption increased significantly at the 5-year follow-up (3.9% versus 42.3%). Rate of femoral cortical hypertrophy remained stable, occurring in a total of 9 hips (4.5%). At the 5-year follow-up, 2 stems (1.0%) showed non-progressive radiolucent lines with a maximum width of 2 mm. Signs of osteolysis were not observed. Compared to the 2-year follow-up, no further subsidence was observed. CONCLUSIONS: The rate of stem revision (0%) at the mid-term follow-up was remarkable and indicates the principle of using a calcar-guided short stem as being a safe procedure. However, signs of bone-remodelling, indicating some amount of stress-shielding, must be acknowledged at 5 years depending on stem alignment and type of anchorage. LEVEL OF EVIDENCE: IV, Prospective observational study Trial registration German Clinical Trials Register, DRKS00012634, 07/07/2017 (retrospectively registered).


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Osteoarthritis/surgery , Prosthesis Design , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteoarthritis/diagnostic imaging , Osteoarthritis/etiology , Patient Satisfaction , Prospective Studies , Radiography , Reoperation , Time Factors , Treatment Outcome , Weight-Bearing
16.
Article in English | MEDLINE | ID: mdl-29605862

ABSTRACT

Unfortunately, the following reference was not included in the original publication of the article.

17.
Knee Surg Sports Traumatol Arthrosc ; 26(5): 1557-1563, 2018 May.
Article in English | MEDLINE | ID: mdl-28577064

ABSTRACT

PURPOSE AND HYPOTHESIS: Autologous blood transfusion drains are commonly used to reduce allogeneic blood transfusion rate after total knee arthroplasty. There is conflicting evidence as to whether autologous transfusion drains (ABT drains) were effective when restrictive transfusion triggers were used. The aim of our study was to ascertain where, as a part of a blood management protocol, autologous blood transfusion drains reduce the allogeneic blood transfusion rate after total knee arthroplasty. METHODS: Two-hundred total knee arthroplasty patients were included in the prospective randomized controlled study. After implantation, a Redon drain without vacuum assistance (control, n = 100) or an autologous blood transfusion drain (ABT group, n = 100) was used. Demographic and operative data were collected. The blood loss, total blood loss, blood values and transfusion rate were documented. RESULTS: The blood loss in the drains was significantly increased for the ABT group (409 vs. 297 ml, p < 0.001). There was a non-significant trend towards a higher total blood loss for ABT patients (1844 vs. 1685 ml, n.s.). The allogeneic blood transfusion rate was similar for both groups (8 vs. 9%, n.s.). Similarly, the number of transfused blood units was comparable between both groups (0.2U/patient vs. 0.17U/patient n.s.). CONCLUSION: In combination with restrictive blood transfusion triggers, ABT drains had no positive effect on the allogeneic blood transfusion rate. The blood loss in ABT drains was higher. As a consequence, the use of ABT drains was discontinued. LEVEL OF EVIDENCE: I.


Subject(s)
Arthroplasty, Replacement, Knee , Blood Loss, Surgical , Blood Transfusion, Autologous , Drainage/methods , Aged , Arthroplasty, Replacement, Knee/methods , Female , Humans , Male , Outcome Assessment, Health Care , Prospective Studies
18.
J Histochem Cytochem ; 65(10): 593-606, 2017 10.
Article in English | MEDLINE | ID: mdl-28846474

ABSTRACT

Perifibrillar adapter proteins, interconnecting collagen fibrils, and linking the collagen network with the aggrecan matrix seem to play a crucial role in the pathogenesis of osteoarthritis (OA). Therefore, we examined immunohistochemically the extracellular distribution of collagen II and the main perifibrillar adapter proteins-collagen IX, decorin, cartilage oligomeric matrix protein (COMP), and matrilin-3-in human samples of healthy (n=4) and OA (n=42) knee joint cartilage. Histopathology assessment was performed using an OA score. Staining patterns were evaluated in relation to the disease stage. The perifibrillar adapter proteins were uniformly distributed in the upper zones of healthy cartilage. In moderate OA (n=8; score 14.3 ± 4.7), all proteins analyzed were locally absent in the fibrillated area or the superficial and upper mid zone. In advanced OA (n=20; score 18.9 ± 5.3), they were uniformly distributed in these zones and accumulated pericellularly. Perifibrillar adapter proteins are important for the stabilization of the collagen network in the upper zones of healthy cartilage. Their degradation might be a critical event in early OA. In advanced OA, there are indications for an increased synthesis in an attempt to regenerate the lost tissue and to protect the remaining cartilage from further destruction.


Subject(s)
Cartilage, Articular/metabolism , Collagen Type II/metabolism , Extracellular Matrix/metabolism , Knee Joint/metabolism , Osteoarthritis/metabolism , Osteoarthritis/pathology , Aged , Aged, 80 and over , Cartilage, Articular/cytology , Cartilage, Articular/pathology , Case-Control Studies , Female , Humans , Male , Middle Aged , Protein Transport
19.
Knee Surg Sports Traumatol Arthrosc ; 25(9): 2695-2701, 2017 09.
Article in English | MEDLINE | ID: mdl-25957608

ABSTRACT

PURPOSE: The purpose of this study was to investigate whether there was a relationship between femoral neck antetorsion and the presence and pattern of osteoarthritis of the patellofemoral joint. It was hypothesized that an increased femoral neck antetorsion (1) correlates with osteoarthritic changes of the lateral facet of the patellofemoral joint and (2) correlates with an increased lateral trochlear height and a decreased sulcus angle. METHODS: Seventy-eight formalin-embedded cadaveric lower extremities from thirty-nine subjects with a median age of 74 years (range 60-88) were used. Surrounding soft tissues of the lower limb were removed. The femoral neck antetorsion was measured and referenced to the transepicondylar axis and the posterior condylar line. The height of the medial and lateral facet of the trochlea and the sulcus angle was measured. The location and the degree of patellofemoral cartilage degeneration were recorded. A Pearson's correlation analysis was performed to correlate the femoral neck antetorsion with the measured knee parameters. RESULTS: No significant correlation could be found between the femoral antetorsion and cartilage degeneration of the lateral patellofemoral joint (n.s.), the height of the lateral trochlea (n.s.) and the sulcus angle (n.s.). CONCLUSION: This study could not document that the femoral neck antetorsion and subsequent internal rotation of the distal femur correlated with the degree of degeneration of the lateral facet of the patellofemoral joint. Clinically, femoral internal rotation may play a minor role in the development of lateral patellofemoral joint degeneration.


Subject(s)
Bone Anteversion/pathology , Cartilage, Articular/pathology , Femur Neck/pathology , Osteoarthritis, Knee/etiology , Patellofemoral Joint/pathology , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Osteoarthritis, Knee/pathology
20.
Knee Surg Sports Traumatol Arthrosc ; 25(3): 943-948, 2017 Mar.
Article in English | MEDLINE | ID: mdl-25957610

ABSTRACT

PURPOSE: Posterolateral rotatory instability (PLRI) of the elbow is the result of an insufficient lateral collateral ligament complex (LCLC). Single-bundle reconstruction of the lateral ulnar collateral ligament (LUCL) represents the standard treatment method for chronic PLRI. However, cases of recurrent instability after LUCL reconstruction have been reported. The dual-reconstruction procedure has been described to anatomically restore the LUCL as well as the radial collateral ligament (RCL). It was hypothesized that anatomic reconstruction of the LCLC provides increased stability compared with the conventional technique. METHODS: Posterolateral rotatory displacement was assessed in eight fresh-frozen human elbows with a maximum load of 20 N. Data were obtained in 0°, 30°, 60°, 90° and 120° of elbow flexion for native specimens, dissected LCLC and three reconstruction methods: (1) single-bundle LUCL reconstruction, (2) single-bundle LUCL reconstruction with RCL augmentation, (3) dual-reconstruction technique (LUCL + RCL). RESULTS: All reconstruction methods were able to sufficiently restore posterolateral rotatory stability of the elbow over the full range of motion. There were no significant differences between the intact specimens and either reconstruction method. Dissection of the LCLC significantly increased PLRI compared with the other groups (p < 0.001). CONCLUSION: The less invasive dual-reconstruction technique is confirmed as a safe procedure for anatomic LCLC reconstruction. Primary stability is equal, yet not superior to conventional LUCL reconstruction. Hence, this biomechanical study does not confirm the hypothesis that more anatomic reconstruction techniques could reduce the risk of recurrent instability when compared to conventional LUCL reconstruction.


Subject(s)
Collateral Ligament, Ulnar/surgery , Collateral Ligaments/surgery , Elbow Joint/surgery , Joint Instability/surgery , Aged , Aged, 80 and over , Biomechanical Phenomena , Cadaver , Dissection , Elbow Joint/physiology , Humans , Joint Instability/physiopathology , Middle Aged , Range of Motion, Articular , Recurrence
SELECTION OF CITATIONS
SEARCH DETAIL
...