Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Neurol ; 17(1): 184, 2017 Sep 15.
Article in English | MEDLINE | ID: mdl-28915853

ABSTRACT

BACKGROUND: Human, hairy skin contains a subgroup of C-fibers, the C-low threshold mechanoreceptive afferents ((C-LTMR) C-tactile or C-touch (CT) fibers) that are linked with the signaling of affective aspects of human touch. Recent studies suggest an involvement of these afferents in the modulation of pain in healthy volunteers. Small fiber neuropathy (SFN) is associated with a damage of C-fibers. Therefore, an impairment of C-LTMRs can be assumed. We aimed to elaborate a possible role of CT-afferents in pain modulation by investigating healthy volunteers and SFN-patients. METHODS: Experiment I: 20 SFN-patients (12 women, median age 52.0 years) and 20 healthy controls (14 women, median age 43.0 years) participated in this prospective fMRI and psychophysical study. Heat-pain (HP), CT-targeted touch (slow brushing) and HP combined with CT-targeted touch were applied in randomized order to the left shank in a block design. The participants rated pain intensity on a visual analogue scale. Experiment II: We investigated a possible impact of pain intensity on CT induced pain modulation (10 healthy participants). The intensity of HP stimulation was chosen to induce pain intensity 50/100 (NRS). HP stimulation was applied with and without CT-targeted touch. RESULTS: Experiment I: CT-stimulation was sufficient to reduce heat pain in healthy participants (p = 0.016), but not in SFN-patients. HP induced pain intensity was significantly higher (32,2 vs 52,6) in SFN-patients. During HP, bold responses in pain associated areas were observed in both groups. Additional CT-stimulation elicited no significant difference of bold responses compared to HP. Experiment II: In healthy volunteers, we reproduced a significant reduction of HP intensity by CT-stimulation (p = 0.038). CONCLUSIONS: CT input seems to be sufficient to modulate pain, independent of intensity of the pain stimulus. As a prerequisite, the CT fibers have to be intact as in healthy volunteers. If CT fibers are impaired - as in SFN -, CT-targeted touch does not modulate pain intensity. The location of CT-induced pain modulation might be attributed to the level of the dorsal horn since the cortical activation pattern of heat pain with and without CT-targeted touch did not differ in healthy subjects and in SFN-patients.


Subject(s)
Nerve Fibers, Unmyelinated/metabolism , Pain/metabolism , Skin/metabolism , Adult , Aged , Case-Control Studies , Female , Hot Temperature , Humans , Male , Mechanoreceptors/physiology , Middle Aged , Pain Measurement , Prospective Studies , Touch , Young Adult
2.
Neuroradiology ; 56(3): 177-86, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24357075

ABSTRACT

INTRODUCTION: The purpose of this paper is to assess the value of 7 Tesla (7 T) MRI for the depiction of brain stem and cranial nerve (CN) anatomy. METHODS: Six volunteers were examined at 7 T using high-resolution SWI, MPRAGE, MP2RAGE, 3D SPACE T2, T2, and PD images to establish scanning parameters targeted at optimizing spatial resolution. Direct comparisons between 3 and 7 T were performed in two additional subjects using the finalized sequences (3 T: T2, PD, MPRAGE, SWAN; 7 T: 3D T2, MPRAGE, SWI, MP2RAGE). Artifacts and the depiction of structures were evaluated by two neuroradiologists using a standardized score sheet. RESULTS: Sequences could be established for high-resolution 7 T imaging even in caudal cranial areas. High in-plane resolution T2, PD, and SWI images provided depiction of inner brain stem structures such as pons fibers, raphe, reticular formation, nerve roots, and periaqueductal gray. MPRAGE and MP2RAGE provided clear depiction of the CNs. 3D T2 images improved depiction of inner brain structure in comparison to T2 images at 3 T. Although the 7-T SWI sequence provided improved contrast to some inner structures, extended areas were influenced by artifacts due to image disturbances from susceptibility differences. CONCLUSIONS: Seven-tesla imaging of basal brain areas is feasible and might have significant impact on detection and diagnosis in patients with specific diseases, e.g., trigeminal pain related to affection of the nerve root. Some inner brain stem structures can be depicted at 3 T, but certain sequences at 7 T, in particular 3D SPACE T2, are superior in producing anatomical in vivo images of deep brain stem structures.


Subject(s)
Algorithms , Brain Stem/anatomy & histology , Cranial Nerves/anatomy & histology , Diffusion Tensor Imaging/methods , Image Interpretation, Computer-Assisted/methods , Nerve Fibers, Myelinated/ultrastructure , Adult , Female , Humans , Image Enhancement/methods , Male , Reference Values , Reproducibility of Results , Sensitivity and Specificity , Signal Processing, Computer-Assisted , Young Adult
3.
Eur J Med Res ; 18: 30, 2013 Sep 03.
Article in English | MEDLINE | ID: mdl-24004903

ABSTRACT

BACKGROUND: With the Bonebridge, a new bone-anchored hearing aid has been available since March 2012. The objective of the study was to analyse the visualisation of the implant itself as well as its impact on the representation of the bony structures of the petrosal bone in CT, MRI and cone beam CT (CBCT). METHODS: The Bonebridge was implanted unilaterally in two completely prepared human heads. The radiological imaging by means of CBCT, 64-slice CT, 1.5-T and 3.0-T MRI was conducted both preoperatively and postoperatively. The images were subsequently evaluated from both the ENT medical and nd radiological perspectives. RESULTS: As anticipated, no visualisation of the implant or of the petrosal bones could be realised on MRI because of the interactive technology and the magnet artefact. In contrast, an excellent evaluability of the implant itself as well as of the surrounding neurovascular structures (sinus sigmoideus, skull base, middle ear, inner ear, inner auditory canal) was exhibited in both the CT and in the CBCT. CONCLUSION: The Bonebridge can be excellently imaged with the radiological imaging technologies of CT and CBCT. In the process, CBCT shows discrete advantages in comparison with CT. No relevant restrictions in image quality in the evaluation of the bony structures of the petrosal bones could be seen.


Subject(s)
Cone-Beam Computed Tomography , Hearing Aids , Humans , Imaging, Three-Dimensional , Intraoperative Care , Prostheses and Implants
4.
Forensic Sci Int ; 228(1-3): 179.e1-7, 2013 May 10.
Article in English | MEDLINE | ID: mdl-23473543

ABSTRACT

INTRODUCTION: The objective of this article was to explore age-at-death estimates in forensic medicine, which were methodically based on age-dependent, radiologically defined bone-density (HC) decay and which were investigated with a standard clinical computed tomography (CT) system. Such density decay was formerly discovered with a high-resolution flat-panel CT in the skulls of adult females. The development of a standard CT methodology for age estimations--with thousands of installations--would have the advantage of being applicable everywhere, whereas only few flat-panel prototype CT systems are in use worldwide. METHODS: A Multi-Slice CT scanner (MSCT) was used to obtain 22,773 images from 173 European human skulls (89 male, 84 female), taken from a population of patients from the Department of Neuroradiology at the University Hospital Giessen and Marburg during 2010 and 2011. An automated image analysis was carried out to evaluate HC of all images. The age dependence of HC was studied by correlation analysis. The prediction accuracy of age-at-death estimates was calculated. Computer simulations were carried out to explore the influence of noise on the accuracy of age predictions. RESULTS: Human skull HC values strongly scatter as a function of age for both sexes. Adult male skull bone-density remains constant during lifetime. Adult female HC decays during lifetime, as indicated by a correlation coefficient (CC) of -0.53. Prediction errors for age-at-death estimates for both of the used scanners are in the range of ±18 years at a 75% confidence interval (CI). Computer simulations indicate that this is the best that can be expected for such noisy data. CONCLUSIONS: Our results indicate that HC-decay is indeed present in adult females and that it can be demonstrated both by standard and by high-resolution CT methods, applied to different subject groups of an identical population. The weak correlation between HC and age found by both CT methods only enables a method to estimate age-at-death with limited practical relevance since the errors of the estimates are large. Computer simulations clearly indicate that data with less noise and CCs in the order of -0.97 or less would be necessary to enable age-at-death estimates with an accuracy of ±5 years at a 75% CI.


Subject(s)
Age Determination by Skeleton/methods , Bone Density , Skull/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Computer Simulation , Female , Forensic Anthropology , Humans , Image Processing, Computer-Assisted , Infant , Infant, Newborn , Linear Models , Male , Middle Aged , Multidetector Computed Tomography , Sex Characteristics , Skull/anatomy & histology , Tomography, X-Ray Computed , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...