1.
Wearable Technol ; 4: e4, 2023.
Article in English | MEDLINE | ID: mdl-38487777

ABSTRACT

The development of wearable technology, which enables motion tracking analysis for human movement outside the laboratory, can improve awareness of personal health and performance. This study used a wearable smart sock prototype to track foot-ankle kinematics during gait movement. Multivariable linear regression and two deep learning models, including long short-term memory (LSTM) and convolutional neural networks, were trained to estimate the joint angles in sagittal and frontal planes measured by an optical motion capture system. Participant-specific models were established for ten healthy subjects walking on a treadmill. The prototype was tested at various walking speeds to assess its ability to track movements for multiple speeds and generalize models for estimating joint angles in sagittal and frontal planes. LSTM outperformed other models with lower mean absolute error (MAE), lower root mean squared error, and higher R-squared values. The average MAE score was less than 1.138° and 0.939° in sagittal and frontal planes, respectively, when training models for each speed and 2.15° and 1.14° when trained and evaluated for all speeds. These results indicate wearable smart socks to generalize foot-ankle kinematics over various walking speeds with relatively low error and could consequently be used to measure gait parameters without the need for a lab-constricted motion capture system.

2.
Sensors (Basel) ; 22(21)2022 Oct 25.
Article in English | MEDLINE | ID: mdl-36365868

ABSTRACT

Motion capture is the current gold standard for assessing movement of the human body, but laboratory settings do not always mimic the natural terrains and movements encountered by humans. To overcome such limitations, a smart sock that is equipped with stretch sensors is being developed to record movement data outside of the laboratory. For the smart sock stretch sensors to provide valuable feedback, the sensors should have durability of both materials and signal. To test the durability of the stretch sensors, the sensors were exposed to high-cycle fatigue testing with simultaneous capture of the capacitance. Following randomization, either the fatigued sensor or an unfatigued sensor was placed in the plantarflexion position on the smart sock, and participants were asked to complete the following static movements: dorsiflexion, inversion, eversion, and plantarflexion. Participants were then asked to complete gait trials. The sensor was then exchanged for either an unfatigued or fatigued plantarflexion sensor, depending upon which sensor the trials began with, and each trial was repeated by the participant using the opposite sensor. Results of the tests show that for both the static and dynamic movements, the capacitive output of the fatigued sensor was consistently higher than that of the unfatigued sensor suggesting that an upwards drift of the capacitance was occurring in the fatigued sensors. More research is needed to determine whether stretch sensors should be pre-stretched prior to data collection, and to also determine whether the drift stabilizes once the cyclic softening of the materials comprising the sensor has stabilized.


Subject(s)
Ankle , Movement , Humans , Ankle Joint , Motion , Gait , Biomechanical Phenomena
3.
Sensors (Basel) ; 21(16)2021 Aug 08.
Article in English | MEDLINE | ID: mdl-34450790

ABSTRACT

There is scarce research into the use of Strive Sense3 smart compression shorts to measure external load with accelerometry and muscle load (i.e., muscle activations) with surface electromyography in basketball. Sixteen external load and muscle load variables were measured from 15 National Collegiate Athletic Association Division I men's basketball players with 1137 session records. The data were analyzed for player positions of Centers (n = 4), Forwards (n = 4), and Guards (n = 7). Nonparametric bootstrapping was used to find significant differences between training and game sessions. Significant differences were found in all variables except Number of Jumps and all muscle load variables for Guards, and all variables except Muscle Load for Forwards. For Centers, the Average Speed, Average Max Speed, and Total Hamstring, Glute, Left, and Right Muscle variables were significantly different (p < 0.05). Principal component analysis was conducted on the external load variables. Most of the variance was explained within two principal components (70.4% in the worst case). Variable loadings of principal components for each position were similar during training but differed during games, especially for the Forward position. Measuring muscle activation provides additional information in which the demands of each playing position can be differentiated during training and competition.


Subject(s)
Athletic Performance , Basketball , Humans , Male , Muscles , Physical Phenomena , Principal Component Analysis
4.
Sensors (Basel) ; 19(16)2019 Aug 10.
Article in English | MEDLINE | ID: mdl-31405180

ABSTRACT

The linearity of soft robotic sensors (SRS) was recently validated for movement angle assessment using a rigid body structure that accurately depicted critical movements of the foot-ankle complex. The purpose of this study was to continue the validation of SRS for joint angle movement capture on 10 participants (five male and five female) performing ankle movements in a non-weight bearing, high-seated, sitting position. The four basic ankle movements-plantar flexion (PF), dorsiflexion (DF), inversion (INV), and eversion (EVR)-were assessed individually in order to select good placement and orientation configurations (POCs) for four SRS positioned to capture each movement type. PF, INV, and EVR each had three POCs identified based on bony landmarks of the foot and ankle while the DF location was only tested for one POC. Each participant wore a specialized compression sock where the SRS could be consistently tested from all POCs for each participant. The movement data collected from each sensor was then compared against 3D motion capture data. R-squared and root-mean-squared error averages were used to assess relative and absolute measures of fit to motion capture output. Participant robustness, opposing movements, and gender were also used to identify good SRS POC placement for foot-ankle movement capture.


Subject(s)
Ankle Joint/physiology , Foot Joints/physiology , Wearable Electronic Devices , Adult , Biomechanical Phenomena , Female , Humans , Male , Movement/physiology , Young Adult