1.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38989913

ABSTRACT

AIMS: Transvenous lead extraction (TLE) is potentially complicated by significant tricuspid valve regurgitation increase (TRI). However, there are limited data on the effect of the bidirectional rotational mechanical sheaths on significant TRI. The aim of the present study was to investigate the rate of significant changes in tricuspid regurgitation (TR) severity following mechanical rotational TLE and their outcomes. METHODS AND RESULTS: In 158 patients (mean age 66 ± 16.9 years) undergoing mechanical rotational TLE, acute changes in TR severity were assessed by echocardiography evaluation. A significant acute TRI was defined as an increase of at least one grade with a post-extraction severity at least moderate. A total of 290 leads were extracted (mean implant duration, 93 ± 65 months). Significant TRI was noted in 5.7% of patients, and it was linked to tricuspid valve damage, TLE infection indication, and longer lead implant duration. Univariate predictors of significant TRI included implant duration of all leads [odds ratio (OR) 1.01; 95% confidence interval (CI) 1.003-1.018; P = 0.001] and right ventricular leads (OR 1.01; 95% CI 1.004-1.017; P = 0.002). Severe increase of TR following TLE was an independent predictor of mortality [hazard ratio (HR) 5.20; 95% CI 1.44-18.73; P = 0.012 ] along with severe systolic dysfunction (HR 2.37; 95% CI 1.01-5.20; P = 0.032), and systemic infection (HR 2.28; 95% CI 1.06-4.89; P = 0.035). CONCLUSION: Significant TRI was detected in 5.7% of patients following transvenous rotational mechanical lead extraction. The duration of lead implantation emerged as the sole predictor of significant TRI. Physicians engaged in TLE should exercise greater vigilance for this potential complication.


Subject(s)
Defibrillators, Implantable , Device Removal , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/etiology , Male , Female , Device Removal/adverse effects , Aged , Middle Aged , Defibrillators, Implantable/adverse effects , Aged, 80 and over , Severity of Illness Index , Risk Factors , Treatment Outcome , Pacemaker, Artificial/adverse effects , Retrospective Studies , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve/physiopathology , Time Factors
3.
JACC Clin Electrophysiol ; 10(4): 670-681, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38340116

ABSTRACT

BACKGROUND: Mitral valve prolapse (MVP) may be associated with ventricular arrhythmias (VA) even in the absence of significant valvular regurgitation. Curling, mitral annulus disjunction (MAD) and myocardial fibrosis (late gadolinium enhancement [LGE]) may account for arrhythmogenesis. OBJECTIVES: This study investigated the determinants of VA in patients with MVP without significant regurgitation. METHODS: This study included 108 patients with MVP (66 female; median age: 48 years) without valve regurgitation. All patients underwent 12-lead electrocardiography, 12-lead 24-hour electrocardiographic Holter monitoring, exercise stress test, and cardiac magnetic resonance. Patients were divided into 2 groups (arrhythmic and no-arrhythmic MVP), according to the presence of VA with a right bundle branch block pattern. RESULTS: The 62 patients (57%) with arrhythmic MVP showed: 1) higher MAD (median length: 6.0 vs 3.2 mm; P = 0.017); 2) higher prevalence of curling (79% vs 52%; P = 0.012); and 3) higher prevalence of left ventricular LGE (79% vs 52%; P = 0.012). Mediation analysis showed that curling had both a direct (P = 0.03) and indirect effect mediated by LGE (P = 0.04) on VA, whereas the association between MAD and VA was completely mediated by LGE. Patients with severe VA showed more pronounced morphofunctional alterations, in terms of MAD (7.0 vs 4.6 mm; P = 0.004) and presence and severity of curling (respectively, 91% vs 64%; P = 0.010; and 4 vs 3 mm; P = 0.004), compared to those without severe VA. CONCLUSIONS: In patients with MVP the occurrence of VA with right bundle branch block morphology is the expression of more severe morphologic, mechanical, and tissue alterations. Curling has both a direct and an indirect effect on VA.


Subject(s)
Arrhythmias, Cardiac , Mitral Valve Prolapse , Humans , Female , Middle Aged , Mitral Valve Prolapse/physiopathology , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/complications , Male , Adult , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/epidemiology , Electrocardiography , Magnetic Resonance Imaging , Electrocardiography, Ambulatory , Exercise Test , Aged
4.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38272130

ABSTRACT

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Subject(s)
Defibrillators, Implantable , Heart Failure , Heart-Assist Devices , Pacemaker, Artificial , Adult , Female , Humans , Male , Middle Aged , Defibrillators, Implantable/adverse effects , Electric Countershock/adverse effects , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/complications , Heart-Assist Devices/adverse effects , Pacemaker, Artificial/adverse effects , Treatment Outcome
5.
Int J Cardiovasc Imaging ; 40(2): 275-285, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38141098

ABSTRACT

PURPOSE: Left ventricular (LV) fibrosis has a key role in arrhythmogenesis in patients with mitral valve prolapse (MVP). Cardiac magnetic resonance identifies LV fibrosis by using late gadolinium enhancement (LGE) technique. LGE assessment and quantification in patients with MVP lacks of standardization protocols. METHODS: 66 MVP patients with normal systolic function and without significant regurgitation were enrolled. Semi-automated gray-scale thresholding techniques using full width at half maximum (FWHM) and 2, 3 and 5 standard deviation (SD) above the remote myocardium were used and compared with the visual assessment, considered as the gold standard. RESULTS: LGE was identified in 41 MVP patients (62%) and quantified. The mean quantity of LGE visually assessed was 2.40 ± 1.07% or 1.40 ± 0.82 g. With FWHM, LGE resulted 3.56 ± 1.23% or 1.99 ± 1.13 g. Using thresholding, the mean LGE quantity was 9.2 ± 3.1% or 4.82 ± 2.28 g for 2-SD, 5.72 ± 1.75% or 3.06 ± 1.47 g for 3-SD and 2.36 ± 0.99% or 1.29 ± 0.79 g for 5-SD. The 5-SD measurement in percentage demonstrated a good correlation with LGE quantification visually assessed (2.40 ± 1.07 vs. 2.363 ± 0.9909, p = 0.543). When compared with the gold standard, the 5-SD threshold quantification, both in percentage and in grams, revealed the least intra-observer (respectively, ICC: 0.976 and 0.966) and inter-observer variability (respectively ICC: 0.948 and 0.935). CONCLUSION: The 5-SD gray-scale threshold technique in percentage revealed the best correlation with the visual assessment and an optimal reproducibility in MVP patient.


Subject(s)
Mitral Valve Prolapse , Humans , Mitral Valve Prolapse/complications , Mitral Valve Prolapse/diagnostic imaging , Contrast Media , Reproducibility of Results , Predictive Value of Tests , Gadolinium , Fibrosis , Magnetic Resonance Spectroscopy
6.
J Interv Card Electrophysiol ; 67(4): 697-698, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38114717

ABSTRACT

A 74-year-old man who recently undergone a definitive pacemaker implantation with an apical septal active lead fixation presented to the emergency department because of a new-onset acute chest pain that began soon after cough episodes. Pacemaker interrogation reported an increased bipolar pacing threshold (3.25 V at 1 ms). Contrast-enhanced chest CT scan and percutaneous angiography revealed the sequential perforation of the right ventricular apex and the left internal mammary artery by the ventricular pacemaker lead. Successful percutaneous embolization of the LIMA, blood transfusion and thoracentesis were then performed, and the patient subsequently underwent a percutaneous ventricular lead extraction followed by re-implantation, with an uneventful follow-up after 2 years. This unique case report highlights a potential rare complication of the active fixation of the ventricular lead at the apical interventricular septum and should lead the clinicians to keep in mind right ventricular perforation, even without cardiac tamponade, in patients presenting for cardio-pulmonary symptoms soon after pacemaker implantation.


Subject(s)
Chest Pain , Cough , Hemothorax , Pacemaker, Artificial , Humans , Male , Aged , Pacemaker, Artificial/adverse effects , Chest Pain/etiology , Hemothorax/etiology , Hemothorax/diagnostic imaging , Hemothorax/therapy , Cough/etiology , Device Removal , Acute Disease , Treatment Outcome , Electrodes, Implanted/adverse effects , Embolization, Therapeutic/methods
7.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 25.
Article in English | MEDLINE | ID: mdl-38132643

ABSTRACT

Unstable and symptomatic complete atrioventricular block represents a potentially fatal condition that requires prompt therapy while waiting for definitive pacemaker implantation. Although transcutaneous pacing is included in acute management, it could be a difficult approach due to its painfulness and the occasional failure of mechanical capture. Drug therapy is a feasible choice, and current guidelines encompass the use of atropine, dopamine, or epinephrine. Isoprenaline has never been investigated in this setting, and no specific indication of its use has been provided despite its potentially more favorable pharmacological profile. The study population included a consecutive series of patients who presented to the emergency department because of unstable third-degree atrioventricular block and were treated with either isoprenaline or dopamine infusion while waiting for definitive pacemaker implantation. Asymptomatic patients or those with reversible causes of complete atrioventricular block were excluded. The clinical response to the drug was deemed poor if, despite achieving a full drug dose, patients remained symptomatic and/or with hemodynamic instability, ventricular rate and rhythm did not improve or worsened, including if ventricular arrhythmias or asystolic pauses and/or irrepressible nausea/vomiting occurred. Isoprenaline infusion has proved to be safe and tolerated with no arrhythmia induction or hypotensive issues. Isoprenaline has also proven to be more satisfactory in achieving an effective clinical response in 84% of patients rather than dopamine (31%, p < 0.001), reducing the need for temporary artificial pacing. Our data point out the efficacy and safety of isoprenaline infusion and its greater tolerability over dopamine in the acute management of unstable third-degree AV block while waiting for definitive pacemaker implantation.

8.
Rev Cardiovasc Med ; 23(10): 335, 2022 Oct.
Article in English | MEDLINE | ID: mdl-39077127

ABSTRACT

Arrhythmogenic cardiomyopathy (ACM) is a rare heart muscle disease characterized by a progressive fibro-fatty myocardial replacement, ventricular arrhythmias, and increased risk of sudden cardiac death. The first diagnostic criteria were proposed by an International Task Force of experts in 1994 and revised in 2010. At that time, ACM was mainly considered a right ventricle disease, with left ventricle involvement only in the late stages. Since 2010, several pathological and clinical studies using cardiac magnetic resonance (CMR) imaging have allowed to understand the phenotypic expression of the disease and to reach the current idea that ACM may affect both ventricles. Indeed, left ventricular involvement may parallel or exceed right ventricular involvement. The main limitations of the 2010 criteria included the poor sensitivity for left ventricular involvement and the lack of inclusion of tissue characterization by CMR. The 2020 International criteria (the Padua criteria) were developed to overcome these shortcomings. The most important innovations are the introduction of a set of criteria for identifying left ventricular variants and the use of CMR for tissue characterization. Moreover, criteria for right ventricular involvement were also updated taking into account new evidence. According to the number of criteria for right and/or left ventricular involvement, the 2020 Padua criteria allows diagnosing three ACM phenotypic variants: right-dominant, biventricular and left-dominant. This review discusses the evolving approach to diagnosis of ACM, from the 1994 International Criteria to the 2020 Padua criteria.