1.
Br J Radiol ; 82(976): 303-12, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19124567

ABSTRACT

For 318 patients in 8 different Belgian hospitals, the entire skin-dose distribution was mapped using a grid of 70 thermoluminescence dosimeters per patient, allowing an accurate determination of the maximum skin dose (MSD). Dose-area product (DAP) values, exposure parameters and geometry, together with procedure, patient and cardiologist characteristics, were also registered. Procedures were divided into two groups: diagnostic procedures (coronary angiography) and therapeutic procedures (dilatation, stent, combined procedures (e.g. coronary angiography + dilatation + stent)). The mean value of the MSD was 0.310 Gy for diagnostic and 0.699 Gy for therapeutic procedures. The most critical projection for receiving the MSD is the LAO90 (left anterior oblique) geometry. In 3% of cases, the MSD exceeded the 2 Gy dose threshold for deterministic effects. Action levels in terms of DAP values as the basis for a strategy for follow-up of patients for deterministic radiation skin effects were derived from measured MSD and cumulative DAP values. Two DAP action levels are proposed. A first DAP action level of 125 Gy cm(2) corresponding to the dose threshold of 2 Gy would imply an optional radiopathological follow-up depending on the cardiologist's decision. A second DAP action level of 250 Gy cm(2) corresponding to the 3 Gy skin dose would imply a systematic follow-up. Dose reference levels - 71.3 Gy cm(2) for diagnostic and 106.0 Gy cm(2) for therapeutic procedures - were derived from the 75 percentile of the DAP distributions. As a conclusion, we propose that total DAP is registered in patient's record file, as it can serve to improve the follow-up of patients for radiation-induced skin injuries.


Subject(s)
Cardiac Catheterization/methods , Radiation Injuries/prevention & control , Radiation Monitoring/methods , Radiography, Interventional/adverse effects , Skin/radiation effects , Adult , Aged , Aged, 80 and over , Clinical Protocols , Coronary Angiography/methods , Female , Humans , Male , Maximum Tolerated Dose , Middle Aged , Radiation Dosage , Reference Standards , Risk Factors
2.
Pacing Clin Electrophysiol ; 23(12): 2073-7, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11202250

ABSTRACT

The Autocapture feature, implemented in the Microny and Regency pacemakers of St. Jude Medical, continuously controls the effectiveness of ventricular stimulation by detection of the evoked response. Proper sensing of this signal depends on the magnitude of the polarization, which should be minimal. Therefore, the conjunctive use of low polarization electrodes is recommended. Further, the pacing impulse of these pacemakers has a biphasic waveform consisting of a stimulus followed by a fast discharge pulse. This study compares polarization of a modified pacing impulse with the default pacing impulse, and its effect on the ability to activate the Autocapture function when used with different types of electrodes. In 45 patients, acute measurements of the polarization and the evoked response were performed at random on the modified pacing impulses of a custom designed Regency and on the default stimuli of a standard Regency. The following bipolar leads were used: 20 Medtronic 4024 CapSure, 12 Pacesetter 1450T, and 13 Pacesetter 1470T. Using the default pacing impulse, polarization and evoked response were significantly larger with the Medtronic 4024 CapSure compared to the low polarization leads. The polarization to evoked response ratio was more frequently acceptable for activation of the Autocapture with the Pacesetter leads. In all leads the modified pacing impulse was characterized by significantly smaller polarization with the most prominent reduction in the Medtronic 4024 CapSure. The differences in the pacing impulse did not affect the evoked response. With the programmability of the fast discharge pulse, the requirements to activate the Autocapture function were fulfilled in 29 (94%) of 31 patients with the modified pacing impulse, compared to 22 (71%) of 31 patients with the standard pacing impulse. The modified pacing impulse decreased the "polarization to evoked response" ratio, and by that improved the conditions for activation of the Autocapture function.


Subject(s)
Cardiac Pacing, Artificial/methods , Heart Ventricles/innervation , Pacemaker, Artificial , Algorithms , Electrophysiology , Equipment Safety , Evoked Potentials , Humans
3.
Acta Cardiol ; 46(5): 577-82, 1991.
Article in English | MEDLINE | ID: mdl-1789052

ABSTRACT

A three-generation family is presented in which several relatives died from or are affected by idiopathic dilated cardiomyopathy (IDC). The transmission pattern is autosomal dominant. Although familial instances of IDC have been reported the proportion of familial cases tends to be underestimated. Moreover, different transmission patterns have been associated with IDC. This report adds further evidence to the fact that an autosomal dominant form of IDC clearly exists and that early screening of asymptomatic first degree relatives is mandatory for accurate genetic counselling of patients and their family members.


Subject(s)
Cardiomyopathy, Dilated/genetics , Adult , Humans , Male , Pedigree