Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Microsc Microanal ; 18(2): 399-405, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22284855

ABSTRACT

In conventional X-ray microtomography (µCT), the three-dimensional (3D) distribution of the attenuation coefficient of X-rays is measured and reconstructed in a 3D volume. As spatial resolution increases, the refraction of X-rays becomes a significant phenomenon in the imaging process. Although this so-called phase contrast was initially a cumbersome feature in lab-based µCT, special phase retrieval algorithms were developed to exploit these effects. Clear advantages in terms of visualization and analysis can be seen when phase retrieval algorithms are applied, including an increased signal-to-noise ratio. In this work, this is demonstrated both on simulated and measured data.

2.
Microsc Microanal ; 17(2): 252-63, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21281537

ABSTRACT

Three-dimensional (3D) analysis is an essential tool to obtain quantitative results from 3D datasets. Considerable progress has been made in 3D imaging techniques, resulting in a growing need for more flexible, complete analysis packages containing advanced algorithms. At the Centre for X-ray Tomography of the Ghent University (UGCT), research is being done on the improvement of both hardware and software for high-resolution X-ray computed tomography (CT). UGCT collaborates with research groups from different disciplines, each having specific needs. To meet these requirements the analysis software package, Morpho+, was developed in-house. Morpho+ contains an extensive set of high-performance 3D operations to obtain object segmentation, separation, and parameterization (orientation, maximum opening, equivalent diameter, sphericity, connectivity, etc.), or to extract a 3D geometrical representation (surface mesh or skeleton) for further modeling. These algorithms have a relatively short processing time when analyzing large datasets. Additionally, Morpho+ is equipped with an interactive and intuitive user interface in which the results are visualized. The package allows scientists from various fields to obtain the necessary quantitative results when applying high-resolution X-ray CT as a research tool to the nondestructive investigation of the microstructure of materials.

3.
Ann Bot ; 107(2): 293-302, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21131386

ABSTRACT

BACKGROUND AND AIMS: Density is a crucial variable in forest and wood science and is evaluated by a multitude of methods. Direct gravimetric methods are mostly destructive and time-consuming. Therefore, faster and semi- to non-destructive indirect methods have been developed. METHODS: Profiles of wood density variations with a resolution of approx. 50 µm were derived from one-dimensional resistance drillings, two-dimensional neutron scans, and three-dimensional neutron and X-ray scans. All methods were applied on Terminalia superba Engl. & Diels, an African pioneer species which sometimes exhibits a brown heart (limba noir). KEY RESULTS: The use of X-ray tomography combined with a reference material permitted direct estimates of wood density. These X-ray-derived densities overestimated gravimetrically determined densities non-significantly and showed high correlation (linear regression, R(2) = 0·995). When comparing X-ray densities with the attenuation coefficients of neutron scans and the amplitude of drilling resistance, a significant linear relation was found with the neutron attenuation coefficient (R(2) = 0·986) yet a weak relation with drilling resistance (R(2) = 0·243). When density patterns are compared, all three methods are capable of revealing the same trends. Differences are mainly due to the orientation of tree rings and the different characteristics of the indirect methods. CONCLUSIONS: High-resolution X-ray computed tomography is a promising technique for research on wood cores and will be explored further on other temperate and tropical species. Further study on limba noir is necessary to reveal the causes of density variations and to determine how resistance drillings can be further refined.


Subject(s)
Terminalia/growth & development , Tomography, X-Ray Computed/methods , Trees/growth & development , Biomechanical Phenomena , Conservation of Natural Resources , Densitometry , Wood/growth & development
4.
IEEE Trans Image Process ; 19(9): 2419-27, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20350850

ABSTRACT

In computed tomography, the application of iterative reconstruction methods in practical situations is impeded by their high computational demands. Especially in high resolution X-ray computed tomography, where reconstruction volumes contain a high number of volume elements (several giga voxels), this computational burden prevents their actual breakthrough. Besides the large amount of calculations, iterative algorithms require the entire volume to be kept in memory during reconstruction, which quickly becomes cumbersome for large data sets. To overcome this obstacle, we present a novel multiresolution reconstruction, which greatly reduces the required amount of memory without significantly affecting the reconstructed image quality. It is shown that, combined with an efficient implementation on a graphical processing unit, the multiresolution approach enables the application of iterative algorithms in the reconstruction of large volumes at an acceptable speed using only limited resources.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods , Phantoms, Imaging
5.
Philos Trans R Soc Lond B Biol Sci ; 365(1543): 1093-8, 2010 Apr 12.
Article in English | MEDLINE | ID: mdl-20194171

ABSTRACT

Darwin's finches have radiated from a common ancestor into 14 descendent species, each specializing on distinct food resources and evolving divergent beak forms. Beak morphology in the ground finches (Geospiza) has been shown to evolve via natural selection in response to variation in food type, food availability and interspecific competition for food. From a mechanical perspective, however, beak size and shape are only indirectly related to birds' abilities to crack seeds, and beak form is hypothesized to evolve mainly under selection for fracture avoidance. Here, we test the fracture-avoidance hypothesis using finite-element modelling. We find that across species, mechanical loading is similar and approaches reported values of bone strength, thus suggesting pervasive selection on fracture avoidance. Additionally, deep and wide beaks are better suited for dissipating stress than are more elongate beaks when scaled to common sizes and loadings. Our results illustrate that deep and wide beaks in ground finches enable reduction of areas with high stress and peak stress magnitudes, allowing birds to crack hard seeds while limiting the risk of beak failure. These results may explain strong selection on beak depth and width in natural populations of Darwin's finches.


Subject(s)
Beak/anatomy & histology , Feeding Behavior , Finches/anatomy & histology , Finches/genetics , Selection, Genetic , Animals , Biomechanical Phenomena/genetics , Ecuador , Finite Element Analysis
6.
J Opt Soc Am A Opt Image Sci Vis ; 26(4): 890-4, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19340263

ABSTRACT

When a very-low-absorbing sample is scanned at an x-ray computed tomography setup with a microfocus x-ray tube and a high-resolution detector, the obtained projection images contain not only absorption contrast but also phase contrast. While images without a phase signal can be reconstructed very well, such mixed phase and absorption images give rise to severe artifacts in the reconstructed slices. A method is described that applies a correction to these mixed projections to remove the phase signal. These corrected images can then be processed using a standard filtered backprojection algorithm to obtain reconstructions with only few or no phase artifacts. This new method, which we call the Bronnikov-aided correction (BAC), can be used in a broad variety of applications and without much additional effort. It is tested on a biological and a pharmaceutical sample, and results are evaluated and discussed by comparing them with those of conventional reconstruction methods.

SELECTION OF CITATIONS
SEARCH DETAIL