1.
Exp Cell Res ; 376(1): 58-66, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30660619

ABSTRACT

Wound closure, as a result of collective cell growth, is an essential biological response to injury. In the field of vascular biology, the response of vascular smooth muscle cells (SMCs) and endothelial cells (ECs) to injury and substrate surface is important in therapeutic clinical treatment interventions such as angioplasty and atherectomy. Specifically, the mechanism by which cells close wounds (i.e. proliferation versus migration) in response to injury stimuli is of interest to better modulate recurrent vascular stenosis, prevent thrombus formation, occlusion, and life-threatening cardiovascular events. Here, we examine growth extent and temporal sequence of events following wound or gap introduction to a confluent monolayer of vascular SMCs or ECs. Significant differences in the preferred mechanisms of these cells to close wounds or gaps were observed; after 48 h, 73% of SMC wound closure was observed to be due to proliferation, while 75% of EC wound closure resulted from migration. These mechanisms were further modulated via addition or removal of extracellular matrix substrate and injury, with ECs more responsive to substrate composition and less to injury, in comparison to SMCs. Our results indicate that ECs and SMCs heal wounds differently, and that the time and mode of injury and associated substrate surface all impact this response.


Subject(s)
Cell Movement/genetics , Cell Proliferation/physiology , Extracellular Matrix/genetics , Wound Healing/genetics , Angioplasty , Atherectomy , Cell Movement/physiology , Cell Proliferation/genetics , Endothelial Cells/metabolism , Endothelial Cells/pathology , Extracellular Matrix/pathology , Humans , Myocytes, Smooth Muscle/metabolism , Myocytes, Smooth Muscle/pathology , Primary Cell Culture , Wound Healing/physiology
2.
Artif Organs ; 41(7): E52-E65, 2017 Jul.
Article in English | MEDLINE | ID: mdl-27935084

ABSTRACT

With the growth and diversity of mechanical circulatory support (MCS) systems entering clinical use, a need exists for a robust mock circulation system capable of reliably emulating and reproducing physiologic as well as pathophysiologic states for use in MCS training and inter-device comparison. We report on the development of such a platform utilizing the SynCardia Total Artificial Heart and a modified Donovan Mock Circulation System, capable of being driven at normal and reduced output. With this platform, clinically relevant heart failure hemodynamics could be reliably reproduced as evidenced by elevated left atrial pressure (+112%), reduced aortic flow (-12.6%), blunted Starling-like behavior, and increased afterload sensitivity when compared with normal function. Similarly, pressure-volume relationships demonstrated enhanced sensitivity to afterload and decreased Starling-like behavior in the heart failure model. Lastly, the platform was configured to allow the easy addition of a left ventricular assist device (HeartMate II at 9600 RPM), which upon insertion resulted in improvement of hemodynamics. The present configuration has the potential to serve as a viable system for training and research, aimed at fostering safe and effective MCS device use.


Subject(s)
Computer Simulation , Heart Failure/physiopathology , Heart, Artificial , Heart/physiopathology , Hemodynamics , Models, Cardiovascular , Atrial Pressure , Equipment Design , Heart-Assist Devices , Humans , Ventricular Function, Left
3.
J Biol Eng ; 9: 19, 2015.
Article in English | MEDLINE | ID: mdl-26473009

ABSTRACT

BACKGROUND: Cell migration is a vital process for growth and repair. In vitro migration assays, utilized to study cell migration, often rely on physical scraping of a cell monolayer to induce cell migration. The physical act of scrape injury results in numerous factors stimulating cell migration - some injury-related, some solely due to gap creation and loss of contact inhibition. Eliminating the effects of cell injury would be useful to examine the relative contribution of injury versus other mechanisms to cell migration. Cell exclusion assays can tease out the effects of injury and have become a new avenue for migration studies. Here, we developed two simple non-injury techniques for cell exclusion: 1) a Pyrex® cylinder - for outward migration of cells and 2) a polydimethylsiloxane (PDMS) insert - for inward migration of cells. Utilizing these assays smooth muscle cells (SMCs) and human umbilical vein endothelial cells (HUVECs) migratory behavior was studied on both polystyrene and gelatin-coated surfaces. RESULTS: Differences in migratory behavior could be detected for both smooth muscle cells (SMCs) and endothelial cells (ECs) when utilizing injury versus non-injury assays. SMCs migrated faster than HUVECs when stimulated by injury in the scrape wound assay, with rates of 1.26 % per hour and 1.59 % per hour on polystyrene and gelatin surfaces, respectively. The fastest overall migration took place with HUVECs on a gelatin-coated surface, with the in-growth assay, at a rate of 2.05 % per hour. The slowest migration occurred with the same conditions but on a polystyrene surface at a rate of 0.33 % per hour. CONCLUSION: For SMCs, injury is a dominating factor in migration when compared to the two cell exclusion assays, regardless of the surface tested: polystyrene or gelatin. In contrast, the migrating surface, namely gelatin, was a dominating factor for HUVEC migration, providing an increase in cell migration over the polystyrene surface. Overall, the cell exclusion assays - the in-growth and out-growth assays, provide a means to determine pure migratory behavior of cells in comparison to migration confounded by cell wounding and injury.

4.
ASAIO J ; 61(3): 274-81, 2015.
Article in English | MEDLINE | ID: mdl-25551416

ABSTRACT

The SynCardia total artificial heart (TAH) has emerged as an effective, life-saving biventricular replacement system for a wide variety of patients with end-stage heart failure. Although the clinical performance of the TAH is established, modern physiological characterization, in terms of elastance behavior and pressure-volume (PV) characterization has not been defined. Herein, we examine the TAH in terms of elastance using a nonejecting left ventricle, and then characterize the PV relation of the TAH by varying preload and afterload parameters using a Donovan Mock Circulatory System. We demonstrate that the TAH does not operate with time-varying elastance, differing from the human heart. Furthermore, we show that the TAH has a PV relation behavior that also differs from that of the human heart. The TAH does exhibit Starling-like behavior, with output increasing via preload-dependent mechanisms, without reliance on an alteration of inotropic state within the operating window of the TAH. Within our testing range, the TAH is insensitive to variations in afterload; however, this insensitivity has a limit, the limit being the maximum driving pressure of the pneumatic driver. Understanding the physiology of the TAH affords insight into the functional parameters that govern artificial heart behavior providing perspective on differences compared with the human heart.


Subject(s)
Heart, Artificial , Hemodynamics , Models, Cardiovascular , Humans
5.
J Cardiovasc Transl Res ; 7(9): 788-96, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25354999

ABSTRACT

The SynCardia total artificial heart (TAH) is the only Food and Drug Administration (FDA) approved device for replacing hearts in patients with congestive heart failure. It pumps blood via pneumatically driven diaphragms and controls the flow with mechanical valves. While it has been successfully implanted in more than 1300 patients, its size precludes implantation in smaller patients. This study's aim was to evaluate the viability of scaled-down TAHs by quantifying thrombogenic potentials from flow patterns. Simulations of systole were first conducted with stationary valves, followed by an advanced full-cardiac cycle model with moving valves. All the models included deforming diaphragms and platelet suspension in the blood flow. Flow stress accumulations were computed for the platelet trajectories and thrombogenic potentials were assessed. The simulations successfully captured complex flow patterns during various phases of the cardiac cycle. Increased stress accumulations, but within the safety margin of acceptable thrombogenicity, were found in smaller TAHs, indicating that they are clinically viable.


Subject(s)
Heart, Artificial , Hemodynamics/physiology , Platelet Activation/physiology , Equipment Design , Heart, Artificial/adverse effects , Hydrodynamics , Models, Biological , Stress, Mechanical , Thrombosis/etiology
SELECTION OF CITATIONS