Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
AJNR Am J Neuroradiol ; 33(4): 695-700, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22173748

ABSTRACT

BACKGROUND AND PURPOSE: DTI is increasingly being used as a measure to study tissue damage in several neurologic diseases. Our aim was to investigate the comparability of DTI measures between different MR imaging magnets and platforms. MATERIALS AND METHODS: Two healthy volunteers underwent DTI on five 3T MR imaging scanners (3 Trios and 2 Signas) by using a matched 33 noncollinear diffusion-direction pulse sequence. Within each subject, a total of 16 white matter (corpus callosum, periventricular, and deep white matter) and gray matter (cortical and deep gray) ROIs were drawn on a single image set and then were coregistered to the other images. Mean FA, ADC, and longitudinal and transverse diffusivities were calculated within each ROI. Concordance correlations were derived by comparing ROI DTI values among each of the 5 magnets. RESULTS: Mean concordance for FA was 0.96; for both longitudinal and transverse diffusivities, it was 0.93; and for ADC, it was 0.88. Mean scan-rescan concordance was 0.96-0.97 for all DTI measures. Concordance correlations within platforms were, in general, better than those between platforms for all DTI measures (mean concordance of 0.96). CONCLUSIONS: We found that a 3T magnet and high-angular-resolution pulse sequence yielded comparable DTI measurements across different MR imaging magnets and platforms. Our results indicate that FA is the most comparable measure across magnets, followed by individual diffusivities. The comparability of DTI measures between different magnets supports the feasibility of multicentered clinical trials by using DTI as an outcome measure.


Subject(s)
Brain/anatomy & histology , Diffusion Magnetic Resonance Imaging/instrumentation , Image Enhancement/instrumentation , Adult , Anisotropy , Equipment Design , Equipment Failure Analysis , Humans , Male , Ohio , Reproducibility of Results , Sensitivity and Specificity
2.
Magn Reson Med ; 42(1): 69-81, 1999 Jul.
Article in English | MEDLINE | ID: mdl-10398952

ABSTRACT

A method to tailor the view order to the reconstruction cycle is introduced for real-time MRI. It is well known that view sharing and oversampling central k-space views can improve the temporal resolution of gradient-echo pulse sequences. By ordering phase-encodes to synchronize k-space acquisition with the reconstruction cycle, apparent temporal resolution can match the frame rate with as few as one-fourth of the phase-encodes sampled per reconstruction. Spatial resolution is maintained by periodically updating high spatial frequencies. In addition to apparent temporal resolution, three other criteria for real-time imaging are identified and evaluated: display latency, dispersion, and frame-to-frame consistency. Latency is minimized by ordering views in a reverse-centric manner within each reconstruction interval, sampling high-energy views immediately prior to beginning reconstruction. Dispersion is kept low and consistent by synchronizing acquisition and reconstruction, thus avoiding poorly timed reconstruction instances. Real-time implementation demonstrates pulsatile time-of-flight blood signal enhancement in humans.


Subject(s)
Fluoroscopy/instrumentation , Image Processing, Computer-Assisted/instrumentation , Magnetic Resonance Imaging/instrumentation , Algorithms , Blood Flow Velocity/physiology , Computer Simulation , Echo-Planar Imaging/instrumentation , Equipment Design , Fourier Analysis , Humans , Image Enhancement/instrumentation , Phantoms, Imaging , Pulsatile Flow/physiology , Sensitivity and Specificity
3.
Magn Reson Med ; 41(4): 846-9, 1999 Apr.
Article in English | MEDLINE | ID: mdl-10332863

ABSTRACT

Magnetic resonance imaging allows significant freedom in selecting the orientation and position of a tomographic section. However, it can nonetheless be challenging to determine quickly and efficiently the correct parameters required to image a targeted anatomic structure that may lie at an oblique angle in the imaging volume. We describe a three-point tool in which a) the user interactively selects three points from an anatomic structure of interest during live MR fluoroscopy; b) adjustments to pulse sequence are calculated to image the tomographic section defined by the three points; and c) the section is then immediately imaged fluoroscopically. The tool allows quick localization of, for example, longitudinal images of specific arterial structures.


Subject(s)
Arteries/anatomy & histology , Magnetic Resonance Imaging/methods , Algorithms , Aorta, Thoracic/anatomy & histology , Carotid Arteries/anatomy & histology , Fluoroscopy/methods , Humans , Rotation , Tomography
4.
Magn Reson Med ; 40(1): 24-35, 1998 Jul.
Article in English | MEDLINE | ID: mdl-9660549

ABSTRACT

Arterial-phase three-dimensional (3D) contrast-enhanced MR angiograms of the carotid and vertebral arteries from their origins through the carotid bifurcations were obtained in 20 patients using acquisition times over 30 sec by using an MR fluoroscopy-triggered pulse sequence with elliptical centric view order. The typical pixel size was 0.8 mm (x) x 1.6 mm (y) x 1.5 mm (z), and 32-48 coronal slices were acquired. The fluoroscopic monitoring of bolus arrival was effective in 18 of the 20 cases; two failures were attributed directly to a poor choice of RF coil. To exploit peak arterial-to-venous contrast, the central 3D views were acquired first in the most compact time period possible for the given TR. For the 18 successfully triggered cases, arterial-phase 3D images were obtained with excellent venous suppression as demonstrated by an average internal jugular vein to common carotid signal enhancement ratio of only 0.05 +/- 0.04.


Subject(s)
Carotid Arteries/pathology , Fluoroscopy/methods , Magnetic Resonance Angiography/methods , Radiographic Image Enhancement/methods , Vascular Diseases/diagnosis , Vertebral Artery/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Carotid Arteries/diagnostic imaging , Contrast Media , Female , Fluoroscopy/instrumentation , Gadolinium , Heterocyclic Compounds , Humans , Magnetic Resonance Angiography/instrumentation , Male , Middle Aged , Organometallic Compounds , Sensitivity and Specificity , Vertebral Artery/diagnostic imaging
5.
Magn Reson Med ; 38(6): 1003-11, 1997 Dec.
Article in English | MEDLINE | ID: mdl-9402202

ABSTRACT

Multiple element surface coils are often used in clinical MRI to increase the image signal-to-noise ratio (S/N). Use of multicoils typically requires increased net sampling bandwidth and data processing for each coil element. A phase-alignment technique is described which combines the signals from all coil elements before image reconstruction, greatly relaxing the technical requirements of the standard multicoil methods. Hardware and software implementations allow reduction of the reconstruction requirement to that of a single coil. The hardware implementation additionally allows a significant reduction in the net sampling bandwidth. The method is applicable to high speed MRI techniques, as demonstrated in phantoms and volunteers.


Subject(s)
Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging
6.
Radiology ; 205(1): 137-46, 1997 Oct.
Article in English | MEDLINE | ID: mdl-9314975

ABSTRACT

PURPOSE: To determine the reliability of obtaining arterial-phase, contrast-material-enhanced three-dimensional (3D) magnetic resonance (MR) angiograms of the renal arteries by using a technique that combines two-dimensional real-time MR fluoroscopy and a 3D MR angiographic acquisition with elliptical centric view order. MATERIALS AND METHODS: Twenty-five consecutive patients suspected of having renal artery disease were evaluated with the fluoroscopically triggered technique by using a mean dose of 0.18 mmol/kg gadoteridol. Left renal vein suppression, inferior vena cava suppression, motion artifact, and image quality for depiction of the renal arteries were each evaluated on a five-point scale (1 = best). The findings were compared with those of another 25 consecutive patients who underwent conventional gadolinium-enhanced 3D MR angiography. RESULTS: The fluoroscopically triggered technique produced 4.6 times less left renal vein enhancement than did the conventional method (P < .01). With the fluoroscopically triggered technique, visualization of the renal arteries was adequate for diagnosis in 24 patients (96%) and the overall result (score of 1-3 for all criteria) was of good quality in 22 patients (88%). CONCLUSION: With this fluoroscopically triggered MR angiographic technique, high-quality, arterial phase, relatively motion immune angiograms can be routinely obtained.


Subject(s)
Contrast Media/administration & dosage , Fluoroscopy , Heterocyclic Compounds , Magnetic Resonance Angiography/methods , Organometallic Compounds , Renal Artery/pathology , Adolescent , Adult , Aged , Aorta, Abdominal/pathology , Female , Gadolinium/administration & dosage , Heterocyclic Compounds/administration & dosage , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Organometallic Compounds/administration & dosage , Renal Artery Obstruction/diagnosis , Renal Veins/pathology , Vena Cava, Inferior/pathology
7.
Magn Reson Med ; 36(4): 588-95, 1996 Oct.
Article in English | MEDLINE | ID: mdl-8892212

ABSTRACT

A technique is described for high speed interactive imaging of the heart with either white or black blood contrast. Thirty-two views of a segmented, magnetization-prepared gradient echo sequence are acquired during diastole. Using three-quarter partial Fourier sampling, data for a complete 128 x 128 image are acquired in three cardiac cycles. High speed reconstruction provides an image update of each cardiac cycle 159 ms after measurement. An independent graphical user interface facilitates interactive control of section localization and contrast by permitting pulse sequence parameter modification during scanning. The efficiency and image quality of the cardiac MR fluoroscopy technique were evaluated in 11 subjects. Compared with the conventional graphic prescription method, the cardiac fluoroscopy technique provides an approximate eightfold reduction in the time required to obtain subject-specific double oblique sections. Image quality for these scout acquisitions performed during free breathing was sufficient to identify small cardiac structures.


Subject(s)
Heart/anatomy & histology , Magnetic Resonance Imaging/methods , Coronary Angiography , Coronary Vessels/anatomy & histology , Electrocardiography , Fluoroscopy , Humans , Papillary Muscles/anatomy & histology , Papillary Muscles/diagnostic imaging
8.
Magn Reson Med ; 34(1): 11-6, 1995 Jul.
Article in English | MEDLINE | ID: mdl-7674888

ABSTRACT

To reduce respiratory blur and ghosts in 3D coronary imaging, a data acquisition scheme using consistent multiple breath-holds was implemented. A navigator echo was acquired and processed in real time to dynamically measure diaphragm position. This information was provided as a visual prompt to the patient to maintain consistency in breath-hold levels such that the variation range of diastolic heart position was less than 2 mm. Preliminary results indicate that this multiple breath-hold acquisition scheme, compared with acquisition under respiration, can significantly reduce blur and ghost artifacts in 3D coronary imaging.


Subject(s)
Artifacts , Coronary Vessels/anatomy & histology , Image Processing, Computer-Assisted , Magnetic Resonance Angiography/methods , Monitoring, Physiologic/methods , Respiration , Adult , Electrocardiography , Feedback , Female , Humans , Male , Middle Aged
9.
Magn Reson Med ; 34(1): 114-9, 1995 Jul.
Article in English | MEDLINE | ID: mdl-7674889

ABSTRACT

In applications where precise image section positioning is vital, the interactive section rotation and offset capabilities of interactive MRI should be valuable. However, due to the independent nature of these two adjustments, the desired structure may often not be visible in the image after a rotation. Valuable time is wasted during relocation. An algorithm is presented that automatically alters the section offset after a rotation to provide continuous viewing of a marked structure, greatly improving section orientation efficiency. The technique is illustrated in the determination of double oblique angulation for through-plane imaging of the portal vein. This algorithm is expected to prove useful in applications of interactive MRI requiring precise positioning.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Magnetic Resonance Angiography/methods , Magnetic Resonance Imaging/methods , Humans
10.
Magn Reson Med ; 30(4): 507-11, 1993 Oct.
Article in English | MEDLINE | ID: mdl-8255201

ABSTRACT

A technique is described that provides improved reproducibility of breath-holding for MR image acquisition by monitoring the superior-inferior (S/I) position of the diaphragm. The method incorporates detection of the level of inspiration using an MR signal, rapid display to the patient of diaphragm position to enable breath-hold adjustment, and triggering of image data acquisition once appropriate position is attained. The response time of the system is short, approximately 10 ms. Studies in six volunteers using this method demonstrate a considerable decrease in the S/I range of diaphragm position over 10 consecutive periods of suspended respiration. The mean range is 1.3 mm with the system, while it is 8.3 mm without using it. It is expected that this method will be of assistance in many abdominal and cardiothoracic studies that use breath-hold techniques.


Subject(s)
Magnetic Resonance Imaging/methods , Monitoring, Physiologic/methods , Respiration , Feedback , Humans
SELECTION OF CITATIONS