Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 58
Filter
1.
Article in English | MEDLINE | ID: mdl-38768759

ABSTRACT

INTRODUCTION: Suicide is the first cause of external death in Spain. International studies show frequent and varied health contacts in the months prior to suicide. There are hardly any studies on that phenomenon in this country. OBJECTIVE: To analyze health care use in the year prior to suicide between 2010 and 2018 in the Basque Country, as well as pharmacological prescriptions and psychiatric diagnoses received. METHODS: Retrospective descriptive study with all suicides registered by the Basque Institute of Legal Medicine (BILM) between 2010 and 2018. The records of the BILM and the Basque Health Service (Osakidetza) were cross-checked. RESULTS: 1526 suicides were analyzed. 74% had health contacts in the previous year. The use was higher in women (p<0.05) and in older ages (p<0001). Primary care was the most used specialty (58.8% the previous year and 7.1% the previous week), followed by Hospital Emergencies (50.3% and 10.2%) and Outpatient Medical Specialties (49% and 11.6%), especially Radiology. Outpatient psychiatry only contacted 29.6% that year, although it had the highest average number of visits (15.1 SD22.6). The most frequent diagnostic category among psychiatric patients was F30-39 (26.7%), with differences between sexes and ages. 49.7% received psychotropic drugs. CONCLUSIONS: The results are aligned with international evidence, which they also extend, and reinforce the need to extend prevention beyond psychiatric services. It seems advisable to increase proactivity in the search for risk by sensitizing and training different professional profiles, but also to work from non-health settings to improve assistance to highly vulnerable profiles (young men) with low health links.

2.
Am J Ophthalmol Case Rep ; 35: 102069, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38799226

ABSTRACT

Purpose: This case report highlights a possible association between netarsudil use and crystalline keratopathy. Observations: Presented here is the case of a 72-year-old woman with primary open-angle glaucoma (POAG) who developed corneal crystalline keratopathy after taking netarsudil for 24 months. The patient's medical history was significant for dry eye syndrome, bilateral ptosis with surgical repair, and atopy (including asthma and various ocular and systemic allergies). The patient had previously undergone surgical repair for bilateral ptosis as well. During the interval between two routine visits, this patient experienced worsening vision with associated eye irritation. Further examination revealed crystal deposits on the anterior corneal surface in the left eye, the only eye undergoing netarsudil treatment. Conclusions and importance: Long-term netarsudil use may be associated with crystalline keratopathy in the anterior stroma, with the potential to cause sight-threatening vision loss if located in the visual axis.

3.
Gynecol Oncol ; 187: 145-150, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38776632

ABSTRACT

OBJECTIVES: Sentinel lymph node (SLN) detection with superparamagnetic iron oxide (SPIO) nanoparticles has been widely studied and standardized for breast and prostate cancer, but there is scarce evidence concerning its use in vulvar cancer. The objective of this study was to compare SLN detection using a SPIO tracer injected at the time of the surgery detected by a magnetometer, with the standard procedure of using a technetium 99 radioisotope (Tc99) detected by a gamma probe, in patients with vulvar cancer. METHODS: The SPIO vulvar cancer study was a single-center prospective interventional non-inferiority study of SPIO compared to Tc99, conducted between 2016 and 2021 in patients who met the GROINSS-V study inclusion criteria for selective sentinel lymph node dissection in vulvar cancer. RESULTS: We included 18 patients and a total of 41 SLNs. The level of agreement between tracers was 92.7% (80.6%-97.4%), corresponding to 38 out of 41 SLNs, which confirms the non-inferiority of SPIO compared to Tc99. The SLN detection rate per groin was 96.3 (81.7%-99.3) using Tc99 and 100% (87.5%-100%) using SPIO. Both tracers had a detection rate of 100% for positive lymph nodes. CONCLUSIONS: The use of SPIO as a tracer for detecting SLNs in patients with vulvar cancer has shown to be non-inferior to that of the standard radiotracer, with the advantages of not requiring nuclear medicine and being able to inject it at the time of surgery after induction of anesthesia.

4.
Ophthalmol Glaucoma ; 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38636705

ABSTRACT

PURPOSE: Compare outcomes of tube shunt surgery (Tube) and trabeculectomy with mitomycin C (Trab-MMC) in patients with angle-closure glaucoma (ACG). DESIGN: Retrospective nonrandomized comparative study. PARTICIPANTS: A total of 80 eyes from 80 patients with ACG who underwent either Tube (N = 50) or Trab-MMC (N = 30) between January 2015 and January 2022 at Massachusetts Eye and Ear. METHODS: Reviewed and analyzed 390 visits from patient charts. MAIN OUTCOME MEASURES: Kaplan-Meier (KM) success rates, intraocular pressure (IOP), medication burden, best-corrected visual acuity (BCVA), adjusted hazard ratios (HRs), and complications. RESULTS: Baseline demographics were similar between both groups, except for a higher proportion of patients with pseudophakia and prior incisional ocular surgery in the Tube group. The Trab-MMC procedure had significantly higher KM complete success (CS) rates than the Tube procedure, but similar qualified success (QS) rates. Under QS, the cumulative probability of survival was 87% in the Tube group and 83% in the Trab-MMC group at year 1 (P = 0.77), and 75% in the Tube group and 58% in the Trab-MMC group at year 2 (P = 0.14). Under CS, the cumulative probability of survival was 13% in the Tube group and 59% in the Trab-MMC group at year 1 (P < 0.001), and 11% in the Tube group and 41% in the Trab-MMC group at year 2 (P < 0.001). Both Tube and Trab-MMC procedures resulted in significant patterns of IOP and medication reduction from baseline up to 2 years with mean IOP reduced to 12.6 ± 5.9 mmHg on 2.8 ± 1.4 medications after Tube and 12.1 ± 6.6 mmHg on 2.4 ± 1.7 medications after Trab-MMC. Patients who underwent Trab-MMC required less IOP-lowering medications at every follow-up visit up to year 1, but a similar number at year 2. No significant differences were found in IOP reduction, BCVA, or complication rates between groups. CONCLUSIONS: We demonstrate that Trab-MMC confers similar IOP reduction and QS rates to Tube placement in patients with ACG. Trab-MMC, however, demonstrated greater medication burden reduction up to 1 year, and more favorable CS rates up to 2 years, while still maintaining similar complication rates to Tube. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

5.
Nature ; 626(8001): 1025-1033, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38418912

ABSTRACT

Reaction conditions that are generally applicable to a wide variety of substrates are highly desired, especially in the pharmaceutical and chemical industries1-6. Although many approaches are available to evaluate the general applicability of developed conditions, a universal approach to efficiently discover these conditions during optimizations is rare. Here we report the design, implementation and application of reinforcement learning bandit optimization models7-10 to identify generally applicable conditions by efficient condition sampling and evaluation of experimental feedback. Performance benchmarking on existing datasets statistically showed high accuracies for identifying general conditions, with up to 31% improvement over baselines that mimic state-of-the-art optimization approaches. A palladium-catalysed imidazole C-H arylation reaction, an aniline amide coupling reaction and a phenol alkylation reaction were investigated experimentally to evaluate use cases and functionalities of the bandit optimization model in practice. In all three cases, the reaction conditions that were most generally applicable yet not well studied for the respective reaction were identified after surveying less than 15% of the expert-designed reaction space.

6.
Ophthalmol Glaucoma ; 7(1): 66-74, 2024.
Article in English | MEDLINE | ID: mdl-37536395

ABSTRACT

PURPOSE: Compare outcomes of a gelatin stent (XEN45 Gel Stent [XGS]) placed either ab externo with open conjunctiva (AEO) or ab externo with closed conjunctiva (AEC) with or without cataract surgery in patients with glaucoma. DESIGN: Retrospective nonrandomized comparative study. PARTICIPANTS: A total of 86 eyes from 86 glaucoma patients who received XGS placed either AEO (N = 49) or AEC (N = 37) with or without cataract surgery between May 2019 and April 2022 at Massachusetts Eye and Ear. METHODS: Reviewed and analyzed 809 visits from patient charts from a level 3 triage center. MAIN OUTCOME MEASURES: Intraocular pressure (IOP), medication burden, Kaplan-Meier (KM) success rates, 5-fluorouracil (5-FU) impact, and complications. RESULTS: Baseline demographics were similar between both groups, except for baseline IOP and glaucoma type. Both AEO and AEC procedures resulted in significant patterns of IOP and medication reduction from baseline up to 1 year. The AEO procedure had significantly higher KM qualified success (QS) rates than the AEC procedure, but similar complete success (CS) rates. Under QS, the cumulative probability of survival was 73% in the AEO group and 51% in the AEC group at month 6 and 62% in the AEO group and 20% in the AEC group at year 1. Under CS, the cumulative probability of survival was 41% in the AEO group and 37% in the AEC group at month 6 and 29% in the AEO group and 14% in the AEC group at year 1. The AEO procedure had significantly more IOP reduction than the AEC procedure at all postoperative time points beyond week 2, but similar medication burden reduction. At postoperative year 1 (POY1), the mean IOP was reduced to 10.72 ± 5.71 mmHg on 1.16 ± 1.68 medications after AEO and 17.03 ± 2.37 mmHg on 1.59 ± 1.21 medications after AEC. Phacoemulsification (phaco) was not a significant factor while 5-FU usage trended toward significance. Procedure time was longer for standalone XGS AEO. CONCLUSIONS: We demonstrate that both placements reduce medication and IOP from baseline, with AEO placement having more favorable XGS success rates and IOP control at the expense of longer procedure time and greater 5-FU usage. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Subject(s)
Cataract , Glaucoma , Humans , Gelatin , Retrospective Studies , Glaucoma/surgery , Glaucoma/complications , Fluorouracil , Cataract/complications , Conjunctiva/surgery , Stents
7.
Ophthalmology ; 131(2): 240-248, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38069944

ABSTRACT

PURPOSE: To evaluate the current published literature on the utility of the 10-2 visual field (VF) testing strategy for the evaluation and management of early glaucoma, defined here as mean deviation (MD) better than -6 decibels (dB). METHODS: A search of the peer-reviewed literature was last conducted in June 2023 in the PubMed database. Abstracts of 986 articles were examined to exclude reviews and non-English-language articles. After inclusion and exclusion criteria were applied, 26 articles were selected, and the panel methodologist rated them for strength of evidence. Thirteen articles were rated level I, and 8 articles were rated level II. The 5 level III articles were excluded. Data from the 21 included articles were abstracted and reviewed. RESULTS: The central 12 locations on the 24-2 VF test grid lie within the central 10 degrees covered by the 10-2 VF test. In early glaucoma, defects detected within the central 10 degrees generally agree between the 2 tests. Defects within the central 10 degrees of the 24-2 VF test can predict defects on the 10-2 VF test, although the 24-2 may miss defects detected on the 10-2 VF test. In addition, results from the 10-2 VF test show better association with findings from OCT scans of the macular ganglion cell complex. Modifications of the 24-2 test that include extra test locations within the central 10 degrees improve detection of central defects found on 10-2 VF testing. CONCLUSIONS: Evidence to date does not support routine testing using 10-2 VF for patients with early glaucoma. However, early 10-2 VF testing may provide sufficient additional information for some patients, particularly those with a repeatable defect within the central 12 locations of the standard 24-2 VF test or who have inner retinal layer thinning on OCT scans of the macula. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Subject(s)
Glaucoma , Ophthalmology , Humans , United States , Visual Fields , Scotoma/diagnosis , Retinal Ganglion Cells , Tomography, Optical Coherence/methods , Visual Field Tests , Glaucoma/diagnosis , Glaucoma/complications , Intraocular Pressure
8.
J Glaucoma ; 33(2): 116-125, 2024 02 01.
Article in English | MEDLINE | ID: mdl-37853674

ABSTRACT

PRCIS: Ab externo with open conjunctiva placement may lead to improved gelatin stent (XEN Gel Stent; Allergan) success rate compared with ab interno with closed conjunctiva because it conferred more favorable intraocular pressure (IOP) and medication burden reduction based on our complete and qualified success criteria. PURPOSE: To compare outcomes of a gelatin stent (XEN 45 Gel Stent; Allergan) placed either ab interno with closed conjunctiva (AIC) or ab externo with open conjunctiva (AEO) with or without cataract surgery in patients with glaucoma. DESIGN: Retrospective, nonrandomized comparative study of 85 eyes from 85 glaucoma patients who received XEN 45 Gel Stent placed either AIC (N=32) or AEO (N=53) with or without cataract surgery between July 2018 and January 2022 at Massachusetts Eye and Ear. Patients were included if they were 18 years of age or above and had at least 30 days of follow-up without any disqualifying event. RESULTS: Baseline demographics were similar between both groups, except for the glaucoma type. Both AIC and AEO procedures resulted in significant patterns of IOP and medication reduction from baseline up to 1 year. At postoperative year (POY)1, mean IOP was reduced to 11.34±4 mmHg on 1.29±1.34 medications after AEO and 13.70±3.32 mmHg on 2±1.81 medications after AIC. The average IOP reduction was significantly greater in the AEO group at all postoperative time points beyond postoperative week 2. There were significant differences in the survival curves of AEO and AIC groups under both the complete success criteria and the qualified success criteria. Under the complete success criteria, the cumulative probability of survival at POY1 was 28.5% in the AEO group and 3.8% in the AIC group. Under the qualified success criteria, the cumulative probability of survival at POY1 was 60.3% in the AEO group and 21.9% in the AIC group. CONCLUSIONS: In our study, we demonstrate that both placements reduce IOP and medication from baseline, with AEO placement having more favorable success rates compared with AIC placement.


Subject(s)
Cataract , Glaucoma Drainage Implants , Glaucoma, Open-Angle , Glaucoma , Humans , Infant , Intraocular Pressure , Glaucoma, Open-Angle/surgery , Gelatin , Retrospective Studies , Treatment Outcome , Glaucoma/surgery , Conjunctiva , Stents
9.
Ophthalmol Glaucoma ; 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38056708

ABSTRACT

PURPOSE: To compare trabeculectomy with mitomycin C (trab-MMC) and XEN45 Gel Stent placed ab externo with open conjunctiva (XGS AEO) with or without cataract surgery in patients with glaucoma. DESIGN: Nonrandomized, retrospective, comparative study. SUBJECTS: A total of 204 eyes from 204 glaucoma patients who received XGS AEO or underwent trab-MMC with or without cataract surgery between July 2018 and August 2021 at Massachusetts Eye and Ear. METHODS: Visits from 204 patient charts were reviewed after either trab-MMC or XGS AEO from 2018 to 2021 from a level 3 triage center. MAIN OUTCOME MEASURES: Intraocular pressure (IOP), medication burden, Kaplan-Meier success rates, 5-fluorouracil impact, and complications. RESULTS: One hundred fifty-seven patients underwent trab-MMC and 47 underwent XGS AEO. Groups had similar baseline intraocular pressure (IOP) and medications (meds). Intraocular pressure and meds decreased similarly at 1.5 years (11.2 mmHg vs. 7.4 mmHg, P = 0.62; 2.9 vs. 2.8 meds, P = 0.92, respectively for trab-MMC and XGS AEO). Success was defined as IOP reduction ≥ 20% with 5 mmHg ≤ IOP ≤ 18 mmHg for 2 consecutive visits. Complete success (CS) did not allow meds; qualified success (QS) allowed for ≤ baseline meds. When IOP fluctuations in the first 60 days were not counted as failures, CS was 43% for trab-MMC, about 8.5% higher than for XGS AEO (P < 0.01). Qualified success was similar between the groups (65%-67%). Procedure time was shorter for XGS AEO than trab-MMC (44 vs. 63 minutes, P < 0.01). CONCLUSIONS: XEN45 Gel Stent AEO may provide similar benefits to trab-MMC, especially for patients who tolerate some meds, with shorter procedure times. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

10.
Clin Ophthalmol ; 17: 2879-2888, 2023.
Article in English | MEDLINE | ID: mdl-37807999

ABSTRACT

Purpose: To compare outcomes of phacoemulsification and endocyclophotocoagulation with either dual blade goniotomy (PEcK) or two trabecular stents (ICE2). Setting: Retrospective, nonrandomized comparative study from a level 3 triage center. Methods: One hundred and seventy charts and a total of 1294 visits were reviewed following either PEcK or ICE2 from 2018 to 2022. One hundred and twenty-eight patients had PEcK and 42 underwent ICE2. Patients with less than 30 days of follow-up were excluded. The mean follow-up time was 505 ± 308 days. Two Kaplan-Meier curves (KM) assessed survival with ≤ baseline medications while maintaining (1) [GIC - Goal IOP Criteria] IOP ≤ goal IOP or (2) [PRC - Percent Reduction Criteria] IOP reduction ≥ 20% with 5 mmHg ≤ IOP ≤ 21 mmHg for at least two consecutive visits. IOP and medication burden reduction were compared using a paired t-test. Results: Most patients were Caucasian (65%) and had mild-stage glaucoma (43%). The most common glaucoma type was primary open-angle glaucoma (58%). Average age was 72.2 years at the time of surgery. Mean preoperative IOP was 17.58 ± 4.98 mmHg on 3.00 ± 1.41 medications in PEcK and 15.36 ± 3.58 mmHg on 1.81 ± 1.11 medications in ICE2 (p = 0.015 for IOP; p < 0.001 for medications). Under GIC, the success rate was significantly higher in PEcK at POM6 (69% vs 46%, p < 0.001) and POY1 (63% vs 36%, p < 0.001). Under PRC, the success rate was significantly higher in PEcK at POM6 (73% vs 61%, p = 0.031) and POY1 (67% vs 50%, p = 0.028). Mean reductions at POY1 were 5.00 ± 4.31 mmHg on 1.35 ± 1.08 less medications after PEcK and 3.14 ± 2.83 mmHg on 1.01 ± 0.94 less medications after ICE2 (p < 0.001 at POY1 for IOP; p < 0.05 after POW6 for medications). Conclusion: Both PEcK and ICE2 reduce medication and IOP from baseline, with PEcK having more favorable GIC and PRC success rates and greater IOP and medication reduction at 1 year.

11.
Cureus ; 15(9): e44683, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37809140

ABSTRACT

Predicting the visual outcome after cataract extraction can be challenging in glaucoma patients who develop cataracts. Here, we demonstrate the case of a patient with advanced glaucoma and a mild-to-moderate cataract at initial presentation, who demonstrated remarkable improvement in visual acuity following a period of controlled intraocular pressure (IOP) and the removal of a matured cataract at the time of surgery. A 64-year-old Haitian woman with severe mixed-mechanism glaucoma and hand motion vision in both eyes (OU) presented with intraocular pressures of 38 mmHg OD (oculus dexter/right eye) and 41 mmHg OS (oculus sinister/left eye) while on three IOP-lowering agents. Her medications were escalated to six IOP-lowering medications, and she underwent bilateral transscleral laser cyclophotocoagulation with both micropulse and continuous wave probes simultaneously. Postoperatively, IOPs dropped to 7 and 9 mmHg in the right and left eyes, respectively, and remained at or below target on three topical agents for the remainder of her follow-up. Contrastingly, the patient's cataract had progressed, and the decision was made to undergo cataract extraction OU sequentially. The subsequent clinical course demonstrated progressive visual improvement with 20/80 best-corrected visual acuity OU and increased independence with activities of daily living. This case illustrates the potential for visual improvement in an advanced glaucoma patient after removing a matured cataract despite limited prior expectations. Ocular comorbidities complicate but do not necessarily preclude appropriate interventions that may improve patients' vision-related quality of life.

12.
Clin Ophthalmol ; 17: 2209-2217, 2023.
Article in English | MEDLINE | ID: mdl-37551375

ABSTRACT

Purpose: Neurofilament light chain (NfL) is a neuronal cytoskeletal protein that has been identified as a marker of neurodegeneration in diseases of the central nervous system. In this study, we investigated whether NfL in the aqueous humor (AH) can serve as a marker of neurodegeneration in glaucoma in a racially diverse North American population. Design: Single-center, case-control study. Participants: We enrolled patients with various types and stages of glaucoma undergoing planned ophthalmic surgery as part of their routine care and compared them with patients without glaucoma undergoing phacoemulsification for age-related cataract. Methods: We collected AH from 39 glaucoma patients and 10 patients without glaucoma. AH NfL was quantified using the Single-Molecule Array (Simoa)® NF-light assay (Quanterix). Demographic information, such as age, body mass index, sex, and self-reported race, as well as clinical information, such as pre-operative intraocular pressure (IOP), maximum IOP, and number of pre-operative glaucoma medications, was obtained by reviewing the medical record. Main Outcome Measures: Levels of AH NfL. Results: In a model controlling for age and body mass index (BMI), NfL was significantly elevated in AH from glaucoma patients (mean: 429 pg/mL; standard deviation [SD]: 1136 pg/mL) compared to AH from patients without glaucoma (mean: 3.1 pg/mL; SD: 1.9 pg/mg): P = 0.002. Higher AH NfL was associated with higher maximum IOP (R = 0.44, P = 0.005), higher pre-operative IOP (R = 0.46, P = 0.003), and more pre-operative glaucoma medications (Rs = 0.61, P < 0.001). There was no association between AH NfL and Humphrey visual field mean deviation (R = -0.20, P = 0.220), retinal nerve fiber layer thickness as measured with optical coherence tomography (R = 0.07, P = 0.694), or glaucoma stage (Rs = 0.015, P = 0.935). Conclusion: Our findings suggest that AH NfL may have clinical utility as a marker of glaucomatous neurodegeneration.

13.
Clin Ophthalmol ; 17: 1647-1659, 2023.
Article in English | MEDLINE | ID: mdl-37313217

ABSTRACT

Purpose: Combining two or more MIGS (cMIGS) promises to be more efficacious than single MIGS (sMIGS). This study compared the efficacy of PEcK, which combines Phacoemulsification (Phaco), Endocyclophotocoagulation (ECP), and Kahook dual blade (KDB), relative to both of its constituent sMIGS, Phaco/ECP (Endo Optiks, NJ) and Phaco/KDB (New World Medical, CA) for the first time. Patients and methods: Data was collected retrospectively from 1833 visits of 271 patients who underwent PEcK, Phaco/ECP, or Phaco/KDB from 2016-2021 at Massachusetts Eye and Ear. Primary outcomes included Generalized Estimating Equations (GEE) of intraocular pressure (IOP) and medication burden, as well as survival models. Results: Mean preoperative IOP was 17.6 ± 5.0 (SD) mmHg on 3.0 ± 1.4 medications in the PEcK group (n = 128), 17.9 ± 5.1 mmHg on 2.2 ± 1.5 medications in the Phaco/ECP group (n = 78), and 16.1 ± 4.3 mmHg on 0.4 ± 1.0 medications in the Phaco/KDB group (n = 65). For more than 36 months, all procedures resulted in significant patterns of IOP and medication reduction (all p < 0.001), before and after statistical adjustment. The reduction pattern in IOP was significantly different when comparing all groups over time and favored PEcK (p = 0.04), but the reduction pattern in medications was not significantly different (p = 0.11). Procedures did not differ in procedural time (p = 0.18) or in survival to maintain ≥20% IOP reduction (p = 0.43) without additional medication or procedure. There was a trend toward significant difference in maintaining IOP ≤ goal IOP that favored PEcK over Phaco/ECP after adjustment (p = 0.09). Conclusion: PEcK may confer greater IOP reduction without added procedural time compared to Phaco/ECP and Phaco/KDB in predominantly mild or moderate glaucoma. Further research on cMIGS may benefit from adopting this comparative analysis to constituent MIGS.

14.
Rev. esp. cardiol. (Ed. impr.) ; 76(5): 322-332, mayo 2023. ilus, tab
Article in Spanish | IBECS | ID: ibc-219660

ABSTRACT

Introducción y objetivos La insuficiencia tricuspídea (IT) se asocia con un peor pronóstico si no se corrige. Se han publicado recientemente numerosos estudios sobre reparación transcatéter de la válvula tricúspide (RTT) Métodos Se llevó a cabo una revisión sistemática de estudios que publican datos clínicos de pacientes con IT significativa sometidos a RTT. Se evaluaron objetivos clínicos y ecocardiográficos a corto y medio plazo. Las razones de riesgo (RR) y las diferencias de medias (DM) se obtuvieron de la comparación de datos previos y posteriores a la intervención. Se hizo también un análisis de sensibilidad según el abordaje principal (reparación borde a borde frente a anuloplastia) Resultados Se incluyeron 19 estudios (todos observacionales o ensayos de un solo grupo) con un total de 991 pacientes sometidos a RTT sola. Las tasas de mortalidad e ictus a 30 días fueron del 2,8 y el 0,2% respectivamente. El análisis agrupado de efectos aleatorios mostró una reducción significativa de IT (RR=0,33; IC95%, 0,26-0,42; p <0,001), vena contracta (DM, 5,9mm; IC95%, 4-7,9; p <0,001), diámetro telediastólico del ventrículo derecho (DM, 3,5mm; IC95%, 2,5-4,5; p <0,001) y clase funcional de la NYHA 3 o 4 (RR=0,32; IC95%, 0,27-0,37; p <0,001) a los 30 días. Las complicaciones hemorrágicas y la IT residual al menos grave fueron numéricamente superiores en el grupo de anuloplastia percutánea en comparación con el grupo de reparación borde a borde (hemorragias, el 13,3 y el 2,8%; IT residual, el 40,4 y el 27,9%) Conclusiones En los 991 pacientes que formaron parte de la experiencia inicial de RTT, tras la intervención se observó una reducción estadísticamente significativa del grado de IT grave o peor, una mala clase funcional (NYHA 3-4), la anchura de la vena contracta y el diámetro telediastólico del ventrículo derecho. Hasta ahora, el abordaje con reparación borde a borde parece tener un mejor perfil de seguridad (AU)


Introduction and objectives Severe tricuspid regurgitation (TR) is associated with poor prognosis when left untreated, and a growing number of studies on transcatheter tricuspid valve repair (TTVr) have been published over the last few months. Methods We performed a comprehensive systematic review of published literature providing clinical data on TTVr for patients with significant TR. Early and mid-term clinical and echocardiographic outcomes were evaluated. Risk ratios (RR) or mean differences (MD) were obtained when comparing pre- and postprocedural data. A sensitivity analysis was also performed according to the main approach for repair (edge-to-edge vs annuloplasty). Results A total of 19 studies (all observational or single-arm trials) and 991 patients who underwent isolated TTVr were included. Thirty-day mortality and stroke rates were 2.8% and 0.2%, respectively. Pooled random-effects resulted in a significant reduction of ≥ severe TR (RR, 0.33; 95%CI, 0.26-0.42; P<.001), vena contracta width (MD, 5.9mm; 95%CI, 4-7.9; P <.001), right ventricular end-diastolic diameter (MD, 3.5mm; 95%CI, 2.5-4.5; P <.001), and New York Heart Association (NYHA) class III or IV at last follow-up (RR, 0.32; 95%CI, 0.27-0.37; P <.001). Bleeding complications and residual ≥ severe TR were numerically higher in the annuloplasty-like group compared with edge-to-edge repair (13.3% vs 3.8% for bleeding and 40.4% vs 27.9% for residual severe TR). Conclusions Among 991 patients comprising the early experience for several TTVr devices, there was a statistically significant reduction in ≥ severe TR, NYHA class III-IV, vena contracta width and right ventricular end-diastolic diameter after TTVr. Thus far, the edge-to-edge approach seems to be associated with a better safety profile (AU)


Subject(s)
Humans , Tricuspid Valve Insufficiency/surgery , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation , Observational Studies as Topic , Treatment Outcome , Time Factors
15.
Semin Ophthalmol ; 38(6): 529-536, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36855272

ABSTRACT

The use of microinvasive invasive glaucoma surgery (MIGS) in the treatment of glaucoma has increased exponentially over the last 10 years. However, practice patterns vary widely given the relative newness of these technologies. Some surgeons perform two or more MIGS simultaneously, such as those that target aqueous production and those that target aqueous outflow. These combined MIGS (cMIGS) may result in lower intraocular pressure (IOP) and reduced medication burden as compared to single MIGS (sMIGS). Current evidence suggests some cMIGS are more effective in reducing medication burden for at least 12 months versus sMIGS. This review focuses on the current evidence related to the efficacy of cMIGS as well as novel combinations of standalone MIGS, limitations of the current literature, and future directions for research.


Subject(s)
Glaucoma Drainage Implants , Glaucoma , Humans , Glaucoma/surgery , Ophthalmologic Surgical Procedures , Intraocular Pressure , Tonometry, Ocular
16.
BMC Ophthalmol ; 23(1): 129, 2023 Mar 30.
Article in English | MEDLINE | ID: mdl-36997879

ABSTRACT

PURPOSE: To compare the effectiveness and safety of phacoemulsification combined with endoscopic cyclophotocoagulation (phaco/ECP), phacoemulsification combined with MicroPulse transscleral cyclophotocoagulation (phaco/MP-TSCPC), and phacoemulsification alone (phaco) in the treatment of coexisting cataract and glaucoma. METHODS: Retrospective cohort study of consecutive cases at Massachusetts Eye & Ear. The main outcome measures were the cumulative probabilities of failure between the phaco/ECP group, phaco/MP-TSCPC group, and the phaco alone group with failure defined as reaching NLP vision at any point postoperatively, undergoing additional glaucoma surgery, or the inability to maintain ≥ 20% IOP reduction from baseline with IOP between 5-18 mmHg while maintaining ≤ baseline medications. Additional outcome measures included changes in average IOP, number of glaucoma medications, and complication rates. RESULTS: Sixty-four eyes from 64 patients (25 phaco/ECP, 20 phaco/MPTSCPC, 19 phaco alone) were included in this study. The groups did not differ in age (mean 71.04 ± 6.7 years) or length of follow-up time. Baseline IOPs were significantly different between groups (15.78 ± 4.7 mmHg phaco/ECP, 18.37 ± 4.6 mmHg phaco/MP-TSCPC, 14.30 ± 4.2 mmHg phaco alone, p = 0.02). Primary open-angle glaucoma was the most common type of glaucoma in the phaco alone (42%) and phaco/ECP (48%) groups while mixed-mechanism glaucoma was the most common type in the phaco/MP-TSCPC group (40%). Surgical failure was less likely in eyes in the phaco/MP-TSCPC (3.40 times, p = 0.005) and phaco/ECP (1.40 times, p = 0.044) groups compared to phaco alone based on the Kaplan-Meier survival criteria. These differences maintained statistical significance when differences in preoperative IOP were taken into account using the Cox PH model (p = 0.011 and p = 0.004, respectively). Additionally, surgical failure was 1.98 times less likely following phaco/MP-TSCPC compared to phaco/ECP (p = 0.038). This difference only approached significance once differences in preoperative IOP were accounted for (p = 0.052). There was no significant difference in IOP reduction at 1 year between groups. Mean IOP reductions at 1 year were 3.07 ± 5.3 mmHg from a baseline of 15.78 ± 4.7 in the phaco/ECP group, 6.0 ± 4.3 mmHg from a baseline of 18.37 ± 4.6 in the phaco/MP-TSCPC group and 1.0 ± 1.6 from a baseline of 14.30 ± 4.2 mmHg in the phaco alone group. There were no differences in complication rates among the three groups. CONCLUSIONS: Both Phaco/MP-TSCPC and phaco/ECP appear to provide superior efficacy for IOP control when compared to phaco alone. All three procedures had similar safety profiles.


Subject(s)
Glaucoma, Open-Angle , Glaucoma , Ocular Hypotension , Phacoemulsification , Humans , Middle Aged , Aged , Phacoemulsification/methods , Intraocular Pressure , Glaucoma, Open-Angle/complications , Glaucoma, Open-Angle/surgery , Retrospective Studies , Laser Coagulation/methods , Glaucoma/surgery , Treatment Outcome
17.
Rev Esp Cardiol (Engl Ed) ; 76(5): 322-332, 2023 May.
Article in English, Spanish | MEDLINE | ID: mdl-35662675

ABSTRACT

INTRODUCTION AND OBJECTIVES: Severe tricuspid regurgitation (TR) is associated with poor prognosis when left untreated, and a growing number of studies on transcatheter tricuspid valve repair (TTVr) have been published over the last few months. METHODS: We performed a comprehensive systematic review of published literature providing clinical data on TTVr for patients with significant TR. Early and mid-term clinical and echocardiographic outcomes were evaluated. Risk ratios (RR) or mean differences (MD) were obtained when comparing pre- and postprocedural data. A sensitivity analysis was also performed according to the main approach for repair (edge-to-edge vs annuloplasty). RESULTS: A total of 19 studies (all observational or single-arm trials) and 991 patients who underwent isolated TTVr were included. Thirty-day mortality and stroke rates were 2.8% and 0.2%, respectively. Pooled random-effects resulted in a significant reduction of ≥ severe TR (RR, 0.33; 95%CI, 0.26-0.42; P < .001), vena contracta width (MD, 5.9mm; 95%CI, 4-7.9; P <.001), right ventricular end-diastolic diameter (MD, 3.5mm; 95%CI, 2.5-4.5; P <.001), and New York Heart Association (NYHA) class III or IV at last follow-up (RR, 0.32; 95%CI, 0.27-0.37; P <.001). Bleeding complications and residual ≥ severe TR were numerically higher in the annuloplasty-like group compared with edge-to-edge repair (13.3% vs 3.8% for bleeding and 40.4% vs 27.9% for residual severe TR). CONCLUSIONS: Among 991 patients comprising the early experience for several TTVr devices, there was a statistically significant reduction in ≥ severe TR, NYHA class III-IV, vena contracta width and right ventricular end-diastolic diameter after TTVr. Thus far, the edge-to-edge approach seems to be associated with a better safety profile.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Cardiac Catheterization/methods , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/surgery
18.
Minerva Anestesiol ; 89(7-8): 636-642, 2023.
Article in English | MEDLINE | ID: mdl-36326773

ABSTRACT

BACKGROUND: The best regional anesthesia plan with the best clinical results for Carotid endarterectomy (CEA) has not been defined yet. METHODS: Prospective multicentric observational study of two non-randomized matched cohorts including patients undergoing elective unilateral CEA (N.=100) between January-October 2021. Main outcomes were cerebral oximetry measurements, verbal numeric pain score assessment, peripheral nerve blockades and in-hospital stay. The main objective is to compare results achieved after carotid endarterectomy (CEA) performed under loco-regional blockade (LRB) versus general anesthesia (GA), in terms of intraoperative hemodynamic and neurologic variability. Patients undergoing LRB were performed under ultrasound (US) guidance and mild sedation. RESULTS: The LRB and GA groups showed no differences in comorbidities and risk factors. However, there was a significant difference in the intraoperative hemodynamic behavior due to the amount of vasoactive drugs used (0% vs. 16% for phenylephrine, P=0.006). The results showed neurological stability through the cerebral oximetry measurements during the procedure except for the left hemisphere de-clamp values, which were higher in the GA group (68.7±9.9 vs. 72.7±8.8; P=0.035). There were also significant differences in the verbal pain scale scores assessed 6 hours and 12 hours after the procedure; better pain control was evidenced in the LRB group (0[0-1] vs. 1[0-3], P=0.01; 1[0.5-2] vs. 0[0-2], P=0.01). An increased transient hypoglossal and laryngeal nerves blockade was observed in the LRB group (30% vs. 4%; P<0.001). The in-hospital length of stay was longer in the GA group (77.2±36.3 hours vs. 129.1±41.1 hours; P<0.001). CONCLUSIONS: Although the use of intermediate-deep cervical plexus blockade for CEA confers similar neurologic stability as GA does, there is a difference on the hemodynamic behaviour due to the differences in vasoactive drug consumption. Loco-regional techniques provide a better postoperative pain control and shorten in-hospital length of stay.


Subject(s)
Anesthesia, Conduction , Endarterectomy, Carotid , Humans , Endarterectomy, Carotid/adverse effects , Endarterectomy, Carotid/methods , Cerebrovascular Circulation , Treatment Outcome , Oximetry , Anesthesia, Conduction/methods , Anesthesia, General/adverse effects , Ultrasonography, Interventional/methods , Pain/etiology
19.
Transl Vis Sci Technol ; 11(11): 1, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36318198

ABSTRACT

Purpose: Galectin-3 (Gal-3) and apolipoprotein E (APOE) are markers of activated microglia in neurodegenerative diseases of the central nervous system, whose targeting is protective in mouse models of glaucoma. In this study, we examined levels of Gal-3 and APOE in human aqueous humor (AH) and defined their clinical associations with glaucoma. Methods: We collected AH from 59 glaucoma patients and 15 controls at the start of planned ophthalmic surgery. Gal-3 and APOE levels were quantified by enzyme-linked immunosorbent assay. Total protein in AH was quantified by bicinchoninic acid assay. Significant associations between Gal-3, APOE, and clinical covariates were defined using univariate and multivariate linear regression models. Results: Gal-3 and APOE levels were significantly elevated in the AH of glaucoma patients compared to controls (P = 0.004 and P < 0.001, respectively). Gal-3 and APOE were positively correlated across the entire cohort (r = 0.65, P = 6.2E-9). No association was observed between Gal-3 and total protein or APOE and total protein (P = 0.35 and P = 0.50, respectively), indicating that their levels were not increased in glaucomatous AH due to nonspecific protein accumulation. Multivariate linear regression modeling revealed significant associations between Gal-3 and maximum recorded intraocular pressure (P = 0.009) and between APOE and number of past ophthalmic surgeries (P = 0.031). Conclusions: We demonstrate that Gal-3 and APOE are significantly elevated in the AH of eyes with glaucoma and are associated with a history of poorly controlled disease. Translational Relevance: Gal-3 and APOE in AH may inform clinical decision-making as quantifiable readouts of microglial activation in eyes with glaucoma.


Subject(s)
Glaucoma, Open-Angle , Glaucoma , Animals , Mice , Humans , Aqueous Humor/metabolism , Galectin 3/metabolism , Glaucoma, Open-Angle/metabolism , Biomarkers/metabolism , Apolipoproteins E/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...