Results 1 - 8 de 8
Filter
1.
Arch Peru Cardiol Cir Cardiovasc ; 4(3): 122-126, 2023.
Article in English | MEDLINE | ID: mdl-38046227

ABSTRACT

Complex coronary lesions represent challenging findings for percutaneous coronary intervention and potentially lead to complications during their approach. We present the case of a patient with decompensated heart failure of ischemic origin who presented multiple complex lesions on coronary angiography. The initial approach to the marginal artery was complicated by a severe coronary perforation that was satisfactorily resolved and in the second moment, a bifurcation lesion of the right coronary artery was successfully treated using the inverted Culotte technique.


Las lesiones coronarias complejas representan hallazgos desafiantes para la intervención coronaria percutánea y potencialmente exponen a complicaciones durante su abordaje. Reportamos el caso de un paciente con falla cardíaca descompensada de etiología isquémica que en la angiografía coronaria presentó múltiples lesiones complejas. El abordaje inicial de la arteria marginal se complicó con una perforación coronaria severa que se trató con éxito; en un segundo momento se abordó satisfactoriamente una lesión en bifurcación de la coronaria derecha con técnica de Culotte invertido.

2.
Int J Cardiol ; 351: 25-31, 2022 Mar 15.
Article in English | MEDLINE | ID: mdl-34979152

ABSTRACT

BACKGROUND: Several studies have compared surface electrocardiographic changes following different self-expandable (SE) (Evolut (Medtronic, USA); Acurate (Boston Scientific, USA); Portico (Abbott, USA); and Allegra (NVT, Germany)) and balloon-expandable (BE) Sapien-3 (Edwards Lifesciences, USA) transcatheter heart valves. We aimed to compare these prosthesis with the novel Myval BE prosthesis (Meril Life, India). METHODS: Academic European registry of consecutive patients with severe aortic stenosis who received any of the 6 aforementioned valves. Baseline, post-procedural, and discharge 12­leads electrocardiograms (ECG) were centrally analyzed and compared. RESULTS: A total of 1131 patients were included: 135 Myval (11.9%), 290 Sapien-3 (25.6%), 298 Evolut (26.3%), 180 Acurate (15.9%), 125 Portico (11.1%), and 103 Allegra (9.1%). There were no baseline differences in intraventricular conduction disturbances rate. Compared to the novel BE Myval, there were similar procedural and in-hospital outcomes. Similar rates of early new permanent pacemaker implant (PPI) were observed amongst Myval (7.4%), Sapien-3 (13.4%), and Acurate (9.1%), but Evolut, Portico, and Allegra presented significantly higher rates (18.5%, p = 0.003; 29.5% p < 0.001 and 22%, p = 0.001, respectively). Central analysis of ECGs, unraveled significant prolongation of the PR segment with Evolut, Portico and Allegra whereas Evolut, Acurate, and Portico showed significant QRS widening compared to Myval. However, at discharge no differences in PR segment duration were observed while, Evolut, and Portico- but not Acurate, Allegra or Sapien-3 - still presented significant widening of QRS segment compared to Myval. CONCLUSIONS: After blinded central ECG analysis, the novel Myval balloon-expandable prosthesis was associated with a low rate of early conduction disturbances.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Treatment Outcome
3.
JACC Cardiovasc Interv ; 15(2): 135-146, 2022 01 24.
Article in English | MEDLINE | ID: mdl-35057983

ABSTRACT

OBJECTIVES: The aims of this study were to determine the rate of noncentered coronary ostia and their risk for coronary overlap (CO) and to develop an improved orientation strategy for transcatheter aortic valve replacement (TAVR) devices taking into account anatomical cues to identify patients at risk for CO regardless of commissural alignment and compute an alternative, CO-free TAVR rotation angle for those patients. BACKGROUND: Commissural alignment during TAVR reduces CO risk. However, eccentricity of coronary ostia from the center of the sinus of Valsalva may result in CO even after perfect alignment of TAVR commissures. METHODS: Baseline computed tomography from TAVR candidates helped identify distance from commissures to the right coronary artery (RCA) and the left coronary artery (LCA). Then, for each case, a virtual valve was simulated with ideal commissural or coronary alignment, and the degree of CO was determined. On the basis of the potential BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) efficacy, 3 groups were defined: no risk for CO (>35° from neocommissure to coronary ostia), moderate risk (20°-35°), and severe risk (≤20°). RESULTS: Computed tomographic studies from 107 patients were included. After excluding 7 patients (poor quality or bicuspid valve), 100 patients were analyzed. The RCA showed greater eccentricity compared with the LCA (18.5° [IQR: 3.3°-12.8°] vs 6.5° [IQR: 3.3°-12.8°]; P < 0.001). The mean intercoronary angle was 140.0° ± 18.7° (95% CI: 136.3°-143.7°). Thirty-two patients had moderate to severe risk for CO (≤35°) despite ideal commissural alignment. Greater coronary eccentricity (cutoff for RCA, 24.5°; cutoff for LCA, 19°) and intercoronary angle >147.5° or <103° were associated with greater risk for moderate to severe CO despite commissural alignment (area under the curve: 0.97; 95% CI: 0.91-0.99). If optimal coronary alignment was simulated, this prevented severe CO in all cases and reduced moderate CO from 27% to 5% (P < 0.001). CONCLUSIONS: One third of patients would have CO during TAVR-in-TAVR despite commissural alignment; a 6-fold decrease in this risk was achieved with optimized coronary alignment. Coronary eccentricity and intercoronary angle were the main predictors.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Humans , Prosthesis Design , Treatment Outcome
4.
Rev Esp Cardiol (Engl Ed) ; 75(3): 203-212, 2022 Mar.
Article in English, Spanish | MEDLINE | ID: mdl-33781722

ABSTRACT

INTRODUCTION AND OBJECTIVES: Final position of the neo-commissures is uncontrolled during transcatheter aortic valve implantation (TAVI), potentially hindering coronary access and future procedures. We aimed to develop a standard method to achieve commissural alignment with the ACURATE neo valve. METHODS: The relationship between native and TAVI neo-commissures was analyzed in 11 severe aortic stenosis patients undergoing TAVI. Based on computed tomography analysis, an in silico model was developed to predict final TAVI commissural posts position. A modified implantation technique, accurate commissural alignment (ACA) and a dedicated delivery system were developed. TAVI implants were tested in 3-dimensional (3D) printed models and in vivo. Commissural misalignment and coronary overlap (CO) were analyzed. RESULTS: The in silico model accurately predicted final position of commissural posts irrespective of the implantation technique performed (correlation coefficient, 0.994; 95%CI, 0.989-0.998; P<.001). TAVI implant with patient-specific rotation was simulated in 3D printed models and in 9 patients. ACA-oriented TAVI implants presented adequate commissural alignment in vivo (mean commissural misalignment of 7.7 ±3.9°). None of the ACA oriented implants showed CO, whereas in silico conventional implants predicted CO in 6 of the 9 cases. CONCLUSIONS: Accurate commissural alignment of the ACURATE neo device is feasible by inserting the delivery system with a patient-specific rotation based on computed tomography analysis. This is a simple and reproducible method for commissural alignment that can be potentially used for all kinds of TAVI devices.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Treatment Outcome
5.
Catheter Cardiovasc Interv ; 99(3): 889-895, 2022 02.
Article in English | MEDLINE | ID: mdl-34390296

ABSTRACT

OBJECTIVES: We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. BACKGROUND: The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. METHODS: Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. RESULTS: Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 ± 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 ± 0.8% and 2.2 ± 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 ± 0.2 vs. 2.1 ± 0.6 cm2 ) and mean aortic valve gradient (43.4 ± 11.1 vs. 9.0 ± 3.7 mmHg) improved significantly (p < 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. CONCLUSIONS: Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Female , Humans , Male , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
6.
J Am Heart Assoc ; 10(18): e020682, 2021 09 21.
Article in English | MEDLINE | ID: mdl-34546114

ABSTRACT

Background No study has evaluated the impact of the additional manipulation demanded by multiple resheathing (MR) in patients undergoing transcatheter aortic valve replacement with repositionable self-expanding valves. Methods and Results This study included a real-world, multicenter registry involving 16 centers from Canada, Germany, Latin America, and Spain. All consecutive patients who underwent transcatheter aortic valve replacement with the Evolut R, Evolut PRO, and Portico valves were included. Patients were divided according to the number of resheathing: no resheathing, single resheathing (SR), and MR. The primary end point was device success. Secondary outcomes included procedural complications, early safety events, and 1-year mortality. In 1026 patients, the proportion who required SR and MR was 23.9% and 9.3%, respectively. MR was predicted by the use of Portico and moderate/severe aortic regurgitation at baseline (both with P<0.01). Patients undergoing MR had less device success (no resheathing=89.9%, SR=89.8%, and MR=80%; P=0.01), driven by more need for a second prosthesis and device embolization. At 30 days, there were no differences in safety events. At 1 year, more deaths occurred with MR (no resheathing=10.5%, SR=8.0%, and MR=18.8%; P=0.014). After adjusting for baseline differences and center experience by annual volume, MR associated with less device success (odds ratio, 0.42; P=0.003) and increased 1-year mortality (hazard ratio, 2.06; P=0.01). When including only the Evolut R/PRO cases (N=837), MR continued to have less device success (P<0.001) and a trend toward increased mortality (P=0.05). Conclusions Repositioning a self-expanding valve is used in a third of patients, being multiple in ≈10%. MR, but not SR, was associated with more device failure and higher 1-year mortality, regardless of the type of valve implanted.


Subject(s)
Transcatheter Aortic Valve Replacement , Catheters , Humans , Incidence , Odds Ratio , Registries , Transcatheter Aortic Valve Replacement/adverse effects
8.
J Am Coll Cardiol ; 76(3): 268-276, 2020 07 21.
Article in English | MEDLINE | ID: mdl-32470515

ABSTRACT

BACKGROUND: Coronavirus disease-2019 (COVID-19) is caused by severe acute respiratory-syndrome coronavirus-2 that interfaces with the renin-angiotensin-aldosterone system (RAAS) through angiotensin-converting enzyme 2. This interaction has been proposed as a potential risk factor in patients treated with RAAS inhibitors. OBJECTIVES: This study analyzed whether RAAS inhibitors modify the risk for COVID-19. METHODS: The RASTAVI (Renin-Angiotensin System Blockade Benefits in Clinical Evolution and Ventricular Remodeling After Transcatheter Aortic Valve Implantation) trial is an ongoing randomized clinical trial randomly allocating subjects to ramipril or control groups after successful transcatheter aortic valve replacement at 14 centers in Spain. A non-pre-specified interim analysis was performed to evaluate ramipril's impact on COVID-19 risk in this vulnerable population. RESULTS: As of April 1, 2020, 102 patients (50 in the ramipril group and 52 in the control group) were included in the trial. Mean age was 82.3 ± 6.1 years, 56.9% of the participants were male. Median time of ramipril treatment was 6 months (interquartile range: 2.9 to 11.4 months). Eleven patients (10.8%) have been diagnosed with COVID-19 (6 in control group and 5 receiving ramipril; hazard ratio: 1.150; 95% confidence interval: 0.351 to 3.768). The risk of COVID-19 was increased in older patients (p = 0.019) and those with atrial fibrillation (p = 0.066), lower hematocrit (p = 0.084), and more comorbidities according to Society of Thoracic Surgeons score (p = 0.065). Admission and oxygen supply was required in 4.9% of patients (2 in the ramipril group and 3 in the control group), and 4 of them died (2 in each randomized group). A higher body mass index was the only factor increasing the mortality rate (p = 0.039). CONCLUSIONS: In a high-risk population of older patients with cardiovascular disease, randomization to ramipril had no impact on the incidence or severity of COVID-19. This analysis supports the maintenance of RAAS inhibitor treatment during the COVID-19 crisis. (Renin-Angiotensin System Blockade Benefits in Clinical Evolution and Ventricular Remodeling After Transcatheter Aortic Valve Implantation [RASTAVI]; NCT03201185).


Subject(s)
Angiotensin-Converting Enzyme Inhibitors/adverse effects , Coronavirus Infections/mortality , Pneumonia, Viral/mortality , Ramipril/adverse effects , Aged , Aged, 80 and over , Betacoronavirus , COVID-19 , Coronavirus Infections/chemically induced , Female , Humans , Male , Pandemics , Pneumonia, Viral/chemically induced , Randomized Controlled Trials as Topic , Risk Factors , SARS-CoV-2 , Spain/epidemiology