Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Agressologie ; 32(4): 246-9, 1991.
Article in French | MEDLINE | ID: mdl-1957966

ABSTRACT

Propanidid and methohexital were compared retrospectively to assess the possible neonatal depression following general anesthesia for caesarean section: both have rapid onset and short duration of action and their transplacental passages are similar. Anesthesia was induced with equivalent doses of the two agents in 90 women (45 in each group). For each anesthetic agent, three subgroups were defined according to the indications, depending on emergency criteria and fetal state. There was no significant statistical difference (Student test) regarding clinical and biochemical criteria except for the fetal arterial pH which was more acidic in the propanidid group. In both groups, Apgar scores, arterial and venous pH were significantly more altered when caesarean section was performed for acute fetal depression.


Subject(s)
Anesthesia, Obstetrical/methods , Cesarean Section , Methohexital/administration & dosage , Propanidid/administration & dosage , Adult , Apgar Score , Blood Pressure/drug effects , Female , Heart Rate/drug effects , Humans , Methohexital/pharmacology , Pregnancy , Propanidid/pharmacology , Retrospective Studies
2.
Agressologie ; 30(9-10): 549-51, 1989.
Article in French | MEDLINE | ID: mdl-2624305

ABSTRACT

When tracheal intubation is conducted with traditional laryngoscope PtcO2 fall during the first minute after intubation; when continuous O2 supplied laryngoscope (Laryng O2) is used PtcO2 rise; the difference is statistically significant (p less than 0.001) either the subjects are in curarisation apnea or in spontaneous ventilation. With traditional laryngoscope, the fall is faster with spontaneous ventilation conditions than during curarisation apnea. Likewise in normal conscient subject the same fall is faster (p less than 0.001) during first minute of posthyperoxic spontaneous quiet ventilation than the first minute of voluntary hypocapnic apnea induced by hyperventilation during the same hyperoxia. Such results have to be taken into account for the indications of tracheal intubation technical means if hypoxic conditions are to be suspected, particularly for infants and subjects with cardio-respiratory failure.


Subject(s)
Blood Gas Monitoring, Transcutaneous , Intubation, Intratracheal , Oxygen/analysis , Partial Pressure , Adult , Humans , Laryngoscopes , Oxygen/administration & dosage , Respiration
SELECTION OF CITATIONS
SEARCH DETAIL