1.
Insects ; 12(7)2021 Jul 13.
Article in English | MEDLINE | ID: mdl-34357296

ABSTRACT

Garments treated with chemical insecticides are commonly used to prevent mosquito bites. Resistance to insecticides, however, is threatening the efficacy of this technology, and people are increasingly concerned about the potential health impacts of wearing insecticide-treated clothing. Here, we report a mathematical model for fabric barriers that resist bites from Aedes aegypti mosquitoes based on textile physical structure and no insecticides. The model was derived from mosquito morphometrics and analysis of mosquito biting behavior. Woven filter fabrics, precision polypropylene plates, and knitted fabrics were used for model validation. Then, based on the model predictions, prototype knitted textiles and garments were developed that prevented mosquito biting, and comfort testing showed the garments to possess superior thermophysiological properties. Our fabrics provided a three-times greater bite resistance than the insecticide-treated cloth. Our predictive model can be used to develop additional textiles in the future for garments that are highly bite resistant to mosquitoes.

2.
Perform Prot Cloth Equip ; 11: 222-236, 2020.
Article in English | MEDLINE | ID: mdl-34766175

ABSTRACT

Manikins have been used for almost 100 years to help understand the properties of clothing materials and garments. Data from sweating manikins also have been used within thermoregulation computer models to estimate the physiological responses of humans. In recent years, the development of the ManikinPC system has incorporated a thermoregulation model into a thermal sweating manikin system to provide a real-time analysis of predicted physiological response. This paper describes an experimental study that demonstrates the utility of this manikin-model system to predict the effects of three composite materials used in firefighter suits on human physiological response. This study addresses this question: Can ManikinPC emulate the physiological response of a controlled wear trial using three different sets of firefighter turnout gear in one environmental condition? The average core temperature, skin temperature, and sweat loss from human subjects are compared with the predicted values generated from the manikin coupled with the model. Results indicate similar trends and ranking of the three suits. The data revealed slightly higher predictive responses from the manikin-model system compared with the collected human data.

3.
Ann Work Expo Health ; 62(2): 232-242, 2018 02 13.
Article in English | MEDLINE | ID: mdl-29293872

ABSTRACT

Armed forces typically have personal protective clothing (PPC) in place to offer protection against chemical, biological, radiological and nuclear (CBRN) agents. The regular soldier is equipped with permeable CBRN-PPC. However, depending on the operational task, these PPCs pose too much thermal strain to the wearer, which results in a higher risk of uncompensable heat stress. This study investigates the possibilities of adjustable CBRN-PPC, consisting of different layers that can be worn separately or in combination with each other. This novel concept aims to achieve optimization between protection and thermal strain during operations. Two CBRN-PPC (protective) layers were obtained from two separate manufacturers: (i) a next-to-skin (NTS) and (ii) a low-burden battle dress uniform (protective BDU). In addition to these layers, a standard (non-CBRN protective) BDU (sBDU) was also made available. The effect of combining clothing layers on the levels of protection were investigated with a Man-In-Simulant Test. Finally, a mechanistic numerical model was employed to give insight into the thermal burden of the evaluated CBRN-PPC concepts. Combining layers results in substantially higher protection that is more than the sum of the individual layers. Reducing the airflow on the protective layer closest to the skin seems to play an important role in this, since combining the NTS with the sBDU also resulted in substantially higher protection. As expected, the thermal strain posed by the different clothing layer combinations decreases as the level of protection decreases. This study has shown that the concept of adjustable protection and thermal strain through multiple layers of CBRN-PPC works. Adjustable CBRN-PPC allows for optimization of the CBRN-PPC in relation to the threat level, thermal environment, and tasks at hand in an operational setting.


Subject(s)
Heat Stress Disorders/prevention & control , Military Personnel , Occupational Exposure/prevention & control , Protective Clothing , Adult , Analysis of Variance , Equipment Design , Humans , Male , Materials Testing/methods , Protective Clothing/adverse effects , Protective Clothing/standards , Young Adult
4.
Ind Health ; 55(6): 529-536, 2017 Dec 07.
Article in English | MEDLINE | ID: mdl-28978903

ABSTRACT

To determine safe working conditions in emergency situations at petro-chemical plants in the Netherlands a study was performed on three protective clothing combinations (operator's, firefighter's and aluminized). The clothing was evaluated at four different heat radiation levels (3.0, 4.6, 6.3 and 10.0 k∙W∙m-2) in standing and walking posture with a thermal manikin RadMan™. Time till pain threshold (43°C) is set as a cut-off criterion for regular activities. Operator's clothing did not fulfil requirements to serve as protective clothing for necessary activities at heat radiation levels above 1.5 k∙W∙m-2 as was stated earlier by Den Hartog and Heus1). With firefighter's clothing it was possible to work almost three min up to 4.6 k∙W∙m-2. At higher heat radiation levels firefighter's clothing gave insufficient protection and aluminized clothing should be used. Maximum working times in aluminized clothing at 6.3 k∙W∙m-2 was about five min. At levels of 10.0 k∙W∙m-2 (emergency conditions) emergency responders should move immediately to lower heat radiation levels.


Subject(s)
Hot Temperature , Protective Clothing , Firefighters , Fires , Humans , Manikins , Netherlands , Occupational Exposure/prevention & control , Posture , Skin Temperature/radiation effects
5.
Ann Work Expo Health ; 61(2): 248-259, 2017 03 01.
Article in English | MEDLINE | ID: mdl-28395350

ABSTRACT

A major concern for responders to hazardous materials (HazMat) incidents is the heat strain that is caused by fully encapsulated impermeable (NFPA 1991) suits. In a research project, funded by the US Department of Defense, the thermal strain experienced when wearing these suits was studied. Forty human subjects between the ages of 25 and 50 participated in a protocol approved by the local ethical committee. Six different fully encapsulated impermeable HazMat suits were evaluated in three climates: moderate (24°C, 50% RH, 20°C WBGT), warm-wet (32°C, 60% RH, 30°C WBGT), and hot-dry (45°C, 20% RH, 37°C WBGT, 200 W m-2 radiant load) and at three walking speeds: 2.5, 4, and 5.5 km h-1. The medium speed, 4 km h-1, was tested in all three climates and the other two walking speeds were only tested in the moderate climate. Prior to the test a submaximal exercise test in normal clothing was performed to determine a relationship between heart rate and oxygen consumption (pretest). In total, 163 exposures were measured. Tolerance time ranged from as low as 20 min in the hot-dry condition to 60 min (the maximum) in the moderate climate, especially common at the lowest walking speed. Between the six difference suits limited differences were found, a two-layered aluminized suit exhibited significant shorter tolerance times in the moderate climate, but no other major significant differences were found for the other climates or workloads. An important characteristic of the overall dataset is the large variability between the subjects. Although the average responses seem suitable to be predicted, the variability in the warmer strain conditions ranged from 20 min up to 60 min. The work load in these encapsulated impermeable suits was also significantly higher than working in normal clothing and higher than predicted by the Pandolf equation. Heart rate showed a very strong correlation to body core temperature and was in many cases the limiting factor. Setting the heart rate maximum at 80% of predicted individual maximum (age based) would have prevented 95% of the cases with excessive heat strain. Monitoring of heart rate under operational conditions would further allow individually optimize working times and help in preventing exertional heat stroke.


Subject(s)
Climate , Hot Temperature/adverse effects , Physical Exertion/physiology , Protective Clothing/adverse effects , Workload , Body Temperature/physiology , Exercise Test , Heart Rate/physiology , Humans , Oxygen Consumption
6.
J Occup Environ Hyg ; 14(6): 448-455, 2017 06.
Article in English | MEDLINE | ID: mdl-28278064

ABSTRACT

A major concern for responders to hazardous materials (HazMat) incidents is the heat strain that is caused by fully encapsulated impermeable chemical protective suits. In a research project, funded by the US Department of Defense, the thermal strain experienced when wearing these suits was studied. One particular area of interest was the fluid loss of responders during work in these suits as dehydration may be an additional health concern to the heat strain. 17 City of Raleigh firemen and 24 students were tested at two different labs. Subjects between the ages of 25 and 51 were used for human subject trials in a protocol approved by the local ethical committee. Six different Level A HazMat suits were evaluated in three climates: moderate (24°C, 50% RH, 20°C WBGT), warm-wet (32°C, 60% RH, 30°C WBGT), and hot-dry (45°C, 20% RH, 37°C WBGT, 200 W/m2 radiant load) and at three walking speeds: 2.5 km/hr, 4 km/hr, and 5.5 km/hr. 4 km/hr was tested in all three climates and the other two walking speeds were tested in the moderate climate. Weight loss data was collected to determine fluid loss during these experiments. Working time ranged from as low as 20 min in the hot-dry condition to 60 min (the maximum) in the moderate climate, especially common at the lowest walking speed. The overall results from all experiments showed that fluid loss ranged from 0.2-2.2 L during these exposures, with the average fluid loss being 0.8 L, with 56% of the data between 0.5 L and 1 L of fluid loss. Further analysis showed that a suggestion of drinking 0.7 Liter per hour would safely hydrate over 50% of responders after one work-rest cycle. Applying this fluid volume over three work-rest cycles only put 11% of responders at risk of hypohydration vs. the 57% at risk with no fluid intake.


Subject(s)
Dehydration/prevention & control , Protective Clothing/adverse effects , Adult , Dehydration/physiopathology , Firefighters , Hot Temperature , Humans , Male , Middle Aged , Physical Exertion , Walking Speed/physiology , Water Loss, Insensible , Weight Loss