Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Biosens Bioelectron ; 258: 116357, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38729049

ABSTRACT

The label probe plays a crucial role in enhancing the sensitivity of lateral flow immunoassays. However, conventional fluorescent microspheres (FMs) have limitations due to their short fluorescence lifetime, susceptibility to background fluorescence interference, and inability to facilitate multi-component detection. In this study, carboxylate-modified Eu(III)-chelate-doped polystyrene nanobeads were employed as label probes to construct a multiple time-resolved fluorescent microsphere-based immunochromatographic test strip (TRFM-ICTS). This novel TRFM-ICTS facilitated rapid on-site quantitative detection of three mycotoxins in grains: Aflatoxin B1 (AFB1), Zearalenone (ZEN), and Deoxynivalenol (DON). The limit of detection (LOD) for AFB1, ZEN, and DON were found to be 0.03 ng/g, 0.11 ng/g, and 0.81 ng/g, respectively. Furthermore, the TRFM-ICTS demonstrated a wide detection range for AFB1 (0.05-8.1 ng/g), ZEN (0.125-25 ng/g), and DON (1.0-234 ng/g), while maintaining excellent selectivity. Notably, the test strip exhibited remarkable stability, retaining its detection capability even after storage at 4 °C for over one year. Importantly, the detection of these mycotoxins relied solely on simple manual operations, and with a portable reader, on-site detection could be accomplished within 20 min. This TRFM-ICTS presents a promising solution for sensitive on-site mycotoxin detection, suitable for practical application in various settings due to its sensitivity, accuracy, simplicity, and portability.


Subject(s)
Biosensing Techniques , Edible Grain , Food Contamination , Limit of Detection , Microspheres , Mycotoxins , Zearalenone , Mycotoxins/analysis , Edible Grain/chemistry , Edible Grain/microbiology , Biosensing Techniques/methods , Food Contamination/analysis , Zearalenone/analysis , Chromatography, Affinity/methods , Chromatography, Affinity/instrumentation , Aflatoxin B1/analysis , Aflatoxin B1/isolation & purification , Trichothecenes/analysis , Reagent Strips/analysis , Immunoassay/methods , Immunoassay/instrumentation , Fluorescent Dyes/chemistry
2.
J Pharm Biomed Anal ; 219: 114946, 2022 Sep 20.
Article in English | MEDLINE | ID: mdl-35882177

ABSTRACT

Florfenicol (FF), used popularly in prevention and treatment of virus infections in livestock and poultry, has widely been found in eggs and harmful to human health. In this work, a sensitive and quantitative on-site detecting solution, monoclonal antibody-based carboxylated fluorescent microsphere immunochromatographic test strip assay (FM-ICTS), is design and applied for FF detection. The proposed method can sensitively detect FF in low detection limit of 0.030 ng/g and quantitatively measure its concentration from 0.1 ng/mL to 8.1 ng/mL (R2 = 0.9991) with high repeatability (CV<8.0 %). In addition, the established FM-ICTS method exhibited high measurement accuracy in FF samples as compared with HPLC-MS analysis and demonstrated satisfied recoveries (99.1-101.3 %). More importantly, the quantitative FF test strip demonstrate ultra-high stability, which presents approximately equivalent detection ability to the fresh one after stored at 4 °C for more than one year or stored at 37 °C for 60 days. Therefore, the proposed method is a promising solution for rapidly and sensitively quantitative determination of FF in eggs.


Subject(s)
Thiamphenicol , Chromatography, Affinity/methods , Eggs/analysis , Humans , Immunoassay/methods , Limit of Detection , Microspheres , Thiamphenicol/analogs & derivatives , Thiamphenicol/analysis
SELECTION OF CITATIONS
SEARCH DETAIL