A novel, simple, specific, rapid, enantioselective normal phase chiral high-performance liquid chromatographic method with amylose-based Chiral Pak IG-3(250 × 4.6 mM) 3.0 µM column was developed and validated for separation and quantification of isomers and enantiomer of Valbenazine. The mobile phase composed of n-Heptane, isopropyl alcohol, dichloromethane, ethanol, and diethylamine in the ratio of 70:10:15:5:0.1 (V/V/V/VV) with a gradient flow rate was applied. The injection volume was 10 µl, and detection was carried out using a photodiode array detector at 282 nM. The column compartment was set at 35°C. The resolution between the enantiomer and isomers was found to be more than 2.0. The method was linear over the concentration range of limit of quantitation to 250% for isomers and enantiomers. The method was found to be robust with column temperature. The proposed chiral method is applicable for the determination of isomers and enantiomer of Valibenazine and was successfully used in the quality control of bulk drug manufacturing and pharmaceuticals.