Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Methods Mol Biol ; 681: 449-58, 2011.
Article in English | MEDLINE | ID: mdl-20978982

ABSTRACT

Shotgun proteomics is a rapid and near universal strategy to identify proteins in complex protein mixtures. After protein digestion, the resulting peptide mixture is submitted to two orthogonal techniques: peptides are first separated according to their isoelectric point (pI) by isoelectric focusing (IEF) on immobilized pH gradient (IPG); after peptide extraction, they are then separated in the second dimension according to their hydrophobic properties by reverse phase liquid chromatography (RPLC). Finally, they are detected by tandem mass spectrometry (MS/MS) and proteins are matched by means of bioinformatics software.


Subject(s)
Chromatography, Liquid/methods , Isoelectric Focusing/methods , Proteomics/methods , Tandem Mass Spectrometry/methods , Analytic Sample Preparation Methods , Chromatography, Reverse-Phase , Databases, Protein , Hydrogen-Ion Concentration , Models, Molecular , Peptide Fragments/analysis , Peptide Fragments/isolation & purification , Peptide Fragments/metabolism , Protein Conformation , Proteins/analysis , Proteins/chemistry , Proteins/isolation & purification , Proteins/metabolism
2.
J Microbiol Methods ; 80(1): 56-62, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19913576

ABSTRACT

In bottom-up proteomics, rapid and efficient protein digestion is crucial for data reliability. However, sample preparation remains one of the rate-limiting steps in proteomics workflows. In this study, we compared the conventional trypsin digestion procedure with two accelerated digestion protocols based on shorter reaction times and microwave-assisted digestion for the preparation of membrane-enriched protein fractions of the human pathogenic bacterium Staphylococcus aureus. Produced peptides were analyzed by Shotgun IPG-IEF, a methodology relying on separation of peptides by IPG-IEF before the conventional LC-MS/MS steps of shotgun proteomics. Data obtained on two LC-MS/MS platforms showed that accelerated digestion protocols, especially the one relying on microwave irradiation, enhanced the cleavage specificity of trypsin and thus improved the digestion efficiency especially for hydrophobic and membrane proteins. The combination of high-throughput proteomics with accelerated and efficient sample preparation should enhance the practicability of proteomics by reducing the time from sample collection to obtaining the results.


Subject(s)
High-Throughput Screening Assays/methods , Proteome/chemistry , Proteomics/methods , Staphylococcus aureus/chemistry , Bacterial Proteins/chemistry , Hydrolysis , Microwaves , Trypsin/chemistry
3.
Proteomics ; 3(8): 1418-24, 2003 Aug.
Article in English | MEDLINE | ID: mdl-12923766

ABSTRACT

Hydrophobic proteins are difficult to analyze by two-dimensional electrophoresis (2-DE) because of their intrinsic tendency to self-aggregate during the first dimension (isoelectric focusing, IEF) or the equilibration steps. This aggregation renders their redissolution for the second dimension uncertain and results in the reduction of the number and intensity of protein spots, and in undesirable vertical and horizontal streaks across gels. Trifluoroethanol (TFE) is traditionally used at high concentration to solubilize peptides and proteins for NMR studies. Depending upon its concentration, TFE strongly affects the three-dimensional structure of proteins. We report here a phase separation system based on TFE/CHCl(3), which is able to extract a number of intrinsic membrane proteins. The addition of TFE in the in-gel sample rehydration buffer to improve membrane protein IEF separation is also presented. The procedure using urea, thiourea, and sulfobetaine as chaotropic agents was modified by the addition of TFE and removing of sulfobetaine at an optimized concentration in the solubilization medium used for the first dimension. When using membrane fractions isolated from Escherichia coli, the intensity and the number of spots detected from 2-DE gels that used TFE in the solubilization medium were significantly increased. The majority of the proteins identified using peptide mass fingerprinting and tandem mass spectrometry (MS/MS) were intrinsic membrane proteins, proteins of beta barrel structure or transmembrane proteins.


Subject(s)
Membrane Proteins/isolation & purification , Trifluoroethanol/chemistry , Electrophoresis, Gel, Two-Dimensional , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
SELECTION OF CITATIONS
SEARCH DETAIL