1.
J Cardiovasc Electrophysiol ; 35(5): 942-949, 2024 May.
Article in English | MEDLINE | ID: mdl-38462681

ABSTRACT

INTRODUCTION: Mapping system is useful in ablation of atrioventricular nodal reentry tachycardia (AVNRT) and localization of anatomic variances. Voltage mapping identifies a low voltage area in the Koch triangle called low-voltage-bridge (LVB); propagation mapping identifies the collision point (CP) of atrial wavefront convergence. We conducted a prospective study to evaluate the relationship between LVB and CP with successful site of ablation and identify standard value for LVB. MATERIALS AND METHODS: Three-dimensional (3D) maps of the right atria were constructed from intracardiac recordings using the ablation catheter. Cut-off values on voltage map were adjusted until LVB was observed. On propagation map, atrial wavefronts during sinus rhythm collide in the site representing CP, indicating the area of slow pathway conduction. Ablation site was selected targeting LVB and CP site, confirmed by anatomic position on fluoroscopy and atrioventricular ratio. RESULTS: Twenty-seven consecutive patients were included. LVB and CP were present in all patients. Postprocedural evaluation identified standard cut-off of 0.3-1 mV useful for LVB identification. An overlap between LVB and CP was observed in 23 (85%) patients. Procedure success was achieved in all patient with effective site at first application in 22 (81%) patients. There was a significant correlation between LVB, CP, and the site of effective ablation (p = .001). CONCLUSION: We found correlation between LVB and CP with the site of effective ablation, identifying a voltage range useful for standardized LVB identification. These techniques could be useful to identify ablation site and minimize radiation exposure.


Subject(s)
Action Potentials , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Heart Rate , Tachycardia, Atrioventricular Nodal Reentry , Humans , Tachycardia, Atrioventricular Nodal Reentry/surgery , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Male , Female , Prospective Studies , Middle Aged , Treatment Outcome , Adult , Predictive Value of Tests , Aged , Atrioventricular Node/physiopathology , Atrioventricular Node/surgery , Time Factors
2.
J Electrocardiol ; 81: 123-131, 2023.
Article in English | MEDLINE | ID: mdl-37688842

ABSTRACT

BACKGROUND: In patients with a type 2 or 3 Brugada pattern, the pharmacological (IC drugs) induction of a type 1 pattern confirms the diagnosis of Brugada syndrome. OBJECTIVE: To evaluate the value of various ECG markers in predicting IC drug test results. METHODS: We retrospectively analysed 443 consecutive patients referred to our Center (from January 2010 to December 2019) to undergo Ajmaline/Flecainide testing; all had a type 2 or 3 Brugada pattern or were relatives with Brugada syndrome. Clinical parameters and ECG markers (r1V1 and SV6 duration and amplitude, QRSV1/QRSV6 duration, V1 and V2 ST amplitude) were independently evaluated for their association to pharmacological test positivity, and a logistic regression model was applied. RESULTS: The drug test was positive in 151 (34%) patients. On multivariate logistic regression analysis, age > 45 years, female gender, HR >60 bpm, QRSV1/QRSV6 duration >1 and non-isoelectric pattern in V2 were associated with a positive test. The percentage of patients who tested positive increased according to the presence of the above ECG markers (from 11.3% in the absence to 57.6% in the presence of both factors). During long-term follow-up, the clinical event rate was higher in patients with predictive ECG markers and very low in those without. CONCLUSIONS: In our population we confirmed the ability of QRSV1/QRSV6 duration >1 and of a non-isoelectric pattern in V2 to predict a pharmacologically induced type 1 Brugada pattern. Patients with neither of these ECG markers had a rather low event rate during follow-up.


Subject(s)
Brugada Syndrome , Humans , Female , Middle Aged , Brugada Syndrome/complications , Retrospective Studies , Electrocardiography/methods , Ajmaline/adverse effects , Flecainide
3.
J Arrhythm ; 39(2): 192-197, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37021028

ABSTRACT

Background: The effect of cardiac resynchronization therapy (CRT) on the risk of ventricular arrhythmias is controversial. Several studies reported a decreased risk, but some studies reported a potential proarrhythmic effect of epicardial left ventricular pacing resolved upon discontinuation of biventricular pacing (BiVp). Case Summary: A 67-year-old woman with a history of heart failure due to nonischemic cardiomyopathy and left bundle branch block was hospitalized for CRT device implantation. Unpredictably, as soon as the leads have been connected to the generator, an electrical storm (ES) occurred with relapsing self-resolving polymorphic ventricular tachycardia (PVT) triggered by ventricular extra beats with short-long-short sequences. The ES was resolved without interrupting BiVp switching to unipolar left ventricular (LV) pacing. This allowed to keep CRT active with extreme clinical benefit for the patient and to demonstrate that the cause of the PVT was the anodic capture of bipolar LV stimulation. Reverse electrical remodeling was also demonstrated after 3 months of effective BiVp. Discussion: Proarrhythmic effect of CRT is a rare but significant complication of CRT, and it may compel to discontinuation of the BiVp. The reversal of the physiological transmural activation sequence of epicardial LV pacing and subsequent prolonging of corrected QT interval have been speculated as the most probable explanation, but our case highlights the possibility that the anodic capture may play a relevant role in PVT genesis.

4.
J Interv Card Electrophysiol ; 66(7): 1749-1757, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36869990

ABSTRACT

BACKGROUND: A novel ablation catheter has been released to map and ablate the cavo-tricuspid isthmus (CTI) in patients with atrial flutter (AFL), improving ablation efficiency. METHODS: We evaluated the acute and long-term outcome of CTI ablation aiming at bidirectional conduction block (BDB) in a prospective, multicenter cohort study enrolling 500 patients indicated for typical AFL ablation. Patients were grouped on the basis of the AFL ablation method (linear anatomical approach, Conv group n = 425, or maximum voltage guided, MVG group, n = 75) and ablation catheter (mini-electrodes technology, MiFi group, n = 254, or a standard 8-mm ablation catheter, BLZ group, n = 246). RESULTS: Complete BDB according to both validation criteria (sequential detailed activation mapping or mapping only the ablation site) was achieved in 443 patients (88.6%). The number of RF applications needed to achieve BDB was lower in the MiFi MVG group vs both the MiFi Conv group and the BLZ Conv group (3.2 ± 2 vs 5.2 ± 4 vs 9.3 ± 5, p < 0.0001 for all comparisons). Fluoroscopy time was similar among groups, whereas we observed a reduction in the procedure duration from the BLZ Conv group (61.9 ± 26min) to the MiFi MVG group (50.6 ± 17min, p = 0.048). During a mean follow-up of 548 ± 304 days, 32 (6.2%) patients suffered an AFL recurrence. No differences were found according to BDB achieved by both validation criteria. CONCLUSIONS: Ablation was highly effective in achieving acute CTI BDB and long-term arrhythmia freedom irrespective of the ablation strategy or the validation criteria for CTI chosen by the operator. The use of an ablation catheter equipped with mini-electrodes technology seems to improve ablation efficiency. CLINICAL TRIAL REGISTRATION: Atrial Flutter Ablation in a Real World Population. (LEONARDO). CLINICALTRIALS: gov Identifier: NCT02591875.


Subject(s)
Atrial Flutter , Catheter Ablation , Humans , Atrial Flutter/diagnostic imaging , Atrial Flutter/surgery , Catheter Ablation/methods , Cohort Studies , Multicenter Studies as Topic , Prospective Studies , Treatment Outcome , Clinical Studies as Topic
5.
J Cardiovasc Med (Hagerstown) ; 23(10): 646-654, 2022 10 01.
Article in English | MEDLINE | ID: mdl-36099071

ABSTRACT

BACKGROUND: Atrial fibrillation catheter ablation (AFCA) should be considered as a strategy to avoid pacemaker (PM) implantation for patients with bradycardia-tachycardia syndrome (BTS), but lack of evidence is remarkable. METHODS: Our aim was to conduct a random-effects model meta-analysis on safety and efficacy data from controlled trials and observational studies. We compared atrial fibrillation (AF) recurrence, AF progression, procedural complication, additional procedure, cardiovascular death, cardiovascular hospitalization, heart failure and stroke in patients undergoing AFCA vs. PM implantation. RESULTS: PubMed/MEDLINE, Cochrane Database and Google Scholar were screened, and four retrospective studies were selected. A total of 776 patients (371 in the AFCA group, 405 in the PM group) were included. After a median follow-up of 67.5 months, lower AF recurrence [odds ratio (OR) 0.06, confidence interval (CI) 0.02-0.18, I2 = 82.42%, P < 0.001], AF progression (OR 0.12, CI 0.06-0.26, I2 = 0%, P < 0.001), heart failure (OR 0.12, CI 0.04-0.34, I2 = 0%, P < 0.001), and stroke (OR 0.30, CI 0.15-0.61, I2 = 0%, P = 0.001) were observed in the AFCA group. No differences were observed in cardiovascular death and hospitalization (OR 0.48, CI 0.10-2.28, I2 = 0%, P = 0.358 and OR 0.43, CI 0.14-1.29, I2 = 87.52%, P = 0.134, respectively). Higher need for additional procedures in the AFCA group was highlighted (OR 3.65, CI 1.51-8.84, I2 = 53.75%, P < 0.001). PM implantation was avoided in 91% of BTS patients undergoing AFCA. CONCLUSIONS: AFCA in BTS patients seems to be more effective than PM implantation in reducing AF recurrence and PM implantation may be waived in most BTS patients treated by AFCA. Need for additional procedures in AFCA patients is balanced by long-term benefit in clinical end points.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Stroke , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Bradycardia/diagnosis , Bradycardia/therapy , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Failure/complications , Humans , Observational Studies as Topic , Retrospective Studies , Sick Sinus Syndrome/complications , Stroke/etiology , Tachycardia
6.
Minerva Cardiol Angiol ; 69(1): 15-24, 2021 02.
Article in English | MEDLINE | ID: mdl-32657553

ABSTRACT

BACKGROUND: Cardiac contractility modulation (CCM) is a treatment option for patients suffering symptomatic chronic heart failure (CHF) with reduced left ventricular ejection fraction (LVEF) who are not eligible for cardiac resynchronization. Data on mid-term follow-up are limited to small observational studies. The aim of this study was to assess the impact of CCM on quality of life, symptoms, exercise tolerance and left ventricular function in patients with CHF and moderate-to-severe left ventricular systolic dysfunction. METHODS: Patients suffering CHF with LVEF <45% and NYHA class >II despite optimal medical therapy, underwent CCM implantation. Enrolled patients underwent baseline and 3, 6 and 12-months evaluation with ECG, echocardiogram, clinical assessment, 6-minute walking test and Minnesota Living with Heart Failure Questionnaire (MLWHFQ). RESULTS: Ten patients underwent CCM implantation. All patients were actively treated with the optimal pharmacological therapy as tolerated and had at least one hospitalization for worsening heart failure during the previous year. After a mean follow-up of 15 months, 9 patients were alive, while one patient died for worsening heart failure precipitated by pneumonia. Among the remaining 9 patients, LVEF improved non-significantly from 29.4±8% to 32.2±10% (P=0.092), 6-minute walking test distance improved from 179±73 m to 304±99 m (P<0.001), NYHA class reduced from 3.0±0.4 to 1.6±0.5 (P=0.003) and MLWHFQ score improved from 59.6±49 to 34.2±32 (P=0.037). Only 2 patients have been hospitalized during the 12 months. Overall, a net clinical benefit was detected in 6 out of 9 patients. CONCLUSIONS: CCM could be effective in improving quality of life, symptoms and exercise tolerance, and reduces hospitalizations in patients with symptomatic CHF on top of optimal medical and electrical therapy. A prospective registry has been designed to identify the subsets of patients gaining more benefit, and to assess the long-term effect of CCM on those clinical endpoints.


Subject(s)
Quality of Life , Ventricular Function, Left , Humans , Pilot Projects , Registries , Stroke Volume , Treatment Outcome
7.
Pacing Clin Electrophysiol ; 41(6): 597-602, 2018 06.
Article in English | MEDLINE | ID: mdl-29635696

ABSTRACT

BACKGROUND: Simultaneous cathodic-anodal capture by a bipole of a cardiac resynchronization therapy (CRT) left-ventricular (LV) catheter may depolarize a larger LV area than conventional multipoint pacing. We evaluated the feasibility of cathodic-anodal LV stimulation. METHODS: In 30 patients undergoing CRT with a quadripolar LV lead, we evaluated the cathodic and anodal capture threshold for each LV pole and compared QRS on electrocardiogram (ECG) during single-point cathodic biventricular stimulation (S-BS), multipoint BS (M-BS), and cathodic-anodal BS (CA-BS). RESULTS: Anodal capture was obtained by three poles in 23/30 patients, by two poles in five, and was not feasible in two. The mean single-point anodal threshold was 3.93 V versus single-point cathodic threshold of 1.95 V. On comparing ECGs, M-BS and CA-BS produced similar QRS wavefront activation in 90% of patients. CONCLUSIONS: CA-BS is feasible and may be used in LV pacing to achieve a different wavefront of electrical activation. Further prospective studies are needed in order to verify the clinical impact of this kind of stimulation.


Subject(s)
Bundle-Branch Block/physiopathology , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy Devices , Cardiac Resynchronization Therapy/methods , Heart Failure/physiopathology , Heart Failure/therapy , Heart Ventricles/physiopathology , Aged , Electrocardiography , Feasibility Studies , Female , Humans , Male , Treatment Outcome
8.
Europace ; 20(6): 979-985, 2018 06 01.
Article in English | MEDLINE | ID: mdl-28595339

ABSTRACT

Aims: Electrical storm (ES) is a condition defined as three or more episodes of ventricular fibrillation (VF) or ventricular tachycardia (VT) within 24 h, and usually coexist with advanced heart failure in patients with structural heart disease. The aim of the present study is to test whether cardiac resynchronization therapy (CRT) can be associated with a lower incidence of ES. Methods and results: The OBSERVO-ICD (NCT02735811) is a multicentre, retrospective registry, enrolling all consecutive patients undergoing ICD or CRT-D implantation from 2010 to 2012 in five Italian high-volume arrhythmia centres. Propensity score matching was used to compare two equally sized cohorts of ICD and CRT-D patients with similar characteristics. The primary endpoint was the time free from ES. Secondary endpoints were time free from unclustered VT/VF episodes and time free from ES in CRT-D patients according to clinical or echographic response. CRT-D was associated with a 45% relative risk reduction in ES when compared with ICD (5.6% vs. 12.3%; log rank P = 0.014). CRT-responders presented lower rates of ES when compared with non-responders and negative responders according to both clinical and echographic criteria (log-rank P = 0.017 and 0.023, respectively). No ES was detected in any of the 133 full responders to CRT-D. Clinical and echographic positive responses, but not CRT-implant per se, were associated with lower estimate rates of unclustered VTs/VFs. Conclusion: Patients with CRT had a lower incidence of ES when compared with propensity-matched ICD patients. The long-term benefit of CRT seems to be due to the improved haemodynamics, as CRT-responders performed markedly better over a long-term follow-up.


Subject(s)
Cardiac Resynchronization Therapy , Tachycardia, Ventricular , Ventricular Fibrillation , Aged , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy/statistics & numerical data , Female , Follow-Up Studies , Heart Failure/physiopathology , Heart Failure/therapy , Hemodynamics , Humans , Incidence , Italy/epidemiology , Male , Middle Aged , Registries/statistics & numerical data , Risk Assessment , Risk Factors , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/physiopathology , Time , Treatment Outcome , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/etiology , Ventricular Fibrillation/physiopathology
9.
Heart Rhythm ; 13(10): 1987-92, 2016 10.
Article in English | MEDLINE | ID: mdl-27291511

ABSTRACT

BACKGROUND: Electrical storm (ES) is defined as 3 or more episodes of ventricular fibrillation (VF) or ventricular tachycardia (VT) within 24 hours and is associated with increased cardiac and all-cause mortality. OBJECTIVE: The purpose of this study was to test whether aggressive implantable cardioverter-defibrillator (ICD) programming can be associated with ES. METHODS: The OBSERVational registry On long-term outcome of ICD patients (OBSERVO-ICD) is a multicenter, retrospective registry enrolling all consecutive patients undergoing ICD implantation from 2010 to 2012 in 5 Italian high-volume arrhythmia centers. Clinical history and risk factors were collected for all patients, as were ICD therapy-related variables such as detection zones and delays. The total number of arrhythmic episodes and therapies delivered by the ICD were collected through out-of-hospital visits and remote monitoring. RESULTS: The registry enrolled 1319 consecutive patients, of whom 62 (4.7%) experienced at least 1 ES during follow-up (median 39 months). Patients who experienced ES had a significantly lower VF detection zone (P = .002), more frequently had antitachycardia pacing therapies programmed off during capacitor charge (P = .001), and less frequently had an ICD set with delayed therapies for VT zones (P = .042) and VF zone (P = .036). Patients who experienced ES had a significantly higher incidence of death and heart failure-related death compared to patients with no ventricular arrhythmias and patients with unclustered VTs/VFs (P = .025 and P <.001, respectively). CONCLUSION: Patients with ES had a more aggressive ICD programming setup, including lower VF detection rates, shorter detection times, and no antitachycardia pacing therapies during capacitor charge. This kind of ICD programming potentially could increase the likelihood of ES and the related risk of death.


Subject(s)
Defibrillators, Implantable/adverse effects , Tachycardia, Ventricular , Ventricular Fibrillation , Aged , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/statistics & numerical data , Equipment Failure Analysis/statistics & numerical data , Female , Humans , Incidence , Italy/epidemiology , Male , Middle Aged , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/mortality , Ventricular Fibrillation/therapy