Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Eur J Radiol ; 118: 277-284, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31301872

ABSTRACT

INTRODUCTION: To assess the feasibility and diagnostic value of compressed sensing for accelerating two-dimensional turbo spin echo imaging of the ankle. MATERIALS AND METHODS: Ankles of 20 volunteers were scanned (mean age 30.2 ±â€¯7.3 years, 13 men) at 3 T MRI. Coronal and sagittal intermediate-weighted (IM) sequences with fat saturation as well as axial T2- and coronal T1-weighted sequences were acquired using parallel imaging based on sensitivity encoding (SENSE) only as well as with a combination of compressed sensing (CS) and SENSE. Compressed sensing is a technique that acquires less data through k-space random undersampling and enables a reduction in total acquisition time by 20%. All images were reviewed by two radiologists, image quality was graded using a 5-point Likert scale and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of different anatomical structures of the ankle were assessed and compared between sequences with SENSE only and with the combination of CS and SENSE using Wilcoxon signed-rank tests and Cohen's kappa. RESULTS: There was a substantial to perfect agreement for the rating between the images acquired with SENSE only and with the combination of CS and SENSE when assessing cartilage, subchondral bone and ligaments (κ = 0.75 - 0.89). SNR was slightly higher for the combination of CS and SENSE sequences compared to the sequences acquired with SENSE only, yet this finding was not significant (P = 0.18-0.62). Moreover, CNR of cartilage/fluid, subchondral bone/cartilage, ligaments/fluid and ligaments/fat did not show significant differences between the sequences acquired with SENSE only and the combination of CS and SENSE (P > 0.05). The interreader agreement was substantial to excellent for both techniques (κ=0.75 - 0.89). CONCLUSIONS: Compressed sensing reduced the acquisition time of conventional MR imaging of the ankle by 20% without decreasing diagnostic image quality, SNR and CNR.


Subject(s)
Ankle Joint/anatomy & histology , Adult , Bone and Bones/anatomy & histology , Cartilage/anatomy & histology , Echo-Planar Imaging/methods , Feasibility Studies , Female , Healthy Volunteers , Humans , Ligaments, Articular/anatomy & histology , Male , Observer Variation , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...