Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 99
Filter
8.
Microvasc Res ; 143: 104386, 2022 09.
Article in English | MEDLINE | ID: mdl-35623407

ABSTRACT

Appraisal of microvascular erythrocyte velocity as well as aggregation are critical features of hemorheological assessment. Examination of erythrocyte velocity-aggregate characteristics is critical in assessing disorders associated with coagulopathy. Microvascular erythrocyte velocity can be assessed using various methodologic approaches; however, the shared assessment of erythrocyte velocity and aggregation has not been well described. The purpose of this study therefore is to examine three independent erythrocyte assessment strategies with and without experimentally induced aggregation in order to elucidate appropriate analytic strategy for combined velocity/aggregation assessment applicable to in-vivo capillaroscopy. We employed a hierarchical microfluidic model combined with Bland-Altman analysis to examine agreement between three methodologies to assess erythrocyte velocity appropriate for interpretation of cinematography of in-vivo microvascular hemorheology. We utilized optical and manual techniques as well as a technique which we term transversal temporal cross-correlation (TTC) to observe and measure both erythrocyte velocity and aggregation. In general, optical, manual and TTC agree in estimation of velocity at relatively low flow rate, however with an increase in infusion rate the optical flow method yielded the velocity estimates that were lower than the TTC and manual velocity estimates. We suggest that this difference was due to the fact that slower moving particles close to the channel wall were better illuminated than faster particles deeper in the channel which affected the optical flow analysis. Combined velocity/aggregation appraisal using TTC provides an efficient approach for estimating erythrocyte aggregation appropriate for in-vivo applications. We demonstrated that the optical flow and TTC analyses can be used to estimate erythrocyte velocity and aggregation both in ex-vivo microfluidics laboratory experiments as well as in-vivo recordings. The simplicity of TTC method may be advantageous for developing velocity estimate methods to be used in the clinic. The trade-off is that TTC estimation cannot capture features of the flow based on optical flow analysis of individually tracked particles.


Subject(s)
Erythrocyte Aggregation , Optic Flow , Data Visualization , Erythrocyte Deformability , Erythrocytes , Hemorheology
9.
Clin Appl Thromb Hemost ; 28: 10760296211072820, 2022.
Article in English | MEDLINE | ID: mdl-35018865

ABSTRACT

BACKGROUND: Patients with end-stage renal disease (ESRD) often present with an increased risk of cardiovascular disease. Conditions of compromised cardiovascular health such as atrial fibrillation (AFIB) and peripheral arterial disease (PAD) may alter biomarker levels in a way that reflects worsening ESRD. This study profiled biomarkers and laboratory parameters of endothelium dysfunction in patients with ESRD, categorized by additional AFIB and PAD conditions. METHODS: Citrated blood samples were collected from 95 patients with ESRD. Biomarker levels were measured from plasma samples using sandwich ELISAs, including tissue plasminogen activator (tPA), D-dimer, and nitrotyrosine. Lab parameters, including BUN, calcium, creatinine, parathyroid hormone, phosphate, alkaline phosphatase, ferritin, transferrin, and total iron capacity, and patient comorbidities were obtained from patient medical records. The comorbidities were determined through provider notes, and evidence of applicable testing. RESULTS: 14.89% of patients were found to have atrial fibrillation (n = 14), 30.85% of patients were found to have peripheral arterial disease (n = 29), and 6.38% of patients were found to have both peripheral arterial disease and atrial fibrillation (n = 6). When compared to patients with only ESRD, patients with ESRD and PAD showed elevated levels of D-Dimer (p = .0314) and nitrotyrosine (p = .0330). When compared to patients with only ESRD, patients with atrial fibrillation showed elevated levels of D-Dimer (p = .0372), nitrotyrosine (p = .0322), and tPA (p = .0198). CONCLUSION: When compared to patients with just ESRD, patients with concomitant PAD had elevated levels of Nitrotyrosine and D-dimer; while patients with concomitant Afib had elevated levels of nitrotyrosine, D-dimer, as well as tPA.


Subject(s)
Cardio-Renal Syndrome/etiology , Fibrin Fibrinogen Degradation Products/metabolism , Kidney Failure, Chronic/complications , Aged , Biomarkers/blood , Cardio-Renal Syndrome/blood , Cardio-Renal Syndrome/epidemiology , Female , Humans , Incidence , Kidney Failure, Chronic/epidemiology , Kidney Failure, Chronic/therapy , Male , Middle Aged , Renal Dialysis/methods , Risk Factors , United States/epidemiology
10.
Lab Chip ; 21(19): 3707-3714, 2021 09 28.
Article in English | MEDLINE | ID: mdl-34350927

ABSTRACT

Thrombosis is a common medical entity associated with many forms of cardiovascular disease including myocardial infarction and stroke. Recently, ultrasound thrombolysis has emerged as a promising technique for thrombosis treatment by delivering acoustic waves onto blood clots. In this study, an ultrasound thrombolysis method is presented using an acoustic bubble-based microfluidic device. With acoustic actuation, microstreaming flow is created in the microchannel by oscillating bubbles, breaking up the blood clots in blood samples in a few milliseconds. In a low-frequency field, the effects of bubble size on microstreaming patterns and thrombolysis have been experimentally studied. Using image processing techniques, we have quantitatively investigated the relationship between the input signal and the thrombolysis performance. Additionally, the viability test proved that there are no significant detrimental effects on the blood cells after acoustic actuation. This acoustic bubble-based microfluidic device is demonstrated to be a promising platform for quantitative analysis of ultrasound thrombolysis. It opens up possibilities for future development of ultrasound thrombolysis devices for the diagnosis and treatment of heart diseases.


Subject(s)
Lab-On-A-Chip Devices , Thrombosis , Acoustics , Humans , Thrombolytic Therapy , Thrombosis/diagnostic imaging , Thrombosis/therapy , Ultrasonography
11.
Cardiovasc Revasc Med ; 21(5): 682-683, 2020 05.
Article in English | MEDLINE | ID: mdl-32600797
13.
J Spinal Cord Med ; 41(3): 326-336, 2018 05.
Article in English | MEDLINE | ID: mdl-28614985

ABSTRACT

OBJECTIVE: To optimize maximal respiratory responses with surface stimulation over abdominal and upper thorax muscles and using a 12-Channel Neuroprosthetic Platform. METHODS: Following instrumentation, six anesthetized adult canines were hyperventilated sufficiently to produce respiratory apnea. Six abdominal tests optimized electrode arrangements and stimulation parameters using bipolar sets of 4.5 cm square electrodes. Tests in the upper thorax optimized electrode locations, and forelimb moment was limited to slight-to-moderate. During combined muscle stimulation tests, the upper thoracic was followed immediately by abdominal stimulation. Finally, a model of glottal closure for cough was conducted with the goal of increased peak expiratory flow. RESULTS: Optimized stimulation of abdominal muscles included three sets of bilateral surface electrodes located 4.5 cm dorsal to the lateral line and from the 8th intercostal space to caudal to the 13th rib, 80 or 100 mA current, and 50 Hz stimulation frequency. The maximal expired volume was 343 ± 23 ml (n=3). Optimized upper thorax stimulation included a single bilateral set of electrodes located over the 2nd interspace, 60 to 80 mA, and 50 Hz. The maximal inspired volume was 304 ± 54 ml (n=4). Sequential stimulation of the two muscles increased the volume to 600 ± 152 ml (n=2), and the glottal closure maneuver increased the flow. CONCLUSIONS: Studies in an adult canine model identified optimal surface stimulation methods for upper thorax and abdominal muscles to induce sufficient volumes for ventilation and cough. Further study with this neuroprosthetic platform is warranted.


Subject(s)
Abdominal Muscles/innervation , Cough/physiopathology , Respiration , Respiratory Insufficiency/physiopathology , Respiratory Muscles/innervation , Spinal Cord Injuries/complications , Transcutaneous Electric Nerve Stimulation/methods , Abdominal Muscles/physiopathology , Animals , Dogs , Male , Respiratory Insufficiency/etiology , Respiratory Insufficiency/therapy , Respiratory Muscles/physiopathology , Transcutaneous Electric Nerve Stimulation/adverse effects
16.
J Vasc Surg ; 64(4): 1002-8, 2016 10.
Article in English | MEDLINE | ID: mdl-27444365

ABSTRACT

BACKGROUND: The structural limitations of currently available laser-cut nitinol stents in the highly diseased arterial system of the lower extremity are well described. These devices are frequently used in long-segment occlusions, at the adductor hiatus, and across the knee into the popliteal artery and tibial-peroneal trunk despite concerns related to the high mobility of the knee joint and the potential for external stent compression, fractures, and occlusion. The Supera stent (Abbott Vascular, Santa Clara, Calif) was developed to provide superior radial strength, fracture resistance, and flexibility compared with laser-cut nitinol stents. This study represents the initial U.S. experience in the management of lower extremity artery atherosclerotic disease with the Supera interwoven wire stent. METHODS: Patients undergoing stent implantation in the 20-month period after the 2008 Food and Drug Administration clearance were included. Medical records, radiographic imaging, and procedural data were examined. Procedural angiograms were classified according to TransAtlantic Inter-Society Consensus criteria. Patency and limb loss rates were calculated using Kaplan-Meier analysis. RESULTS: There were 305 stents implanted in 147 patients. Clinical follow-up was a mean of 12.7 months (range, 0.2-33.7 months), and radiologic follow-up was a mean of 8.4 months (range, 0.2-26.8 months). Most patients had critical limb ischemia, with tissue loss (38.1%) or rest pain (28.6%) as the indication for intervention. Of the 147 patients, 75 (51.02%) underwent a concomitant adjunctive procedure in the treated extremity. Primary, assisted primary, and secondary patency rates at 12 months by duplex ultrasound imaging were 89.8%, 91.2%, and 93.2%, respectively, by Kaplan-Meier estimates, with a mean lesion length of 184.5 ± 131.80 mm and mean stented length of 197.5 ± 113.65 mm. Seventeen patients experienced an event requiring successful reintervention in the stented segment (13 for type I or II restenosis; four for type III). There were eight major amputations, with five of those eight having a patent stent at the time of limb sacrifice. The overall mortality was 11.6% during the study period. Knee radiography was performed in 47 patients with devices extending into the popliteal and tibial-peroneal segment, and no stent fractures were identified. CONCLUSIONS: Stenting of the superficial femoral and popliteal arteries using the Supera stent system appears to be safe and effective. The interwoven stent design may better serve areas under extreme mechanical stress. Our results with this population of highly diseased patients including very long lesion lengths are consistent with outcomes of other publications reporting the use of this device.


Subject(s)
Endovascular Procedures/instrumentation , Femoral Artery , Intermittent Claudication/therapy , Ischemia/therapy , Peripheral Arterial Disease/therapy , Popliteal Artery , Stents , Aged , Aged, 80 and over , Alloys , Amputation, Surgical , Arizona , Critical Illness , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Intermittent Claudication/diagnostic imaging , Intermittent Claudication/mortality , Intermittent Claudication/physiopathology , Ischemia/diagnostic imaging , Ischemia/mortality , Ischemia/physiopathology , Kaplan-Meier Estimate , Limb Salvage , Male , Middle Aged , Multivariate Analysis , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/mortality , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Proportional Hazards Models , Prospective Studies , Prosthesis Design , Registries , Retreatment , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
19.
Cardiol Clin ; 33(1): 89-98, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25439333

ABSTRACT

Significant advances have been made in the endovascular treatment of lower extremity arterial occlusive disease. Since the 2011 update, technologies has developed and allowed for the revascularization of complex vascular lesions. Although this technical success is encouraging, these technologies must provide measurable long-term clinical success at a reasonable cost. Large, randomized, controlled trials need to be designed to focus on clinical outcomes and success rates for treatment. These future studies will serve as the guide by which clinicians can provide the most successful clinical and cost effect care in treating patients with lower-extremity peripheral artery disease.


Subject(s)
Arterial Occlusive Diseases/therapy , Endovascular Procedures/instrumentation , Endovascular Procedures/methods , Adult , Aged , Arterial Occlusive Diseases/diagnosis , Arterial Occlusive Diseases/epidemiology , Cross-Sectional Studies , Equipment Design , Female , Humans , Male , Middle Aged , Treatment Outcome , United States
20.
Catheter Cardiovasc Interv ; 85(2): 181-91, 2015 Feb 01.
Article in English | MEDLINE | ID: mdl-25370476

ABSTRACT

The rationale to perform left ventriculography at the time of cardiac catheterization has been little studied. The technique and frequency of use of left ventriculography vary by geographic regions, institutions, and individuals. Despite the recent publication of guidelines and appropriate use criteria for coronary angiography, revascularization, and noninvasive imaging, to date there have been no specific guidelines on the performance of left ventriculography. When left ventriculography is performed, proper technique must be used to generate high quality data which can direct patient management. The decision to perform left ventriculography in place of, or in addition to, other forms of ventricular assessment should be made taking into account the clinical context and the type of information each study provides. This paper attempts to show the role of left ventriculography at the time of coronary angiography or left heart catheterization. The recommendations in this document are not formal guidelines but are based on the consensus of this writing group. These recommendations should be tested through clinical research studies. Until such studies are performed, the writing group believes that adoption of these recommendations will lead to a more standardized application of ventriculography and improve the quality of care provided to cardiac patients. © 2014 Wiley Periodicals, Inc.


Subject(s)
Cardiac Catheterization/standards , Coronary Angiography/standards , Heart Ventricles , Multimodal Imaging/standards , Radionuclide Ventriculography/standards , Ventricular Dysfunction, Left/diagnosis , Ventricular Function, Left , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Predictive Value of Tests , Prognosis , Risk Factors , Stroke Volume , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL