1.
Spine (Phila Pa 1976) ; 41(1): 3-8, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26335669

ABSTRACT

STUDY DESIGN: This was a prospective, randomized, controlled, multicenter study. OBJECTIVE: The purpose of this study was to compare outcomes of two lumbar total disc replacements (TDRs) at 5-year follow-up and report results of serum ion level analysis in a subgroup of patients receiving a metal-on-metal implant. SUMMARY OF BACKGROUND DATA: Lumbar TDR has been compared with fusion in several randomized studies, finding TDR noninferior to fusion and superior on some measures. Receiving less attention has been comparing TDR devices. Additionally, there is concern about metal-on-metal implants, with little data available for spine devices. METHODS: The study included 204 patients receiving Kineflex-L (investigational) and 190 receiving CHARITÉ (control). Outcome measure included Oswestry Disability Index, visual analog pain scales (VAS), patient satisfaction, neurological status, complications, reoperations, and a composite success score. Radiographic assessment included range of motion, subsidence, and heterotrophic ossification. In 32 investigational patients, serum ion analysis was performed for cobalt and chromium. These values were compared with Medicines and Healthcare Products Regulatory Agency values to merit monitoring total hip replacement patients for potential wear problems. RESULTS: Mean Oswestry and VAS scores in both groups improved significantly by 6 weeks and remained improved during 5-year follow-up (Oswestry Disability Index, scores in both groups were approximately 60 preoperatively vs. 20 at 2- and 5-year follow-up; P < 0.01; VAS scores improved >50% by 6 weeks and remained significantly improved; P < 0.05). Approximately 11% of both groups underwent reoperation. Radiographic analysis found segmental range of motion decreased at 3 month, then increased through 24 months, and was maintained thereafter. Serum ion level analysis found the greatest mean value at any follow-up point was less than 20% of Medicines and Healthcare Products Regulatory Agency recommended minimum value to merit monitoring hip replacement patients. CONCLUSION: This prospective, randomized study comparing two TDRs found no significant differences in outcomes during 5-year follow-up. Both provided statistically significant improvements by 6 weeks that were maintained. This results support other studies. Serum ion levels in TDR patients were well below the recommended threshold levels to merit monitoring.


Subject(s)
Lumbar Vertebrae/surgery , Prostheses and Implants/statistics & numerical data , Total Disc Replacement/adverse effects , Total Disc Replacement/statistics & numerical data , Adult , Chromium/blood , Cobalt/blood , Follow-Up Studies , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/physiopathology , Prostheses and Implants/adverse effects , Radiography , Range of Motion, Articular , Total Disc Replacement/instrumentation , Treatment Outcome
2.
Spine (Phila Pa 1976) ; 39(12): 925-31, 2014 May 20.
Article in English | MEDLINE | ID: mdl-24718066

ABSTRACT

STUDY DESIGN: This was a prospective, randomized, controlled multicenter study with 24-month follow-up. OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy in a Food and Drug Administration Investigation Device Exemption of a new lumbar total disc replacement (TDR) by comparing it to an earlier TDR approved for sale. SUMMARY OF BACKGROUND DATA: Randomized trials have reported TDR to produce results similar or superior to lumbar fusion. Results for various TDRs seem to be similar, but differences in study design and outcome measures pose challenges in definitively comparing devices. The purpose of this study was to perform a direct comparison of 2 lumbar TDRs in a prospective, randomized trial. METHODS: TDR was performed in 457 patients from 21 sites (261 patients in the investigational group (Kineflex-L Disc; metal-on-metal design anchored with keels, 204 randomized and 57 nonrandomized training cases), and 196 in the control group (CHARITE artificial disc; metal with polyethylene core with teeth for anchoring; 190 randomized and 6 nonrandomized training cases). All patients were treated nonoperatively for single-level symptomatic disc degeneration for at least 6 months prior to surgery. Perioperative data were collected. Clinical outcome data were collected prospectively, as approved by the Food and Drug Administration, through 24-month follow-up. Primary outcome measures used were the Oswestry Disability Index, visual analogue scales assessing pain, patient satisfaction, and reoperations. Success was defined to be at least 15-point improvements in Oswestry Disability Index scores, no reoperation, and no major adverse events. Radiographical measures included range of motion, disc space height, and assessment for device migration, subsidence, and fusion at the TDR level. RESULTS: There were no significant differences between the groups when comparing operative time, blood loss, or length of hospital stay. Both groups improved significantly on Oswestry Disability Index and visual analogue scale scores (P < 0.01) with no differences between the groups. Success rates were similar (68.1% investigational vs. 67.4% control). At 24-month follow-up, 94.1% of the investigational group and 91.9% of controls were satisfied with outcome. Reoperation was performed in 10.3% of the investigational group and 8.4% of the control group. CONCLUSION: This prospective, randomized, controlled study comparing 2 TDRs, the first to the authors' knowledge, found the devices produced very similar clinical outcomes. Both groups improved significantly by 6 weeks postoperatively and remained improved throughout follow-up with a high patient satisfaction rate.


Subject(s)
Intervertebral Disc Degeneration/surgery , Lumbar Vertebrae/surgery , Total Disc Replacement/instrumentation , Adolescent , Adult , Disability Evaluation , Equipment Design , Female , Follow-Up Studies , Humans , Lumbar Vertebrae/diagnostic imaging , Male , Middle Aged , Patient Satisfaction , Postoperative Complications , Prospective Studies , Radiography , Range of Motion, Articular , Reoperation , Treatment Outcome , Young Adult
SELECTION OF CITATIONS