1.
Front Oncol ; 14: 1328147, 2024.
Article in English | MEDLINE | ID: mdl-38482200

ABSTRACT

Purpose: This study develop a novel linear energy transfer (LET) optimization method for intensity-modulated proton therapy (IMPT) with minimum monitor unit (MMU) constraint using the alternating direction method of multipliers (ADMM). Material and methods: The novel LET optimization method (ADMM-LET) was proposed with (1) the dose objective and the LET objective as the optimization objective and (2) the non-convex MMU threshold as a constraint condition. ADMM was used to solve the optimization problem. In the ADMM-LET framework, the optimization process entails iteratively solving the dose sub-problem and the LET sub-problem, simultaneously ensuring compliance with the MMU constraint. Three representative cases, including brain, liver, and prostate cancer, were utilized to evaluate the performance of the proposed method. The dose and LET distributions from ADMM-LET were compared to those obtained using the published iterative convex relaxation (ICR-LET) method. Results: The results demonstrate the superiority of ADMM-LET over ICR-LET in terms of LET distribution while achieving a comparable dose distribution. More specifically, for the brain case, the maximum LET (unit: keV/µm) at the optic nerve decreased from 5.45 (ICR-LET) to 1.97 (ADMM-LET). For the liver case, the mean LET (unit: keV/µm) at the clinical target volume increased from 4.98 (ICR-LET) to 5.50 (ADMM-LET). For the prostate case, the mean LET (unit: keV/µm) at the rectum decreased from 2.65 (ICR-LET) to 2.14 (ADMM-LET). Conclusion: This study establishes ADMM-LET as a new approach for LET optimization with the MMU constraint in IMPT, offering potential improvements in treatment outcomes and biological effects.

2.
Phys Med Biol ; 69(5)2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38324904

ABSTRACT

Objective. Proton therapy reduces the integral dose to the patient compared to conventional photon treatments. However,in vivoproton range uncertainties remain a considerable hurdle. Range uncertainty reduction benefits depend on clinical practices. During intensity-modulated proton therapy (IMPT), the target is irradiated from only a few directions, but proton arc therapy (PAT), for which the target is irradiated from dozens of angles, may see clinical implementation by the time considerable range uncertainty reductions are achieved. It is therefore crucial to determine the impact of PAT on range uncertainty reduction benefits.Approach. For twenty head-and-neck cancer patients, four different treatment plans were created: an IMPT and a PAT treatment plan assuming current clinical range uncertainties of 3.5% (IMPT3.5%and PAT3.5%), and an IMPT and a PAT treatment plan assuming that range uncertainties can be reduced to 1% (IMPT1%and PAT1%). Plans were evaluated with respect to target coverage and organ-at-risk doses as well as normal tissue complication probabilities (NTCPs) for parotid glands (endpoint: parotid gland flow <25%) and larynx (endpoint: larynx edema).Main results. Implementation of PAT (IMPT3.5%-PAT3.5%) reduced mean NTCPs in the nominal and worst-case scenario by 3.2 percentage points (pp) and 4.2 pp, respectively. Reducing range uncertainties from 3.5% to 1% during use of IMPT (IMPT3.5%-IMPT1%) reduced evaluated NTCPs by 0.9 pp and 2.0 pp. Benefits of range uncertainty reductions subsequently to PAT implementation (PAT3.5%-PAT1%) were 0.2 pp and 1.0 pp, with considerably higher benefits in bilateral compared to unilateral cases.Significance. The mean clinical benefit of implementing PAT was more than twice as high as the benefit of a 3.5%-1% range uncertainty reduction. Range uncertainty reductions are expected to remain beneficial even after PAT implementation, especially in cases with target positions allowing for full leveraging of the higher number of gantry angles during PAT.


Subject(s)
Head and Neck Neoplasms , Proton Therapy , Humans , Proton Therapy/methods , Protons , Uncertainty , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk , Head and Neck Neoplasms/radiotherapy
3.
Med Phys ; 2024 Feb 10.
Article in English | MEDLINE | ID: mdl-38340368

ABSTRACT

BACKGROUND: Spot-scanning Proton Arc (SPArc) has been of significant interest in recent years because of its superior plan quality. Currently, the primary focus of research and development is on deliverability and treatment efficiency. PURPOSE: To address the challenges in generating a deliverable and efficient SPArc plan for a proton therapy system with a massive gantry, we developed a novel SPArc optimization algorithm (SPArcDMPO ) by directly incorporating the machine-specific parameters such as gantry mechanical constraints and proton delivery sequence. METHODS: SPArc delivery sequence model (DSMarc ) was built based on the machine-specific parameters of the prototype arc delivery system, IBA ProteusONE®, including mechanical constraint (maximum gantry speed, acceleration, and deceleration) and proton delivery sequence (energy and spot delivery sequence, and irradiation time). SPArcDMPO resamples and adjusts each control point's delivery speed based on the DSMarc calculation through the iterative approach. In SPArcDMPO, users could set a reasonable arc delivery time during the plan optimization, which aims to minimize the gantry momentum changes and improve the delivery efficiency. Ten cases were selected to test SPArcDMPO . Two kinds of SPArc plans were generated using the same planning objective functions: (1) original SPArc plan (SPArcoriginal ); (2) SPArcDMPO plan with a user-pre-defined delivery time. Additionally, arc delivery sequence was simulated based on the DSMarc and was compared. Treatment delivery time was compared between SPArcoriginal and SPArcDMPO . Dynamic arc delivery time, the static irradiation time, and its corresponding time differential (time differential = dynamic arc delivery time-static irradiation time) were analyzed, respectively. The total gantry velocity change was accumulated throughout the treatment delivery. RESULTS: With a similar plan quality, objective value, number of energy layers, and spots, both SPArcoriginal and SPArcDMPO plans could be delivered continuously within the ± 1 degree tolerance window. However, compared to the SPArcoriginal , the strategy of SPArcDMPO is able to reduce the time differential from 30.55 ± 11.42%(90 ± 32 s) to 14.67 ± 6.97%(42 ± 20 s), p < 0.01. Furthermore, the corresponding total variations of gantry velocity during dynamic arc delivery are mitigated (SPArcoriginal vs. SPArcDMPO ) from 14.73 ± 9.14 degree/s to 4.28 ± 2.42 degree/s, p < 0.01. Consequently, the SPArcDMPO plans could minimize the gantry momentum change based on the clinical user's input compared to the SPArcoriginal plans, which could help relieve the mechanical challenge of accelerating or decelerating the massive proton gantry. CONCLUSIONS: For the first time, clinical users not only could generate a SPArc plan meeting the mechanical constraint of their proton system but also directly control the arc treatment speed and momentum changes of the gantry during the plan optimization process. This work paved the way for the routine clinical implementation of proton arc therapy in the treatment planning system.

4.
Med Phys ; 51(4): 3067-3075, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38064634

ABSTRACT

BACKGROUND: Spot-scanning proton arc (SPArc) has been drawing significant interests in recent years because of its capability of continuous proton irradiation during the gantry rotation. Previous studies demonstrated SPArc plans were delivered on a prototype of the DynamicARC solution, IBA ProteusONE. PURPOSE: We built a novel delivery sequence model through an independent experimental approach: the first SPArc delivery sequence model (DSMSPArc). Based on the model, we investigated SPArc treatment efficiency improvement in the routine proton clinical operation. METHODS: SPArc test plans were generated and delivered on a prototype of the DynamicARC solution, IBA ProteusONE. An independent gantry inclinometer and the machine logfiles were used to derive the DSMSPArc. Seventeen SPArc plans were used to validate the model's accuracy independently. Two random clinical operation dates (6th January and 22nd March, 2021) from a single-room proton therapy center (PTC) were selected to quantitatively assess the improvement of treatment efficiency compared to the IMPT. RESULTS: The difference between the logfile and DSMSPArc is about 3.2 ± 4.8%. SPArc reduced 58.1% of the average treatment delivery time per patient compared to IMPT (p < 0.01). Daily treatment throughput could be increased by 30% using SPArc using a single-room proton therapy system. CONCLUSIONS: The first model of dynamic arc therapy is established in this study through an independent experimental approach using logfiles and measurements which allows clinical users and investigators to simulate the dynamic treatment delivery and assess the daily treatment throughput improvement.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Humans , Protons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
5.
Phys Med Biol ; 69(1)2023 Dec 22.
Article in English | MEDLINE | ID: mdl-38041874

ABSTRACT

Objective.Delivery efficiency is the bottleneck of spot-scanning proton arc therapy (SPArc) because of the numerous energy layers (ELs) ascending switches. This study aims to develop a new algorithm to mitigate the need for EL ascending via water equivalent thickness (WET) sector selection followed by particle swarm optimization (SPArc-particle swarm).Approach.SPArc-particle swarmdivided the full arc trajectory into the optimal sectors based on K-means clustering analysis of the relative mean WET. Within the sector, particle swarm optimization was used to minimize the total energy switch time, optimizing the energy selection integrated with the EL delivery sequence and relationship. This novel planning framework was implemented on the open-source platform matRad (Department of Medical Physics in Radiation Oncology, German Cancer Research Center-DKFZ). Three representative cases (brain, liver, and prostate cancer) were selected for testing purposes. Two kinds of plans were generated: SPArc_seq and SPArc-particle swarm. The plan quality and delivery efficiency were evaluated.Main results. With a similar plan quality, the delivery efficiency was significantly improved using SPArc-particle swarmcompared to SPArc_seq. More specifically, it reduces the number of ELs ascending switching compared to the SPArc_seq (from 21 to 7 in the brain, from 21 to 5 in the prostate, from 21 to 6 in the liver), leading to a 16%-26% reduction of the beam delivery time (BDT) in the SPArc treatment.Significance. A novel planning framework, SPArc-particle swarm, could significantly improve the delivery efficiency, which paves the roadmap towards routine clinical implementation.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Humans , Male , Radiotherapy Dosage , Protons , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Algorithms , Proton Therapy/methods
6.
Phys Med Biol ; 68(21)2023 10 19.
Article in English | MEDLINE | ID: mdl-37774715

ABSTRACT

Objective. To investigate the impact of various delivery tolerance window settings on the treatment delivery time and dosimetric accuracy of spot-scanning proton arc (SPArc) therapy.Approach. SPArc plans were generated for three representative disease sites (brain, lung, and liver cancer) with an angle sampling frequency of 2.5°. An in-house dynamic arc controller was used to simulate the arc treatment delivery with various tolerance windows (±0.25, ±0.5, ±1, and ±1.25°). The controller generates virtual logfiles during the arc delivery simulation, such as gantry speed, acceleration and deceleration, spot position, and delivery sequence, similar to machine logfiles. The virtual logfile was then imported to the treatment planning system to reconstruct the delivered dose distribution and compare it to the initial SPArc nominal plan. A three-dimensional gamma index was used to quantitatively assess delivery accuracy. Total treatment delivery time and relative lost time (dynamic arc delivery time-fix beam delivery time)/fix beam delivery time) were reported.Main Results. The 3D gamma passing rate (GPR) was greater than 99% for all cases when using 3%/3 mm and 2%/2 mm criteria and the GPR (1%/1 mm criteria) degraded as the tolerance window opens. The total delivery time for dynamic arc delivery increased with the decreasing delivery tolerance window length. The average delivery time and the relative lost time (%) were 630 ± 212 s (253% ± 68%), 322 ± 101 s (81% ± 31%), 225 ± 60 s (27% ± 16%), 196 ± 41 s (11% ± 6%), 187 ± 29 s (6% ± 1%) for tolerance windows ±0.25, ±0.5, ±1, and ±1.25° respectively.Significance. The study quantitatively analyzed the dynamic SPArc delivery time and accuracy with different delivery tolerance window settings, which offer a critical reference in the future SPArc plan optimization and delivery controller design.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Protons , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Brain , Radionuclide Imaging , Radiotherapy Dosage , Proton Therapy/methods
8.
Int J Radiat Oncol Biol Phys ; 117(3): 730-737, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37196836

ABSTRACT

PURPOSE: To take full advantage of FLASH dose rate (40 Gy/s) and high-dose conformity, we introduce a novel optimization and delivery technique, the spot-scanning proton arc therapy (SPArc) + FLASH (SPLASH). METHODS AND MATERIALS: SPLASH framework was implemented in an open-source proton planning platform (MatRad, Department of Medical Physics in Radiation Oncology, German Cancer Research Center). It optimizes with the clinical dose-volume constraint based on dose distribution and the dose-average dose rate by minimizing the monitor unit constraint on spot weight and accelerator beam current sequentially, enabling the first dynamic arc therapy with voxel-based FLASH dose rate. This new optimization framework minimizes the overall cost function value combined with plan quality and voxel-based dose-rate constraints. Three representative cases (brain, liver, and prostate cancer) were used for testing purposes. Dose-volume histogram, dose-rate-volume histogram, and dose-rate map were compared among intensity modulated proton radiation therapy (IMPT), SPArc, and SPLASH. RESULTS: SPLASH/SPArc could offer superior plan quality over IMPT in terms of dose conformity. The dose-rate-volume histogram results indicated SPLASH could significantly improve V40 Gy/s in the target and region of interest for all tested cases compared with SPArc and IMPT. The optimal beam current per spot is simultaneously generated, which is within the existing proton machine specifications in the research version (<200 nA). CONCLUSIONS: SPLASH offers the first voxel-based ultradose-rate and high-dose conformity treatment using proton beam therapy. Such a technique has the potential to fit the needs of a broad range of disease sites and simplify clinical workflow without applying a patient-specific ridge filter, which has never before been demonstrated.


Subject(s)
Prostatic Neoplasms , Proton Therapy , Radiotherapy, Intensity-Modulated , Male , Humans , Proton Therapy/methods , Protons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy
10.
Med Phys ; 50 Suppl 1: 95-103, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36756953

ABSTRACT

As we were invited to write an article for celebrating the 50th Anniversary of Medical Physics journal, on something historically significant, commemorative, and exciting happening in the past decades, the first idea came to our mind is the fascinating radiotherapy paradigm shift from conventional fractionation to hypofractionation and stereotactic ablative radiotherapy (SABR). It is historically and clinically significant since as we all know this RT treatment revolution not only reduces treatment duration for patients, but also improves tumor control and cancer treatment outcomes. It is also commemorative and exciting for us medical physicists since the technology development in medical physics has been the main driver for the success of this treatment regimen which requires high precision and accuracy throughout the entire treatment planning and delivery. This article provides an overview of the technological development and clinical trials evolvement in the past 25 years for hypofractionation and SABR, with an outlook to the future improvement.


Subject(s)
Neoplasms , Radiosurgery , Humans , Radiation Dose Hypofractionation , Radiosurgery/adverse effects , Neoplasms/radiotherapy , Dose Fractionation, Radiation , Physics
11.
Phys Med Biol ; 68(4)2023 02 17.
Article in English | MEDLINE | ID: mdl-36716492

ABSTRACT

Objective.To demonstrates the ability of an ultra-fast imaging system to measure high resolution spatial and temporal beam characteristics of a synchrocyclotron proton pencil beam scanning (PBS) system.Approach.An ultra-fast (1 kHz frame rate), intensified CMOS camera was triggered by a scintillation sheet coupled to a remote trigger unit for beam on detection. The camera was calibrated using the linear (R2> 0.9922) dose response of a single spot beam to varying currents. Film taken for the single spot beam was used to produce a scintillation intensity to absolute dose calibration.Main results. Spatial alignment was confirmed with the film, where thexandy-profiles of the single spot cumulative image agreed within 1 mm. A sample brain patient plan was analyzed to demonstrate dose and temporal accuracy for a clinically-relevant plan, through agreement within 1 mm to the planned and delivered spot locations. The cumulative dose agreed with the planned dose with a gamma passing rate of 97.5% (2 mm/3%, 10% dose threshold).Significance. This is the first system able to capture single-pulse spatial and temporal information for the unique pulse structure of a synchrocyclotron PBS systems at conventional dose rates, enabled by the ultra-fast sampling frame rate of this camera. This study indicates that, with continued camera development and testing, target applications in clinical and FLASH proton beam characterization and validation are possible.


Subject(s)
Proton Therapy , Protons , Humans , Cyclotrons , Radiotherapy Dosage , Proton Therapy/methods , Diagnostic Imaging , Radiotherapy Planning, Computer-Assisted/methods
12.
Phys Med Biol ; 67(24)2022 12 13.
Article in English | MEDLINE | ID: mdl-36541505

ABSTRACT

Objective. Proton arc therapy (PAT) is a new delivery technique that exploits the continuous rotation of the gantry to distribute the therapeutic dose over many angular windows instead of using a few static fields, as in conventional (intensity-modulated) proton therapy. Although coming along with many potential clinical and dosimetric benefits, PAT has also raised a new optimization challenge. In addition to the dosimetric goals, the beam delivery time (BDT) needs to be considered in the objective function. Considering this bi-objective formulation, the task of finding a good compromise with appropriate weighting factors can turn out to be cumbersome.Approach. We have computed Pareto-optimal plans for three disease sites: a brain, a lung, and a liver, following a method of iteratively choosing weight vectors to approximate the Pareto front with few points. Mixed-integer programming (MIP) was selected to state the bi-criteria PAT problem and to find Pareto optimal points with a suited solver.Main results. The trade-offs between plan quality and beam irradiation time (staticBDT) are investigated by inspecting three plans from the Pareto front. The latter are carefully picked to demonstrate significant differences in dose distribution and delivery time depending on their location on the frontier. The results were benchmarked against IMPT and SPArc plans showing the strength of degrees of freedom coming along with MIP optimization.Significance. This paper presents for the first time the application of bi-criteria optimization to the PAT problem, which eventually permits the planners to select the best treatment strategy according to the patient conditions and clinical resources available.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Humans , Proton Therapy/methods , Protons , Radiotherapy Planning, Computer-Assisted/methods , Radiometry , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage
13.
Phys Med Biol ; 68(1)2022 12 22.
Article in English | MEDLINE | ID: mdl-36546347

ABSTRACT

Objective. Proton dosimetric uncertainties resulting from the patient's daily setup errors in rotational directions exist even with advanced image-guided radiotherapy techniques. Thus, we developed a new rotational robust optimization SPArc algorithm (SPArcrot) to mitigate the dosimetric impact of the rotational setup error in Raystation ver. 6.02 (RaySearch Laboratory AB, Stockholm, Sweden).Approach.The initial planning CT was rotated ±5° simulating the worst-case setup error in the roll direction. The SPArcrotuses a multi-CT robust optimization framework by taking into account of such rotational setup errors. Five cases representing different disease sites were evaluated. Both SPArcoriginaland SPArcrotplans were generated using the same translational robust optimized parameters. To quantitatively investigate the mitigation effect from the rotational setup errors, all plans were recalculated using a series of pseudo-CT with rotational setup error (±1°/±2°/±3°/±5°). Dosimetric metrics such as D98% of CTV, and 3D gamma analysis were used to assess the dose distribution changes in the target and OARs.Main results.The magnitudes of dosimetric changes in the targets due to rotational setup error were significantly reduced by the SPArcrotcompared to SPArc in all cases. The uncertainties of the max dose to the OARs, such as brainstem, spinal cord and esophagus were significantly reduced using SPArcrot. The uncertainties of the mean dose to the OARs such as liver and oral cavity, parotid were comparable between the two planning techniques. The gamma passing rate (3%/3 mm) was significantly improved for CTV of all tumor sites through SPArcrot.Significance.Rotational setup error is one of the major issues which could lead to significant dose perturbations. SPArcrotplanning approach can consider such rotational error from patient setup or gantry rotation error by effectively mitigating the dose uncertainties to the target and in the adjunct series OARs.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Humans , Organs at Risk , Protons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Setup Errors , Radiotherapy, Intensity-Modulated/methods , Proton Therapy/methods , Osteonectin
14.
Acta Oncol ; 61(11): 1417-1424, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36305424

ABSTRACT

PURPOSE: To develop an advanced deep convolutional neural network (DCNN) architecture to generate synthetic CT (SCT) images from MR images for intensity-modulated proton therapy (IMPT) treatment planning of nasopharyngeal cancer (NPC) patients. METHODS: T1-weighted MR images and paired CT (PCT) images were obtained from 206 NPC patients. For each patient, deformable image registration was performed between MR and PCT images to create an MR-CT image pair. Thirty pairs were randomly chosen as the independent test set and the remaining 176 pairs (14 for validation and 162 for training) were used to build two conditional generative adversarial networks (GANs): 1) GAN3D: using a 3D U-net enhanced with residual connections and attentional mechanism as the generator and 2) GAN2D: using a 2D U-net as the generator. For each test patient, SCT images were generated using the generators with the MR images as input and were compared with respect to the corresponding PCT image. A clinical IMPT plan was created and optimized on the PCT image. The dose was recalculated on the SCT images and compared with the one calculated on the PCT image. RESULTS: The mean absolute errors (MAEs) between the PCT and SCT, within the body, were (64.89 ± 5.31) HU and (64.31 ± 4.61) HU for the GAN2D and GAN3D. Within the high-density bone (HU > 600), the GAN3D achieved a smaller MAE compared with the GAN2D (p < 0.001). Within the body, the absolute point dose deviation was reduced from (0.58 ± 1.61) Gy for the GAN2D to (0.47 ± 0.94) Gy for the GAN3D. The (3 mm/3%) gamma passing rates were above 97.32% for all SCT images. CONCLUSIONS: The SCT images generated using GANs achieved clinical acceptable dosimetric accuracy for IMPT of NPC patients. Using advanced DCNN architecture design, such as residual connections and attention mechanism, SCT image quality was further improved and resulted in a small dosimetric improvement.


Subject(s)
Nasopharyngeal Neoplasms , Proton Therapy , Radiotherapy, Intensity-Modulated , Humans , Protons , Tomography, X-Ray Computed/methods , Nasopharyngeal Carcinoma/diagnostic imaging , Nasopharyngeal Carcinoma/radiotherapy , Nasopharyngeal Neoplasms/diagnostic imaging , Nasopharyngeal Neoplasms/radiotherapy , Magnetic Resonance Imaging/methods , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Image Processing, Computer-Assisted/methods
15.
Front Oncol ; 12: 812031, 2022.
Article in English | MEDLINE | ID: mdl-35847952

ABSTRACT

Purpose: To investigate the potential clinical benefit of utilizing intensity-modulated proton therapy (IMPT) to reduce acute hematologic toxicity for locally advanced non-small cell lung cancer (LA-NSCLC) patients and explore the feasibility of a model-based patient selection approach via the normal tissue complication probability (NTCP). Methods: Twenty patients with LA-NSCLC were retrospectively selected. Volumetric modulated arc photon therapy (VMAT) and IMPT plans were generated with a prescription dose of 60 Gy in 30 fractions. A wide range of cases with varied tumor size, location, stations of metastatic lymph nodes were selected to represent the general cancer group. Contouring and treatment planning followed RTOG-1308 protocol. Doses to thoracic vertebral bodies (TVB) and other organ at risks were compared. Risk of grade ≥ 3 acute hematologic toxicity (HT3+) were calculated based on the NTCP model, and patients with a reduction on NTCP of HT3+ from VMAT to IMPT (△NTCP_HT3+) ≥ 10% were considered to 'significantly benefit from proton therapy.' Results: Compared to VMAT, IMPT significantly reduced the dose to the TVB, the lung, the heart, the esophagus and the spinal cord. Tumor distance to TVB was significantly associated with △NTCP _HT3+ ≥ 10%. For the patients with tumor distance ≤ 0.7 cm to TVB, the absolute reduction of dose (mean, V30 and V40) to TVB was significantly lower than that in patients with tumor distance > 0.7 cm. Conclusion: IMPT decreased the probability of HT3+ compared to VMAT by reducing the dose to the TVB in LA-NSCLC patients. Patients with tumor distance to TVB less than 0.7 cm are likely to benefit most from proton over photon therapy.

16.
Comput Biol Med ; 148: 105609, 2022 09.
Article in English | MEDLINE | ID: mdl-35803749

ABSTRACT

Arc proton therapy (ArcPT) is an emerging modality in cancer treatments. It delivers the proton beams following a sequence of irradiation angles while the gantry is continuously rotating around the patient. Compared to conventional proton treatments (intensity modulated proton therapy, IMPT), the number of beams is significantly increased bringing new degrees of freedom that leads to potentially better cancer care. However, the optimization of such treatment plans becomes more complex and several alternative statements of the problem can be considered and compared in order to solve the ArcPT problem. Three such problem statements, distinct in their mathematical formulation and properties, are investigated and applied to solving the ArcPT optimization problem. They make use of (i) fast iterative shrinkage-thresholding algorithm (FISTA), (ii) local search (LS) and (iii) mixed-integer programming (MIP). The treatment plans obtained with those methods are compared among them, but also with IMPT and an existing state-of-the-art method: Spot-Scanning Proton Arc (SPArc). MIP stands out at low scale problems both in terms of dose quality and time delivery efficiency. FISTA shows high dose quality but experiences difficulty to optimize the energy sequence while LS is mostly the antagonist. This detailed study describes independent approaches to solve the ArcPT problem and depending on the clinical case, one should be cautiously picked rather than the other. This paper gives the first formal definition of the problem at stake, as well as a first reference benchmark. Finally, empirical conclusions are drawn, based on realistic assumptions.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Algorithms , Humans , Protons , Radiotherapy Planning, Computer-Assisted
17.
Phys Med Biol ; 67(16)2022 08 16.
Article in English | MEDLINE | ID: mdl-35878608

ABSTRACT

Objective. Proton arc plan normally contains thousands of spot numbers and hundreds of energy layers. A recent study reported that the beam delivery time (BDT) is proportional to the spot numbers. Thus, it is critical to find an optimal plan with a fast delivery speed while maintaining a good plan quality. Thus, we developed a novel evolutionary algorithm to directly search for the optimal spot sparsity solution to balance plan quality and BDT.Approach. The planning platform included a plan quality objective, a generator, and a selector. The generator is based on trust-region-reflective solver. A selector was designed to filter or add the spot according to the expected spot number, based on the user's input of BDT. The generator and selector are used alternatively to optimize a spot sparsity solution. Three clinical cases' CT and structure datasets, e.g. brain, lung, and liver cancer, were used for testing purposes. A series of user-defined BDTs from 15 to 250 s were used as direct inputs. The relationship between the plan's cost function value and BDT was evaluated in these three cases.Main results. The evolutionary algorithm could optimize a proton arc plan based on clinical user input BDT directly. The plan quality remains optimal in the brain, lung, and liver cases until the BDT was shorter than 25 s, 50 s and 100 s, respectively. The plan quality degraded as the input delivery time became too short, indicating that the plan lacked enough spot or degree of freedom.Significance. This is the first proton arc planning framework to directly optimize plan quality with the BDT as an input for the new generation of proton therapy systems. This work paved the roadmap for implementing such new technology in a routine clinic and provided a planning platform to explore the trade-off between the BDT and plan quality.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Algorithms , Proton Therapy/methods , Protons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
18.
Front Oncol ; 12: 804036, 2022.
Article in English | MEDLINE | ID: mdl-35664795

ABSTRACT

Purpose: To explore the role of using Pencil Beam Scanning (PBS) proton beam therapy in single lesion brain stereotactic radiosurgery (SRS), we developed and validated a dosimetric in silico model to assist in the selection of an optimal treatment approach among the conventional Volumetric Modulated Arc Therapy (VMAT), Intensity Modulated Proton Therapy (IMPT) and Spot-scanning Proton Arc (SPArc). Material and Methods: A patient's head CT data set was used as an in silico model. A series of targets (volume range from 0.3 cc to 33.03 cc) were inserted in the deep central and peripheral region, simulating targets with different sizes and locations. Three planning groups: IMPT, VMAT, and SPArc were created for dosimetric comparison purposes and a decision tree was built based on this in silico model. Nine patients with single brain metastases were retrospectively selected for validation. Multiple dosimetric metrics were analyzed to assess the plan quality, such as dose Conformity Index (CI) (ratio of the target volume to 100% prescription isodose volume); R50 (ratio of 50% prescription isodose volume to the target volume); V12Gy (volume of brain tissue minus GTV receiving 12 Gy), and mean dose of the normal brain. Normal tissue complication probability (NTCP) of brain radionecrosis (RN) was calculated using the Lyman-Kutcher-Burman (LKB) model and total treatment delivery time was calculated. Six physicians from different institutions participated in the blind survey to evaluate the plan quality and rank their choices. Results: The study showed that SPArc has a dosimetric advantage in the V12Gy and R50 with target volumes > 9.00 cc compared to VMAT and IMPT. A significant clinical benefit can be found in deep centrally located lesions larger than 20.00 cc using SPArc because of the superior dose conformity and mean dose reduction in healthy brain tissue. Nine retrospective clinical cases and the blind survey showed good agreement with the in silico dosimetric model and decision tree. Additionally, SPArc significantly reduced the treatment delivery time compared to VMAT (SPArc 184.46 ± 59.51s vs. VMAT: 1574.78 ± 213.65s). Conclusion: The study demonstrated the feasibility of using Proton beam therapy for single brain metastasis patients utilizing the SPArc technique. At the current stage of technological development, VMAT remains the current standard modality of choice for single lesion brain SRS. The in silico dosimetric model and decision tree presented here could be used as a practical clinical decision tool to assist the selection of the optimal treatment modality among VMAT, IMPT, and SPArc in centers that have both photon and proton capabilities.

20.
Radiat Oncol ; 17(1): 87, 2022 May 07.
Article in English | MEDLINE | ID: mdl-35525993

ABSTRACT

BACKGROUND: A new compact superconducting synchrocyclotron single-room proton solution delivers pulsed proton beams to each spot through several irradiation bursts calculated by an iterative layer delivery algorithm. Such a mechanism results in a new beam parameter, burst switching time (BST) in the total beam delivery time (BDT) which has never been studied before. In this study, we propose an experimental approach to build an accurate BDT and sequence prediction model for this new proton solution. METHODS: Test fields and clinical treatment plans were used to investigate each beam delivery parameter that impacted BDT. The machine delivery log files were retrospectively analyzed to quantitatively model energy layer switching time (ELST), spot switching time (SSWT), spot spill time (SSPT), and BST. A total of 102 clinical IMPT treatment fields' log files were processed to validate the accuracy of the BDT prediction model in comparison with the result from the current commercial system. Interplay effect is also investigated as a clinical application by comparing this new delivery system model with a conventional cyclotron accelerator model. RESULTS: The study finds that BST depends on the amount of data to be transmitted between two sequential radiation bursts, including a machine irradiation log file of the previous burst and a command file to instruct the proton system to deliver the next burst. The 102 clinical treatment fields showed that the accuracy of each component of the BDT matches well between machine log files and BDT prediction model. More specifically, the difference of ELST, SSWT, SSPT, and BST were (- 3.1 ± 5.7)%, (5.9 ± 3.9)%, (2.6 ± 8.7)%, and (- 2.3 ± 5.3)%, respectively. The average total BDT was about (2.1 ± 3.0)% difference compared to the treatment log files, which was significantly improved from the current commercial proton system prediction (58 ± 15)%. Compared to the conventional cyclotron system, the burst technique from synchrocyclotron effectively reduced the interplay effect in mobile tumor treatment. CONCLUSION: An accurate BDT and sequence prediction model was established for this new clinical compact superconducting synchrocyclotron single-room proton solution. Its application could help users of similar facilities better assess the interplay effect and estimate daily patient treatment throughput.


Subject(s)
Proton Therapy , Cyclotrons , Humans , Proton Therapy/methods , Protons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies