Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Neurophysiol ; 38(2): 112-123, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33661787

ABSTRACT

SUMMARY: High-density EEG (HD-EEG) recordings use a higher spatial sampling of scalp electrodes than a standard 10-20 low-density EEG montage. Although several studies have demonstrated improved localization of the epileptogenic cortex using HD-EEG, widespread implementation is impeded by cost, setup and interpretation time, and lack of specific or sufficient procedural billing codes. Despite these barriers, HD-EEG has been in use at several institutions for years. These centers have noted utility in a variety of clinical scenarios where increased spatial resolution from HD-EEG has been required, justifying the extra time and cost. We share select scenarios from several centers, using different recording techniques and software, where HD-EEG provided information above and beyond the standard low-density EEG. We include seven cases where HD-EEG contributed directly to current clinical care of epilepsy patients and highlight two novel techniques which suggest potential opportunities to improve future clinical care. Cases illustrate how HD-EEG allows clinicians to: case 1-lateralize falsely generalized interictal epileptiform discharges; case 2-improve localization of falsely generalized epileptic spasms; cases 3 and 4-improve localization of interictal epileptiform discharges in anatomic regions below the circumferential limit of standard low-density EEG coverage; case 5-improve noninvasive localization of the seizure onset zone in lesional epilepsy; cases 6 and 7-improve localization of the seizure onset zone to guide invasive investigation near eloquent cortex; case 8-identify epileptic fast oscillations; and case 9-map language cortex. Together, these nine cases illustrate that using both visual analysis and advanced techniques, HD-EEG can play an important role in clinical management.


Subject(s)
Brain Mapping/methods , Electroencephalography/methods , Epilepsy/diagnostic imaging , Epilepsy/physiopathology , Adolescent , Adult , Aged , Brain Mapping/trends , Cerebral Cortex/diagnostic imaging , Cerebral Cortex/physiopathology , Child , Electrodes/trends , Electroencephalography/trends , Female , Forecasting , Humans , Infant , Male , Middle Aged , Scalp/diagnostic imaging , Scalp/physiopathology , Seizures/diagnostic imaging , Seizures/physiopathology , Young Adult
2.
J Clin Neurophysiol ; 37(3): 263-270, 2020 May.
Article in English | MEDLINE | ID: mdl-31490287

ABSTRACT

PURPOSE: High-density EEG (HD-EEG) systems and electrical source imaging techniques have revolutionized our ability to assess the potential sources of epileptiform activity and other EEG features. Nonetheless, clinical use of HD-EEG is hampered by the lack of a standardized electrode nomenclature system and the inherent difficulties encountered in visually reviewing recordings. Inefficient visual review of HD-EEG remains a major barrier to incorporating these techniques into routine clinical care. METHODS: Extension of the 10-10 is first defined by the addition of 2 reference curves: the -10% and -20% axial reference curves. Electrode positions over the face are named based on facial bony structures (N = nasion, Z = zygomatic prominence, M = mandible) and over the back of the head on posterior landmarks (I = inion, S = subinion, B = Base). Then, following the 10% incremental distance rule, we define additional electrode positions. Electrodes with nonstandard positions are clustered around the closest 10-10 electrode, deemed their cardinal point. RESULTS: The 256-electrode Geodesic Sensor Net mapped to 96 of the 120 extended 10-10 cardinal electrodes. CONCLUSIONS: Electrode position nomenclature that builds upon the international standard 10-10 system allows electroencephalographers to identify spatial areas of interest in HD-EEG relative to positions in routine use. A standard viewing montage for HD-EEG and its application with electrical source imaging boost efficiency when reviewing data and improve accuracy in recognizing epileptiform discharges. Additionally, our proposed system is not limited to a specific HD-EEG system, electrode count, or electrode layout.


Subject(s)
Electroencephalography/methods , Electroencephalography/standards , Terminology as Topic , Electrodes , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...