Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
3.
MedEdPublish (2016) ; 13: 288, 2023.
Article in English | MEDLINE | ID: mdl-38694949

ABSTRACT

Background: Nationally, underrepresented minorities represent a significant proportion of the first-generation student population. These students also tend to report lower levels of belongingness compared to their peers, which may impact their wellness and be an important factor in their academic success. This study aimed to explore whether status as a first-generation student was associated with belongingness amongst medical students. Methods: In 2019, a previously validated 16-item survey was used to examine potential disparities in belongingness amongst groups of first-generation medical students. Differences between groups were assessed using a Mann-Whitney U-test for each individual item and three composite groupings of items regarding social belonging, academic belonging, and institutional support. Results: First-generation to college and first-generation to graduate school students reported lower belongingness across most individual items as well as in all three composite groups. Conclusions: Given that peer relationships and institutional support play an important role in medical student belonging, these findings represent an opportunity to address the specific needs of individuals from underrepresented groups in medicine. Doing so can support the academic and professional success of first-generation students and help close the diversity gap in medicine.

4.
Article in English | MEDLINE | ID: mdl-33937907

ABSTRACT

Objective: Pregnancy requires a complex physiological adaptation of the maternal cardiovascular system, which is disrupted in women with pregnancies complicated by preeclampsia, putting them at higher risk of future cardiovascular events. The measurement of body movements in response to cardiac ejection via ballistocardiogram (BCG) can be used to assess cardiovascular hemodynamics noninvasively in women with preeclampsia. Methods: Using a previously validated, modified weighing scale for assessment of cardiovascular hemodynamics through measurement of BCG and electrocardiogram (ECG) signals, we collected serial measurements throughout pregnancy and postpartum and analyzed data in 30 women with preeclampsia and 23 normotensive controls. Using BCG and ECG signals, we extracted measures of cardiac output, J-wave amplitude × heart rate (J-amp × HR). Mixed-effect models with repeated measures were used to compare J-amp × HRs between groups at different time points in pregnancy and postpartum. Results: In normotensive controls, the J-amp × HR was significantly lower early postpartum (E-PP) compared with the second trimester (T2; p = 0.016) and third trimester (T3; p = 0.001). Women with preeclampsia had a significantly lower J-amp × HR compared with normotensive controls during the first trimester (T1; p = 0.026). In the preeclampsia group, there was a trend toward an increase in J-amp × HR from T1 to T2 and then a drop in J-amp × HR at T3 and further drop at E-PP. Conclusions: We observe cardiac hemodynamic changes consistent with those reported using well-validated tools. In pregnancies complicated by preeclampsia, the maximal force of contraction is lower, suggesting lower cardiac output and a trend in hemodynamics consistent with the hyperdynamic disease model of preeclampsia.

5.
Circ Heart Fail ; 11(1): e004313, 2018 01.
Article in English | MEDLINE | ID: mdl-29330154

ABSTRACT

BACKGROUND: Remote monitoring of patients with heart failure (HF) using wearable devices can allow patient-specific adjustments to treatments and thereby potentially reduce hospitalizations. We aimed to assess HF state using wearable measurements of electrical and mechanical aspects of cardiac function in the context of exercise. METHODS AND RESULTS: Patients with compensated (outpatient) and decompensated (hospitalized) HF were fitted with a wearable ECG and seismocardiogram sensing patch. Patients stood at rest for an initial recording, performed a 6-minute walk test, and then stood at rest for 5 minutes of recovery. The protocol was performed at the time of outpatient visit or at 2 time points (admission and discharge) during an HF hospitalization. To assess patient state, we devised a method based on comparing the similarity of the structure of seismocardiogram signals after exercise compared with rest using graph mining (graph similarity score). We found that graph similarity score can assess HF patient state and correlates to clinical improvement in 45 patients (13 decompensated, 32 compensated). A significant difference was found between the groups in the graph similarity score metric (44.4±4.9 [decompensated HF] versus 35.2±10.5 [compensated HF]; P<0.001). In the 6 decompensated patients with longitudinal data, we found a significant change in graph similarity score from admission (decompensated) to discharge (compensated; 44±4.1 [admitted] versus 35±3.9 [discharged]; P<0.05). CONCLUSIONS: Wearable technologies recording cardiac function and machine learning algorithms can assess compensated and decompensated HF states by analyzing cardiac response to submaximal exercise. These techniques can be tested in the future to track the clinical status of outpatients with HF and their response to pharmacological interventions.


Subject(s)
Algorithms , Electrocardiography/instrumentation , Heart Failure/physiopathology , Kinetocardiography/instrumentation , Machine Learning , Wearable Electronic Devices , Adult , Aged , Equipment Design , Exercise/physiology , Female , Humans , Male , Middle Aged
6.
Adv Skin Wound Care ; 30(10): 460-463, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28914680

ABSTRACT

OBJECTIVE: A recently described technique proposes a simple method to achieve permanent hemostasis of distal fingertip dermal avulsion injuries. It is simple to learn and easy to perform with readily available materials found in most emergency departments. However, long-term outcomes for patients treated with this technique have not yet been evaluated. A primary objective of the current article is to provide safety data for the technique using an off-label product indication. SETTING: Emergency department of Kaiser Permanente Medical Center, San Francisco, California. MATERIALS AND METHODS: Six patients were treated in the emergency department for fingertip dermal avulsion injuries using a tourniquet and tissue adhesive glue (Dermabond by Ethicon, Somerville, New Jersey). Patients were subsequently contacted to assess healing and satisfaction with cosmetic outcome through interview and photographs of their wounds at 9 months following the date of injury. RESULTS: All 6 patients were satisfied with the cosmetic outcome of treatment, and none received a diagnosis of serious complications. CONCLUSIONS: This series demonstrates cosmetic outcomes for injuries treated with the technique, highlights potential problems that may be perceived by patients during their clinical course, and creates the groundwork for a larger clinical study examining the use of the technique.


Subject(s)
Cyanoacrylates/therapeutic use , Finger Injuries/therapy , Soft Tissue Injuries/therapy , Tissue Adhesives/therapeutic use , Tourniquets , Adult , Aged , Anti-Bacterial Agents/therapeutic use , Debridement/methods , Emergency Service, Hospital , Female , Finger Injuries/diagnosis , Hemostatic Techniques/instrumentation , Humans , Injury Severity Score , Male , Middle Aged , Prognosis , Sampling Studies , Soft Tissue Injuries/diagnosis , Wound Healing/physiology
SELECTION OF CITATIONS
SEARCH DETAIL