Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ter Arkh ; 94(1): 135-144, 2022 Jan 15.
Article in Russian | MEDLINE | ID: mdl-36286929

ABSTRACT

Paraprotein is a laboratory biomarker of plasma cell tumors and other lymphoproliferative diseases. Its determination is necessary for diagnosing, monitoring and assessment of therapy effectiveness. The lecture presents the main methods of qualitative and quantative analysis of monoclonal proteins: gel electrophoresis, capillary electrophoresis, immunofixation and nephelometry features, possibilities and limitations are reviewed. The main sources of errors and artifacts during these studies are considered. Also the difficulties in the diagnosis and interpretation of the results of serum and urine tests are highlighted.


Subject(s)
Multiple Myeloma , Plasmacytoma , Humans , Paraproteins/analysis , Multiple Myeloma/diagnosis , Immunoelectrophoresis , Blood Protein Electrophoresis/methods
2.
Klin Lab Diagn ; 61(11): 781-786, 2016.
Article in Russian | MEDLINE | ID: mdl-31532951

ABSTRACT

The content of free light chains of immunoglobulins kappa and lambda and also ratio of their concentrations in blood serum are important diagnostic and prognostic markers in case of monoclonal gammopathy. The technique FreelightTM based on nephelometric detection of free light chains using polyclonal antibodies is one of common modes of detection of free light chains. The actual study was carried out with purpose of validating of national test-system for detection of level of free light chains in blood serum using technique of enzyme-linked immunosorbent assay. The samples of blood serum were taken from 89 healthy donors and 165 patients with monoclonal gammopathy. To detect the level of free light chains enzyme-linked immunosorbent assay testsystem "Polygnost" was used based on application of monoclonal a ntibodies. The number of analytical characteristics of reagents set was determined including limit of detection and range of linearity. The limit of detection of free light chains using enzymelinked immunosorbent assay test-system was two times lower than claimed by manufacturer of nephelometric set "FreelightTM". Hence, analytical characteristics of enzyme-linked immunosorbent assay set make it possible to detect the level of free light chains within range of standard values. The reference limits were established concerning concentration of free light chains kappa (3.25-15.81 mkg/ml), free light chains lambda (3.23-28.05 mkg/ml) and their ratio (0.3-1.9) in blood serum that factually matched the recommended intervals for "FreelightTM" set. In patients with monoclonal gammopathy the level of free light chains was reliably higher (p<0.01) as compared with control group of healthy donors. In case of paraproteinemia reliable alteration (p<0.01) of ratio free light chains kappa/free light chains lambda was observed in comparison with control group. The results of actual study testify that national enzyme-linked immunosorbent assay set has good analytical and diagnostic characteristics and it can be used in laboratory practice.

SELECTION OF CITATIONS
SEARCH DETAIL
...