Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Language
Publication year range
1.
Clinics (Sao Paulo) ; 66(6): 1003-7, 2011.
Article in English | MEDLINE | ID: mdl-21808866

ABSTRACT

AIM: This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. METHODS: A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, patients' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. RESULTS: There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of the lesions; for the wire-guided localization technique, 98%. Both localization time and operation time were significantly reduced with the ROLL technique (p = significant for all). The weight of the specimen was significantly lower in the ROLL group than in the wire-guided localization group (p = significant). The overall complication rate and pathological diagnosis were similar for both groups (p = non-significant for all). Clear margins were achieved in 91% of ROLL patients and in 53% of wire-guided localization patients, and the difference was significant. CONCLUSIONS: The present study indicated that the ROLL technique is as effective as wire-guided localization for the excision of non-palpable breast lesions. In addition, ROLL improved the outcomes by reducing localization and operation time, preventing healthy tissue excision and achieving clearer margins.


Subject(s)
Breast Neoplasms/diagnosis , Breast/pathology , Radiography, Interventional/methods , Adult , Biopsy/methods , Breast/diagnostic imaging , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Breast Neoplasms, Male/diagnosis , Breast Neoplasms, Male/pathology , Breast Neoplasms, Male/surgery , Chi-Square Distribution , Female , Fiducial Markers , Humans , Male , Middle Aged , Prospective Studies , Radionuclide Imaging , Radiopharmaceuticals , Statistics, Nonparametric , Technetium Tc 99m Aggregated Albumin , Time Factors , Treatment Outcome
2.
Clinics ; Clinics;66(6): 1003-1007, 2011. tab
Article in English | LILACS | ID: lil-594369

ABSTRACT

AIM: This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. METHODS: A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, patients' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. RESULTS: There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100 percent retrieval of the lesions; for the wire-guided localization technique, 98 percent. Both localization time and operation time were significantly reduced with the ROLL technique (p = significant for all). The weight of the specimen was significantly lower in the ROLL group than in the wire-guided localization group (p = significant). The overall complication rate and pathological diagnosis were similar for both groups (p = non-significant for all). Clear margins were achieved in 91 percent of ROLL patients and in 53 percent of wire-guided localization patients, and the difference was significant. CONCLUSIONS: The present study indicated that the ROLL technique is as effective as wire-guided localization for the excision of non-palpable breast lesions. In addition, ROLL improved the outcomes by reducing localization and operation time, preventing healthy tissue excision and achieving clearer margins.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Breast Neoplasms/diagnosis , Breast/pathology , Radiography, Interventional/methods , Biopsy/methods , Breast Neoplasms, Male/diagnosis , Breast Neoplasms, Male/pathology , Breast Neoplasms, Male/surgery , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Breast , Chi-Square Distribution , Fiducial Markers , Prospective Studies , Radiopharmaceuticals , Statistics, Nonparametric , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL