Am J Audiol ; 12(2): 137-45, 2003 Dec.
Article in English | MEDLINE | ID: mdl-14964329

ABSTRACT

The Synthetic Sentence Identification (SSI) test has been used extensively in investigations of reduced speech understanding skills in older adults. In this study the SSI test was altered by adding noise to the competing message and by administering practice lists and equivalent test lists, as well as versions of the test that have 4- and 12-s interstimulus intervals (ISIs), along with the standard 8-s ISI. The purpose was to determine the effect of these alterations on performance in a group of older adults with average pure-tone average 2 values less than 33 dB HL. Performance changed as a function of the ISI, with less rollover occurring for the 4-s ISI condition than the other 2 ISIs.


Subject(s)
Aging/physiology , Speech Perception/physiology , Aged , Analysis of Variance , Audiometry, Speech , Female , Humans , Male , Middle Aged , Severity of Illness Index , Time Factors