Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Publication year range
1.
Arch. argent. pediatr ; 121(5): e202202908, oct. 2023. tab
Article in English, Spanish | LILACS, BINACIS | ID: biblio-1509498

ABSTRACT

Introducción. La pandemia por COVID-19 ha puesto de manifiesto la necesidad de pruebas diagnósticas rápidas. La prueba de referencia es la reacción en cadena de la polimerasa en tiempo real (RT-PCR). Requiere un equipo y personal capacitado, y su resultado puede llevar un tiempo de espera prolongado. El sistema BD Veritor® es el método rápido cromatográfico utilizado para la detección del antígeno del coronavirus de tipo 2 del síndrome respiratorio agudo grave, en individuos sintomáticos. El objetivo primario del siguiente trabajo es evaluar sensibilidad y especificidad del test de antígeno (TA) comparadas con la RT-PCR en población pediátrica. Población y métodos. Estudio prospectivo, de prueba diagnóstica. Se incluyó a todo menor de 17 años en los primeros 5 días de inicio de síntomas, que consultó desde julio de 2021 hasta febrero de 2022. Se calculó un mínimo de 300 muestras para lograr una precisión de ± 8,76 % y de ± 3,68 % para sensibilidad y especificidad respectivamente. Se analizaron en paralelo las muestras por ambas metodologías. Resultados. De 316 muestras pareadas, 33 fueron positivas por ambos métodos; 6 fueron positivas solo por RT-PCR. La especificidad del TA fue del 100 %; la sensibilidad, del 84,6 %, con un valor predictivo positivo y negativo del 100 % y del 98 % respectivamente. Conclusiones. El TA demostró ser útil en el diagnóstico de pacientes pediátricos con COVID-19 en los primeros 5 días de inicio de síntomas, aunque aquellos con TA negativo y alta sospecha clínica deberían confirmar su resultado con la RT-PCR.


Introduction. The COVID-19 pandemic has brought to light the need for rapid diagnostic tests. The gold standard test is reverse transcription-polymerase chain reaction (RT-PCR). RT-PCR requires equipment and trained personnel, and results may take a long waiting time. The BD Veritor® System is a rapid chromatographic method used for the detection of severe acute respiratory syndrome coronavirus 2 antigen in symptomatic individuals. The primary objective of this study is to assess the sensitivity and specificity of the antigen test (AT) compared to the RT-PCR in the pediatric population. Population and methods. Prospective study with a diagnostic test. All children younger than 17 years in the first 5 days of symptom onset, who consulted between July 2021 and February 2022, were included. A minimum of 300 specimens was estimated to achieve an accuracy of ±8.76% and ±3.68% for sensitivity and specificity, respectively. Specimens were analyzed in parallel using both methodologies. Results. Of 316 paired samples, 33 were positive by both methods; 6 were positive only by RT-PCR. The specificity of the AT was 100%; sensitivity was 84.6%, with a positive and negative predictive value of 100% and 98%, respectively. Conclusions. The AT proved to be useful in the diagnosis of pediatric patients with COVID-19 in the first 5 days of symptom onset, although those with a negative AT and high clinical suspicion should confirm their result with a RT-PCR.


Subject(s)
Humans , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , COVID-19/diagnosis , Prospective Studies , Sensitivity and Specificity , Reverse Transcriptase Polymerase Chain Reaction , Reverse Transcription , Pandemics , COVID-19 Testing , SARS-CoV-2
2.
Medicina (B.Aires) ; 83(2): 185-189, jun. 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1448620

ABSTRACT

Abstract Asymptomatic infections with SARS-CoV-2 are associ ated with viral transmission and have a key role in the propagation of the pandemic. Understanding viral shed ding during asymptomatic infections is critical. Unfor tunately, data on asymptomatic SARS-CoV-2 infection in children is extremely limited. To determine the presence of viral viable shedding, we prospectively followed two healthy children of a family where both parents devel oped mild COVID-19 (April 2021). SARS-CoV-2 detection was made by RT-PCR and virus isolation by cell culture from saliva samples. Positive samples were sequenced to identify variants of SARS-CoV-2. Serum samples were evaluated to determine the presence of antibodies using a single enzyme-linked immunosorbent assay (ELISA, COVIDAR IgG). Both children were SARS-CoV-2 positive and asymptomatic. In addition, the virus grew in cell cul ture from saliva samples. Furthermore, one child showed viable SARS-CoV-2 for at least 17 days after the onset symptoms from his father. The recommended isolation period for asymptomatic contacts during the acquisition of data had been established for 10 days; however, this child remained with viable virus beyond that period. The positive samples from both children were consistent with B.1.1.28.1 lineage (Gamma). In both asymptomatic children, anti-Spike IgG was detected. Asymptomatic children may represent a source of infection that should not be underestimated during this pandemic.


Resumen Las infecciones asintomáticas por SARS-CoV-2 están asociadas a la transmisión viral y tienen un papel cla ve en la propagación de la pandemia. Comprender la excreción viral durante las infecciones asintomáticas es fundamental. Desafortunadamente, los datos sobre la infección asintomática por SARS-CoV-2 en niños son extremadamente limitados. Para determinar la presencia de excreción de virus viable, se siguió prospectivamente a dos niños sanos de una familia en la que ambos padres desarrollaron COVID-19 leve (abril 2021). La detección de SARS-CoV-2 se realizó por RT-PCR y el aislamiento del virus por cultivo celular a partir de muestras de saliva. Las muestras positivas se secuenciaron para identificar variantes de SARS-CoV-2. En las muestras de suero se determinó la presencia de anticuerpos utilizando un ensayo de ELISA (COVIDAR IgG). Ambos niños fueron positivos para SARS-CoV-2 y asintomáticos. Además, el virus creció en cultivos celulares a partir de muestras de saliva. Uno de los niños mantuvo SARS-CoV-2 via bles durante al menos 17 días después de la aparición de los síntomas de su padre. El período de aislamiento recomendado para contactos asintomáticos durante la adquisición de datos se había establecido en 10 días, sin embargo, este niño permaneció con virus viable más allá de ese período. Las muestras positivas de estos niños correspondieron al linaje B.1.1.28.1 (Gamma). En ambos niños asintomáticos se detectó anticuerpos IgG anti-Spike. Concluimos que los niños asintomáticos pueden representar una fuente de infección que no debe subestimarse durante esta pandemia.

3.
Medicina (B Aires) ; 83(2): 185-189, 2023.
Article in English | MEDLINE | ID: mdl-37094186

ABSTRACT

Asymptomatic infections with SARS-CoV-2 are associated with viral transmission and have a key role in the propagation of the pandemic. Understanding viral shedding during asymptomatic infections is critical. Unfortunately, data on asymptomatic SARS-CoV-2 infection in children is extremely limited. To determine the presence of viral viable shedding, we prospectively followed two healthy children of a family where both parents developed mild COVID-19 (April 2021). SARS-CoV-2 detection was made by RT-PCR and virus isolation by cell culture from saliva samples. Positive samples were sequenced to identify variants of SARS-CoV-2. Serum samples were evaluated to determine the presence of antibodies using a single enzyme-linked immunosorbent assay (ELISA, COVIDAR IgG). Both children were SARS-CoV-2 positive and asymptomatic. In addition, the virus grew in cell culture from saliva samples. Furthermore, one child showed viable SARS-CoV-2 for at least 17 days after the onset symptoms from his father. The recommended isolation period for asymptomatic contacts during the acquisition of data had been established for 10 days; however, this child remained with viable virus beyond that period. The positive samples from both children were consistent with B.1.1.28.1 lineage (Gamma). In both asymptomatic children, anti-Spike IgG was detected. Asymptomatic children may represent a source of infection that should not be underestimated during this pandemic.


Las infecciones asintomáticas por SARS-CoV-2 están asociadas a la transmisión viral y tienen un papel clave en la propagación de la pandemia. Comprender la excreción viral durante las infecciones asintomáticas es fundamental. Desafortunadamente, los datos sobre la infección asintomática por SARS-CoV-2 en niños son extremadamente limitados. Para determinar la presencia de excreción de virus viable, se siguió prospectivamente a dos niños sanos de una familia en la que ambos padres desarrollaron COVID-19 leve (abril 2021). La detección de SARS-CoV-2 se realizó por RT-PCR y el aislamiento del virus por cultivo celular a partir de muestras de saliva. Las muestras positivas se secuenciaron para identificar variantes de SARS-CoV-2. En las muestras de suero se determinó la presencia de anticuerpos utilizando un ensayo de ELISA (COVIDAR IgG). Ambos niños fueron positivos para SARS-CoV-2 y asintomáticos. Además, el virus creció en cultivos celulares a partir de muestras de saliva. Uno de los niños mantuvo SARS-CoV-2 viables durante al menos 17 días después de la aparición de los síntomas de su padre. El período de aislamiento recomendado para contactos asintomáticos durante la adquisición de datos se había establecido en 10 días, sin embargo, este niño permaneció con virus viable más allá de ese período. Las muestras positivas de estos niños correspondieron al linaje B.1.1.28.1 (Gamma). En ambos niños asintomáticos se detectó anticuerpos IgG anti-Spike. Concluimos que los niños asintomáticos pueden representar una fuente de infección que no debe subestimarse durante esta pandemia.


Subject(s)
COVID-19 , SARS-CoV-2 , Child , Humans , Asymptomatic Infections , Antibodies, Viral , Immunoglobulin G
4.
Arch Argent Pediatr ; 121(5): e202202908, 2023 10 01.
Article in English, Spanish | MEDLINE | ID: mdl-36883808

ABSTRACT

Introduction. The COVID-19 pandemic has brought to light the need for rapid diagnostic tests. The gold standard test is reverse transcription-polymerase chain reaction (RT-PCR). RT-PCR requires equipment and trained personnel, and results may take a long waiting time. The BD Veritor® System is a rapid chromatographic method used for the detection of severe acute respiratory syndrome coronavirus 2 antigen in symptomatic individuals. The primary objective of this study is to assess the sensitivity and specificity of the antigen test (AT) compared to the RT-PCR in the pediatric population. Population and methods. Prospective study with a diagnostic test. All children younger than 17 years in the first 5 days of symptom onset, who consulted between July 2021 and February 2022, were included. A minimum of 300 specimens was estimated to achieve an accuracy of ±8.76% and ±3.68% for sensitivity and specificity, respectively. Specimens were analyzed in parallel using both methodologies. Results. Of 316 paired samples, 33 were positive by both methods; 6 were positive only by RT-PCR. The specificity of the AT was 100%; sensitivity was 84.6%, with a positive and negative predictive value of 100% and 98%, respectively. Conclusions. The AT proved to be useful in the diagnosis of pediatric patients with COVID-19 in the first 5 days of symptom onset, although those with a negative AT and high clinical suspicion should confirm their result with a RT-PCR. Clinical trial registration: PRIISA.BA - Record number: 4912 - Date of registration: 07/07/2021.


Introducción. La pandemia por COVID-19 ha puesto de manifiesto la necesidad de pruebas diagnósticas rápidas. La prueba de referencia es la reacción en cadena de la polimerasa en tiempo real (RT-PCR). Requiere un equipo y personal capacitado, y su resultado puede llevar un tiempo de espera prolongado. El sistema BD Veritor® es el método rápido cromatográfico utilizado para la detección del antígeno del coronavirus de tipo 2 del síndrome respiratorio agudo grave, en individuos sintomáticos. El objetivo primario del siguiente trabajo es evaluar sensibilidad y especificidad del test de antígeno (TA) comparadas con la RT-PCR en población pediátrica. Población y métodos. Estudio prospectivo, de prueba diagnóstica. Se incluyó a todo menor de 17 años en los primeros 5 días de inicio de síntomas, que consultó desde julio de 2021 hasta febrero de 2022. Se calculó un mínimo de 300 muestras para lograr una precisión de ± 8,76 % y de ± 3,68 % para sensibilidad y especificidad respectivamente. Se analizaron en paralelo las muestras por ambas metodologías. Resultados. De 316 muestras pareadas, 33 fueron positivas por ambos métodos; 6 fueron positivas solo por RT-PCR. La especificidad del TA fue del 100 %; la sensibilidad, del 84,6 %, con un valor predictivo positivo y negativo del 100 % y del 98 % respectivamente. Conclusiones. El TA demostró ser útil en el diagnóstico de pacientes pediátricos con COVID-19 en los primeros 5 días de inicio de síntomas, aunque aquellos con TA negativo y alta sospecha clínica deberían confirmar su resultado con la RT-PCR. Registro de ensayos clínicos: PRIISA.BA ­ Número de registro: 4912 ­ Fecha de inscripción: 07/07/2021.


Subject(s)
COVID-19 , Humans , Child , COVID-19/diagnosis , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Pandemics , Prospective Studies , Reverse Transcription , Sensitivity and Specificity , COVID-19 Testing
5.
J Nephrol ; 36(3): 861-872, 2023 04.
Article in English | MEDLINE | ID: mdl-36152219

ABSTRACT

BACKGROUND AND AIM: Dialysis patients are a high-risk population and have a reduced immune response to vaccination against SARS-CoV-2. The aim of this study was to assess the humoral response to homologous Gam-COVID-Vac (Sputnik V) and heterologous Sputnik V/mRNA-1273 (Moderna) vaccination in dialysis patients. The vaccination scheme depended on dose availability and the prioritization of risk populations as established by the Argentine Ministry of Health. METHODS: Previous COVID-19 infection was determined in symptomatic patients. Binding IgG antibodies against the spike (S) receptor-binding domain (RBD) of SARS-CoV-2 (anti-S-RBD) concentration was assessed between 3 and 16 weeks after the boost dose. Anti-S-RBD antibodies were quantified using the Abbott Diagnostics SARS-CoV-2 IgG II Quant chemiluminescent microparticle immunoassay (CMIA) on an Architect i2000 SR and an Alinity I analyzer (Abbott Diagnostics, Abbott Park, Illinois, USA). To standardize the results to WHO binding antibody units (BAU), a correction factor for Abbott arbitrary units (AU) was applied where 1 BAU/mL equals 0.142 AU, as previously established by Abbott with the WHO international standard NIBSC 20-136. Following the manufacturer's recommendations, samples were considered reactive for anti-S-RBD when titers were above 50 AU/mL (7.2 BAU/mL). An 80% protective effect (PROT-80) against symptomatic SARS-CoV-2 infection was assumed when anti-S-RBD titers were 506 BAU/ml or higher. Charlson Comorbidity Index (CCI) score was classified as mild = 1-2, moderate = 3-4, and severe ≥ 5. Side effects were evaluated until day 7 by patients´ self-reported questionnaire. RESULTS: One hundred seven participants were enrolled [n = 84 homologous (SpV/SpV), nn 23 heterologous (SpV/Mod)]. Median (IQR) age was 64 (50-75) years old and 79 (73.8%) were male. Additionally, 19 (22.6%) of the SpV/SpV and 4 (17.4%) of the SpV/Mod group had a prior confirmed SARS-CoV-2 infection (p = 0.589). In the overall population, 103 patients reached seroconversion (96.3%). Anti-S-RBD IgG median titers (IQR) were higher in the heterologous [1222 (288-5680) BAU/mL] than in the homologous scheme [447 (100-1551) BAU/mL], p = 0.022. In a linear model adjusted for age, gender, days from first vaccination to boost dose and days from the boost dose to the anti-S-RBD IgG determination, previous SARS-COV-2 infection (B: 2062.2; CI95: 1231.8-2892.6; p < 0.001), and SpV/Mod vaccination scheme (B: 1294.6; CI95: 435.58-2147.6; p = 0.003) were independently associated with anti-S-RBD levels. Finally, a higher frequency of adverse effects was associated with the heterologous scheme, although they were well tolerated by all individuals. CONCLUSIONS: The present study provides evidence that the homologous SpV/SpV and heterologous SpV/Mod schemes showed good efficacy and safety in patients on chronic dialysis. These results could be useful for designing future vaccination strategies, especially aimed at this risk group.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Male , Middle Aged , Aged , Female , 2019-nCoV Vaccine mRNA-1273 , Renal Dialysis , Immunoglobulin G
6.
Front Public Health ; 10: 995249, 2022.
Article in English | MEDLINE | ID: mdl-36324442

ABSTRACT

Background: Management of the coronavirus disease 2019 (COVID-19) pandemic caused by a novel severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) requires rapid and simple methods to detect COVID-19 patients and identify potential infectors. This study aimed to evaluate the utility of a point-of-care (PoC) rapid antigen diagnostic test (Ag-RDT) in these settings. Patients and methods: Individuals who consecutively presented for SARS-CoV-2 testing at a tertiary care center in Buenos Aires, Argentina, underwent PoC Ag-RDT testing and real-time RT-PCR (qRT-PCR) on the same day during June 2021. Results: Of 584 included subjects, 108 (18.5%) were symptomatic for COVID-19 while the remaining presented for miscellaneous reasons unrelated to possible or confirmed contact with a SARS-CoV-2-infected individual. A positive Ag-RDT result was obtained in 26 (24.1%) symptomatic and 7 (1.5%) asymptomatic persons (p < 0.001), which was concordant with qRT-PCR in 105/108 [97.2%, Cohen's kappa coefficient (κ) = 0.927] symptomatic and 467/476 (98.1% κ = 0.563) asymptomatic participants, with a positive percentage agreement (PPA; 95% confidence interval) of 89.7% (71.5-97.3%) and 42.9% (18.8-70.4%), respectively. None of the 11 false-negative diagnoses showed a Ct-value ≤20. Considering only failures with a Ct-value below 31 as hypothetical infectivity threshold of 105 SARS-CoV-2 RNA copies/mL, concordance was observed in 98.1% (κ = 0.746) in the asymptomatic population, accounting for a PPA of 66.7% (30.9-91%). Conclusions: PoC Ag-RDT accurately detected active SARS-CoV-2 infection and showed acceptable diagnostic performance in asymptomatic persons potentially spreading infectious virus. Ag-RDT may therefore be useful to slow down or stop transmission by enabling adequate decisions on isolation at a public health level.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , COVID-19 Testing , Point-of-Care Systems , RNA, Viral/analysis , Sensitivity and Specificity
8.
Clin Microbiol Infect ; 28(10): 1382-1388, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35595128

ABSTRACT

OBJECTIVES: To compare the homologous prime-boost vaccination scheme of Gam-COVID-Vac (Sputnik V (SpV)) to its heterologous combination with mRNA-1273 (Moderna (Mod)) vaccine. METHODS: SARS-CoV-2 anti-spike (S)-receptor binding domain (RBD) IgG concentration was assessed three to seven weeks after complete vaccination. Reactogenicity was evaluated by declared side events and medical assistance required until day 7 post boost. RESULTS: Of 190 participants enrolled, 105 received homologous SpV/SpV and the remaining heterologous SpV/Mod vaccination scheme, respectively. Median (interquartile range (IQR)) age was 54 (37-63) years, 132 out of 190 (69.5%) were female, and 46 out of 190 (24.2%) individuals had a prior confirmed COVID-19. Anti-S-RBD IgG median (IQR) titers were significantly higher for SpV/Mod (2511 (1476-3992) binding antibody units (BAU)/mL) than for SpV/SpV (582 (209-1609) BAU/mL; p < 0.001] vaccination scheme. In a linear model adjusted for age, gender, time to the serological assay, and time between doses, SpV/Mod (4.154 (6.585-615.554); p < 0.001] and prior COVID (3.732 (8.641-202.010); p < 0.001) were independently associated with higher anti-S-RBD IgG values. A higher frequency of mild and moderate adverse effects was associated with the heterologous scheme (20 of 85 (23.5%) vs. 13 of 105 (12.4%); p = 0.043 and 27 of 85 (31.8%) vs. 14 of 105 (13.3%); p = 0.002), respectively, although it was well tolerated by all individuals and no medical assistance was required. DISCUSSION: The heterologous SpV/Mod combination against SARS-CoV-2 is well tolerated and significantly increases humoral immune response as compared to the homologous SpV/SpV immunization.


Subject(s)
2019-nCoV Vaccine mRNA-1273 , COVID-19 , 2019-nCoV Vaccine mRNA-1273/adverse effects , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines/adverse effects , Data Analysis , Female , Humans , Immunoglobulin G , Male , Middle Aged , SARS-CoV-2/genetics
SELECTION OF CITATIONS
SEARCH DETAIL
...