Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Arch Cardiovasc Dis ; 117(3): 186-194, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38326152

ABSTRACT

BACKGROUND: An implantable loop recorder is an effective tool for diagnosing unexplained syncope. However, after a first episode in non-high-risk patients, the usefulness of implantable loop recorder implantation remains unclear. AIMS: To analyse relevant risk factors for significant bradycardia in order to identify patients who do or do not benefit from implantable loop recorder implantation. Also, to study whether implantable loop recorder implantation with remote monitoring is associated with less recurrence of traumatic syncope. METHODS: This was a retrospective monocentric study including patients with implantable loop recorder implantation after unexplained syncope, using remote monitoring and iterative consultations. RESULTS: Two hundred and thirty-seven patients were implanted for unexplained syncope. Significant bradycardia occurred in 53 patients (22.4%): 23 (43.4%) caused by paroxysmal atrioventricular block and 30 (56.6%) caused by sinus node dysfunction, leading to permanent pacemaker implantation in 48 patients. Compared with younger patients, there was a 3.46-fold increase (95% confidence interval 1.92-6.23; P<0.0001) in the risk of significant bradycardia in patients aged≥60 years. Based on multivariable analysis, only "typical syncope" was associated with significant bradycardia occurrence (hazard ratio 3.14, 95% confidence interval 1.75-5.65; P=0.0001). There was no recurrence of significant bradycardia with traumatic complications among patients implanted for traumatic syncope. CONCLUSIONS: This study shows that: (1) implantable loop recorders identify more significant bradycardia in patients aged≥60 presenting with a first non-high-risk typical syncope, suggesting that an implantable loop recorder should be implanted after a first episode of unexplained syncope in such conditions; and (2) after traumatic syncope, implantable loop recorder implantation is safe, and is associated with little or no recurrence of traumatic syncope.


Subject(s)
Bradycardia , Syncope , Humans , Bradycardia/diagnosis , Bradycardia/therapy , Bradycardia/complications , Retrospective Studies , Syncope/diagnosis , Syncope/etiology , Syncope/therapy , Electrocardiography, Ambulatory/adverse effects , Risk Assessment , Electrodes, Implanted/adverse effects
2.
Front Cardiovasc Med ; 10: 1140216, 2023.
Article in English | MEDLINE | ID: mdl-37123476

ABSTRACT

Objectives: This study sought to assess the value of myocardial deformation using strain echocardiography in patients with mitral valve prolapse (MVP) and severe ventricular arrhythmia and to evaluate its impact on rhythmic risk stratification. Background: MVP is a common valvular affection with an overly benign course. Unpredictably, selected patients will present severe ventricular arrhythmia. Methods: Patients with MVP as the only cause of aborted SCD (MVP-aSCD: ventricular fibrillation and monomorphic and polymorphic ventricular tachycardia) with no other obvious reversible cause were identified. Nonconsecutive patients referred for the echocardiographic evaluation of MVP were enrolled as a control cohort and dichotomized according to the presence or absence of premature ventricular contractions (MVP-PVC or MVP-No PVC, respectively). All patients had a comprehensive strain assessment of mechanical dispersion (MD), postsystolic shortening, and postsystolic index (PSI). Results: A total of 260 patients were enrolled (20 MVP-aSCD, 54 MVP-PVC, and 186 MVP-No PVC). Deformation pattern discrepancies were observed with a higher PSI value in MVP-aSCD than that in MVP-PVC (4.6 ± 2.0 vs. 2.9 ± 3.7, p = 0.014) and a higher MD value than that in MVP-No PVC (46.0 ± 13.0 vs. 36.4 ± 10.8, p = 0.002). In addition, PSI and MD increased the prediction of severe ventricular arrhythmia on top of classical risk factors in MVP. Net reclassification improvement was 61% (p = 0.008) for PSI and 71% (p = 0.001) for MD. Conclusions: In MVP, myocardial deformation analysis with strain echocardiography identified specific contraction patterns with postsystolic shortening leading to increased values of PSI and MD, translating the importance of mitral valve-myocardial interactions in the arrhythmogenesis of severe ventricular arrhythmia. Strain echocardiography may provide important implications for rhythmic risk stratification in MVP.

3.
Clin Res Cardiol ; 112(8): 1129-1142, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37210700

ABSTRACT

BACKGROUND: Diagnosis of heart failure with preserved ejection fraction (HFpEF) remains challenging despite the use of scores/algorithms. This study intended to assess the diagnostic value of exercise lung ultrasound (LUS) for HFpEF diagnosis. METHODS: We studied two independent case-control studies of HFpEF patients and control subjects undergoing different exercise protocols: (i) submaximal exercise stress echocardiography (ESE) with LUS performed by expert cardiologists (N = 116, HFpEF = 65.5%), and (ii) maximal cycle ergometer test (CET) (N = 54, HFpEF = 50%) with LUS performed by unexperienced physicians shortly trained for the study. B-line kinetics (i.e. peak values and their changes from rest) were assessed. RESULTS: In the ESE cohort, the C-index (95% CI) of peak B-lines for HFpEF diagnosis was 0.985 (0.968-1.000), whereas the C-index of rest and exercise HFA-PEFF scores (i.e. including stress echo findings) were < 0.90 (CI 0.823-0.949), and that of H2FPEF score was < 0.70 (CI 0.558-0.764). The C-index increase of peak B-lines on top of the above-mentioned scores was significant (C-index increase > 0.090 and P-value < 0.001 for all). Similar results were observed for change B-lines. Peak B-lines > 5 (sensitivity = 93.4%, specificity = 97.5%) and change B-lines > 3 (sensitivity = 94.7%, specificity = 87.5%) were the best cutoffs for HFpEF diagnosis. Adding peak or change B-lines on top of HFpEF scores and BNP significantly improved diagnostic accuracy. Peak B-lines showed a good diagnostic accuracy in the LUS beginner-led CET cohort (C-index = 0.713, 0.588-0.838). CONCLUSIONS: Exercise LUS showed excellent diagnostic value for HFpEF diagnosis regardless of different exercise protocols/level of expertise, with additive diagnostic accuracy on top of available scores and natriuretic peptides.


Subject(s)
Heart Failure , Humans , Echocardiography, Stress/methods , Exercise Test , Heart Failure/diagnosis , Lung/diagnostic imaging , Stroke Volume , Ventricular Function, Left
4.
J Cardiovasc Electrophysiol ; 33(8): 1801-1809, 2022 08.
Article in English | MEDLINE | ID: mdl-35665562

ABSTRACT

We aim to describe the technical aspects of pace mapping (PM), as well as the two typical patterns of pacing correlation maps during ventricular tachycardia (VT) ablation. The first main pattern is focal, with a gradual and eccentric decrease of the QRS correlation from the area with the best PM correlation. This focal pattern may be associated with two clinical situations: (1) with some endocardial points showing a good correlation compared to VT morphology: true endocardial exit of VT or endocardial breakthrough of either an intramural or an epicardial circuit; (2) without any endocardial points showing a good correlation compared to VT morphology: the VT may originate from the other ventricle, but the presence of an intramural or an epicardial circuit should be considered in patients with a structural heart disease. The second pattern is the presence of PM points exhibiting a good correlation close to other PM points showing a poor correlation compared to VT morphology: this abrupt change in paced QRS morphology over a short distance indicates divergence of activation wavefronts between these sites and suggests the presence of a slow conduction channel: the VT isthmus.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Catheter Ablation/adverse effects , Electrocardiography , Endocardium/surgery , Heart Rate , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery
5.
J Cardiovasc Dev Dis ; 8(12)2021 Dec 13.
Article in English | MEDLINE | ID: mdl-34940538

ABSTRACT

Laser balloon (LB) has emerged as an interesting strategy for pulmonary vein isolation in paroxysmal atrial fibrillation (AF). A third-generation LB has recently been developed, allowing a continuous ablation set. We aimed to compare the results from our center's experience with second and third-generation LBs to a cohort of matched patients who had undergone radiofrequency ablation (RFA) with contact-force catheters. This retrospective monocenter case-control study included our first 50 LB paroxysmal AF ablations (26 second and 24 third-generation LB) and 50 RFA controls, matched on age, sex and left atrial dilation. The two groups had similar baseline parameters. LB procedures were significantly shorter than RFA (129 (110-160) vs. 160 (119-198) min, p = 0.007). During AF ablation, two major complications occurred in each group. At the one-year follow-up, AF recurrence was diagnosed in 7 (14%) of the LB group vs. 14 (28%) of the RFA group (p = 0.14). Moreover, we observed that third-generation LB procedures were associated with shorter laser applications (22 (19-29) vs. 69 (55-76) min, p < 0.001) and procedural durations (111 (100-128) vs. 151.5 (128.5-167) min, p < 0.001) compared to second-generation LB procedures. In the context of the major increase in the number of AF ablations, LB demonstrated consistent results in terms of clinical success, complications and also reduced procedure durations compared to RFA.

6.
J Clin Med ; 10(14)2021 Jul 08.
Article in English | MEDLINE | ID: mdl-34300203

ABSTRACT

BACKGROUND: In patients undergoing paroxysmal atrial fibrillation (PAF) ablation, pulmonary vein isolation (PVI) alone fails in maintaining sinus rhythm in up to one third of patients after a first catheter ablation. Epicardial adipose tissue (EAT), as an endocrine-active organ, could play a role in the recurrence of AF after catheter ablation. OBJECTIVE: To evaluate the predictive value of clinical, echocardiographic, biological parameters and epicardial fat density measured by computed tomography scan (CT-scan) on AF recurrence in PAF patients who underwent a first pulmonary vein isolation procedure using radiofrequency (RF). METHODS: This monocentric retrospective study included all patients undergoing first-time RF PAF ablation at the Nancy University Hospital between March 2015 and December 2018 with one-year follow-up. RESULTS: 389 patients were included, of whom 128 (32.9%) had AF recurrence at one-year follow-up. Neither total-EAT volume (88.6 ± 37.2 cm3 vs. 91.4 ± 40.5 cm3, p = 0.519), nor total-EAT radiodensity (-98.8 ± 4.1 HU vs. -98.8 ± 3.8 HU, p = 0.892) and left atrium-EAT radiodensity (-93.7 ± 4.3 HU vs. -93.4 ± 6.0 HU, p = 0.556) were significantly associated with AF recurrence after PAF ablation. In multivariate analysis, previous cavo-tricuspid isthmus (CTI) ablation, ablation procedure duration, BNP and triglyceride levels remained independently associated with AF recurrence after catheter ablation at 12-months follow-up. CONCLUSION: Contrary to persistent AF, EAT parameters are not associated with AF recurrence after paroxysmal AF ablation. Thus, the role of the metabolic atrial substrate in PAF pathophysiology appears less obvious than in persistent AF.

7.
Crit Care Med ; 48(4): e337, 2020 04.
Article in English | MEDLINE | ID: mdl-32205631
8.
Crit Care Med ; 47(10): e841-e844, 2019 10.
Article in English | MEDLINE | ID: mdl-31343476

ABSTRACT

OBJECTIVES: Lung ultrasound has shown increasing diagnostic value in many lung diseases and has become an efficient tool in the management of dyspnea. In the present case report, we describe a new ultrasound feature of potential interest. DATA SOURCES: Clinical observation of a patient. STUDY SELECTION: Case report. DATA EXTRACTION: Data were extracted from medical records, after obtaining consent from the patient's family. Illustrations were extracted from the imaging software and a video device. DATA SYNTHESIS: A 56-year-old man was admitted with pneumonia of adverse outcome. Lung ultrasound, a method increasingly considered as a bedside gold standard in critically ill patients due to its overwhelming advantages, was the only tool able to specify the lung injuries. We describe herein a distinctive sign unequivocally evoking a destructive process suggestive of pulmonary gangrene, a variant of the fractal sign combining a lung consolidation with an underlying heterogeneous free fluid. CONCLUSIONS: Lung ultrasound may help highlight pulmonary gangrene, a poorly-known disease, with this new ultrasonographic description. The next step will be to ascertain the relation between this new ultrasound feature and pulmonary gangrene and to assess how this bedside diagnosis could impact the prognosis of the disease.


Subject(s)
Lung Diseases/diagnostic imaging , Lung Diseases/pathology , Lung/diagnostic imaging , Lung/pathology , Gangrene/diagnostic imaging , Humans , Male , Middle Aged , Ultrasonography/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...