Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Nat Methods ; 16(11): 1105-1108, 2019 11.
Article in English | MEDLINE | ID: mdl-31527839

ABSTRACT

Light-sheet microscopy is an ideal technique for imaging large cleared samples; however, the community is still lacking instruments capable of producing volumetric images of centimeter-sized cleared samples with near-isotropic resolution within minutes. Here, we introduce the mesoscale selective plane-illumination microscopy initiative, an open-hardware project for building and operating a light-sheet microscope that addresses these challenges and is compatible with any type of cleared or expanded sample ( www.mesospim.org ).


Subject(s)
Microscopy, Fluorescence/instrumentation , Animals , Chick Embryo , Microscopy, Fluorescence/methods , Software
2.
PLoS One ; 12(6): e0179460, 2017.
Article in English | MEDLINE | ID: mdl-28640817

ABSTRACT

Genetically encoded calcium indicators (GECIs) enable imaging of in vivo brain cell activity with high sensitivity and specificity. In contrast to viral infection or in utero electroporation, indicator expression in transgenic reporter lines is induced noninvasively, reliably, and homogenously. Recently, Cre/tTA-dependent reporter mice were introduced, which provide high-level expression of green fluorescent GECIs in a cell-type-specific and inducible manner when crossed with Cre and tTA driver mice. Here, we generated and characterized the first red-shifted GECI reporter line of this type using R-CaMP1.07, a red fluorescent indicator that is efficiently two-photon excited above 1000 nm. By crossing the new R-CaMP1.07 reporter line to Cre lines driving layer-specific expression in neocortex we demonstrate its high fidelity for reporting action potential firing in vivo, long-term stability over months, and versatile use for functional imaging of excitatory neurons across all cortical layers, especially in the previously difficult to access layers 4 and 6.


Subject(s)
Calcium/metabolism , Green Fluorescent Proteins/genetics , Green Fluorescent Proteins/metabolism , Photons , Animals , Gene Expression , Mice , Mice, Transgenic , Molecular Imaging , Neocortex/diagnostic imaging , Neocortex/metabolism
3.
Neuron ; 85(5): 942-58, 2015 Mar 04.
Article in English | MEDLINE | ID: mdl-25741722

ABSTRACT

An increasingly powerful approach for studying brain circuits relies on targeting genetically encoded sensors and effectors to specific cell types. However, current approaches for this are still limited in functionality and specificity. Here we utilize several intersectional strategies to generate multiple transgenic mouse lines expressing high levels of novel genetic tools with high specificity. We developed driver and double reporter mouse lines and viral vectors using the Cre/Flp and Cre/Dre double recombinase systems and established a new, retargetable genomic locus, TIGRE, which allowed the generation of a large set of Cre/tTA-dependent reporter lines expressing fluorescent proteins, genetically encoded calcium, voltage, or glutamate indicators, and optogenetic effectors, all at substantially higher levels than before. High functionality was shown in example mouse lines for GCaMP6, YCX2.60, VSFP Butterfly 1.2, and Jaws. These novel transgenic lines greatly expand the ability to monitor and manipulate neuronal activities with increased specificity.


Subject(s)
Gene Targeting/methods , Integrases/genetics , Neurons/physiology , Optogenetics/methods , Animals , Hippocampus/chemistry , Hippocampus/physiology , Integrases/biosynthesis , Mice , Mice, Transgenic , Neurons/chemistry , Organ Culture Techniques , Visual Cortex/chemistry , Visual Cortex/physiology
SELECTION OF CITATIONS
SEARCH DETAIL