Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
World J Pediatr Congenit Heart Surg ; : 21501351241247503, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38780412

ABSTRACT

Background: Pediatric pulmonary vein stenosis (PVS) is often progressive and treatment-refractory, requiring multiple interventions. Hybrid pulmonary vein interventions (HPVIs), involving intraoperative balloon angioplasty or stent placement, leverage surgical access and customization to optimize patency while facilitating future transcatheter procedures. We review our experience with HPVI and explore potential applications of this collaborative approach. Methods: Retrospective chart review of all HPVI cases between 2009 to 2023. Results: Ten patients with primary (n = 5) or post-repair (n = 5) PVS underwent HPVI at median age of 12.7 months (range 6.6 months-9.5 years). Concurrent surgical PVS repair was performed in 7/10 cases. Hybrid pulmonary vein intervention was performed on 17 veins, 13 (76%) with prior surgical or transcatheter intervention(s). One patient underwent intraoperative balloon angioplasty of an existing stent. In total, 18 stents (9 bare metal [5-10 mm diameter], 9 drug eluting [3.5-5 mm diameter]) were placed in 16 veins. At first angiography (median 48 days [range 7 days-2.8 years] postoperatively), 8 of 16 (50%) HPVI-stented veins developed in-stent stenosis. Two patients died from progressive PVS early in the study, one prior to planned reintervention. Median time to first pulmonary vein reintervention was 86 days (10 days-2.8 years; 8/10 patients, 13/17 veins). At median survivor follow-up of 2.2 years (2.3 months-13.1 years), 1 of 11 surviving HPVI veins were completely occluded. Conclusions: Hybrid pulmonary vein intervention represents a viable adjunct to existing PVS therapies, with promising flexibility to address limitations of surgical and transcatheter modalities. Reintervention is anticipated, necessitating evaluation of long-term benefits and durability as utilization increases.

2.
Article in English | MEDLINE | ID: mdl-38199293

ABSTRACT

OBJECTIVE: To describe clinical, functional, surgical, and outcomes data in pediatric patients with a myocardial bridge (MB) evaluated and managed following a standardized approach. METHODS: Prospective observational study included patients evaluated in the Coronary Artery Anomalies Program. Anatomy was determined by computed tomography angiography, myocardial perfusion by stress perfusion imaging, and coronary hemodynamic assessment by cardiac catheterization. RESULTS: In total, 39 of 42 patients with a complete evaluation for MB were included (December 2012 to June 2022) at a median age of 14.1 years (interquartile range, 12.2-16.4). Sudden cardiac arrest occurred in 3 of 39 (8%), exertional symptoms in 14 (36%), and no/nonspecific symptoms in 7 (18%) patients. Exercise stress test was abnormal in 3 of 34 (9%), stress perfusion imaging in 8 of 34 (24%), and resting instantaneous wave-free ratio ≤0.89 or diastolic dobutamine fractional flow reserve ≤0.80 in 11 of 21 (52%) patients. As a result, 15 of 39 (38%) patients were determined to have hemodynamically significant MB, 1 of 15 patients started beta-blocker, and 14 of 15 were referred for surgery. Myotomy (n = 11) and coronary bypass (n = 1) were performed successfully, resulting in improved symptoms and stress testing results. One patient required pericardiocentesis postoperatively, and all were discharged without other complications. At median follow-up time of 2.9 (1.8-5.8) years, all (except 2 pending surgery) were doing well without exercise restriction. CONCLUSIONS: Pediatric patients with MB can present with myocardial ischemia and sudden cardiac arrest. Provocative stress test and intracoronary hemodynamic tests helped risk-stratify symptomatic patients with MB and concern for ischemia. Surgical repair was safe and effective in mitigating exertional symptoms and stress test results, allowing patients to return to exercise without restriction.

3.
J Invasive Cardiol ; 35(11)2023 Nov.
Article in English | MEDLINE | ID: mdl-37992333

ABSTRACT

BACKGROUND: The data on the use of Gore Cardioform Septal Occluder (GCA; W. L. Gore and Associates, Inc.) for atrial septal defect (ASD) with deficient rims is limited. METHODS: All patients evaluated by transesophageal echocardiogram (TEE) for ASD occlusion were included. TEE planes at 35°, 0°, and 90° were assessed for anterior-superior (AS) and posterior (P), anterior-inferior (AI) and posterior-superior (PS), as well as superior (S) and inferior (I) rims. ASD size >20 mm, and rims less than 5 mm were defined as large and deficient, respectively. We included patients who had a procedural failure along with the patients in whom the procedure was not attempted after echocardiogram in the unsuccessful group. RESULTS: In 148 patients, the median weight, age, and ASD size were 36 kg (range, 8-60 kg), 11.8 years (range, 1-60 years), and 14.2 ± 8.28 mm, respectively. One or more deficient rims were noted in 112 of 148 (75.7%): 99 (67%) AS, 36 (24%) P, 17 (11%) AI, 30 (20%) PS, 26 (18%) S, and 33 (22%) I. ASD closure was performed in 115 (78%) patients. The procedure was successful in 111 (96.5%) patients with procedural failure in 4 (3.4%) patients. Multiple deficient rims were associated with reduced procedural success (OR 0.36, 95% CI, 0.25-0.56). On multivariate analysis deficient P, PS, and I rims were associated with an unsuccessful group (P = .001, .046, and .005, respectively). Complications included 1 device embolization, 1 vascular injury, and 5 arrhythmias. CONCLUSIONS: Transcatheter closure of ASDs with deficient rims is feasible using GCA. Large ASDs with deficient P, PS, and I rims were associated with unsuccessful closure. Risk stratification and comprehensive evaluation of ASD rims is vital for the use of GCA.


Subject(s)
Heart Septal Defects, Atrial , Septal Occluder Device , Humans , Cardiac Catheterization , Heart Septal Defects, Atrial/diagnosis , Heart Septal Defects, Atrial/surgery , Echocardiography, Transesophageal , Echocardiography , Arrhythmias, Cardiac , Treatment Outcome
4.
Cardiol Young ; 33(12): 2678-2680, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37850452

ABSTRACT

Vascular access-related complications are an important consideration in patients undergoing cardiac catheterisation. Patients with CHD are increasingly undergoing percutaneous treatment for suitable procedures as an alternative, less invasive option to surgical intervention. As such, recognition and treatment of these complications are becoming increasingly important. We present a case of a patient with repaired Tetralogy of Fallot who developed a femoral arteriovenous fistula and femoral artery pseudoaneurysm arising from an accessory arterial branch following percutaneous Harmony valve implantation, both of which were treated endovascularly with placement of a stent.


Subject(s)
Aneurysm, False , Arteriovenous Fistula , Humans , Arteriovenous Fistula/diagnosis , Arteriovenous Fistula/etiology , Arteriovenous Fistula/surgery , Femoral Artery/surgery , Cardiac Catheterization/adverse effects , Iatrogenic Disease , Treatment Outcome
5.
JACC Case Rep ; 15: 101867, 2023 Jun 07.
Article in English | MEDLINE | ID: mdl-37283823

ABSTRACT

A toddler presented with hematemesis a few weeks after ingesting a penny. Workup revealed an esophageal lesion communicating with an aortic pseudoaneurysm in the setting of Actinomyces odontolyticus bacteremia. A. odontolytica is an oropharyngeal bacteria known to cause fistulas when introduced into tissue planes. (Level of Difficulty: Intermediate.).

6.
Pediatr Cardiol ; 2023 May 21.
Article in English | MEDLINE | ID: mdl-37210685

ABSTRACT

Single ventricle patients eligible for Fontan completion undergo pre-Fontan catheterization for hemodynamic and anatomic assessment prior to surgery. Cardiac magnetic resonance imaging may be used to evaluate pre-Fontan anatomy, physiology, and collateral burden. We describe our center's outcomes in patients undergoing pre-Fontan catheterization combined with cardiac magnetic resonance imaging. A retrospective review of patients undergoing pre-Fontan catheterization from 10/2018 to 04/2022 at Texas Children's Hospital was performed. Patients were divided into 2 groups: combined cardiac magnetic resonance imaging and catheterization (combined group) and those who underwent catheterization only (catheterization only group). There were 37 patients in the combined group and 40 in the catheterization only group. Both groups were similar in age and weight. Patients undergoing combined procedures received less contrast, and experienced less in-lab time, fluoroscopy time and catheterization procedure time. Median radiation exposure was lower in the combined procedure group but was not statistically significant. Intubation and total anesthesia times were higher in the combined procedure group. Patients undergoing a combined procedure were less likely to have collateral occlusion performed than in the catheterization only group. Bypass time, intensive care unit length of stay, and chest tube duration were similar in both groups at the time of Fontan completion. Combined pre-Fontan assessment decreases catheterization procedure and fluoroscopy time associated with cardiac catheterization at the expense of longer anesthetic times, and results in similar Fontan outcomes compared to when cardiac catheterization alone is utilized.

7.
Cardiol Young ; 33(12): 2621-2627, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37092668

ABSTRACT

BACKGROUND: Fontan baffle punctures and creation of Fontan fenestration for cardiac catheterisation procedures remain challenging especially due to the heavy calcification of prosthetic material and complex anatomy. OBJECTIVES: We sought to evaluate our experience using radiofrequency current via surgical electrocautery needle for Fontan baffle puncture to facilitate diagnostic, electrophysiology, and interventional procedures. METHODS: A retrospective chart review of all Fontan patients (pts) who underwent Fontan baffle puncture using radiofrequency energy via surgical electrocautery from three centres were performed from January 2011 to July 2021. RESULTS: A total of 19 pts underwent 22 successful Fontan baffle puncture. The median age and weight were 17 (3-36 years) and 55 (14-88) kg, respectively. The procedural indications for Fontan fenestration creation included: diagnostic study (n = 1), atrial septostomy and stenting (n = 1), electrophysiology study and ablation procedures (n = 8), Fontan baffle stenting for Fontan failure including protein-losing enteropathy (n = 7), and occlusion of veno-venous collaterals (n = 2) for cyanosis. The type of Fontan baffles included: extra-cardiac conduits (n = 12), lateral tunnel (n = 5), classic atrio-pulmonary connection (n = 1), and intra-cardiac baffle (n = 1). A Fontan baffle puncture was initially attempted using traditional method in 6 pts and Baylis radiofrequency trans-septal system in 2 pts unsuccessfully. In all pts, Fontan baffle puncture using radiofrequency energy via electrocautery needle was successful. The radiofrequency energy utilised was (10-50 W) and required 1-5 attempts for 2-5 seconds. There were no vascular or neurological complications. CONCLUSIONS: Radiofrequency current delivery using surgical electrocautery facilitates Fontan baffle puncture in patients with complex and calcified Fontan baffles for diagnostic, interventional, and electrophysiology procedures.


Subject(s)
Fontan Procedure , Heart Defects, Congenital , Humans , Heart Defects, Congenital/complications , Retrospective Studies , Heart , Cardiac Catheterization , Electrocoagulation , Treatment Outcome
8.
Cardiol Young ; 33(11): 2342-2349, 2023 Nov.
Article in English | MEDLINE | ID: mdl-36861393

ABSTRACT

BACKGROUND: Anomalous aortic origin of the left coronary artery with intraseptal course is a rare coronary anomaly associated with an increased risk of myocardial ischaemia. The role and techniques for surgical intervention are evolving, with numerous novel surgical techniques for this challenging anatomy reported in the last 5 years. We report our single-centre experience with surgical repair of intraseptal anomalous left coronary artery in the paediatric population, including clinical presentation, evaluation, and short- to mid-term outcomes. METHODS: All patients with coronary anomalies presenting to our institution undergo standardised clinical evaluation. Five patients aged 4 to 17 years underwent surgical intervention for intraseptal anomalous aortic origin of the left coronary artery between 2012 and 2022. Surgical techniques included coronary artery bypass grafting (n = 1), direct reimplantation with limited supra-arterial myotomy via right ventriculotomy (n = 1), and transconal supra-arterial myotomy with right ventricular outflow tract patch reconstruction (n = 3). RESULTS: All patients had evidence of haemodynamically significant coronary compression, and three had evidence of inducible myocardial ischaemia pre-operatively. There were no deaths or major complications. Median follow-up was 6.1 months (range 3.1-33.4 months). Patients who underwent supra-arterial myotomy (with or without reimplantation) had improved coronary flow and perfusion based on stress imaging and catheterisation data. CONCLUSIONS: Surgical approaches to intraseptal anomalous left coronary artery with evidence of myocardial ischaemia continue to evolve, with new techniques demonstrating promising improvement in coronary perfusion. Further studies are warranted to determine long-term outcomes and refine indications for repair.


Subject(s)
Anomalous Left Coronary Artery , Coronary Artery Disease , Coronary Vessel Anomalies , Myocardial Ischemia , Child , Humans , Anomalous Left Coronary Artery/complications , Coronary Vessel Anomalies/diagnosis , Coronary Vessel Anomalies/surgery , Coronary Vessel Anomalies/complications , Myocardial Ischemia/complications , Myocardial Ischemia/surgery , Coronary Artery Disease/complications , Aorta/abnormalities , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Retrospective Studies , Treatment Outcome
9.
Cardiol Young ; 33(9): 1746-1749, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36951042

ABSTRACT

Coronary artery anomalies may induce myocardial ischaemia and sudden cardiac death when associated with areas of compression or stenosis. We present a case of transection and reimplantation of an anomalous interarterial right coronary artery arising from a single left main coronary artery. The 18-year-old collegiate athlete had exertional chest pain and haemodynamically significant compromise to coronary blood flow.


Subject(s)
Coronary Artery Disease , Coronary Vessel Anomalies , Humans , Adolescent , Coronary Vessel Anomalies/diagnosis , Coronary Vessel Anomalies/surgery , Coronary Vessel Anomalies/complications , Coronary Artery Disease/complications , Replantation , Athletes
10.
J Thorac Cardiovasc Surg ; 166(3): 916-925.e6, 2023 09.
Article in English | MEDLINE | ID: mdl-36828672

ABSTRACT

OBJECTIVE: Neonates with tetralogy of Fallot and pulmonary atresia (TOF/PA) but no major aorta-pulmonary collaterals are dependent on the arterial duct for pulmonary blood flow and require early intervention, either by primary (PR) or staged repair (SR) with initial palliation (IP) followed by complete repair (CR). The optimal approach has not been established. METHODS: Neonates with TOF/PA who underwent PR or SR were retrospectively reviewed from the Congenital Cardiac Research Collaborative. Outcomes were compared between PR and SR (IP + CR) strategies. Propensity scoring was used to adjust for baseline differences. The primary outcome was mortality. Secondary outcomes included complications, length of stay, cardiopulmonary bypass and anesthesia times, reintervention (RI), and pulmonary artery (PA) growth. RESULTS: Of 282 neonates, 106 underwent PR and 176 underwent SR (IP: 144 surgical, 32 transcatheter). Patients who underwent SR were more likely to have DiGeorge syndrome and greater rates of mechanical ventilation before the initial intervention. Mortality was not significantly different. Duration of mechanical ventilation, inotrope use, and complication rates were similar. Cumulative length of stay, cardiopulmonary bypass, and anesthesia times favored PR (P ≤ .001). Early RI was more common in patients who underwent SR (rate ratio, 1.42; P = .003) but was similar after CR (P = .837). Conduit size at the time of CR was larger with SR. Right PA growth was greater with PR. CONCLUSIONS: In neonates with TOF/PA, SR is more common in greater-risk patients. Accounting for this, SR and PR strategies have similar mortality. Perioperative morbidities, RI, and right PA growth generally favor PR, whereas SR allows for larger initial conduit implantation.


Subject(s)
DiGeorge Syndrome , Pulmonary Atresia , Tetralogy of Fallot , Infant, Newborn , Humans , Infant , Pulmonary Atresia/surgery , Pulmonary Atresia/complications , Retrospective Studies , Aorta , Pulmonary Artery/surgery , Treatment Outcome
11.
Curr Probl Cardiol ; 48(2): 101463, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36261100

ABSTRACT

Pulmonary vein atresia (PVA) may lead to pulmonary hypertension, cardiac failure, and death. Transcatheter or surgical treatments have rarely been offered to this population because of perceived poor outcomes. We describe single center outcomes of transcatheter management of PVA. Retrospective chart review of PVA patients who underwent cardiac catheterization at a single tertiary center. Sixty patients underwent catheterization for evaluation of PVA from 1995 to 2019. The age at the initial catheterization was 1.6 (0.7, 5.97) years. Two thirds of PVA patients had associated congenital heart disease (n=40). PVA recanalization was attempted in 34 patients, successful in 23/34 (68%) of the initial attempts. 3/23 (13%) underwent balloon angioplasty alone, and 20/23 (87%) received drug-eluting stents, with no procedural mortalities. 22/23 patients had transcatheter reinterventions during an interval of 2.1 (0.3, 5.1) years. Right ventricular systolic to aortic systolic pressure ratio (in biventricular patients) at the index catheterization was 0.45 (0.34, 0.68) in survivors versus 0.69 (0.54, 0.83) in those who died; P = 0.012 (n=45). The baseline right ventricular or pulmonary artery systolic to aortic systolic pressure ratio of ≥0.54 at the initial catheterization was predictive of mortality. We hereby demonstrate that transcatheter recanalization of PVA with placement of drug-eluting stents can be performed safely with acceptable success rate. With appropriate use of re-interventions for restenosis as indicated, PVA can be successfully palliated with good long-term patency and distal growth of the affected veins. Pulmonary hypertension is a risk factor for mortality in patients with PVA and biventricular circulation. Percutaneous recanalization of PVA is safe and feasible, and with placement of drug-eluting stents, carries a high acute success rate and results in growth of the distal pulmonary veins. However, close vigilance and reinterventions are required due to restenosis.


Subject(s)
Heart Defects, Congenital , Hypertension, Pulmonary , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Follow-Up Studies , Retrospective Studies , Feasibility Studies , Treatment Outcome , Heart Defects, Congenital/surgery , Cardiac Catheterization , Constriction, Pathologic , Stents
12.
J Healthc Qual ; 45(2): 59-68, 2023.
Article in English | MEDLINE | ID: mdl-36041070

ABSTRACT

INTRODUCTION: Pediatric sepsis is a leading cause of death among children. Electronic alert systems may improve early recognition but do not consistently result in timely interventions given the multitude of clinical presentations, lack of treatment consensus, standardized order sets, and inadequate interdisciplinary team-based communication. We conducted a quality improvement project to improve timely critical treatment of patients at risk for infection-related decompensation (IRD) through team-based communication and standardized treatment workflow. METHODS: We evaluated children at risk for IRD as evidenced by the activation of an electronic alert system (Children at High Risk Alert Tool [CAHR-AT]) in the emergency department. Outcomes were assessed after multiple improvements including CAHR-AT implementation, clinical coassessment, visual cues for situational awareness, huddles, and standardized order sets. RESULTS: With visual cue activation, initial huddle compliance increased from 7.8% to 65.3% ( p < .001). Children receiving antibiotics by 3 hours postactivation increased from 37.9% pre-CAHR-AT to 50.7% posthuddle implementation ( p < .0001); patients who received a fluid bolus by 3 hours post-CAHR activation increased from 49.0% to 55.2% ( p = .001). CONCLUSIONS: Implementing a well-validated electronic alert tool did not improve quality measures of timely treatment for high-risk patients until combined with team-based communication, standardized reassessment, and treatment workflow.


Subject(s)
Sepsis , Humans , Child , Sepsis/therapy , Patients , Interdisciplinary Communication , Communication , Emergency Service, Hospital , Decision Making
14.
J Am Coll Cardiol ; 79(12): 1170-1180, 2022 03 29.
Article in English | MEDLINE | ID: mdl-35331412

ABSTRACT

BACKGROUND: Recent data have demonstrated that overall mortality and adverse events are not significantly different for primary repair (PR) and staged repair (SR) approaches to management of neonates with symptomatic tetralogy of Fallot (sTOF). Cost data can be used to compare the relative value (cost for similar outcomes) of these approaches and are a potentially more sensitive measure of morbidity. OBJECTIVES: This study sought to compare the economic costs associated with PR and SR in neonates with sTOF. METHODS: Data from a multicenter retrospective cohort study of neonates with sTOF were merged with administrative data to compare total costs and cost per day alive over the first 18 months of life in a propensity score-adjusted analysis. A secondary analysis evaluated differences in department-level costs. RESULTS: In total, 324 subjects from 6 centers from January 2011 to November 2017 were studied (40% PR). The 18-month cumulative mortality (P = 0.18), procedural complications (P = 0.10), hospital complications (P = 0.94), and reinterventions (P = 0.22) did not differ between PR and SR. Total 18-month costs for PR (median $179,494 [IQR: $121,760-$310,721]) were less than for SR (median: $222,799 [IQR: $167,581-$327,113]) (P < 0.001). Cost per day alive (P = 0.005) and department-level costs were also all lower for PR. In propensity score-adjusted analyses, PR was associated with lower total cost (cost ratio: 0.73; P < 0.001) and lower department-level costs. CONCLUSIONS: In this multicenter study of neonates with sTOF, PR was associated with lower costs. Given similar overall mortality between treatment strategies, this finding suggests that PR provides superior value.


Subject(s)
Cardiac Surgical Procedures , Tetralogy of Fallot , Cardiac Surgical Procedures/adverse effects , Humans , Infant, Newborn , Retrospective Studies , Tetralogy of Fallot/surgery , Treatment Outcome
15.
Pediatr Qual Saf ; 7(5): e601, 2022.
Article in English | MEDLINE | ID: mdl-38584957

ABSTRACT

Introduction: Patient transfers pose a potential risk during hospitalizations. Structured communication practices are necessary to ensure effective handoffs, but occur amidst competing priorities and constraints. We sought to design and implement a multidisciplinary process to enhance communication between pediatric cardiovascular intensive care unit and cardiology floor teams with a comprehensive approach evaluating efficiency, safety, and culture. Methods: We conducted a prospective quality improvement study to enact a bed-availability triggered bedside handoff process. The primary aim was to reduce the time between handoff and unit transfer. Secondary metrics captured the impact on safety (reported safety events, overnight transfers, bounce backs, and I-PASS utilization), efficiency (transfer latency, unnecessary patient handoffs, and cumulative time providers were engaged in handoffs), and culture (team members perceptions of satisfaction, collaboration, and handoff efficiency via survey data). Results: Eighty-two preimplementation surveys, 26 stakeholder interviews, and 95 transfers were completed during the preintervention period. During the postintervention period, 145 handoffs were audited. We observed significant reductions in transfer latency, unnecessary handoffs, and cumulative provider handoff time. Overnight transfers decreased, and no negative impact was observed in reported safety events or bouncebacks. Survey results showed a positive impact on collaboration, efficiency, and satisfaction among team members. Conclusions: Developing safer handoff practices require a collaborative, structured, and stepwise approach. Advances are attainable in high-volume centers, and comprehensive measurement of change is necessary to ensure a positive impact on the overall patient and provider environment.

17.
J Invasive Cardiol ; 33(6): E425-E430, 2021 06.
Article in English | MEDLINE | ID: mdl-33893794

ABSTRACT

OBJECTIVES: To describe a deployment technique of the Gore Cardioform atrial septal defect (ASD) occluder (W.L. Gore and Associates) for large secundum ASDs and ASDs with challenging anatomy. BACKGROUND: The Gore Cardioform ASD occluder has recently been approved for closure of secundum ASDs; however, there are limitations to its delivery system. METHODS: A retrospective study was conducted on the use of a Mullins sheath (Cook Medical) to facilitate Gore Cardioform ASD occluder delivery for secundum ASD closure in the cardiac catheterization laboratory from June, 2017 to December, 2019 at Texas Children's Hospital/Baylor College of Medicine. RESULTS: Out of 98 patients who underwent an attempt at ASD closure using the Gore Cardioform ASD occluder, a Mullins sheath was used in 52 patients (median age, 8 years [interquartile range, 4-13 years] and weight 27.2 kg [interquartile range, 17.9-51.2 kg]), with a successful implant in 46/52 patients (88%). The Mullins sheath was primarily used to deliver large devices (>32 mm) in 38/46 successful implants (83%). There were 2 major adverse events (atrial fibrillation requiring cardioversion). At a median follow-up of 43 days (interquartile range, 1-374 days), no patient had more than a mild residual shunt. The ASD size, maximum sheath size, and device size were larger in patients in whom the Mullins sheath was used as compared with those patients in whom a Mullins sheath was not used. CONCLUSIONS: The Mullins sheath-facilitated delivery of the Gore Cardioform ASD occluder device may be a useful adjunct technique for closure of large secundum ASDs and secundum ASDs with challenging anatomy.


Subject(s)
Atrial Fibrillation , Heart Septal Defects, Atrial , Septal Occluder Device , Cardiac Catheterization , Child , Heart Septal Defects, Atrial/diagnosis , Heart Septal Defects, Atrial/surgery , Humans , Prosthesis Design , Retrospective Studies , Time Factors , Treatment Outcome
18.
J Am Coll Cardiol ; 77(8): 1093-1106, 2021 03 02.
Article in English | MEDLINE | ID: mdl-33632484

ABSTRACT

BACKGROUND: Neonates with tetralogy of Fallot and symptomatic cyanosis (sTOF) require early intervention. OBJECTIVES: This study sought to perform a balanced multicenter comparison of staged repair (SR) (initial palliation [IP] and subsequent complete repair [CR]) versus primary repair (PR) treatment strategies. METHODS: Consecutive neonates with sTOF who underwent IP or PR at ≤30 days of age from 2005 to 2017 were retrospectively reviewed from the Congenital Cardiac Research Collaborative. The primary outcome was death. Secondary outcomes included component (IP, CR, PR) and cumulative (SR): hospital and intensive care unit lengths of stay; durations of cardiopulmonary bypass, anesthesia, ventilation, and inotrope use; and complication and reintervention rates. Outcomes were compared using propensity score adjustment. RESULTS: The cohort consisted of 342 patients who underwent SR (IP: surgical, n = 256; transcatheter, n = 86) and 230 patients who underwent PR. Pre-procedural ventilation, prematurity, DiGeorge syndrome, and pulmonary atresia were more common in the SR group (p ≤0.01). The observed risk of death was not different between the groups (10.2% vs 7.4%; p = 0.25) at median 4.3 years. After adjustment, the hazard of death remained similar between groups (hazard ratio: 0.82; 95% confidence interval: 0.49 to 1.38; p = 0.456), but it favored SR during early follow-up (<4 months; p = 0.041). Secondary outcomes favored the SR group in component analysis, whereas they largely favored PR in cumulative analysis. Reintervention risk was higher in the SR group (p = 0.002). CONCLUSIONS: In this multicenter comparison of SR or PR for management of neonates with sTOF, adjusted for patient-related factors, early mortality and neonatal morbidity were lower in the SR group, but cumulative morbidity and reinterventions favored the PR group, findings suggesting potential benefits to each strategy.


Subject(s)
Tetralogy of Fallot/surgery , Cohort Studies , Cyanosis/etiology , Cyanosis/surgery , Heart Transplantation/statistics & numerical data , Humans , Infant, Newborn , Intensive Care Units, Neonatal , Length of Stay/statistics & numerical data , Reoperation/statistics & numerical data , Respiration, Artificial/statistics & numerical data , Retrospective Studies , Tetralogy of Fallot/mortality , Time Factors
19.
Curr Cardiol Rep ; 22(3): 14, 2020 01 29.
Article in English | MEDLINE | ID: mdl-31997085

ABSTRACT

PURPOSE OF REVIEW: To review the most recent literature on pediatric transcatheter ductal intervention including ductus arteriosus occlusion and stenting. RECENT FINDINGS: With the development and FDA approval of smaller ductal devices, including most recently the Amplatzer Piccolo Occluder (Abbott, Abbott Park, IL), transcatheter ductus arteriosus device closure is now being safely performed in premature infants and patients < 6 kg using a transvenous approach. In patients with ductus-dependent pulmonary blood flow, ductal stenting with pre-mounted coronary artery stents has been shown to be an acceptable alternative to the surgically placed Blalock-Taussig shunt. Centers with experience in ductal stenting have demonstrated success, even with the tortuous ductus. Innovation in transcatheter device technology and procedural practices have allowed for significant advances. Transcatheter ductal device closure is a reasonable alternative to surgical ligation even in premature, low-birthweight infants. Ductal stenting is also an accepted alternative to the modified Blalock-Taussig shunt. We anticipate continued advancement and procedural refinement over the next several years.


Subject(s)
Cardiac Catheterization/instrumentation , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus/physiopathology , Palliative Care/methods , Stents , Blalock-Taussig Procedure/adverse effects , Cardiac Catheterization/adverse effects , Child , Ductus Arteriosus, Patent/physiopathology , Humans , Infant , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...