Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Interact Cardiovasc Thorac Surg ; 27(4): 505-511, 2018 10 01.
Article in English | MEDLINE | ID: mdl-29659843

ABSTRACT

OBJECTIVES: Minimally invasive aortic valve replacement has proven its value over the last decade by its significant advancement and reduction in mortality, morbidity and admission time. However, minimally invasive aortic valve replacement is associated with some on-site difficulties such as limited aortic annulus exposure. Currently, computed tomography scans are used to evaluate the anatomical relationship among the intercostal spaces, ascending aorta and aortic valve prior to surgery. We hypothesized that quantitative measurements of access distance and access angle are associated with outcome and access difficulty. METHODS: We introduce a novel minimally invasive aortic valve replacement planning prototype that allows automatic measurements of access angle, access distance and aortic annulus dimensions. The prototype visualizes these measurements on the chest cage as ISO contours. The association of these measures with outcome parameters such as extracorporeal circulation time, aortic cross-clamping time and access difficulty score was assessed. We included 14 patients who received a new valve by ministernotomy. RESULTS: The mean access angle was 40.3 ± 5.1°. It was strongly associated with aortic cross-clamping time (Pearson correlation coefficient = 0.60, P = 0.02) and access difficulty score (Spearman's rank correlation coefficient = 0.57, P = 0.03). Access angles were significantly different between easy and difficult access groups (P = 0.03). There was no significant association between access distance and outcome parameters. CONCLUSIONS: Access angle is strongly associated with procedure complexity. The automated presentation of this measure suggests added value of the prototype in clinical practice.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Imaging, Three-Dimensional , Minimally Invasive Surgical Procedures/methods , Multidetector Computed Tomography/methods , Adult , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Female , Humans , Male , Middle Aged , Predictive Value of Tests
2.
PLoS One ; 12(9): e0184133, 2017.
Article in English | MEDLINE | ID: mdl-28886071

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established treatment for patients with severe aortic valve stenosis. This procedure requires pre-operative planning by assessment of aortic dimensions on CT Angiography (CTA). It is well-known that the aortic root dimensions vary over the heart cycle. However, sizing is commonly performed at either mid-systole or end-diastole only, which has resulted in an inadequate understanding of its full dynamic behavior. STUDY GOAL: We studied the variation in annulus measurements during the cardiac cycle and determined if this variation is dependent on the amount of calcification at the annulus. METHODS: We measured and compared aortic root annular dimensions and calcium volume in CTA acquisitions at 10 cardiac cycle phases in 51 aortic stenosis patients. Sub-group analysis was performed based on the volume of calcium by splitting the population into mildly and severely calcified valves subgroups. RESULTS: For most annulus measurements, the largest differences were found between 10% and 70 to 80% cardiac cycle phases. Mean difference (±standard deviation) in annular minimum diameter, maximum diameter, area, and aspect ratio between mid-systole and end-diastole phases were 1.0 ± 0.29 mm (p = 0.065), 0.30 ± 0.24 mm (p = 0.7), 24.1 ± 7.6 mm2 (p < 0.001), and 0.041 ± 0.012 (p = 0.039) respectively. Calcium volume measurements varied strongly during the cardiac cycle. The dynamic annulus area was behaving differently between mildly and severely calcified subgroups (p = 0.02). Furthermore, patients with severe aortic calcification were associated with larger annulus diameters. CONCLUSION: There is a significant variation of annulus area and calcium volume measurement during the cardiac cycle. In our measurements, only the dynamic variation of the annulus area is dependent on the severity of the aortic calcification. For TAVI candidates, the annulus area is significantly larger in mid-systole compared to end-diastole.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/pathology , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Computed Tomography Angiography , Four-Dimensional Computed Tomography , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Calcinosis , Computed Tomography Angiography/methods , Female , Four-Dimensional Computed Tomography/methods , Humans , Male , Severity of Illness Index , Transcatheter Aortic Valve Replacement/methods
3.
Med Eng Phys ; 39: 123-128, 2017 01.
Article in English | MEDLINE | ID: mdl-27913175

ABSTRACT

Minimally invasive aortic valve replacement (mini-AVR) procedures are a valuable alternative to conventional open heart surgery. Currently, planning of mini-AVR consists of selection of the intercostal space closest to the sinotubular junction on preoperative computer tomography images. We developed an automated algorithm detecting the sinotubular junction (STJ) and intercostal spaces for finding the optimal incision location. The accuracy of the STJ detection was assessed by comparison with manual delineation by measuring the Euclidean distance between the manually and automatically detected points. In all 20 patients, the intercostal spaces were accurately detected. The median distance between automated and manually detected STJ locations was 1.4 [IQR= 0.91-4.7] mm compared to the interobserver variation of 1.0 [IQR= 0.54-1.3] mm. For 60% of patients, the fourth intercostal space was the closest to the STJ. The proposed algorithm is the first automated approach for detecting optimal incision location and has the potential to be implemented in clinical practice for planning of various mini-AVR procedures.


Subject(s)
Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Computed Tomography Angiography/methods , Heart Valve Prosthesis Implantation , Minimally Invasive Surgical Procedures , Aged , Aged, 80 and over , Algorithms , Automation , Female , Humans , Male
4.
Med Image Anal ; 18(1): 50-62, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24091241

ABSTRACT

A collaborative framework was initiated to establish a community resource of ground truth segmentations from cardiac MRI. Multi-site, multi-vendor cardiac MRI datasets comprising 95 patients (73 men, 22 women; mean age 62.73±11.24years) with coronary artery disease and prior myocardial infarction, were randomly selected from data made available by the Cardiac Atlas Project (Fonseca et al., 2011). Three semi- and two fully-automated raters segmented the left ventricular myocardium from short-axis cardiac MR images as part of a challenge introduced at the STACOM 2011 MICCAI workshop (Suinesiaputra et al., 2012). Consensus myocardium images were generated based on the Expectation-Maximization principle implemented by the STAPLE algorithm (Warfield et al., 2004). The mean sensitivity, specificity, positive predictive and negative predictive values ranged between 0.63 and 0.85, 0.60 and 0.98, 0.56 and 0.94, and 0.83 and 0.92, respectively, against the STAPLE consensus. Spatial and temporal agreement varied in different amounts for each rater. STAPLE produced high quality consensus images if the region of interest was limited to the area of discrepancy between raters. To maintain the quality of the consensus, an objective measure based on the candidate automated rater performance distribution is proposed. The consensus segmentation based on a combination of manual and automated raters were more consistent than any particular rater, even those with manual input. The consensus is expected to improve with the addition of new automated contributions. This resource is open for future contributions, and is available as a test bed for the evaluation of new segmentation algorithms, through the Cardiac Atlas Project (www.cardiacatlas.org).


Subject(s)
Algorithms , Coronary Artery Disease/pathology , Heart Ventricles/pathology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Pattern Recognition, Automated/methods , Ventricular Dysfunction, Left/pathology , Artificial Intelligence , Coronary Artery Disease/complications , Female , Humans , Image Enhancement/methods , Likelihood Functions , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Subtraction Technique , Ventricular Dysfunction, Left/etiology
SELECTION OF CITATIONS
SEARCH DETAIL