Article in English | MEDLINE | ID: mdl-38509402

ABSTRACT

BACKGROUND: Roughly one in six patients receiving conventional transvenous pacemaker systems experience significant complications within 1 year of implant, mainly due to the transvenous lead and subcutaneous pocket. A new helix-fixation single-chamber ventricular leadless pacemaker (LP) system capable of pre-deployment exploratory electrical mapping is commercially available. Such an LP may mitigate complications while streamlining the implantation. In this study, the initial real-world implant experience of the helix-fixation LP was evaluated following its commercial release. METHODS: In patients indicated for single-chamber right ventricular pacing, helix-fixation Aveir VR LPs (Abbott, Abbott Park, IL) were implanted using the dedicated loading tool, introducer, and delivery catheter. Implant procedural characteristics, electrical parameters, and any 30-day procedure-related adverse events of consecutive implant attempts were retrospectively evaluated. RESULTS: A total of 167 patients with Class I indication for permanent pacing received implants in four North American centers (57% male, 70 years old). Pre-fixation electrical mapping of potential sites allowed repositioning to be avoided in 95.7% of patients. Median [interquartile range] LP procedure and fluoroscopy durations were 25.5 min [20.0, 35.0] and 5.7 min [4.0, 9.2], respectively. Pacing capture threshold, sensed R-wave amplitude, and impedance were 0.8 V [0.5, 1.3], 9.0 mV [6.0, 12.0], and 705 Ω [550, 910], respectively. Implantation was successful in 98.8% of patients, with 98.2% free from acute adverse events. CONCLUSIONS: The initial, real-world experience of the helix-fixation ventricular leadless pacemaker demonstrated safe and efficient implantation with minimal repositioning, viable electrical metrics, and limited acute complications.

2.
J Cardiovasc Electrophysiol ; 34(2): 348-355, 2023 02.
Article in English | MEDLINE | ID: mdl-36448428

ABSTRACT

INTRODUCTION: Early and safe ambulation can facilitate same-day discharge (SDD) following catheter ablation, which can reduce resource utilization and healthcare costs and improve patient satisfaction. This study evaluated procedure success and safety of the VASCADE MVP venous vascular closure system in patients with atrial fibrillation (AF). METHODS: The AMBULATE SDD Registry is a two-stage series of postmarket studies in patients with paroxysmal or persistent AF undergoing catheter ablation followed by femoral venous access-site closure with VASCADE MVP. Efficacy endpoints included SDD success, defined as the proportion of patients discharged the same day who did not require next-day hospital intervention for procedure/access site-related complications, and access site sustained success within 15 days of the procedure. RESULTS: Overall, 354 patients were included in the pooled study population, 151 (42.7%) treated for paroxysmal AF and 203 (57.3%) for persistent AF. SDD was achieved in 323 patients (91.2%) and, of these, 320 (99.1%) did not require subsequent hospital intervention based on all study performance outcomes. Nearly all patients (350 of 354; 98.9%) achieved total study success, with no subsequent hospital intervention required. No major access-site complications were recorded. Patients who had SDD were more likely to report procedure satisfaction than patients who stayed overnight. CONCLUSION: In this study, 99.7% of patients achieving SDD required no additional hospital intervention for access site-related complications during follow-up. SDD appears feasible and safe for eligible patients after catheter ablation for paroxysmal or persistent AF in which the VASCADE MVP is used for venous access-site closure.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Patient Discharge , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Patient Satisfaction , Catheter Ablation/adverse effects , Catheter Ablation/methods , Registries , Treatment Outcome
3.
Heart Rhythm O2 ; 3(4): 396-404, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36097459

ABSTRACT

Background: Hybrid Convergent ablation for atrial fibrillation (AF) combines minimally invasive surgical (epicardial) and catheter (endocardial) ablation. The procedural goal is to achieve more extensive, enduring ablation of AF substrate around the pulmonary veins, posterior wall, and vestibule of the posterior wall left atrium. Objective: To perform a systematic review and meta-analysis on safety and effectiveness of contemporary Hybrid Convergent procedures. Methods: PubMed, Embase, and manual searches identified primary research articles on Hybrid Convergent. Inclusion criteria focused on contemporary practices (epicardial ablation device and lesions). Clinical outcomes at 1 year or later follow-up, patient population, procedural details, and major adverse events (MAE) were recorded. Results: Of 249 records, 6 studies (5 observational, 1 randomized controlled trial) including 551 patients were included. Endocardial energy sources included radiofrequency and cryoballoon. Hybrid Convergent ablation was mostly performed in patients with drug-refractory persistent and longstanding persistent AF. Mean preprocedural AF duration ranged between 2 and 5.1 years. Most patients (∼92%) underwent Hybrid Convergent in a single hospitalization. At 1 year follow-up or later, 69% (95% confidence interval [CI]: 61%-78%, n = 523) were free from atrial arrhythmias and 50% (95% CI: 42%-58%, n = 343) were free from atrial arrhythmias off antiarrhythmic drugs. Thirty-day MAE rate was 6% (95% CI: 3%-8%, n = 551). Conclusion: Hybrid Convergent ablation is an effective ablation strategy for persistent and longstanding persistent AF. Contemporary procedural approaches and published strategies aim to mitigate complications reported in early experience and address delayed inflammatory effusions.

4.
Heart Rhythm ; 19(5): 776-781, 2022 05.
Article in English | MEDLINE | ID: mdl-35066177

ABSTRACT

BACKGROUND: Complications associated with transvenous pacemakers, specifically those involving the lead or subcutaneous pocket, may be avoided with leadless pacemakers (LPs). The safety and efficacy of single-chamber right ventricular LPs have been demonstrated, but their right atrium (RA) use poses new design constraints. OBJECTIVES: The purpose of this study was to evaluate the implant success, electrical performance, and safety of a novel RA LP design in benchtop and preclinical studies. METHODS: A new LP was designed with a dual-helix fixation mechanism specific to the RA anatomy. A 12-week preclinical ovine study was conducted to evaluate implant success, electrical performance, mechanical stability, and safety in vivo, with supporting benchtop measurements to quantify the mechanical forces needed for device retrieval and dislodgment. RESULTS: LPs were successfully implanted in all 10 ovine subjects with no complications. The pacing capture threshold improved significantly over time from implant to week 12 (1.1 ± 0.7 V vs 0.4 ± 0.2 V, P = .008). Sensing amplitudes and pacing impedances were stable from implant to week 12 (4.8 ± 1.8 mV vs 6.0 ± 1.9 mV, P = .160; and 393 ± 77 Ω vs 398 ± 65 Ω, P = .922, respectively). Gross pathology and microscopic histology revealed no adverse interactions and no evidence of device dislodgment or clinically significant myocardial perforation. Benchtop ex vivo porcine atrial tissue measurements revealed greater pull forces required to dislodge the LP vs transvenous active fixation lead (0.42 ± 0.18 lbf vs 0.29 ± 0.08 lbf, P = .020), and greater rotational forces required for deliberate extraction (0.28 ± 0.04 lbf vs 0.14 ± 0.07 lbf, P <.001). CONCLUSION: The novel atrial LP demonstrated successful implantation, with acceptable electrical performance, mechanical stability, and safety in a 12-week preclinical study.


Subject(s)
Lipopolysaccharides , Pacemaker, Artificial , Animals , Cardiac Pacing, Artificial , Equipment Design , Heart Atria , Humans , Prostheses and Implants , Sheep , Swine , Treatment Outcome
5.
J Cardiovasc Electrophysiol ; 32(10): 2729-2736, 2021 10.
Article in English | MEDLINE | ID: mdl-34374160

ABSTRACT

BACKGROUND: Patients with wire and catheter refractory venous occlusion are traditionally referred for pectoral transvenous lead extraction (TLE) to obtain venous access. TLE causes 1-2 mm circumferential mechanical or laser destruction of tissue surrounding the lead(s). This not only exposes the patient to the risk of major complications but also can damage nontargeted leads. We present a series of patients where retained wire femoral lead removal and fibroplasty was used to obtain venous access in patients with refractory obstruction. METHODS: Between 2008 and 2021, we identified 17 patients where retained wire lead removal followed by fibroplasty was used to retain venous access. Demographic and procedural data were obtained by retrospective review of patient charts. RESULTS: We were able to successfully obtain venous access in all 17 patients in whom this technique was attempted. In two patients the target lead was less than or equal to 1 year old. In the remaining 15 patients, the average dwell time of the target lead(s) was 6 years. There were no procedure-related complications, and no changes in the parameters of other leads were noted. CONCLUSION: Retained wire femoral lead removal and fibroplasty is safe and highly efficacious at obtaining venous access in patients with refractory venous occlusion. If the target lead(s) is less than or equal to 1 year old, this technique can help obtain venous access at the time of the initial surgery, hence avoiding the need for TLE. Furthermore, in patients referred for TLE to obtain venous access, this technique by avoiding the use of TLE tools spares the patient of the associated risks.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Device Removal/adverse effects , Femoral Artery , Humans , Retrospective Studies
6.
Heart Rhythm ; 18(7): 1142-1150, 2021 07.
Article in English | MEDLINE | ID: mdl-33781980

ABSTRACT

BACKGROUND: Cardiac device procedures require tissue dissection to free existing device lead(s). Common techniques include blunt dissection, standard electrocautery, and low-temperature electrocautery (PlasmaBlade, Medtronic); however, data on the type of electrosurgical tool used and the development of procedure- or lead-related adverse events are limited. OBJECTIVE: The purpose of this study was to determine whether standard or low-temperature electrocautery impacts the development of an adverse event. METHODS: We evaluated patients enrolled in WRAP-IT (Worldwide Randomized Antibiotic EnveloPe Infection PrevenTion Trial) undergoing cardiac implantable electronic device (CIED) revision, upgrade, or replacement. All adverse events were adjudicated by an independent physician committee. Data were analyzed using Cox proportional hazard regression modeling. RESULTS: In total, 5641 patients underwent device revision/upgrade/replacement. Electrocautery was used in 5205 patients (92.3%) (mean age 70.6 ± 12.7 years; 28.8% female), and low-temperature electrocautery was used in 1866 patients (35.9%). Compared to standard electrocautery, low-temperature electrocautery was associated with a 23% reduction in the incidence of a procedure- or lead-related adverse event through 3 years of follow up (hazard ratio [HR] 0.77; 95% confidence interval [CI] 0.65-0.91; P = .002). After controlling for the number of active leads, degree of capsulectomy, degree of lead dissection, and renal dysfunction, low-temperature electrocautery was associated with a 32% lower risk of lead-related adverse events (HR 0.68; 95% CI 0.52-0.89; P = .004). These effects were consistent across a spectrum of lead-related adverse event types. CONCLUSION: This study represents one of the largest assessments of electrocautery use in patients undergoing CIED revision, upgrade, or replacement procedures. Compared to standard electrocautery, low-temperature electrocautery significantly reduces adverse effects from these procedures.


Subject(s)
Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/adverse effects , Electrocoagulation/methods , Pacemaker, Artificial/adverse effects , Aged , Device Removal , Equipment Failure , Female , Follow-Up Studies , Humans , Male , Retrospective Studies , Temperature
7.
ESC Heart Fail ; 8(2): 1571-1581, 2021 04.
Article in English | MEDLINE | ID: mdl-33619893

ABSTRACT

AIMS: This study aims to characterize the range of implantable device-based sensor values including heart sounds, markers of ventilation, thoracic impedance, activity, and heart rate for patients with heart failure (HF) when patients were deemed to be in clinically stable periods against the time course of acute decompensation and recovery from HF events. METHODS AND RESULTS: The MultiSENSE trial followed 900 patients implanted with a COGNIS CRT-D for up to 1 year. Chronic, ambulatory diagnostic sensor data were collected and evaluated during clinically stable periods (CSP: unchanged NYHA classification, no adverse events, and weight change ≤2.27 kg), and in the timeframe leading up to and following HF events (HF admissions or unscheduled visits with intravenous HF treatment). Physiologic sensor data from 1667 CSPs occurring in 676 patients were compared with those data leading up to and following 192 HF events in 106 patients. Overall, the mean age was 66.6 years, and the population were predominantly male (73%). Patients were primarily in NYHA II (67%), with a mean LVEF of 29.6% and median NT-proBNP of 754.5 pg/mL. Sensor values during CSP were poorer in patients who had HF events during the study period than those without HF events, including first heart sound (S1: 2.18 ± 0.84 mG vs. 2.62 ± 0.95 mG, P = 0.002), third heart sound (S3: 1.13 ± 0.36 mG vs. 0.91 ± 0.30 mG, P < 0.001), thoracic impedance (45.66 ± 8.78 Ohm vs. 50.33 ± 8.43 Ohm, P < 0.001), respiratory rate (19.09 ± 3.10 br/min vs. 17.66 ± 2.39 br/min, P = 0.002), night time heart rate (73.39 ± 8.36 b.p.m. vs. 69.56 ± 8.09 b.p.m., P = 0.001), patient activity (1.69 ± 1.84 h vs. 2.56 ± 2.20 h, P = 0.006), and HeartLogic index (11.07 ± 12.14 vs. 5.31 ± 5.13, P = 0.001). Sensor parameters measured worsening status leading up to HF events with recovery of values following treatment. CONCLUSIONS: Device-based physiologic sensors not only revealed progressive worsening leading up to HF events but also differentiated patients at increased risk of HF events when presumed to be clinically stable.


Subject(s)
Heart Failure , Aged , Heart Failure/diagnosis , Heart Rate , Hospitalization , Humans , Male
8.
J Atr Fibrillation ; 12(6): 2361, 2020.
Article in English | MEDLINE | ID: mdl-33024494

ABSTRACT

Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Yet tools and techniques used for confirmation of PVI vary greatly, and it is unclear whether the use of any particular combination of tools and techniques provides greater sensitivity for identifying gaps periprocedurally. It has been suggested the use of a high-density mapping catheter, which enables simultaneous recording of adjacent bipolar EGMs in two directions, may provide improved sensitivity for gap identification. Anonymized, acute procedural data was prospectively collected in AF ablation cases utilizing various workflows for confirmation of PVI. Post-hoc analysis was performed to evaluate the incidence of gaps detected by different diagnostic catheter technologies, including a high-density mapping catheter and circular mapping catheters (CMCs), and common techniques such as pacing the ablation lines. A total of 139 cases were included across three subgroup analyses: 99 cases were included in an indirect comparison of three mapping catheter technologies, revealing gaps in 36.7%, 38.9%, and 81.8% of cases utilizing a 10-pole CMC, 20-pole CMC, and a high-density mapping catheter, respectively; a direct comparison of diagnostic catheter technologies in 18 cryoballoon ablation cases revealed residual gaps in 22.2% of patients identified by high-density mapping which were missed previously with the use of a 3.3F CMC; in 22 cases utilizing a technique of pacing the ablation lines, high-density mapping identified residual gaps in 68.2% of patients. This proof of concept analysis demonstrated that the use of a high-density catheter which records orthogonal bipoles simultaneously, appears to improve acute detection of gaps in PVI lines relative to other commonly utilized techniques and technologies. The long-term impact of ablating these concealed gaps remains unclear. Further study, including direct comparison of diagnostic catheter technologies in a randomized setting with long-term followup, is warranted.

9.
Circ Arrhythm Electrophysiol ; 13(10): e008503, 2020 10.
Article in English | MEDLINE | ID: mdl-32915063

ABSTRACT

BACKGROUND: In the WRAP-IT trial (Worldwide Randomized Antibiotic Envelope Infection Prevention), adjunctive use of an absorbable antibacterial envelope resulted in a 40% reduction of major cardiac implantable electronic device infection without increased risk of complication in 6983 patients undergoing cardiac implantable electronic device revision, replacement, upgrade, or initial cardiac resynchronization therapy defibrillator implant. There is limited information on the cost-effectiveness of this strategy. As a prespecified objective, we evaluated antibacterial envelope cost-effectiveness compared with standard-of-care infection prevention strategies in the US healthcare system. METHODS: A decision tree model was used to compare costs and outcomes of antibacterial envelope (TYRX) use adjunctive to standard-of-care infection prevention versus standard-of-care alone over a lifelong time horizon. The analysis was performed from an integrated payer-provider network perspective. Infection rates, antibacterial envelope effectiveness, infection treatment costs and patterns, infection-related mortality, and utility estimates were obtained from the WRAP-IT trial. Life expectancy and long-term costs associated with device replacement, follow-up, and healthcare utilization were sourced from the literature. Costs and quality-adjusted life years were discounted at 3%. An upper willingness-to-pay threshold of $150 000 per quality-adjusted life year was used to determine cost-effectiveness, in alignment with the American College of Cardiology/American Heart Association practice guidelines and as supported by the World Health Organization and contemporary literature. RESULTS: The base case incremental cost-effectiveness ratio of the antibacterial envelope compared with standard-of-care was $112 603/quality-adjusted life year. The incremental cost-effectiveness ratio remained lower than the willingness-to-pay threshold in 74% of iterations in the probabilistic sensitivity analysis and was most sensitive to the following model inputs: infection-related mortality, life expectancy, and infection cost. CONCLUSIONS: The absorbable antibacterial envelope was associated with a cost-effectiveness ratio below contemporary benchmarks in the WRAP-IT patient population, suggesting that the envelope provides value for the US healthcare system by reducing the incidence of cardiac implantable electronic device infection. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02277990.


Subject(s)
Anti-Bacterial Agents/economics , Antibiotic Prophylaxis/economics , Cardiac Resynchronization Therapy Devices/economics , Defibrillators, Implantable/economics , Drug Costs , Prosthesis Implantation/economics , Prosthesis-Related Infections/economics , Absorbable Implants/economics , Anti-Bacterial Agents/therapeutic use , Cardiac Resynchronization Therapy Devices/adverse effects , Clinical Decision-Making , Cost Savings , Cost-Benefit Analysis , Decision Trees , Defibrillators, Implantable/adverse effects , Humans , Models, Economic , Multicenter Studies as Topic , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/prevention & control , Quality of Life , Quality-Adjusted Life Years , Randomized Controlled Trials as Topic , Risk Factors , Time Factors , Treatment Outcome , United States
10.
Clin Transl Sci ; 13(3): 618-627, 2020 05.
Article in English | MEDLINE | ID: mdl-31961467

ABSTRACT

Most literature describing pharmacogenetic implementations are within academic medical centers and use single-gene tests. Our objective was to describe the results and lessons learned from a multisite pharmacogenetic pilot that utilized panel-based testing in academic and nonacademic settings. This was a retrospective analysis of 667 patients from a pilot in 4 perioperative and 5 outpatient cardiology clinics. Recommendations related to 12 genes and 65 drugs were classified as actionable or not actionable. They were ascertained from Clinical Pharmacogenetics Implementation Consortium (CPIC) guidelines and US Food and Drug Administration (FDA) labeling. Patients displayed a high prevalence of actionable results (88%, 99%) and use of medications (28%, 46%) with FDA or CPIC recommendations, respectively. Sixteen percent of patients had an actionable result for a current medication per CPIC compared with 5% per FDA labeling. A systematic approach by a health system may be beneficial given the quantity and diversity of patients affected.


Subject(s)
Ambulatory Care/statistics & numerical data , Perioperative Care/statistics & numerical data , Pharmacogenomic Testing/statistics & numerical data , Practice Patterns, Physicians'/statistics & numerical data , Precision Medicine/statistics & numerical data , Aged , Ambulatory Care/standards , District of Columbia , Female , Humans , Male , Maryland , Middle Aged , Perioperative Care/standards , Pharmacogenomic Testing/standards , Pilot Projects , Practice Guidelines as Topic , Practice Patterns, Physicians'/standards , Precision Medicine/methods , Precision Medicine/standards , Retrospective Studies , United States , United States Food and Drug Administration/standards
11.
N Engl J Med ; 380(20): 1895-1905, 2019 05 16.
Article in English | MEDLINE | ID: mdl-30883056

ABSTRACT

BACKGROUND: Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. METHODS: We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. RESULTS: A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P = 0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P<0.001 for noninferiority). The mean (±SD) duration of follow-up was 20.7±8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). CONCLUSIONS: Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications. (Funded by Medtronic; WRAP-IT ClinicalTrials.gov number, NCT02277990.).


Subject(s)
Anti-Bacterial Agents/administration & dosage , Antibiotic Prophylaxis , Bacterial Infections/prevention & control , Defibrillators, Implantable/adverse effects , Heart Diseases/therapy , Minocycline/administration & dosage , Pacemaker, Artificial/adverse effects , Prosthesis-Related Infections/prevention & control , Rifampin/administration & dosage , Aged , Anti-Bacterial Agents/adverse effects , Bacterial Infections/epidemiology , Bacterial Infections/mortality , Female , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Minocycline/adverse effects , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/mortality , Rifampin/adverse effects , Single-Blind Method , Standard of Care
12.
J Am Coll Cardiol ; 66(5): 524-31, 2015 Aug 04.
Article in English | MEDLINE | ID: mdl-26227190

ABSTRACT

BACKGROUND: Heart failure patients with primary prevention implantable cardioverter-defibrillators (ICD) may experience an improvement in left ventricular ejection fraction (LVEF) over time. However, it is unclear how LVEF improvement affects subsequent risk for mortality and sudden cardiac death. OBJECTIVES: This study sought to assess changes in LVEF after ICD implantation and the implication of these changes on subsequent mortality and ICD shocks. METHODS: We conducted a prospective cohort study of 538 patients with repeated LVEF assessments after ICD implantation for primary prevention of sudden cardiac death. The primary endpoint was appropriate ICD shock defined as a shock for ventricular tachyarrhythmias. The secondary endpoint was all-cause mortality. RESULTS: Over a mean follow-up of 4.9 years, LVEF decreased in 13.0%, improved in 40.0%, and was unchanged in 47.0% of the patients. In the multivariate Cox models comparing patients with an improved LVEF with those with an unchanged LVEF, the hazard ratios were 0.33 (95% confidence interval: 0.18 to 0.59) for mortality and 0.29 (95% confidence interval: 0.11 to 0.78) for appropriate shock. During follow-up, 25% of patients showed an improvement in LVEF to >35% and their risk of appropriate shock decreased but was not eliminated. CONCLUSIONS: Among primary prevention ICD patients, 40.0% had an improved LVEF during follow-up and 25% had LVEF improved to >35%. Changes in LVEF were inversely associated with all-cause mortality and appropriate shocks for ventricular tachyarrhythmias. In patients whose follow-up LVEF improved to >35%, the risk of an appropriate shock remained but was markedly decreased.


Subject(s)
Cardiac Resynchronization Therapy , Death, Sudden, Cardiac , Electric Countershock , Heart Failure , Ventricular Dysfunction, Left , Aged , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy/statistics & numerical data , Cohort Studies , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electric Countershock/instrumentation , Electric Countershock/methods , Female , Heart Failure/complications , Heart Failure/therapy , Humans , Incidence , Male , Middle Aged , Proportional Hazards Models , Prospective Studies , Risk Assessment , Severity of Illness Index , Stroke Volume , United States/epidemiology , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/mortality
13.
Heart Rhythm ; 12(2): 360-6, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25446153

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillator (ICD) implantation is contraindicated in those with <1-year life expectancy. OBJECTIVES: The aim of this study was to develop a risk prediction score for 1-year mortality in patients with primary prevention ICDs and to determine the incremental improvement in discrimination when serum-based biomarkers are added to traditional clinical variables. METHODS: We analyzed data from the Prospective Observational Study of Implantable Cardioverter-Defibrillators, a large prospective observational study of patients undergoing primary prevention ICD implantation who were extensively phenotyped for clinical and serum-based biomarkers. We identified variables predicting 1-year mortality and synthesized them into a comprehensive risk scoring construct using backward selection. RESULTS: Of 1189 patients deemed by their treating physicians as having a reasonable 1-year life expectancy, 62 (5.2%) patients died within 1 year of ICD implantation. The risk score, composed of 6 clinical factors (age ≥75 years, New York Heart Association class III/IV, atrial fibrillation, estimated glomerular filtration rate <30 mL/min/1.73 m(2), diabetes, and use of diuretics), had good discrimination (area under the curve 0.77) for 1-year mortality. Addition of 3 biomarkers (tumor necrosis factor α receptor II, pro-brain natriuretic peptide, and cardiac troponin T) further improved model discrimination to 0.82. Patients with 0-1, 2-3, 4-6, or 7-9 risk factors had 1-year mortality rates of 0.8%, 2.7%, 16.1%, and 46.2%, respectively. CONCLUSION: Individuals with more comorbidities and elevation of specific serum biomarkers were at increased risk of all-cause mortality despite being deemed as having a reasonable 1-year life expectancy. A simple risk score composed of readily available clinical data and serum biomarkers may better identify patients at high risk of early mortality and improve patient selection and counseling for primary prevention ICD therapy.


Subject(s)
Biomarkers/blood , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Heart Failure/blood , Primary Prevention/methods , Risk Assessment , Aged , Creatine Kinase, MB Form/blood , Death, Sudden, Cardiac/epidemiology , Female , Heart Failure/mortality , Heart Failure/therapy , Humans , Incidence , Male , Middle Aged , Natriuretic Peptide, Brain/blood , Netherlands/epidemiology , Peptide Fragments/blood , Prognosis , Prospective Studies , Protein Precursors , Risk Factors , Survival Rate/trends , Troponin T/blood , United States/epidemiology
14.
Circ Arrhythm Electrophysiol ; 7(6): 1084-91, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25273351

ABSTRACT

BACKGROUND: Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality, but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation, and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs. METHODS AND RESULTS: The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end point was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary end point was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable-adjusted models, higher interleukin-6 levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, interleukin-6, tumor necrosis factor-α receptor II, pro-brain natriuretic peptide (pro-BNP), and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD. CONCLUSIONS: An increase in serum biomarkers of inflammation, neurohumoral activation, and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs. CLINICAL TRIAL REGISTRATION URL: clinicaltrials.gov; Unique Identifier: NCT00733590.


Subject(s)
Blood Proteins/analysis , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electric Countershock/instrumentation , Primary Prevention/instrumentation , Aged , Biomarkers/blood , Chi-Square Distribution , Death, Sudden, Cardiac/etiology , Female , Humans , Inflammation Mediators/blood , Linear Models , Male , Middle Aged , Multivariate Analysis , Myocardium/metabolism , Natriuretic Peptide, Brain/blood , Patient Selection , Predictive Value of Tests , Primary Prevention/methods , Proportional Hazards Models , Prospective Studies , Protein Precursors/blood , Risk Assessment , Risk Factors , United States/epidemiology
15.
Heart Rhythm ; 11(8): 1377-83, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24793459

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) reduce the risk of death in patients with left ventricular dysfunction. Little is known regarding the benefit of this therapy in African Americans (AAs). OBJECTIVE: The purpose of this study was to determine the association between AA race and outcomes in a cohort of primary prevention ICD patients. METHODS: We conducted a prospective cohort study of patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end-point was appropriate ICD shock defined as a shock for rapid ventricular tachyarrhythmias. The secondary end-point was all-cause mortality. RESULTS: There were 1189 patients (447 AAs and 712 non-AAs) enrolled. Over a median follow-up of 5.1 years, a total of 137 patients experienced an appropriate ICD shock, and 343 died (294 of whom died without receiving an appropriate ICD shock). The multivariate adjusted hazard ratio (95% confidence interval) comparing AAs vs non-AAs were 1.24 (0.96-1.59) for all-cause mortality, 1.33 (1.02, 1.74) for all-cause mortality without receiving appropriate ICD shock, and 0.78 (0.51, 1.19) for appropriate ICD shock. Ejection fraction, diabetes, and hypertension appeared to explain 24.1% (10.1%-69.5%), 18.7% (5.3%-58.0%), and 13.6% (3.8%-53.6%) of the excess risk of mortality in AAs, with a large proportion of the mortality difference remaining unexplained. CONCLUSION: In patients with primary prevention ICDs, AAs had an increased risk of dying without receiving an appropriate ICD shock compared to non-AAs.


Subject(s)
Black or African American , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Primary Prevention/methods , Risk Assessment , Ventricular Dysfunction, Left/therapy , Death, Sudden, Cardiac/epidemiology , Female , Follow-Up Studies , Humans , Incidence , Male , Middle Aged , Prognosis , Prospective Studies , Risk Factors , United States/epidemiology , Ventricular Dysfunction, Left/ethnology , Ventricular Dysfunction, Left/physiopathology
16.
J Am Heart Assoc ; 2(1): e000083, 2013 Feb 22.
Article in English | MEDLINE | ID: mdl-23525420

ABSTRACT

BACKGROUND: Primary-prevention implantable cardioverter-defibrillators (ICDs) reduce total mortality in patients with severe left ventricular systolic function. However, only a minority of patients benefit from these devices. We designed the Prospective Observational Study of Implantable Cardioverter-Defibrillators (PROSE-ICD) to identify risk factors and enhance our understanding of the biological mechanisms that predispose to arrhythmic death in patients undergoing ICD implantation for primary prevention of sudden death. METHODS AND RESULTS: This is a multicenter prospective cohort study with a target enrollment of 1200 patients. The primary end point is ICD shocks for adjudicated ventricular tachyarrhythmias. The secondary end point is total mortality. All patients undergo a comprehensive evaluation including history and physical examination, signal-averaged electrocardiograms, and blood sampling for genomic, proteomic, and metabolomic analyses. Patients are evaluated every 6 months and after every known ICD shock for additional electrocardiographic and blood sampling. As of December 2011, a total of 1177 patients have been enrolled with more nonwhite and female patients compared to previous randomized trials. A total of 143 patients have reached the primary end point, whereas a total of 260 patients died over an average follow-up of 59 months. The PROSE-ICD study represents a real-world cohort of individuals with systolic heart failure receiving primary-prevention ICDs. CONCLUSIONS: Extensive electrophysiological and structural phenotyping as well as the availability of serial DNA and serum samples will be important resources for evaluating novel metrics for risk stratification and identifying patients at risk for arrhythmic sudden death. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/ Unique Identifier: NCT00733590.


Subject(s)
Arrhythmias, Cardiac/therapy , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electric Countershock/instrumentation , Heart Failure/therapy , Primary Prevention/instrumentation , Research Design , Aged , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , Biomarkers/blood , Death, Sudden, Cardiac/etiology , Electrocardiography , Female , Heart Failure/complications , Heart Failure/diagnosis , Heart Failure/mortality , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Physical Examination , Predictive Value of Tests , Primary Prevention/methods , Proportional Hazards Models , Prospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , United States
17.
Clin Geriatr Med ; 29(1): 205-30, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23177608

ABSTRACT

Palpitations are a common complaint among elderly patients presenting to the emergency department. Although most are benign, the elderly do have a higher risk of having a cardiac cause. Other causes include psychiatric disorders, and sometimes a combination of cardiac and psychiatric causes coexist. A history and physical examination, including a detailed medication history, are an essential part of the workup in older patients. A 12-lead electrocardiogram is an essential first step toward a diagnosis; other tests are recommended in high-risk patients, including those with underlying coronary artery disease or structural cardiac abnormalities.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Emergency Treatment/methods , Tachycardia/diagnosis , Tachycardia/therapy , Aged , Aged, 80 and over , Aging/physiology , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Electrocardiography , Emergencies , Emergency Service, Hospital , Humans , Middle Aged , Physical Examination , Risk Factors , Tachycardia/epidemiology , Tachycardia/physiopathology
18.
Am J Cardiol ; 109(10): 1466-71, 2012 May 15.
Article in English | MEDLINE | ID: mdl-22356796

ABSTRACT

Cardiac device infections (CDIs) represent a serious complication after the implantation of pacemakers and defibrillators. In addition to antimicrobials, complete hardware removal, mostly with percutaneous lead extraction (PLE), is necessary to limit recurrences. However, CDI diagnosis is often difficult and is sometimes delayed, and scarce data exist on how the timing of PLE may affect clinical outcomes. In this study, the in-hospital outcomes of 52 consecutive patients with CDIs who underwent PLE were retrospectively analyze. Co-morbidities such as diabetes mellitus, congestive heart failure, renal insufficiency, and end-stage renal disease were highly prevalent in the study cohort. Patients were divided into group A (bacteremia or device endocarditis) and group B (localized pocket infection). In-hospital mortality was 29% in group A and 5% in group B (p = 0.02) and was due mostly to sepsis. Hospital stays were shorter in group B patients (5.7 vs 21.7 days, p <0.001). Presentation with hypotension was more commonly observed in group A patients and was associated with higher in-hospital mortality, whereas pocket findings correlated with better survival. Postoperative courses after PLE were uneventful in most patients, and no fatal complications were observed. PLE was performed significantly earlier in group B patients (hospitalization day 1.3 vs 7.6, p <0.001). PLE performed within 3 hospitalization days was associated with lower in-hospital mortality (p = 0.01). In conclusion, PLE performed within 3 days from admission is associated with shorter hospitalization and better survival. A timely diagnosis is crucial, particularly in the absence of local findings, because early treatment with PLE is likely to prevent the catastrophic outcomes of unrelenting CDIs.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Defibrillators, Implantable/adverse effects , Device Removal/methods , Early Diagnosis , Endocarditis, Bacterial/diagnosis , Prosthesis-Related Infections/diagnosis , Staphylococcal Infections/diagnosis , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/microbiology , Diagnosis, Differential , Echocardiography , Endocarditis, Bacterial/mortality , Endocarditis, Bacterial/therapy , Female , Follow-Up Studies , Hospital Mortality/trends , Humans , Male , Middle Aged , Prosthesis-Related Infections/mortality , Prosthesis-Related Infections/therapy , Retrospective Studies , Staphylococcal Infections/mortality , Staphylococcal Infections/therapy , Staphylococcus aureus/isolation & purification , Survival Rate/trends , Treatment Outcome , United States/epidemiology
19.
Seizure ; 20(10): 817-9, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21868257

ABSTRACT

Ictal asystole is a presumably rare but potentially fatal complication of seizures, most often of temporal lobe origin. It is believed that at least some cases of sudden unexplained death in epilepsy (SUDEP) might be triggered by ictal bradycardia or asystole. Current standard practice is to implant a permanent pacemaker in these patients to prevent syncope and/or death. However, emerging data suggests that effective medical or surgical treatment of epilepsy might be enough to prevent cardiac asystole, eliminating the need for permanent pacemaker placement. We describe a case of new onset left frontal lobe epilepsy in a young athletic patient who presented with near-syncopal episodes but whose comprehensive work-up revealed frequent events of ictal bradycardia and asystole. He responded well to monotherapy using oxcarbazepine, avoiding a permanent pacemaker.


Subject(s)
Frontal Lobe/physiopathology , Heart Arrest/etiology , Seizures/complications , Adult , Anticonvulsants/therapeutic use , Bradycardia/etiology , Carbamazepine/analogs & derivatives , Carbamazepine/therapeutic use , Electrocardiography , Electroencephalography , Humans , Male , Oxcarbazepine , Seizures/drug therapy , Seizures/physiopathology
20.
Heart Rhythm ; 3(4): 435-42, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16567291

ABSTRACT

BACKGROUND: RV pacing induces conduction delay (CD), mechanical dyssynchrony, and increased morbidity in patients with HF. CRT improves HF symptoms and survival, but sparse data exist on its direct effect on chronically RV-paced HF patients. OBJECTIVES: To assess the benefit of cardiac resynchronization therapy (CRT) in chronically right ventricle (RV)-paced heart failure (HF) patients. METHODS: We studied 12 consecutive patients with class III HF who had a previously implanted pacemaker or implantable cardioverter-defibrillator. These individuals were chronically RV paced and referred for upgrade to a biventricular device by their primary cardiologists. Tissue Doppler and strain rate imaging (TDI and SRI, respectively) were performed immediately before each upgrade and 4-6 weeks afterward to quantify changes in regional wall motion and synchrony with CRT. RESULTS: CRT significantly reduced the mean QRS duration (205 ms to 156 ms; P<.0001), and it increased the ejection fraction (30.7%+/-5.1% to 35.8%+/-5.1%; P<.01). Left ventricular end-systolic and end-diastolic dimensions were also significantly reduced. Clinically, patients improved by an average of one New York Heart Association (NYHA) functional class after upgrade (P = .006). The parameter exhibiting greatest improvement was the coefficient of variation (CoV: standard deviation/mean) of time to peak systolic strain rate, a marker of ventricular dyssynchrony, which decreased from 34.3%+/-13.0% to 19.0%+/-6.6% (P<.01). Reduction in CoV of time to peak systolic strain rate was maximally seen in the midventricle (38.2%+/-19.6% to 16.5%+/-9.7%; P<.01). CONCLUSIONS: Upgrading chronically RV-paced HF patients to CRT improves global and regional systolic function. TDI and SRI provide compelling evidence that this benefit parallels that seen in HF patients with CD unrelated to RV pacing, which implies that biventricular pacing synchronizes mechanical activation in different myocardial regions in patients upgraded from RV pacing as well.


Subject(s)
Cardiac Pacing, Artificial , Echocardiography , Heart Failure/physiopathology , Heart Failure/therapy , Aged , Aged, 80 and over , Analysis of Variance , Chronic Disease , Defibrillators, Implantable , Female , Heart Conduction System/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/surgery , Heart Failure/diagnostic imaging , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Heart Ventricles/surgery , Humans , Male , Middle Aged , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/therapy , Myocardial Contraction , Pacemaker, Artificial , Severity of Illness Index , Stroke Volume , Treatment Outcome , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/surgery , Ventricular Function, Left , Ventricular Remodeling
SELECTION OF CITATIONS
SEARCH DETAIL
...