1.
Nat Commun ; 13(1): 364, 2022 Jan 18.
Article in English | MEDLINE | ID: mdl-35042881

ABSTRACT

The near-Earth asteroid (162173) Ryugu, the target of Hayabusa2 space mission, was observed via both orbiter and the lander instruments. The infrared radiometer on the MASCOT lander (MARA) is the only instrument providing spectrally resolved mid-infrared (MIR) data, which is crucial for establishing a link between the asteroid material and meteorites found on Earth. Earlier studies revealed that the single boulder investigated by the lander belongs to the most common type found on Ryugu. Here we show the spectral variation of Ryugu's emissivity using the complete set of in-situ MIR data and compare it to those of various carbonaceous chondritic meteorites, revealing similarities to the most aqueously altered ones, as well as to asteroid (101955) Bennu. The results show that Ryugu experienced strong aqueous alteration prior to any dehydration.

2.
Science ; 365(6455): 817-820, 2019 08 23.
Article in English | MEDLINE | ID: mdl-31439797

ABSTRACT

The near-Earth asteroid (162173) Ryugu is a 900-m-diameter dark object expected to contain primordial material from the solar nebula. The Mobile Asteroid Surface Scout (MASCOT) landed on Ryugu's surface on 3 October 2018. We present images from the MASCOT camera (MASCam) taken during the descent and while on the surface. The surface is covered by decimeter- to meter-sized rocks, with no deposits of fine-grained material. Rocks appear either bright, with smooth faces and sharp edges, or dark, with a cauliflower-like, crumbly surface. Close-up images of a rock of the latter type reveal a dark matrix with small, bright, spectrally different inclusions, implying that it did not experience extensive aqueous alteration. The inclusions appear similar to those in carbonaceous chondrite meteorites.

4.
Cerebrovasc Dis ; 11(2): 107-12, 2001.
Article in English | MEDLINE | ID: mdl-11223662

ABSTRACT

We prospectively evaluated 30 consecutive patients with echo-enhanced transcranial color-coded duplexsonography (TCCD) and correlative transfemoral digital subtraction angiography to assess the diagnostic efficacy of echo-enhanced TCCD for evaluation of collateral pathways through the circle of Willis in patients with limited acoustic bone windows and critical symptomatic carotid disease. Echo-enhanced TCCD detected collateral blood flow through the anterior communicating artery in 16 of 18 patients (sensitivity 89%, 95% CI 65-99%) and was false positive in one out of 12 patients without collateral flow (specificity 92%, 95% CI 59-100%). For the posterior communicating artery, sensitivity was 11/14 (79%, 95% CI 49-95%) and specificity was 15/16 (94%, 95% CI 70-100%). Echo-enhanced TCCD enables to study collateral blood flow through the communicating arteries of the circle of Willis with high sensitivity and specificity in patients with obstructions of the internal carotid artery and limited acoustic bone windows.


Subject(s)
Carotid Stenosis/physiopathology , Circle of Willis , Collateral Circulation , Ultrasonography, Doppler, Transcranial , Aged , Angiography, Digital Subtraction , Cerebrovascular Circulation , Contrast Media , Female , Humans , Male , Middle Aged , Polysaccharides , Prospective Studies , Sensitivity and Specificity , Ultrasonography, Doppler, Color , Ultrasonography, Doppler, Transcranial/methods