Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharmacol Toxicol Methods ; 68(1): 112-22, 2013.
Article in English | MEDLINE | ID: mdl-23651875

ABSTRACT

INTRODUCTION: Unwanted drug interactions with ionic currents in the heart can lead to an increased pro-arrhythmic risk to patients in the clinic. It is therefore a priority for safety pharmacology teams to detect block of cardiac ion channels, and new technologies have enabled the development of automated and high-throughput screening assays using cell lines. As a result of screening multiple ion-channels there is a need to integrate information, particularly for compounds affecting more than one current, and mathematical electrophysiology in-silico action potential models are beginning to be used for this. METHODS: We quantified the variability associated with concentration-effect curves fitted to recordings from high-throughput Molecular Devices IonWorks® Quattro™ screens when detecting block of I(Kr) (hERG), I(Na) (NaV1.5), I(CaL) (CaV1.2), I(Ks) (KCNQ1/minK) and I(to) (Kv4.3/KChIP2.2), and the Molecular Devices FLIPR® Tetra fluorescence screen for I(CaL) (CaV1.2), for control compounds used at AstraZeneca and GlaxoSmithKline. We examined how screening variability propagates through in-silico action potential models for whole cell electrical behaviour, and how confidence intervals on model predictions can be estimated with repeated simulations. RESULTS: There are significant levels of variability associated with high-throughput ion channel electrophysiology screens. This variability is of a similar magnitude for different cardiac ion currents and different compounds. Uncertainty in the Hill coefficients of reported concentration-effect curves is particularly high. Depending on a compound's ion channel blocking profile, the uncertainty introduced into whole-cell predictions can become significant. DISCUSSION: Our technique allows confidence intervals to be placed on computational model predictions that are based on high-throughput ion channel screens. This allows us to suggest when repeated screens should be performed to reduce uncertainty in a compound's action to acceptable levels, to allow a meaningful interpretation of the data.


Subject(s)
Computer Simulation , High-Throughput Screening Assays/methods , Ion Channels/drug effects , Models, Theoretical , Action Potentials/drug effects , Cell Line , Dose-Response Relationship, Drug , Drug Design , Humans , Ion Channels/metabolism , Myocytes, Cardiac/drug effects , Myocytes, Cardiac/metabolism , Patch-Clamp Techniques , Toxicity Tests
SELECTION OF CITATIONS
SEARCH DETAIL