Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
2.
Int J Nanomedicine ; 19: 3045-3070, 2024.
Article in English | MEDLINE | ID: mdl-38559447

ABSTRACT

Background: Diabetes Mellitus is a multisystem chronic pandemic, wound inflammation, and healing are still major issues for diabetic patients who may suffer from ulcers, gangrene, and other wounds from uncontrolled chronic hyperglycemia. Marshmallows or Althaea officinalis (A.O.) contain bioactive compounds such as flavonoids and phenolics that support wound healing via antioxidant, anti-inflammatory, and antibacterial properties. Our study aimed to develop a combination of eco-friendly formulations of green synthesis of ZnO-NPs by Althaea officinalis extract and further incorporate them into 2% chitosan (CS) gel. Method and Results: First, develop eco-friendly green Zinc Oxide Nanoparticles (ZnO-NPs) and incorporate them into a 2% chitosan (CS) gel. In-vitro study performed by UV-visible spectrum analysis showed a sharp peak at 390 nm, and Energy-dispersive X-ray (EDX) spectrometry showed a peak of zinc and oxygen. Besides, Fourier transforms infrared (FTIR) was used to qualitatively validate biosynthesized ZnO-NPs, and transmission electron microscope (TEM) showed spherical nanoparticles with mean sizes of 76 nm and Zeta potential +30mV. The antibacterial potential of A.O.-ZnO-NPs-Cs was examined by the diffusion agar method against Gram-positive (Staphylococcus aureus and Bacillus subtilis) and Gram-negative bacteria (Escherichia coli and Pseudomonas aeruginosa). Based on the zone of inhibition and minimal inhibitory indices (MIC). In addition, an in-silico study investigated the binding affinity of A.O. major components to the expected biological targets that may aid wound healing. Althaea Officinalis, A.O-ZnO-NPs group showed reduced downregulation of IL-6, IL-1ß, and TNF-α and increased IL-10 levels compared to the control group signaling pathway expression levels confirming the improved anti-inflammatory effect of the self-assembly method. In-vivo study and histopathological analysis revealed the superiority of the nanoparticles in reducing signs of inflammation and wound incision in rat models. Conclusion: These biocompatible green zinc oxide nanoparticles, by using Althaea Officinalis chitosan gel ensure an excellent new therapeutic approach for quickening diabetic wound healing.


Subject(s)
Althaea , Chitosan , Diabetes Mellitus , Metal Nanoparticles , Zinc Oxide , Humans , Animals , Rats , Zinc Oxide/chemistry , Chitosan/chemistry , Althaea/metabolism , Interleukin-6 , Tumor Necrosis Factor-alpha , Metal Nanoparticles/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Wound Healing , Anti-Inflammatory Agents/pharmacology , Inflammation , Flowers , Microbial Sensitivity Tests , Plant Extracts/pharmacology , Plant Extracts/chemistry , Spectroscopy, Fourier Transform Infrared , X-Ray Diffraction
3.
Int J Nanomedicine ; 19: 1163-1187, 2024.
Article in English | MEDLINE | ID: mdl-38344440

ABSTRACT

Purpose: Improving the treatment of psoriasis is a serious challenge today. Psoriasis is an immune-mediated skin condition affecting 125 million people worldwide. It is commonly treated with cyclosporine-A (CsA) and dithranol (DTH). CsA suppresses the activation of T-cells, immune cells involved in forming psoriatic lesions. Meanwhile, DTH is a potent anti-inflammatory and anti-proliferative drug that effectively reduces the severity of psoriasis symptoms such as redness, scaling, and skin thickness. CsA and DTH belong to BCS class II with limited oral bioavailability. We aim to develop a drug delivery system for topical co-delivery of CsA and DTH, exploring its therapeutic potential. Methods: Firstly, we developed a niosomal drug delivery system based on ceramide IIIB to form Cerosomes. Cerosomes were prepared from a mixture of Ceramide, hyaluronic acid, and edge activator using a thin-film hydration technique. To co-deliver CsA and DTH topically for the treatment of psoriasis. These two hydrophobic drugs encapsulated into our synthesized positively charged particle cerosomes. Results:  Cerosomes had an average particle size of (222.36 nm± 0.36), polydispersity index of (0.415±0.04), Entrapment Efficiency of (96.91%± 0.56), and zeta potential of (29.36±0.38mV) for selected formula. In vitro, In silico, in vivo, permeation, and histopathology experiments have shown that cerosomes enhanced the skin penetration of both hydrophobic drugs by 66.7% compared to the CsA/DTH solution. Imiquimod (IMQ) induced psoriatic mice model was topically treated with our CsA/DTH cerosomes. We found that our formulation enhances the skin penetration of both drugs and reduces psoriasis area and severity index (PASI score) by 2.73 times and 42.85%, respectively, compared to the CsA/DTH solution. Moreover, it reduces the levels of proinflammatory cytokines, TNF-α, IL-10, and IL-6 compared to CsA/DTH solution administration. Conclusion: The Cerosomes nano-vesicle-containing CsA/DTH represents a more promising topical treatment for psoriasis, giving new hope to individuals with psoriasis, compared to commercial and other conventional alternatives.


Subject(s)
Anthralin , Psoriasis , Humans , Animals , Mice , Anthralin/pharmacology , Anthralin/therapeutic use , Cyclosporine/pharmacology , Phospholipids , Ceramides/pharmacology , Administration, Cutaneous , Psoriasis/drug therapy , Psoriasis/pathology , Skin , Disease Models, Animal
4.
Pacing Clin Electrophysiol ; 47(2): 195-202, 2024 02.
Article in English | MEDLINE | ID: mdl-38214035

ABSTRACT

BACKGROUND: Peri-procedural complications associated with cardiac implantable electronic devices are not uncommon. European Society of Cardiology guidelines recommend device checks of all devices within 72 h of implant. European Heart Rhythm Association expert practical guide on Cardiac implantable electronic devices (CIEDs) recommend that a chest x-ray (CXR) should be performed within 24 h to rule out pneumothorax and document lead positions. First, the rate of peri-procedural complications associated with CIED implants at our center, as well as patient and/or procedural-related factors that are associated with higher rates of complications, is analyzed. Second, the yield of the guideline-recommended measures in the early detection of peri-procedural complications is examined. MATERIALS AND METHODS: Consecutive de novo transvenous device implants at our center in 2019 were retrospectively analyzed. Patients' demographics, types and indications for device therapy, procedural reports, device checks, and CXRs were obtained from the hospital electronic records. RESULTS: A total of 578 patients (Age 74 ± 16 years, 68% male) were included. All patients had routine post-procedure CXRs and device checks. There were 16 (2.8%) complications; 7 (1.2%) pneumothoraxes, 6 (1%) pericardial effusions, and 3 (0.5%) lead displacements. Procedure time correlated significantly with complications; in uncomplicated cases it was 99 ± 43 min versus 127 ± 50 min in procedures associated with complications (p = .02). CONCLUSIONS: Routine post CIED implantation CXRs can detect early peri-procedural complications, while repeat post mobilization device checks has low yield of detection of complications. The only statistically significant predictor of peri-procedural complications is the duration of the procedure; longer procedures were associated with higher rates of complications.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Female , Defibrillators, Implantable/adverse effects , Retrospective Studies , Heart , United Kingdom , Pacemaker, Artificial/adverse effects
5.
Indian Pacing Electrophysiol J ; 24(2): 94-104, 2024.
Article in English | MEDLINE | ID: mdl-38159808

ABSTRACT

We present the case of a 16-year-old male pediatric patient diagnosed with hypertrophic cardiomyopathy (HCM, identified as having a high risk of sudden cardiac death (SCD), who underwent a successful subcutaneous implantable cardiac defibrillator (S-ICD) implantation as a primary prevention measure in 2018. His past medical history included ADHD, Autism, and panic attacks. The patient experienced appropriate shocks that successfully terminated VF episodes. However, he also experienced multiple inappropriate shocks from the S-ICD, triggered by anxiety-induced tachycardia during panic episodes. Meticulous assessment of S-ICD tracings and electrocardiograms (ECGs) revealed the erroneous classification of sinus tachycardia as sustained ventricular tachycardia, leading to unwarranted therapeutic interventions. Clinical intervention involved reprogramming of the S-ICD, emphasizing the pivotal role of personalized device configuration in pediatric cases where fine margins matter. While literature on S-ICD use in pediatric populations remains limited, emerging registries underscore the efficacy and safety of S-ICDs in preventing sudden cardiac death while reducing complications associated with intravascular leads. This case underscores the critical nature of customized device programming in pediatric patients, underscoring S-ICDs as a practical defibrillation alternative that addresses distinct concerns within this cohort of patients.

6.
Drug Deliv ; 30(1): 2241665, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37537858

ABSTRACT

Canagliflozin (CFZ) is a sodium-glucose cotransporter-2 inhibitor (SGLT2) that lowers albuminuria in type-2 diabetic patients, cardiovascular, kidney, and liver disease. CFZ is classified as class IV in the Biopharmaceutical Classification System (BCS) and is characterized by low permeability, solubility, and bioavailability, most likely attributed to hepatic first-pass metabolism. Nanocrystal-based sublingual formulations were developed in the presence of sodium caprate, as a wetting agent, and as a permeability enhancer. This formulation is suitable for children and adults and could enhance solubility, permeability, and avoid enterohepatic circulation due to absorption through the sublingual mucosa. In the present study, formulations containing various surfactants (P237, P338, PVA, and PVP K30) were prepared by the Sono-homo-assisted precipitation ion technique. The optimized formula prepared with PVP-K30 showed the smallest particle size (157 ± 0.32 nm), Zeta-potential (-18 ± 0.01), and morphology by TEM analysis. The optimized formula was subsequently formulated into a sublingual tablet containing Pharma burst-V® with a shorter disintegration time (51s) for the in-vivo study. The selected sublingual tablet improved histological and biochemical markers (blood glucose, liver, and kidney function), AMP-activated protein kinase (AMPK), and protein kinase B (AKT) pathway compared to the market formula, increased CFZ's antidiabetic potency in diabetic rabbits, boosted bioavailability by five-fold, and produced faster onset of action. These findings suggest successful treatment of diabetes with CFZ nanocrystal-sublingual tablets.


Subject(s)
Diabetes Mellitus, Type 2 , Nanoparticles , Sodium-Glucose Transporter 2 Inhibitors , Animals , Rabbits , Canagliflozin , Tablets/chemistry , Solubility , Povidone/chemistry , Permeability , Nanoparticles/chemistry
7.
Microorganisms ; 11(5)2023 Apr 23.
Article in English | MEDLINE | ID: mdl-37317079

ABSTRACT

Fish is an excellent source of protein and other essential minerals and vitamins; nevertheless, several food-borne disease outbreaks have been linked to the consumption of different types of fish. Therefore, we aimed to overcome these health threats by evaluating gamma radiation as a good fish preservation method. The aerobic plate count (APC), identification of most common pathogenic bacteria, organoleptic properties, proximate composition, and other chemical evaluations were detected in both untreated and gamma-treated fish. The overall grades of organoleptic evaluations ranged from good to very good. Fortunately, the overall chemical analysis of all examined fish samples was accepted. For the untreated fish samples, the APC was within and above the permissible limit (5 × 107 CFU/g). Pathogenic bacteria were detected with a high prevalence rate, especially S. aureus, which was found in high percentages among examined untreated fish samples. Regarding the treated fish samples, APC and pathogenic bacterial counts were reduced in a dose-dependent manner, and the irradiation at dose 5 KGy resulted in complete eradication of the aerobic plate count (not detectable) with a mean reduction percentage equal to 100%. However, gamma irradiation has no significant effect on proximate composition; particularly, carbohydrates, proteins, and lipids were not significantly affected by low and medium doses of radiation. Therefore, gamma irradiation is a highly effective fish preservation method without any effect on fish quality. Additionally, gamma irradiation as a cold process is an attractive technology for solving the problem arising from fish-borne pathogens, and it has been purposed in this study as a cheap and safe method for reducing microbial contamination of fish.

8.
Br J Radiol ; 96(1150): 20220788, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37171811

ABSTRACT

OBJECTIVE: Leadless pacemakers (LPs) were designed to avoid complications associated with transvenous pacing. To minimise risk of perforations, there is preference towards implanting LPs into the septum rather than the apex or free wall.An objective yet feasible way of characterising the LP location is currently lacking. We report a simple radiological method of defining LP position and our analysis of the impact of implantation site on performance of LPs. METHODS: The first 100 LPs implanted at our UK centre were reviewed and the devices' positions in fluoroscopy images and X-rays based on conventional criteria for lead positions and conventional practice for LPs positioning were assessed. The devices' electrical parameters at implant and at the latest device follow-up were used to compare performance between implantation sites. RESULTS: 35.6% of implants were in the apex. 31.1% in mid-septum, 16.7% in apical septum, 15.5% on the septal right ventricular inflow and 1.1% in the septal RV outflow tract. We had no major complications.Thresholds, R-wave amplitudes, and impedance averaged at 0.67 ± 0.41 V, 10.64 ± 5.30 mV, and 777.67 ± 201.67 Ohms, respectively, at the time of implantation, and 0.66 ± 0.39 V, 14.08 ± 6.14 mV, and 564.29 ± 96.76 Ohms at the last device check. There was no difference in the pacing thresholds or impedance between implant sites. CONCLUSIONS: We propose a simple, reproducible way of defining the LP location which can help standardise the assessment of the device location sites across LP implantation centres. ADVANCES IN KNOWLEDGE: Emphasis on the safety and reliability of the leadless pacemakers in a real-world setting.Establishing the variation in the implantation sites for leadless pacemakers and reporting the effect of the implantation sites on the devices' performance.We propose a simple, reproducible way of defining the LP location which can help standardise the assessment of the device location sites across LP implantation centres.


Subject(s)
Pacemaker, Artificial , Humans , Reproducibility of Results , Lipopolysaccharides , Heart Ventricles , Fluoroscopy/methods , Equipment Design , Treatment Outcome
9.
Antibiotics (Basel) ; 12(3)2023 Feb 24.
Article in English | MEDLINE | ID: mdl-36978330

ABSTRACT

The worldwide crises from multi-drug-resistant (MDR) bacterial infections are pushing us to search for new alternative therapies. The renewed interest in medicinal plants has gained the attention of our research group. Tamarindus indica L. (T. indica) is one of the traditional medicines used for a wide range of diseases. Therefore, we evaluated the antimicrobial activities of ethanolic extract of T. indica. The inhibitions zones, minimum inhibitory concentration (MIC), minimum bactericidal concentration (MBC), and fractional inhibitor concentration indices (FICI) against Gram+ve and -ve pathogens were detected. The bioactive compounds from T. indica extract were identified by mass spectroscopy, thin-layer chromatography, and bio-autographic assay. We performed scanning electron microscopy (SEM) and molecular docking studies to confirm possible mechanisms of actions and antivirulence activities, respectively. We found more promising antimicrobial activities against MDR pathogens with MIC and MBC values for Staphylococcus aureus (S. aureus) and Pseudomonas aeruginosa (P. aeruginosa), i.e., (0.78, 3.12 mg/mL) and (1.56, 3.12 mg/mL), respectively. The antimicrobial activities of this extract were attributed to its capability to impair cell membrane permeability, inducing bacterial cell lysis, which was confirmed by the morphological changes observed under SEM. The synergistic interactions between this extract and commonly used antibiotics were confirmed (FICI values < 0.5). The bioactive compounds of this extract were bis (2-ethylhexyl)phthalate, phenol, 2,4-bis(1,1-dimethylethyl), 1,2-benzenedicarboxylic acid, and bis(8-methylnonyl) ester. Additionally, this extract showed antivirulence activities, especially against the S. aureus protease and P. aeruginosa elastase. In conclusion, we hope that pharmaceutical companies can utilize our findings to produce a new formulation of T. indica ethanolic extract with other antibiotics.

10.
Ann Noninvasive Electrocardiol ; 28(4): e13056, 2023 07.
Article in English | MEDLINE | ID: mdl-36920649

ABSTRACT

BACKGROUND: Machine learning methods are used in the classification of various cardiovascular diseases through ECG data analysis. The concept of varying subcutaneous implantable cardiac defibrillator (S-ICD) eligibility, owing to the dynamicity of ECG signals, has been introduced before. There are practical limitations to acquiring longer durations of ECG signals for S-ICD screening. This study explored the potential use of deep learning methods in S-ICD screening. METHODS: This was a retrospective study. A deep learning tool was used to provide descriptive analysis of the T:R ratios over 24 h recordings of S-ICD vectors. Spearman's rank correlation test was used to compare the results statistically to those of a "gold standard" S-ICD simulator. RESULTS: A total of 14 patients (mean age: 63.7 ± 5.2 years, 71.4% male) were recruited and 28 vectors were analyzed. Mean T:R, standard deviation of T:R, and favorable ratio time (FVR)-a new concept introduced in this study-for all vectors combined were 0.21 ± 0.11, 0.08 ± 0.04, and 79 ± 30%, respectively. There were statistically significant strong correlations between the outcomes of our novel tool and the S-ICD simulator (p < .001). CONCLUSION: Deep learning methods could provide a practical software solution to analyze data acquired for longer durations than current S-ICD screening practices. This could help select patients better suited for S-ICD therapy as well as guide vector selection in S-ICD eligible patients. Further work is needed before this could be translated into clinical practice.


Subject(s)
Deep Learning , Defibrillators, Implantable , Humans , Male , Middle Aged , Aged , Female , Death, Sudden, Cardiac/prevention & control , Electrocardiography/methods , Retrospective Studies , Heart
11.
Article in English | MEDLINE | ID: mdl-36652082

ABSTRACT

BACKGROUND: The subcutaneous ICD established its role in the prevention of sudden cardiac death in recent years. The occurrence of premature battery depletion in a large subset of potentially affected devices has been a cause of concern. The incidence of premature battery depletion has not been studied systematically beyond manufacturer-reported data. METHODS: Retrospective data and the most recent follow-up data on S-ICD devices from fourteen centers in Europe, the US, and Canada was studied. The incidence of generator removal or failure was reported to investigate the incidence of premature S-ICD battery depletion, defined as battery failure within 60 months or less. RESULTS: Data from 1054 devices was analyzed. Premature battery depletion occurred in 3.5% of potentially affected devices over an observation period of 49 months. CONCLUSIONS: The incidence of premature battery depletion of S-ICD potentially affected by a battery advisory was around 3.5% after 4 years in this study. Premature depletion occurred exclusively in devices under advisory. This is in line with the most recently published reports from the manufacturer. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04767516 .

12.
Ann Noninvasive Electrocardiol ; 28(1): e13028, 2023 01.
Article in English | MEDLINE | ID: mdl-36524869

ABSTRACT

INTRODUCTION: S-ICD eligibility is assessed at pre-implant screening where surface ECG traces are used as surrogates for S-ICD vectors. In heart failure (HF) patients undergoing diuresis, electrolytes and fluid shifts can cause changes in R and T waves. Subsequently, T:R ratio, a major predictor of S-ICD eligibility, can be dynamic. METHODS: This is a prospective study of patients with structurally normal hearts and HF patients undergoing diuresis. All patients were fitted with Holters® to record their S-ICD vectors. Our deep learning model was used to analyze the T:R ratios across the recordings. Welch two sample t-test and Mann-Whitney U were used to compare the data between the two groups. RESULTS: Twenty-one patients (age 58.43 ± 18.92, 62% male, 14 HF, 7 normal hearts) were enrolled. There was a significant difference in the T:R ratios between both groups. Mean T: R was higher in the HF group (0.18 ± 0.08 vs 0.10 ± 0.05, p < .001). Standard deviation of T: R was also higher in the HF group (0.09 ± 0.05 vs 0.07 ± 0.04, p = .024). There was no difference between leads within the same group. CONCLUSIONS: T:R ratio, a main determinant for S-ICD eligibility, is higher and has more tendency to fluctuate in HF patients undergoing diuresis. We hypothesize that our novel neural network model could be used to select HF patients eligible for S-ICD by better characterization of T:R ratio reducing the risk of T-wave over-sensing (TWO) and inappropriate shocks. Further work is required to consolidate our findings before applying to clinical practice.


Subject(s)
Deep Learning , Defibrillators, Implantable , Heart Failure , Humans , Male , Adult , Middle Aged , Aged , Female , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/etiology , Electrocardiography/methods , Prospective Studies , Arrhythmias, Cardiac/complications , Heart Failure/therapy , Heart Failure/complications
14.
Arrhythm Electrophysiol Rev ; 11: e19, 2022 Apr.
Article in English | MEDLINE | ID: mdl-36304202

ABSTRACT

Pacemakers are a key technology in the treatment of bradyarrhythmias. Leadless pacemakers (LP) were introduced to address limitations of transvenous devices. However, guidelines and other restrictions have led to LPs becoming niche products. The aim of this consensus statement was to determine the strength of opinion of UK implantation experts as to how LPs can be more optimally used. Using a modified Delphi approach, a panel of LP experts developed 36 statements that were used to form a survey that was distributed to LP implanters in the UK. Stopping criteria included a 3-month window for response, a minimum 25% response rate and at least 75% of statements achieving the threshold for consensus (agreed at 66%). In all, 31 of 36 statements reached consensus, and 23 of these achieved ≥90% agreement. Five statements did not achieve consensus. On the basis of these results, seven recommendations were proposed. The implementation of these recommendations may increase the use of LPs, with the aim of improving patient outcomes.

15.
Obes Surg ; 32(10): 3324-3331, 2022 10.
Article in English | MEDLINE | ID: mdl-35962269

ABSTRACT

BACKGROUND: Although laparoscopic gastric plication (LGP) has been mentioned in many studies, its practice has not yet been standardized. In addition, the outcomes remain conflicting, especially long-term ones. This study was conducted to elucidate the long-term consequences of LGP. METHODS: Retrospective analysis of patients with obesity underwent LGP at our institution between March 2010 and September 2014. Data were prospectively collected from our database. RESULTS: Of the 88 consecutive patients in the study period between 2010 and 2014, follow-up data out to 6 years was available in 60 LGP patients (68.18%). The mean age of the included patients was 41.3 ± 10 years. A total of 81.7% were females. We observed a significant BMI reduction out to 2 years (p < 0.001), a plateau at 3 and 4 years, and a significant BMI increase at 6 years (p < 0.01). %TWL at 2 years was 21.14% and 12.08% at 6 years. Weight regain was observed in 35 patients at 6 years to reach a rate of 58.3%. Predictors for weight regain at 6 years were disrupted plication fold, increased hunger, and non-adherence to regular exercise. The diabetes improvement rate was 66.6% at 6 years. There were 14 re-operations (23.3%): 1 emergency (1.6%) and 13 (21.6%) elective. There was no mortality. CONCLUSION: At the 6-year follow-up visit, LGP has a much less durable effect on weight loss with a % EWL of 32% and a weight regain of 58.3% resulting in a high rate of revisions.


Subject(s)
Gastroplasty , Laparoscopy , Obesity, Morbid , Adult , Body Mass Index , Female , Gastrectomy/methods , Humans , Laparoscopy/methods , Male , Middle Aged , Obesity, Morbid/surgery , Postoperative Complications/surgery , Retrospective Studies , Treatment Outcome , Weight Gain
16.
Pacing Clin Electrophysiol ; 45(7): 874-884, 2022 07.
Article in English | MEDLINE | ID: mdl-35691000

ABSTRACT

BACKGROUND: Guidelines recommend that cardiac pacing should be considered in patients suffering from frequent vasovagal syncopal (VVS) episodes. Studies have demonstrated the safety and efficacy of leadless pacemakers (LP) in cardioinhibitory vasovagal populations specifically, rendering them a reasonable alternative to transvenous pacing in these patients. However, due to the paucity of data on extraction and the number of concomitant LPs that can be safely implanted, there are concerns regarding LPs' battery longevity, especially in younger patients who may require decades of pacing therapy. METHODS: This is a retrospective analysis of the first 100 LPs implanted at a tertiary cardiac centre in the UK. Demographical data and device parameters at implant and follow-ups were obtained from the hospital's medical records. The battery life of the LPs in the VVS patients was compared to that of patients with other pacing indications. RESULTS: Ninety patients were included in the analysis. 14 patients (15.6%) had VVS, and 76 patients (84.4%) had other indications for pacing. Mean ages were 34 ± 13 years and 62 ± 20 years for the VVS and the other group, respectively. The estimated total battery life was 15.22 ± 0.35 and 13.65 ± 2.97 years in the VVS and the other indications group respectively (p = .04). There were no complications in the VVS group. CONCLUSION: LPs provide a promising treatment for patients with vasovagal syncope with reassuring battery performance at the short/intermediate term. Further longer-term follow-up data are needed to identify the true battery potential in this patient cohort.


Subject(s)
Pacemaker, Artificial , Syncope, Vasovagal , Adult , Cardiac Pacing, Artificial/adverse effects , Humans , Lipopolysaccharides , Middle Aged , Pacemaker, Artificial/adverse effects , Retrospective Studies , Syncope/therapy , Syncope, Vasovagal/etiology , Syncope, Vasovagal/therapy , Young Adult
17.
Article in English | MEDLINE | ID: mdl-35551558

ABSTRACT

BACKGROUND: A major predictor of eligibility of subcutaneous implantable cardiac defibrillators (S-ICD) is the T:R ratio. The eligibility cut-off of the T:R ratio incorporates a safety margin to accommodate for fluctuations of ECG signal amplitudes. We introduce a deep learning-based tool that accurately measures the degree of T:R ratio fluctuations and explore its role in S-ICD screening. METHODS: Patients were fitted with Holters for 24 h to record their S-ICD vectors. Our tool was used to assess the T:R ratio over the duration of the recordings. Multiple T:R ratio cut-off values were applied, identifying patients at high risk of T-wave oversensing (TWO) at each of the proposed values. The purpose of our study is to identify the ratio that recognises patients at high risk of TWO while not inappropriately excluding true S-ICD candidates. RESULTS: Thirty-seven patients (age 54.5 + / - 21.3 years, 64.8% male) were recruited. Fourteen patients had heart-failure, 7 hypertrophic cardiomyopathy, 7 had normal hearts, 6 had congenital heart disease, and 3 had prior inappropriate S-ICD shocks due to TWO. 54% of patients passed the screening at a T: R of 1:3. All patients passed the screening at a T: R of 1:1. The only subgroup to wholly pass the screening utilising all the proposed ratios are the participants with normal hearts. CONCLUSION: We propose adopting prolonged screening to select patients eligible for S-ICD with low probability of TWO and inappropriate shocks. The appropriate T:R ratio likely lies between 1:3 and 1:1. Further studies are required to identify the optimal screening thresholds.

18.
Obes Surg ; 32(8): 2537-2547, 2022 08.
Article in English | MEDLINE | ID: mdl-35596915

ABSTRACT

PURPOSE: Prediction of the onset of de novo gastroesophageal reflux disease (GERD) after sleeve gastrectomy (SG) would be helpful in decision-making and selection of the optimal bariatric procedure for every patient. The present study aimed to develop an artificial intelligence (AI)-based model to predict the onset of GERD after SG to help clinicians and surgeons in decision-making. MATERIALS AND METHODS: A prospectively maintained database of patients with severe obesity who underwent SG was used for the development of the AI model using all the available data points. The dataset was arbitrarily split into two parts: 70% for training and 30% for testing. Then ranking of the variables was performed in two steps. Different learning algorithms were used, and the best model that showed maximum performance was selected for the further steps of machine learning. A multitask AI platform was used to determine the cutoff points for the top numerical predictors of GERD. RESULTS: In total, 441 patients (76.2% female) of a mean age of 43.7 ± 10 years were included. The ensemble model outperformed the other models. The model achieved an AUC of 0.93 (95%CI 0.88-0.99), sensitivity of 79.2% (95% CI 57.9-92.9%), and specificity of 86.1% (95%CI 70.5-95.3%). The top five ranked predictors were age, weight, preoperative GERD, size of orogastric tube, and distance of first stapler firing from the pylorus. CONCLUSION: An AI-based model for the prediction of GERD after SG was developed. The model had excellent accuracy, yet a moderate sensitivity and specificity. Further prospective multicenter trials are needed to externally validate the model developed.


Subject(s)
Gastroesophageal Reflux , Laparoscopy , Obesity, Morbid , Adult , Artificial Intelligence , Female , Gastrectomy/adverse effects , Gastrectomy/methods , Gastroesophageal Reflux/diagnosis , Gastroesophageal Reflux/etiology , Gastroesophageal Reflux/surgery , Humans , Laparoscopy/methods , Male , Middle Aged , Obesity, Morbid/surgery
19.
Article in English | MEDLINE | ID: mdl-35460502

ABSTRACT

BACKGROUND: Patients with an existing subcutaneous implantable cardiac defibrillator (S-ICD) may develop a pacing indication. When transvenous pacing is not feasible, combining an S-ICD and a leadless pacemaker (LP) can be a reasonable option. There are reports of concomitant use of both devices. However, the effect of pacing on the S-ICD sensing is not well studied. We hypothesise that pacing changes R and T-wave amplitudes, causing changes in R:T ratios as perceived by a S-ICD, increasing the risk for T wave oversensing (TWO) during paced rhythm with a subsequent risk of inappropriate shocks. METHODS: This is a prospective study in patients undergoing electrophysiological studies. Participants were fitted with a Holter®, and the leads were placed to correspond to the vectors of an S-ICD. The right ventricle was paced at four positions for 10 beats each at 8 mA/2 ms. The Holter® traces were analysed, using two-way analysis of variance (ANOVA) to assess the effect of pacing on the R:T ratio. RESULTS: Forty-seven patients (age 56.02 ± 16.02, 72% male) were enrolled (81% structurally normal heart, 15% dilated cardiomyopathy, 2% ischaemic cardiomyopathy, and 2% adult congenital heart disease). Age, sex, and aetiology had no effect on the R:T ratio. Pacing caused significant changes in the R:T ratio. There was no significant difference in the R:T ratios between the pacing sites (p < 0.001). CONCLUSIONS: Pacing alters the R:T ratio significantly in most patients, theoretically increasing the risk for TWO and inappropriate shocks. Tailored programming for both devices is important for concomitant use of LPs and S-ICDs.

20.
J Electrocardiol ; 72: 21-27, 2022.
Article in English | MEDLINE | ID: mdl-35247804

ABSTRACT

INTRODUCTION: Haemodialysis patients who require defibrillator therapy are expected to benefit from the entirely avascular subcutaneous defibrillator (S-ICD), but haemodialysis is associated with dynamic changes in R and T wave amplitude which can impact S-ICD eligibility. A continuous assessment of S-ICD eligibility during haemodialysis has not previously been performed. MATERIAL AND METHODS: Continuous surface ECG recordings were obtained from a cohort of patients undergoing maintenance haemodialysis, but without an indication for an ICD. Automated vector screening was retrospectively performed at one-minute intervals throughout the dialysis session. Variations in S-ICD eligibility were calculated and in vectors with high degrees of variation, the underlying mechanism was identified. RESULTS: 72 vector recordings (mean duration 254.1 ± 6.0 min) were obtained from 24 patients (mean age 64.3 ± 5.5 years, 68% male). At the start of haemodialysis 47 vectors were S-ICD eligible (65.2%). At the end of session, all of these vectors had remained eligible, and an additional 6 vectors had also become eligible (73.6%). High vector score variability was observed in 7 patients and the commonest cause was a progressive change in R:T ratio (71.5%). CONCLUSION: In a haemodialysis population, a single haemodialysis session can be associated with a potential change in S-ICD eligibility in 8.4% of vectors, with up to 12.5% of vectors showing high degrees of variability, most commonly due to variations in R:T ratio. In an S-ICD population with similar characteristics S-ICD screening prior to haemodialysis would be expected to more accurately identify vectors that retain eligibility.


Subject(s)
Defibrillators, Implantable , Aged , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Electrocardiography , Female , Humans , Male , Middle Aged , Renal Dialysis/adverse effects , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...