Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 175
Filter
1.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Article in English | MEDLINE | ID: mdl-38717086

ABSTRACT

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Subject(s)
Cornea , Elasticity , Intraocular Pressure , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Humans , Cornea/physiopathology , Cornea/surgery , Adult , Female , Male , Biomechanical Phenomena , Lasers, Excimer/therapeutic use , Keratomileusis, Laser In Situ/methods , Young Adult , Elasticity/physiology , Myopia/surgery , Myopia/physiopathology , Intraocular Pressure/physiology , Photorefractive Keratectomy/methods , Visual Acuity/physiology , Refraction, Ocular/physiology , Middle Aged , Prospective Studies , Corneal Surgery, Laser/methods , Corneal Topography
2.
Front Bioeng Biotechnol ; 12: 1323612, 2024.
Article in English | MEDLINE | ID: mdl-38558790

ABSTRACT

Purpose: To evaluate the change in corneal biomechanics in patients with postoperative ectasia risk when combining two common laser vision correction procedures (tPRK and FS-LASIK) with cross-linking (in tPRK Xtra and FS-LASIK Xtra). Methods: The study included 143 eyes of 143 myopic, astigmatic patients that were divided into non-cross-linked refractive surgery groups (non-Xtra groups, tPRK and FS-LASIK) and cross-linked groups (Xtra groups, tPRK Xtra and FS-LASIK Xtra) according to an ectasia risk scoring system. The eyes were subjected to measurements including the stress-strain index (SSI), the stiffness parameter at first applanation (SP-A1), the integrated inverse radius (IIR), the deformation amplitude at apex (DA), and the ratio of deformation amplitude between apex and 2 mm from apex (DARatio2mm). The measurements were taken preoperatively and at 1, 3, and 6 months postoperatively (pos1m, pos3m, and pos6m). Posterior demarcation line depth from the endothelium (PDLD) and from the ablation surface (DLA) were recorded at pos1m. Results: SP-A1 significantly decreased, while IIR, deformation amplitude, and DARatio2mm increased significantly postoperatively in all four groups (p < 0.01)-all denoting stiffness decreases. In the FS-LASIK group, the changes in IIR, DA, and DARatio2mm were 32.7 ± 15.1%, 12.9 ± 7.1%, and 27.2 ± 12.0% respectively, which were significantly higher (p < 0.05) compared to 20.1 ± 12.8%, 6.4 ± 8.2%, and 19.7 ± 10.4% in the FS-LASIK Xtra group. In the tPRK group, the change in IIR was 27.3 ± 15.5%, significantly larger than 16.9 ± 13.4% in the tPRK Xtra group. The changes of SSI were minimal in the tPRK (-1.5 ± 21.7%, p = 1.000), tPRK Xtra (8.4 ± 17.9%, p = 0.053), and FS-LASIK Xtra (5.6 ± 12.7%, p = 0.634) groups, but was significant in the FS-LASIK group (-12.1 ± 7.9%, p < 0.01). After correcting for baseline biomechanical metrics, preoperative bIOP and the change in central corneal thickness (△CCT) from pre to pos6m, the changes in the IIR in both FS-LASIK and tPRK groups, as well as DA, DARatio2mm and SSI in the FS-LASIK group remained statistically greater than their corresponding Xtra groups (all p < 0.05). Most importantly, after correcting for these covariates, the changes in DARatio2mm in the FS-LASIK Xtra became statistically smaller than in the tPRK Xtra (p = 0.017). Conclusion: The statistical analysis results indicate that tPRK Xtra and FS-LASIK Xtra effectively reduced the biomechanical losses caused by refractive surgery (tPRK and FS-LASIK). The decrease in corneal overall stiffness was greater in FS-LASIK than in tPRK, and the biomechanical enhancement of CXL was also higher following LASIK than after tPRK.

4.
Virchows Arch ; 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38355738

ABSTRACT

DICER1 tumor predisposition syndrome is a pleiotropic disorder that gives rise to various mainly pediatric-onset lesions. We report an extraskeletal chondroma (EC) of the great toe occurring in a child who, unusually, carries a germline "hotspot" missense DICER1 variant rather than the more usual loss-of-function (LOF) variant. No heterozygous LOF allele was identified in the EC. We demonstrate this variant impairs 5p cleavage of precursor-miRNA (pre-miRNA) and competes with wild-type (WT) DICER1 protein for pre-miRNA processing. These results suggest a mechanism through which a germline RNase IIIb variant could impair pre-miRNA processing without complete LOF of the WT DICER1 allele.

5.
BMC Psychol ; 12(1): 48, 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38273390

ABSTRACT

BACKGROUND: SARS-CoV-2 pandemic has had many significant impacts within the surgical realm, and surgeons have been obligated to reconsider almost every aspect of daily clinical practice. METHODS: This is a cross-sectional study reported in compliance with the CHERRIES guidelines and conducted through an online platform from June 14th to July 15th, 2020. The primary outcome was the burden of burnout during the pandemic indicated by the validated Shirom-Melamed Burnout Measure. RESULTS: Nine hundred fifty-four surgeons completed the survey. The median length of practice was 10 years; 78.2% included were male with a median age of 37 years old, 39.5% were consultants, 68.9% were general surgeons, and 55.7% were affiliated with an academic institution. Overall, there was a significant increase in the mean burnout score during the pandemic; longer years of practice and older age were significantly associated with less burnout. There were significant reductions in the median number of outpatient visits, operated cases, on-call hours, emergency visits, and research work, so, 48.2% of respondents felt that the training resources were insufficient. The majority (81.3%) of respondents reported that their hospitals were included in the management of COVID-19, 66.5% felt their roles had been minimized; 41% were asked to assist in non-surgical medical practices, and 37.6% of respondents were included in COVID-19 management. CONCLUSIONS: There was a significant burnout among trainees. Almost all aspects of clinical and research activities were affected with a significant reduction in the volume of research, outpatient clinic visits, surgical procedures, on-call hours, and emergency cases hindering the training. TRIAL REGISTRATION: The study was registered on clicaltrials.gov "NCT04433286" on 16/06/2020.


Subject(s)
Burnout, Professional , COVID-19 , Surgeons , Adult , Female , Humans , Male , Burnout, Professional/epidemiology , COVID-19/epidemiology , Cross-Sectional Studies , Pandemics , SARS-CoV-2 , Surveys and Questionnaires , Middle Aged
6.
Acta Biomater ; 176: 304-320, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38296013

ABSTRACT

The contact and pull-off tests and finite element simulations were used to study the extraocular muscle-sclera adhesion and its variation with eye movement in this research. The effect of the adhesion on the eye movements was also determined using equilibrium equations of eye motion. The contact and pull-off tests were performed using quasi-static and non-quasi-static unloading velocities. Finite element models were developed to simulate these tests in cases with high unloading velocity which could not be achieved experimentally. These velocities range from the eye's fixation to saccade movement. The tests confirmed that the pull-off force is related to the unloading velocity. As the unloading velocity increases, the pull-off force increases, with an insignificant increase at the high ocular saccade velocities. The adhesion moment between the extraocular muscles and the sclera exhibited the same trend, increasing with higher eye movement velocities and higher separation angles between the two interfaces. The adhesion moment ratio to the total moment was calculated by the traditional model and the active pulley model of eye movements to assess the effect of adhesion behavior on eye movements. At the high ocular saccade velocities (about 461 deg/s), the adhesion moment was found to be 0.53% and 0.50% of the total moment based on the traditional and active pulley models, respectively. The results suggest that the adhesion behavior between the extraocular muscles and the sclera has a negligible effect on eye movements. At the same time, this adhesion behavior can be ignored in eye modeling, which simplifies the model reasonably well. STATEMENT OF SIGNIFICANCE: 1. Adhesion behavior between the extraocular muscles and the sclera at different indenter unloading velocities determined by contact and pull-off tests. 2. A finite element model was developed to simulate the adhesive contact between the extraocular muscles and the sclera at different indenter unloading velocities. The bilinear cohesive zone model was used for adhesive interactions. 3. The elastic modulus and viscoelastic parameters of the extraocular muscle along the thickness direction were obtained by using compressive stress-relaxation tests. 4. The influence of the adhesion moment between the extraocular muscles and the sclera on eye movement was obtained according to the equation of oculomotor balance. The adhesion moment between the extraocular muscles and the sclera was found to increase with increased eye movement velocity and increased separation angle between the two interfaces.


Subject(s)
Eye Movements , Oculomotor Muscles , Oculomotor Muscles/physiology , Movement , Face , Physical Phenomena
7.
Cont Lens Anterior Eye ; 47(1): 102100, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38072740

ABSTRACT

PURPOSE: To investigate the alterations in corneal biomechanical metrics induced by orthokeratology (ortho-k) using Corvis ST and to determine the factors influencing these changes. METHOD: A prospective observational study was conducted to analyze various Corvis ST parameters in 32 children with low to moderate myopia who successfully underwent ortho-k lens fitting. Corneal biomechanical measurements via Corvis ST were acquired at six distinct time points: baseline (pre) and 2 h (pos2h), 6 h (pos6h), and 10 h (pos10h) following the removal of the first overnight wear ortho-k, one week (pos1w) and one month (pos1m) subsequent to the initiation of ortho-k. RESULT: Significant differences were observed in Corvis ST Biomechanical parameters DAR2, IIR, CBI, and cCBI post ortho-k intervention. The integration of covariates (CCT, SimK, and bIOP) mitigated the differences in DAR2, IIR, and cCBI, but not in CBI. Initially, the stiffness parameter at first applanation, SP-A1, did not demonstrate significant variations, but after adjusting for covariates, noticeable differences over time were observed. The Stress-Strain Indeces, SSIv1 and SSIv2, did not manifest considerable changes over time, irrespective of the adjustment for covariates. No significant disparities were identified among different ortho-k lens brands. CONCLUSION: Corneal biomechanics remained consistent throughout the one-month period of ortho-k lens wear. The observed changes in Corvis ST parameters subsequent ortho-k are primarily attributable to alterations in corneal pachymetry and morphology, rather than actual alterations in corneal biomechanics. The stability of corneal biomechanics post ortho-k treatment suggests the safety of this approach for adolescents from a corneal biomechanics perspective.


Subject(s)
Cornea , Tonometry, Ocular , Adolescent , Child , Humans , Biomechanical Phenomena , Corneal Pachymetry , Corneal Topography
8.
Clin Exp Pediatr ; 67(4): 178-190, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37350171

ABSTRACT

Cardiac failure is a clinical syndrome that may develop in children owing to cardiac dysfunction or underlying structural heart diseases. Considering the differences in diagnostic and therapeutic approaches for pediatric heart failure (PHF) and adult heart failure, we have reviewed the current literature on PHF. Relevant studies were extracted from MEDLINE/PubMed, Google Scholar, and Clinical Trial Registries using the terms "pediatric heart failure" or "heart failure in children" and "management" or "decongestive therapy." Recent advances in diagnostic approaches, such as cardiac magnetic resonance, speckle-tracking echocardiography, tissue Doppler imaging, and molecular diagnostic techniques, have increased our under -standing of PHF. It is imperative that clinicians evaluate the interrelated factors responsible for the develop ment of PHF, including myocardial function, pulmonary and systemic blood flow, heart rhythm, valve function, and nutritional status. Although recent advances have demon strated the efficacy of many new drugs in adult heart failure trials, it cannot be concluded that these drugs will show similar efficacy in children, considering the heterogeneous nature of the underlying mechanisms and variable pharmacody-namics and pharmacokinetics. Therefore, the underlying pathophysiology of PHF and the mechanisms of action of different drugs should be considered when selecting appropriate therapies. Further trials are needed to establi sh the efficacy and safety of these drugs, and a combined mul-ti disciplinary strategy will help enhance PHF outcomes.

9.
Prosthet Orthot Int ; 48(2): 149-157, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38019004

ABSTRACT

BACKGROUND OBJECTIVE: The purpose of this study was to evaluate prosthetic outcome in patients with severe congenital femoral deficiency and the potential benefits of surgical intervention on prosthetic fitting and gait. METHODS: A retrospective review identified 26 active case records with a proximal femoral focal deficiency using a prosthesis. Validated outcome measures evaluated comfort, function, and prosthetic use and quality-of-life assessment. Outcome compared age groups and surgical intervention. Gait analysis performed in 7 patients further evaluated hip and knee function. RESULTS: Eleven male patients and 15 female patients, including 13 children (mean age 10 years, range 5-16) and 13 adults (mean age 36 years, range 23-63) were evaluated. Better prosthetic function and PedsQL scores were recorded in the pediatric group. There was a trend for better scores after surgery. Gait analysis demonstrated reduced hip extension compensated by knee flexion in 3 patients, 2 patients had hip extension with near normal kinematics, 1 untreated patient walked with an unsteady gait, and the remaining walked well using an ischial-bearing prosthesis with pelvic compensatory movements. CONCLUSION: The management strategy in severe proximal femoral focal deficiency remains a major challenge. Hip reconstruction seems to improve functional scores. Overall, the scores seem to decline into adulthood but not significantly. Gait analysis before further surgical intervention is recommended because compensatory knee flexion may improve step length in terminal stance. Limited numbers, with short follow-up, prevents clear guidance on the benefit of surgery.


Subject(s)
Femur , Gait , Adult , Humans , Male , Female , Child , Child, Preschool , Adolescent , Femur/surgery , Walking , Retrospective Studies , Leg , Biomechanical Phenomena , Range of Motion, Articular
10.
Am J Ophthalmol ; 258: 196-207, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37879454

ABSTRACT

PURPOSE: This study seeks to evaluate the ability of the updated stress strain index (SSIv2) and other Corvis ST biomechanical parameters in distinguishing between keratoconus at different disease stages and normal eyes. DESIGN: Diagnostic accuracy analysis to distinguish disease stages. METHODS: 1084 eyes were included and divided into groups of normal (199 eyes), forme fruste keratoconus (FFKC, 194 eyes), subclinical keratoconus (SKC, 113 eyes), mild clinical keratoconus (CKC-Ⅰ, 175 eyes), moderate clinical keratoconus (CKC-Ⅱ, 204 eyes), and severe clinical keratoconus (CKC-Ⅲ, 199 eyes). Each eye was subjected to a Corvis ST examination to determine the central corneal thickness (CCT), biomechanically corrected intraocular pressure (bIOP), SSIv2 (updated stress-strain index), and other 8 Corvis parameters including the stress-strain index (SSIv1), stiffness parameter at first applanation (SP-A1), first applanation time (A1T), Ambrósio relational thickness to the horizontal profile (ARTh), integrated inverse radius (IIR), maximum deformation amplitude (DAM), ratio between deformation amplitude at the apex and at 2 mm nasal and temporal (DARatio2), and Corvis biomechanical index (CBI). The sensitivity and specificity of these parameters in diagnosing keratoconus were analyzed through receiver operating characteristic curves. RESULTS: Before and after correction for CCT and bIOP, SSIv2 and ARTh were significantly higher and IIR and CBI were significantly lower in the normal group than in the FFKC group, SKC group and the 3 CKC groups (all P < .05). There were also significant correlations between the values of SSIv2, ARTh, IIR, CBI, and the CKC severity (all P < .05). AUC of SSIv2 was significantly higher than all other Corvis parameters in distinguishing normal eyes from FFKC, followed by IIR, ARTh and CBI. CONCLUSION: Corvis ST's updated stress-strain index, SSIv2, demonstrated superior performance in differentiating between normal and keratoconic corneas, and between corneas with different keratoconus stages. Similar, but less pronounced, performance was demonstrated by the IIR, ARTh and CBI.


Subject(s)
Keratoconus , Humans , Keratoconus/diagnosis , Corneal Topography , Cornea , Tonometry, Ocular , Intraocular Pressure , ROC Curve , Biomechanical Phenomena
11.
J Cataract Refract Surg ; 49(12): 1258-1263, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37982775

ABSTRACT

PURPOSE: To evaluate the 1-year effects of the implantation of intrastromal corneal ring segments (ICRS) in keratoconus (KC) on the dynamic corneal response (DCR) parameters obtained with the Corvis. SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. DESIGN: Prospective, single-center, clinical study. METHODS: Included were patients who underwent ICRS implantation for KC over a period of 1 year. On the day of the surgery and at least 6 months after ICRS implantation, the following measurements were made: corrected distance and uncorrected distance visual acuity, corneal tomography indices with the Pentacam, biomechanically corrected intraocular pressure and the Corvis DCRs (integrated inverse concave radius, deformation amplitude ratio, stiffness parameter at first applanation, stress-strain index [SSI] and the highest concavity radius). RESULTS: 30 eyes were included with a mean follow-up time of 15 months. Statistical analysis showed that ICRS implantation induced significant improvements in corneal biomechanics measurements between preoperative and long-term follow-up as demonstrated by a significant increase in SSI (P = .003). To confirm that this difference was actually induced due to a stiffening between early postoperative (previously published) and long-term an additional t-test was done between month 1 and late follow-up which confirmed a significant stiffening in the value of SSI (P = .01). CONCLUSIONS: Patients implanted with ICRS alone for KC showed a significantly stiffer response due to increased structural support compared with preoperative values and 1 month postoperative.


Subject(s)
Keratoconus , Humans , Keratoconus/surgery , Biomechanical Phenomena , Prospective Studies , Cornea/surgery , Academies and Institutes
12.
Invest Ophthalmol Vis Sci ; 64(13): 26, 2023 10 03.
Article in English | MEDLINE | ID: mdl-37850947

ABSTRACT

Purpose: To evaluate the regional effects of different corneal cross-linking (CXL) protocols on corneal biomechanical properties. Methods: The study involved both eyes of 50 rabbits, and the left eyes were randomized to the five intervention groups, which included the standard CXL group (SCXL), which was exposed to 3-mW/cm2 irradiation, and three accelerated CXL groups (ACXL1-3), which were exposed to ultraviolet-A at irradiations of 9 mW/cm2, 18 mW/cm2, and 30 mW/cm2, respectively, but with the same total dose (5.4 J/cm2). A control (CO) group was not exposed to ultraviolet-A. No surgery was done on the contralateral eyes. The corneas of each group were evaluated by the effective elastic modulus (Eeff) and the hydraulic conductivity (K) within a 7.5-mm radius using nanoindentation measurements. Results: Compared with the CO group, Eeff (in regions with radii of 0-1.5 mm, 1.5-3.0 mm, and 3.0-4.5 mm) significantly increased by 309%, 276%, and 226%, respectively, with SCXL; by 222%, 209%, and 173%, respectively, with ACXL1; by 111%, 109%, and 94%, respectively, with ACXL2; and by 59%, 41%, and 37%, respectively, with ACXL3 (all P < 0.05). K was also significantly reduced by 84%, 81%, and 78%, respectively, with SCXL; by 75%, 74%, and 70%, respectively, with ACXL1; by 64%, 62%, and 61%, respectively, with ACXL2; and by 33%, 36%, and 32%, respectively, with ACXL3 (all P < 0.05). For the other regions(with radii between 4.5 and 7.5 mm), the SCXL and ACXL1 groups (but not the ACXL2 and ACXL3 groups) still showed significant changes in Eeff and K. Conclusions: CXL had a significant effect on corneal biomechanics in both standard and accelerated procedures that may go beyond the irradiated area. The effect of CXL in stiffening the tissue and reducing permeability consistently decreased with reducing the irradiance duration.


Subject(s)
Ultraviolet Rays , Animals , Rabbits , Biomechanical Phenomena , Cornea , Corneal Cross-Linking , Corneal Stroma , Cross-Linking Reagents/pharmacology , Elastic Modulus , Photosensitizing Agents/pharmacology , Photosensitizing Agents/therapeutic use
13.
J Orthop Surg Res ; 18(1): 768, 2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37817247

ABSTRACT

INTRODUCTION: Miserable malalignment syndrome is a complex torsional lower limb deformity with limited consensus on surgical treatment. We present the outcome of de-rotation of the tibia alone using an external fixator. METHODS: Fifteen patients (22 segments) were operated on between 2012 and 2020; 13 presented with anterior knee pain, and two presented with out-toeing. Gait analysis was done in nine patients, and CT scan rotational profile, including tibial tubercle-trochlear groove distance, femoral version, and tibial torsion, were calculated. Kujala knee pain score and visual analogue pain score (VAS) were recorded. All underwent infra-tubercular osteotomy of the tibia and midshaft osteotmy of the fibula and application of a hexapod circular frame to gradually internally rotate the tibia until the foot aligned with the patella. RESULTS: There was no preoperative clinical or radiographic evidence for patellar instability, femoral anteversion 30° (21°-54°), and external tibial torsion 50° (37-70). The mean age at surgery was 21 years (12-37) with a mean follow-up of 20 months (9-83). All osteotomies healed, and the frames were removed at a mean of 111 days (80-168). The mean VAS score improved from 8(5-9) to 1(0-4) postoperatively (P < 0.001). The mean Kujala knee pain score increased from 53 (30-75) to 92 (54-100) postoperatively (P < 0.001). The mean preoperative foot progression angle (FPA) was 37° (20°-50°), with 13 postoperatively walking with neutral FPA. One patient walked with symmetrical + 10° and the other with - 5° FPA. All patients reported relief of knee pain and were satisfied with the alignment. CONCLUSION: Gradual correction of severe external tibia torsion with a hexapod external fixator and an infra-tubercle tibial osteotomy could provide an optimum method to eliminate knee pain and improve limb alignment in miserable malalignment syndrome.


Subject(s)
Joint Instability , Patellofemoral Joint , Humans , Child , Adolescent , Young Adult , Adult , Joint Instability/surgery , Patellofemoral Joint/surgery , Retrospective Studies , Knee Joint/diagnostic imaging , Knee Joint/surgery , Tibia/diagnostic imaging , Tibia/surgery , Lower Extremity , Osteotomy/methods , Syndrome
14.
Prz Menopauzalny ; 22(3): 121-125, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37829269

ABSTRACT

Introduction: The goal of this study is to evaluate the effectiveness of single-incision mini-sling in the surgical treatment of postmenopausal urodynamic stress urinary incontinence (SUI) compared to the standard trans-obturator mid-urethral sling. Material and methods: This prospective study was carried out in two tertiary centres; Al-Azhar University Maternity & Urology Hospitals. A total of 120 postmenopausal women with urodynamic SUI were randomized to undergo either single-incision mini-sling (n = 60) or standard trans-obturator mid-urethral sling procedure (n = 60) from May 2019 until Oct 2021. Main outcome measures: efficacy was evaluated utilizing objective cure rate (cough stress test) and subjective cure rate (Sandvik incontinence severity index and International Consultations on Incontinence Questionnaire - Short Form), intraoperative and postoperative complications, and postoperative pain (using a visual analogue scale). Results: The single-incision mini-sling (SIMS) and transobturator tape (TOT) groups had no statistically significant difference in subjective and objective cure rates (p > 0.05). Compared with the transvaginal tape O group, patients in the SIMS group had significantly less postoperative pain, shorter operative duration, and less intraoperative blood loss (all p-values < 0.05). No significant difference in perioperative complications was observed between both groups. Conclusions: Single-incision mini-sling was superior to TOT in postmenopausal as SIMS is of similar effectiveness, more safe and minimally invasive with earlier ambulance.

15.
Int Ophthalmol ; 43(11): 4289-4295, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37644351

ABSTRACT

PURPOSE: The Corvis Biomechanical Index-Laser Vision Correction (CBI-LVC) is a biomechanical index to detect ectasia in post-refractive surgery patients (PRK, LASIK, SMILE). This study aims to evaluate the distribution of the CBI-LVC in stable patients who underwent Phototherapeutic Keratectomy (PTK) compared to PRK patients. METHODS: Patients who underwent PRK and PTK performed between 2000 and 2018 in Humanitas Research Hospital, Rozzano, Milan, Italy and remained stable for at least four years post-surgery were included. All eyes were examined with the Corvis ST (Oculus, Germany), whose output allows the calculation of the CBI-LVC. The distribution and specificity of the CBI-LVC in the two populations were estimated using a Wilcoxon Mann-Whitney test and compared. RESULTS: 175 eyes of 148 patients were included (85 eyes of 50 PTK patients and 90 eyes of 90 PRK patients). The distribution of CBI-LVC in the two groups showed a minor difference, with a median value in PRK patients of 0.000 (95% CI 0.000; 0.002) and 0.008 (95% CI 0.000; 0.037) in PTK patients (Mann-Whitney U test p = 0.023). The statistical analysis showed that the CBI-LVC provided a specificity of 92.22% in the PRK group, while in the PTK group it was 82.35%. Nevertheless, this difference was not statistically significant (Chi-squared test with Yates, p = 0.080). CONCLUSION: CBI-LVC provided similar specificity in stable PTK patients compared to those who underwent PRK. These results suggest that the CBI-LVC could be a useful tool to aid corneal surgeons in managing PTK patients.


Subject(s)
Keratomileusis, Laser In Situ , Photorefractive Keratectomy , Surgeons , Humans , Cornea/surgery , Lasers
16.
Front Bioeng Biotechnol ; 11: 1146828, 2023.
Article in English | MEDLINE | ID: mdl-37492801

ABSTRACT

To estimate the material stiffness of the orbital soft tissue in human orbits using an inverse numerical analysis approach, which could be used in future studies to understand the behaviour under dynamic, non-contact tonometry or simulate various ophthalmological conditions. Clinical data were obtained for the left eye of 185 Chinese participants subjected to a complete ophthalmic examination, including tests by the Corvis ST and Pentacam. 185 numerical models of the eye globes were built with idealised geometry of the sclera while considering the corneal tomography measured by the Pentacam. The models were extended to include representations of the orbital soft tissue (OST), which were given idealised geometry. The movement of the whole eye in response to an air-puff directed at the central cornea was examined and used in an inverse analysis process to estimate the biomechanical stiffness parameters of the OST. The results indicated a weak correlation of E t with the progression of age, regardless of the stress at which E t was calculated. However, there was evidence of significant differences in E t between some of the age groups. There was statistical evidence of significant differences between E t in the age range 20< years < 43 relative to E t in OST with age ranges 43< years < 63 (p = 0.022) and 63< years < 91 (p = 0.011). In contrast, E t in OST with age ranges 43< years < 63 and 63< years < 91 were not significantly different (p = 0.863). The optimised mechanical properties of the OST were found to be almost four times stiffer than properties of fatty tissue of previous experimental work. This study consolidated previous findings of the role of extraocular muscles on the ocular suppor system. In addition, the rotation of the globe during corvis loading is suggested to be of posterior components of the globe and shall be further investigated.

17.
Exp Eye Res ; 233: 109552, 2023 08.
Article in English | MEDLINE | ID: mdl-37356538

ABSTRACT

PURPOSE: This study aimed to perform an in vitro experiment to simulate retinal detachment caused by blunt impact, and provide experimental evidence to understand mechanical causes of traumatic retinal detachment. METHODS: The experiment was conducted on twenty-two fresh porcine eyes using a bespoke pendulum testing device at two energy levels (0.1J for low energy and 1.0J for high energy). We examined dynamic forces and mechanical responses to the impact, including global deformations, intraocular pressure changes and the energy absorption. Another set of twenty-two eyes underwent pathological examination immediately after being subjected to blunt impact. Twelve additional intact eyes were examined as controls. All pathological sections were scored to indicate whether retinal detachment had occurred. RESULTS: A dynamic variation in intraocular pressure was detected following impact and exhibited an approximate sinusoidal oscillation-attenuation profile. The peaks of impact force were 12.9 ± 1.9 N at low-energy level and 34.8 ± 9.8 N at high-energy level, showing a significant difference (p < 0.001). The positive and negative peaks of intraocular pressure were 149.4 ± 18.9 kPa and -10.9 ± 7.2 kPa at low-energy level, and 274.5 ± 55.2 kPa and -35.7 ± 23.7 kPa at high-energy level, showing significant differences (p < 0.001 for both levels). Retinal detachments were observed in damaged eyes while few detachments were found in control eyes. The occurrence rate of retinal detachment differed significantly (p < 0.05) between the high- and low-energy impact groups. CONCLUSIONS: This study provided experimental evidence that shockwaves produced by blunt trauma break the force equilibrium and lead to the oscillation and negative pressure, which mainly contribute to traumatic retinal detachment.


Subject(s)
Eye Injuries , Retinal Detachment , Animals , Swine , Retinal Detachment/etiology , Eye Injuries/complications , Wounds, Nonpenetrating , Eye/pathology , Retrospective Studies
18.
Micromachines (Basel) ; 14(5)2023 Apr 27.
Article in English | MEDLINE | ID: mdl-37241581

ABSTRACT

Direct ethanol fuel cells (DEFCs) need newly designed novel affordable catalysts for commercialization. Additionally, unlike bimetallic systems, trimetallic catalytic systems are not extensively investigated in terms of their catalytic potential toward redox reactions in fuel cells. Furthermore, the Rh potential to break the ethanol rigid C-C bond at low applied potentials, and therefore enhance the DEFC efficiency and CO2 yield, is controversial amongst researchers. In this work, two PdRhNi/C, Pd/C, Rh/C and Ni/C electrocatalysts are synthesized via a one-step impregnation process at ambient pressure and temperature. The catalysts are then applied for ethanol electrooxidation reaction (EOR). Electrochemical evaluation is performed using cyclic voltammetry (CV) and chronoamperometry (CA). Physiochemical characterization is pursued using X-ray diffraction (XRD), transmission electron microscope (TEM), energy-dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS). Unlike Pd/C, the prepared Rh/C and Ni/C do not show any activity for (EOR). The followed protocol produces alloyed dispersed PdRhNi nanoparticles of 3 nm in size. However, the PdRhNi/C samples underperform the monometallic Pd/C, even though the Ni or Rh individual addition to it enhances its activity, as reported in the literature herein. The exact reasons for the low PdRhNi performance are not fully understood. However, a reasonable reference can be given about the lower Pd surface coverage on both PdRhNi samples according to the XPS and EDX results. Furthermore, adding both Rh and Ni to Pd exercises compressive strain on the Pd lattice, noted by the PdRhNi XRD peak shift to higher angles.

SELECTION OF CITATIONS
SEARCH DETAIL
...