Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Crit Care ; 23(1): 278, 2019 08 09.
Article in English | MEDLINE | ID: mdl-31399052

ABSTRACT

BACKGROUND: As many as 90% of patients develop anemia by their third day in an intensive care unit (ICU). We evaluated the efficacy of interventions to reduce phlebotomy-related blood loss on the volume of blood lost, hemoglobin levels, transfusions, and incidence of anemia. METHODS: We conducted a systematic review and meta-analysis using the Laboratory Medicine Best Practices (LMBP) systematic review methods for rating study quality and assessing the body of evidence. Searches of PubMed, Embase, Cochrane, Web of Science, PsychINFO, and CINAHL identified 2564 published references. We included studies of the impact of interventions to reduce phlebotomy-related blood loss on blood loss, hemoglobin levels, transfusions, or anemia among hospital inpatients. We excluded studies not published in English and studies that did not have a comparison group, did not report an outcome of interest, or were rated as poor quality. Twenty-one studies met these criteria. We conducted a meta-analysis if > 2 homogenous studies reported sufficient information for analysis. RESULTS: We found moderate, consistent evidence that devices that return blood from flushing venous or arterial lines to the patient reduced blood loss by approximately 25% in both neonatal ICU (NICU) and adult ICU patients [pooled estimate in adults, 24.7 (95% CI = 12.1-37.3)]. Bundled interventions that included blood conservation devices appeared to reduce blood loss by at least 25% (suggestive evidence). The evidence was insufficient to determine if these devices reduced hemoglobin decline or risk of anemia. The evidence suggested that small volume tubes reduced the risk of anemia, but was insufficient to determine if they affected the volume of blood loss or the rate of hemoglobin decline. CONCLUSIONS: Moderate, consistent evidence indicated that devices that return blood from testing or flushing lines to the patient reduce the volume of blood loss by approximately 25% among ICU patients. The results of this systematic review support the use of blood conservation systems with arterial or venous catheters to eliminate blood waste when drawing blood for testing. The evidence was insufficient to conclude the devices impacted hemoglobin levels or transfusion rates. The use of small volume tubes may reduce the risk of anemia.


Subject(s)
Anemia/prevention & control , Phlebotomy/methods , Anemia/epidemiology , Humans , Iatrogenic Disease/epidemiology , Iatrogenic Disease/prevention & control , Intensive Care Units/organization & administration , Intensive Care Units/statistics & numerical data , Phlebotomy/standards , Phlebotomy/trends , Practice Guidelines as Topic
2.
J Appl Lab Med ; 2(2): 244-258, 2017 Sep.
Article in English | MEDLINE | ID: mdl-29181454

ABSTRACT

BACKGROUND: Specimen labeling errors have long plagued the laboratory industry putting patients at risk of transfusion-related death, medication errors, misdiagnosis, and patient mismanagement. Many interventions have been implemented and deemed to be effective in reducing sample error rates. The objective of this review was to identify and evaluate the effectiveness of laboratory practices/ interventions to develop evidence based recommendations for the best laboratory practices to reduce labeling errors. CONTENT: The standardized LMBP™ A-6 methods were used to conduct this systematic review. Total evidence included 12 studies published during the time periods of 1980 to September 2015. Combined data from seven studies found that the interventions developed as a result of improved communication and collaboration between the laboratory and clinical staff resulted in substantial decrease in specimen labeling errors (Median relative percent change in labeling errors: -75.86; IQI: -84.77, -58.00). Further data from subset of four studies showed a significant decrease in specimen labeling errors after the institution of the standardized specimen labeling protocols (Median relative percent decrease in specimen labeling errors: -72.45; IQI: -83.25, -46.50). SUMMARY: Based on the evidence included in this review, the interventions that enhance the communication and collaboration between laboratory and healthcare professionals can decrease the specimen identification errors in healthcare settings. However, more research is needed to make the conclusion on the effectiveness of other evaluated practices in this review including training and education of the specimen collection staff, audit and feedback of labeling errors, and implementation of new technology (other than barcoding).

8.
MLO Med Lab Obs ; 41(4): 18, 20-1, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19456062
10.
SELECTION OF CITATIONS
SEARCH DETAIL
...