Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Bone Joint J ; 100-B(10): 1330-1335, 2018 10.
Article in English | MEDLINE | ID: mdl-30295528

ABSTRACT

AIMS: The aim of this study was to evaluate the surface damage, the density of crosslinking, and oxidation in retrieved antioxidant-stabilized highly crosslinked polyethylene (A-XLPE) tibial inserts from total knee arthroplasty (TKA), and to compare the results with a matched cohort of standard remelted highly crosslinked polyethylene (XLPE) inserts. MATERIALS AND METHODS: A total of 19 A-XLPE tibial inserts were retrieved during revision TKA and matched to 18 retrieved XLPE inserts according to the demographics of the patients, with a mean length of implantation of 15 months (1 to 42). The percentage areas of PE damage on the articular surfaces and the modes of damage were measured. The density of crosslinking of the PE and oxidation were measured at loaded and unloaded regions on these surfaces. RESULTS: A-XLPE inserts had higher rates of burnishing and lower rates of pitting and scratching compared with XLPE. There were no differences in the density of crosslinking at loaded and unloaded regions. A-XLPE showed higher oxidation indices in the unloaded surface region compared with XLPE. There were no differences in the levels of oxidation in the loaded regions. CONCLUSION: Retrieval analysis of A-XLPE did not reflect a clinically relevant difference in surface damage, density of crosslinking, or oxidation compared with XLPE tibial inserts at short-term evaluation. Cite this article: Bone Joint J 2018;100-B:1330-5.


Subject(s)
Antioxidants , Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis , Polyethylene , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Device Removal , Female , Follow-Up Studies , Humans , Male , Middle Aged , Oxidation-Reduction , Prosthesis Design , Reoperation , Retrospective Studies
2.
Bone Joint J ; 100-B(10): 1275-1279, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30295531

ABSTRACT

AIMS: The purpose of this study was to evaluate spinopelvic mechanics from standing and sitting positions in subjects with and without femoroacetabular impingement (FAI). We hypothesize that FAI patients will experience less flexion at the lumbar spine and more flexion at the hip whilst changing from standing to sitting positions than subjects without FAI. This increase in hip flexion may contribute to symptomatology in FAI. PATIENTS AND METHODS: Male subjects were prospectively enrolled to the study (n = 20). Mean age was 31 years old (22 to 41). All underwent clinical examination, plain radiographs, and dynamic imaging using EOS. Subjects were categorized into three groups: non-FAI (no radiographic or clinical FAI or pain), asymptomatic FAI (radiographic and clinical FAI but no pain), and symptomatic FAI (patients with both pain and radiographic FAI). FAI was defined as internal rotation less than 15° and alpha angle greater than 60°. Subjects underwent standing and sitting radiographs in order to measure spine and femoroacetabular flexion. RESULTS: Compared with non-FAI controls, symptomatic patients with FAI had less flexion at the spine (mean 22°, sd 12°, vs mean 35°, sd 8°; p = 0.04) and more at the hip (mean 72°, sd 6°, vs mean 62°, sd 8°; p = 0.047). Subjects with asymptomatic FAI had more spine flexion and similar hip flexion when compared to symptomatic FAI patients. Both FAI groups also sat with more anterior pelvic tilt than control patients. There were no differences in standing alignment among groups. CONCLUSION: Symptomatic patients with FAI require more flexion at the hip to achieve sitting position due to their inability to compensate through the lumbar spine. With limited spine flexion, FAI patients sit with more anterior pelvic tilt, which may lead to impingement between the acetabulum and proximal femur. Differences in spinopelvic mechanics between FAI and non-FAI patients may contribute to the progression of FAI symptoms. Cite this article: Bone Joint J 2018;100-B:1275-9.


Subject(s)
Femoracetabular Impingement/etiology , Lordosis/physiopathology , Lumbar Vertebrae/physiopathology , Pelvic Bones/physiopathology , Adolescent , Adult , Biomechanical Phenomena , Case-Control Studies , Femoracetabular Impingement/physiopathology , Humans , Lordosis/diagnostic imaging , Lumbar Vertebrae/diagnostic imaging , Male , Pelvic Bones/diagnostic imaging , Posture , Prospective Studies , Radiography , Range of Motion, Articular , Young Adult
3.
Bone Joint J ; 100-B(10): 1289-1296, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30295534

ABSTRACT

AIMS: The aims of this study were to measure sagittal standing and sitting lumbar-pelvic-femoral alignment in patients before and following total hip arthroplasty (THA), and to consider what preoperative factors may influence a change in postoperative pelvic position. PATIENTS AND METHODS: A total of 161 patients were considered for inclusion. Patients had a mean age of the remaining 61 years (sd 11) with a mean body mass index (BMI) of 28 kg/m2 (sd 6). Of the 161 patients, 82 were male (51%). We excluded 17 patients (11%) with spinal conditions known to affect lumbar mobility as well as the rotational axis of the spine. Standing and sitting spine-to-lower-limb radiographs were taken of the remaining 144 patients before and one year following THA. Spinopelvic alignment measurements, including sacral slope, lumbar lordosis, and pelvic incidence, were measured. These angles were used to calculate lumbar spine flexion and femoroacetabular hip flexion from a standing to sitting position. A radiographic scoring system was used to identify those patients in the series who had lumbar degenerative disc disease (DDD) and compare spinopelvic parameters between those patients with DDD (n = 38) and those who did not (n = 106). RESULTS: Following THA, patients sat with more anterior pelvic tilt (mean increased sacral slope 18° preoperatively versus 23° postoperatively; p = 0.001) and more lumbar lordosis (mean 28° preoperatively versus 35° postoperatively; p = 0.001). Preoperative change in sacral slope from standing to sitting (p = 0.03) and the absence of DDD (p = 0.001) correlated to an increased change in postoperative sitting pelvic alignment. CONCLUSION: Sitting lumbar-pelvic-femoral alignment following THA may be driven by hip arthritis and/or spinal deformity. Patients with DDD and fixed spinopelvic alignment have a predictable pelvic position one year following THA. Patients with normal spines have less predictable postoperative pelvic position, which is likely to be driven by hip stiffness. Cite this article: Bone Joint J 2018;100-B:1289-96.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Malalignment/etiology , Femur , Lumbar Vertebrae , Pelvic Bones , Postoperative Complications/etiology , Posture , Adult , Aged , Bone Malalignment/diagnostic imaging , Bone Malalignment/physiopathology , Cross-Sectional Studies , Female , Femur/diagnostic imaging , Femur/physiopathology , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/physiopathology , Male , Middle Aged , Pelvic Bones/diagnostic imaging , Pelvic Bones/physiopathology , Postoperative Complications/diagnostic imaging , Postoperative Complications/physiopathology , Preoperative Period , Range of Motion, Articular , Risk Factors
4.
J Bone Joint Surg Br ; 94(7): 901-7, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22733943

ABSTRACT

We analysed 54 alumina ceramic-on-ceramic bearings from total hip replacements retrieved at one centre after a mean duration of 3.5 years (0.2 to 10.6) in situ. These implants were obtained from 54 patients (16 men and 38 women) with a mean age of 67 years (33 to 88) who underwent revision for a variety of reasons. Posterior edge loading was found in the majority of these retrievals (32 out of 54). Anterosuperior edge loading occurred less often but produced a higher rate of wear. Stripe wear on the femoral heads had a median volumetric wear rate of 0.2 mm(3)/year (0 to 7.2). The wear volume on the femoral heads corresponded to the width of edge wear on the matching liner. Anteversion of the acetabular component was found to be a more important determinant than inclination for wear in ceramic bearings. Posterior edge loading may be considered to be a normal occurrence in ceramic-on-ceramic bearings, with minimal clinical consequences. Edge loading should be defined as either anterosuperior or posterior, as each edge loading mechanism may result in different clinical implications.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Adult , Aged , Aged, 80 and over , Aluminum Oxide , Arthroplasty, Replacement, Hip/methods , Ceramics , Equipment Failure Analysis/methods , Female , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Reoperation , Weight-Bearing
SELECTION OF CITATIONS
SEARCH DETAIL