Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Anal Sci ; 40(3): 489-499, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38165524

ABSTRACT

In our study, we present an innovative method for the analysis and real-time monitoring of peracetic acid (PAA) formation within the near-UV/Vis (visible) wavelength region. PAA's absorption spectrum, influenced by its presence in a complex quaternary equilibrium mixture with hydrogen peroxide (H2O2), acetic acid, and water, lacks discernible peaks. This inherent complexity challenges conventional analytical techniques like Beer's law, which rely on absorption intensity as a foundation. To address this challenge, we introduce a novel approach that centers on the analysis of blue shifts in absorption wavelengths, particularly at an absorbance of 0.8 a.u. This method significantly enhances the precision of calibration curves for both diluted PAA and H2O2, unveiling an exponential correlation between wavelength and the logarithm of concentration for both components. Significantly, our approach allows for real-time and accurate measurements, especially during the dynamic PAA formation reaction. Our results exhibit excellent agreement with data obtained from Fourier-transform infrared (FT-IR) spectroscopy, validating the reliability of our method. It's noteworthy that under stable PAA concentration conditions (after 12 h of solution interaction), both traditional absorption method and our approach closely align with the FT-IR method. However, in dynamic scenarios (0-12 h), the absorption method exhibits higher error rates compared to our approach. Additionally, the increased concentration of a catalyst, sulfuric acid (H2SO4), significantly reduces the errors in both methods, a finding that warrants further exploration. In summary, our study not only advances our understanding of PAA and its spectral behavior but also introduces innovative and precise methods for determining PAA concentration in complex solutions. These advancements hold the potential to revolutionize the field of chemical analysis and spectroscopy.

2.
Micromachines (Basel) ; 14(7)2023 Jul 11.
Article in English | MEDLINE | ID: mdl-37512715

ABSTRACT

Single-cell analysis has become increasingly important in uncovering cell heterogeneity, which has great implications in medicine and biology for a deep understanding of cell characteristics. Owing to its significance, it is vital to create novel devices that can reveal special or unique cells. In this work, we developed a single-cell secretion detection chip consisting of microwells that can trap single cells. Each well is surrounded by Au nanopillars capable of localized surface plasmon resonance (LSPR) measurement. Using microfabrication and nanofabrication techniques, Au nanopillar and microwell structures were fabricated on a COP film. The Au nanopillar was modified with IL-6 antibodies for the direct detection of single-cell secreted IL-6 via LSPR absorbance peak shift. Specific IL-6 detection was successfully demonstrated using a null and IL-6 oversecreting Jurkat cell. A high single-cell trapping efficiency of over 80% was also achieved. Overall, the development of this single-cell secretion detection chip with a simple LSPR measurement setup represents a significant development in the field of cell biology and immunology, providing researchers with a powerful tool for studying individual cells and their secreted cytokines, and is useful for point-of-care testing (POCT) diagnostics.

3.
Methods Mol Biol ; 2689: 119-142, 2023.
Article in English | MEDLINE | ID: mdl-37430051

ABSTRACT

The use of microfluidic technology in single-cell assay has shown potential in biomedical applications like protein quantification, immune response monitoring, and drug discovery. Because of the details of information that can be obtained at single-cell resolution, the single-cell assay has been applied to tackle challenging issues such as cancer treatment. Information like the levels of protein expression, cellular heterogeneity, and unique behaviors within subsets are very important in the biomedical field. For a single-cell assay system, a high-throughput platform that can do on-demand media exchange and real-time monitoring is advantageous in single-cell screening and profiling. In this work, a high-throughput valve-based device is presented, its use in single-cell assay, particularly in protein quantification and surface-marker analysis, and its potential application to immune response monitoring and drug discovery are laid down in detail.


Subject(s)
Drug Discovery , Microfluidics , High-Throughput Screening Assays , Catheters , Biological Assay
4.
Biochem Biophys Res Commun ; 657: 8-15, 2023 05 21.
Article in English | MEDLINE | ID: mdl-36963175

ABSTRACT

A new non-invasive screening profile has been realized that can aid in determining T-cell activation state at single-cell level. Production of activated T-cells with good specificity and stable proliferation is greatly beneficial for advancing adoptive immunotherapy as innate immunological cells are not effective in recognizing and eliminating cancer as expected. The screening method is realized by relating intracellular Ca2+ intensity and motility of T-cells interacting with APC (Antigen Presenting Cells) in a microfluidic chip. The system is tested using APC pulsed with OVA257-264 peptide and its modified affinities (N4, Q4, T4 and V4), and the T-cells from OT-1 mice. In addition, single cell RNA sequencing reveals the activation states of the cells and the clusters from the derived profiles can be indicative of the T-cell activation state. The presented system here can be versatile for a comprehensive application to proceed with T-cell-based immunotherapy and screen the antigen-specific T-cells with excellent efficiency and high proliferation.


Subject(s)
Microfluidics , T-Lymphocytes , Mice , Animals , Antigens , Antigen-Presenting Cells , Lymphocyte Activation
5.
Sci Rep ; 11(1): 12995, 2021 06 21.
Article in English | MEDLINE | ID: mdl-34155296

ABSTRACT

The need for high throughput single cell screening platforms has been increasing with advancements in genomics and proteomics to identify heterogeneity, unique cell subsets or super mutants from thousands of cells within a population. For real-time monitoring of enzyme kinetics and protein expression profiling, valve-based microfluidics or pneumatic valving that can compartmentalize single cells is advantageous by providing on-demand fluid exchange capability for several steps in assay protocol and on-chip culturing. However, this technique is throughput limited by the number of compartments in the array. Thus, one big challenge lies in increasing the number of microvalves to several thousand that can be actuated in the microfluidic device to confine enzymes and substrates in picoliter volumes. This work explores the design and optimizations done on a microfluidic platform to achieve high-throughput single cell compartmentalization as applied to single-cell enzymatic assay for protein expression quantification. Design modeling through COMSOL Multiphysics was utilized to determine the circular microvalve's optimized parameters, which can close thousands of microchambers in an array at lower sealing pressure. Multiphysical modeling results demonstrated the relationships of geometry, valve dimensions, and sealing pressure, which were applied in the fabrication of a microfluidic device comprising of up to 5000 hydrodynamic traps and corresponding microvalves. Comparing the effects of geometry, actuation media and fabrication technique, a sealing pressure as low as 0.04 MPa was achieved. Applying to single cell enzymatic assay, variations in granzyme B activity in Jurkat and human PBMC cells were observed. Improvement in the microfluidic chip's throughput is significant in single cell analysis applications, especially in drug discovery and treatment personalization.


Subject(s)
Microfluidics/methods , Single-Cell Analysis/methods , Algorithms , Biological Assay , Equipment Design , High-Throughput Screening Assays , Hydrodynamics , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Microfluidics/instrumentation , Models, Theoretical , Single-Cell Analysis/instrumentation
6.
Sensors (Basel) ; 21(4)2021 Feb 09.
Article in English | MEDLINE | ID: mdl-33572363

ABSTRACT

Here we report the improved Cyclo olefin polymer (COP) microfluidic chip and polymerase chain reaction (PCR) amplification system for point-of-care testing (POCT) in rapid detection of Carbapenem-resistant Enterobacteriaceae (CRE). The PCR solution and thermal cycling is controlled by the relative gravitational acceleration (7G) only and is expected to pose minimal problem in operation by non-expert users. Detection is based on identifying the presence of carbapenemase encoding gene through the corresponding fluorescence signal after amplification. For preliminary tests, the device has been demonstrated to detect blaIMP-6 from patients stool samples. From the prepared samples, 96.4 fg/µL was detected with good certainty within 15 min (~106 thermocycles,) which is significantly faster than the conventional culture plate method. Moreover, the device is expected to detect other target genes in parallel as determination of the presence of blaNDM-1 and blaOXA-23 from control samples has also been demonstrated. With the rising threat of drug-resistant bacteria in global healthcare, this technology can greatly aid the health sector by enabling the appropriate use of antibiotics, accelerating the treatment of carriers, and suppressing the spread.


Subject(s)
Convection , Pharmaceutical Preparations , Polymerase Chain Reaction , Acceleration , Anti-Bacterial Agents/therapeutic use , Bacterial Proteins , Humans , Microbial Sensitivity Tests
7.
ACS Appl Bio Mater ; 4(11): 7913-7920, 2021 11 15.
Article in English | MEDLINE | ID: mdl-35006772

ABSTRACT

A Au-capped nanopillar chip was prepared using nanoimprint lithography (NIL) and Au sputtering onto a cyclo-olefin polymer film. The Au surface of the chip exerting localized surface plasmon resonance (LSPR) phenomena was immobilized with a glycopolymer for the detection of cytokines. The glycopolymers were synthesized by reversible addition-fragmentation chain transfer (RAFT) polymerization for controlled polymer chain length, and thiol-terminated glycopolymers with chain lengths of 20-, 100-, and 200-mers were designed. The thickness of the biomolecular layer on the Au surface was controlled by changing the polymer chain length of the immobilized glycopolymer, and the absorption of proteins onto the Au surface was detected by the shift of absorbance peak wavelength. The value of absorbance peak wavelength shift by protein adsorption increased as the glycopolymer layer thickness became thinner. This difference in LSPR signal response was remarkable for cytokine recognition compared to larger proteins. It was shown that controlling the biomolecular layer thickness was effective for the detection of small proteins, and our research suggested the usefulness of the controlled glycopolymer surface as a molecular recognition material for cytokine detection.


Subject(s)
Polymers , Surface Plasmon Resonance , Adsorption , Cytokines , Polymerization , Polymers/metabolism
8.
Cancer Gene Ther ; 28(9): 895-910, 2021 09.
Article in English | MEDLINE | ID: mdl-33110208

ABSTRACT

Recent advances in microfluidic techniques have enabled researchers to study sensitivities to immune checkpoint therapy, to determine patients' response to particular antibody treatment. Utilization of this technology is helpful in antibody discovery and in the design of personalized medicine. A variety of microfluidic approaches can provide several functions in processes such as immunologic, genomic, and/or transcriptomic analysis with the aim of improving the efficacy and coverage of immunotherapy, particularly immune checkpoint blockade (ICB). To achieve this requires researchers to overcome the challenges in the current state of the technology. This review looks into the advancements in microfluidic technologies applied to researches on immune checkpoint blockade treatment and its potential shift from proof-of-principle stage to clinical application.


Subject(s)
Immune Checkpoint Inhibitors/therapeutic use , Immunotherapy/methods , Microfluidics/methods , Humans , Immune Checkpoint Inhibitors/pharmacology
9.
Biomed Opt Express ; 11(10): 6027-6037, 2020 Oct 01.
Article in English | MEDLINE | ID: mdl-33150003

ABSTRACT

We studied the elastic profile of monocytic THP-1 leukemia cells using a microfluidic-assisted optical trap. A 2-µm fused silica bead was optically trapped to mechanically dent an immobilized single THP-1 monocyte sieved on a 15-µm microfluidic capture chamber. Cells treated with Zeocin and untreated cells underwent RT-qPCR analysis to determine cell apoptosis through gene expression in relation to each cell's deformation profile. Results showed that untreated cells with 43.05 ± 6.68 Pa are more elastic compared to the treated cells with 15.81 ± 2.94 Pa. THP-1 monocyte's elastic modulus is indicative of cell apoptosis shown by upregulated genes after Zeocin treatment. This study clearly showed that the developed technique can be used to distinguish between cells undergoing apoptosis and cells not undergoing apoptosis and which may apply to the study of other cells and other cell states as well.

10.
Micromachines (Basel) ; 11(1)2020 Jan 19.
Article in English | MEDLINE | ID: mdl-31963848

ABSTRACT

Cytokine secretion researches have been a main focus of studies among the scientists in the recent decades for its outstanding contribution to clinical diagnostics. Localized surface plasmon resonance (LSPR) technology is one of the conventional methods utilized to analyze these issues, as it could provide fast, label-free and real-time monitoring of biomolecule binding events. However, numerous LSPR-based biosensors in the past are usually utilized to monitor the average performance of cell groups rather than single cells. Meanwhile, the complicated sensor structures will lead to the fabrication and economic budget problems. Thus, in this paper, we report a simple synergistic integration of the cell trapping of microwell chip and gold-capped nanopillar-structured cyclo-olefin-polymer (COP) film for single cell level Interleukin 6 (IL-6) detection. Here, in-situ cytokine secreted from the trapped cell can be directly observed and analyzed through the peak red-shift in the transmittance spectrum. The fabricated device also shows the potential to conduct the real-time monitoring which would greatly help us identify the viability and biological variation of the tested single cell.

11.
Theranostics ; 10(1): 123-132, 2020.
Article in English | MEDLINE | ID: mdl-31903110

ABSTRACT

Granzyme B (GrB) is an essential cytotoxic effector in cancer immunotherapy as it can be a potential biomarker to predict the efficacy of immunotherapies including checkpoint inhibitors. Monitoring the Granzyme B activity in cells would help determine a patient's clinical response to treatment and lead to better treatment strategies by preventing administration of ineffective therapies and avoid adverse events resulting in a delay in subsequent treatment. Methods: A microfluidic device with hydrodynamic traps and pneumatic valving system was fabricated using photo and soft lithography. Single cell Granzyme B (GrB) activity was detected and measured fluorometrically using a commercial assay kit with a peptide substrate containing GrB recognition sequence (Ac-IEPD-AFC) and AFC (7-Amino-4-trifluoromethylcoumarin) label. Fluorescence was observed and measured using a confocal microscope with CSU-W1 scanner unit and CCD camera as well as an inverted microscope with photodetector. Model cells (NK-92, GrB-transduced Jurkat, and THP1 cells) and human PBMCs from healthy donor and lung cancer patients including an anti-PD-1 antibody treated patient were profiled of its GrB activity as proof of concept. Results: GrB expression from the model cells was found to be markedly different. NK-92 cells were found to have higher GrB activity than the GrB-transduced Jurkat cells. THP-1 was found to have relatively no significant activity. A marked increase in GrB expression was also observed in anti-PD-1 treated lung cancer patient sample in comparison to PBMC from a healthy donor. TCR+ Ig-G4+ PBMC cells were found to have high activity which signifies a clear response to PD-1 blockade. Conclusion: As proof of concept, we have shown the capability of a microfluidic platform to measure GrB production through a single cell enzymatic activity assay. Our platform might be a promising tool for evaluating the sensitivity of immunotherapies and identifying specific T cell subset responsible for the anti-tumor response.


Subject(s)
Granzymes/metabolism , Microfluidics , Single-Cell Analysis , Biomarkers/metabolism , Humans , Jurkat Cells , Leukocytes, Mononuclear/enzymology , Lung Neoplasms/drug therapy , Microfluidics/instrumentation , Microfluidics/methods , Single-Cell Analysis/instrumentation , Single-Cell Analysis/methods , THP-1 Cells
12.
Sci Rep ; 9(1): 20150, 2019 12 27.
Article in English | MEDLINE | ID: mdl-31882905

ABSTRACT

Miniaturizing the enzyme-linked immunosorbent assay (ELISA) protocols in microfluidics is sought after by researchers for a rapid, high throughput screening, on-site diagnosis, and ease in operation for detection and quantification of biomarkers. Herein, we report the use of the centrifugation-controlled convective (C3) flow as an alternative method in fluid flow control in a ring-structured channel for enhanced on-chip ELISA. A system that consists of a rotating heater stage and a microfluidic disk chip has been developed and demonstrated to detect IgA. The ring-structured channel was partially filled with microbeads (250 µm in diameter) carrying the capture antibodies and the analyte solution was driven by thermal convection flow (50 µL/min) to promote the reaction. The remaining part of the circular channel without microbeads served as the observation area to measure the absorbance value of the labeled protein. Currently, the system is capable of conducting four reactions in parallel and can be performed within 30 min at 300 G. A detection limit of 6.16 ng/mL using 24 µL of target sample (IgA) was observed. By simply changing the capture antibodies, the system is expected to be versatile for other immunoassays.


Subject(s)
Centrifugation , Enzyme-Linked Immunosorbent Assay/instrumentation , Enzyme-Linked Immunosorbent Assay/methods , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques , Equipment Design , Humans
13.
Micromachines (Basel) ; 11(1)2019 Dec 31.
Article in English | MEDLINE | ID: mdl-31906070

ABSTRACT

A simple microengraving cell monitoring method for neutrophil extracellular traps (NETs) released from single neutrophils has been realized using a polydimethylsiloxane (PDMS) microwell array (MWA) sheet on a plasmon chip platform. An imbalance between NETs formation and the succeeding degradation (NETosis) are considered associated with autoimmune disease and its pathogenesis. Thus, an alternative platform that can conduct monitoring of this activity on single cell level at minimum cost but with great sensitivity is greatly desired. The developed MWA plasmon chips allow single cell isolation of neutrophils from 150 µL suspension (6.0 × 105 cells/mL) with an efficiency of 36.3%; 105 microwells with single cell condition. To demonstrate the utility of the chip, trapped cells were incubated between 2 to 4 h after introducing with 100 nM phorbol 12-myristate 13-acetate (PMA) before measurement. Under observation using a hyperspectral imaging system that allows high-throughput screening, the neutrophils stimulated by PMA solution show a significant release of fibrils and NETs after 4 h, with observed maximum areas between 314-758 µm2. An average absorption peak wavelength shows a redshift of Δλ = 1.5 nm as neutrophils release NETs.

14.
Anal Chem ; 89(23): 12797-12804, 2017 Dec 05.
Article in English | MEDLINE | ID: mdl-29111686

ABSTRACT

Here, we report the developed cyclo olefin polymer (COP) microfluidic chip on a fabricated rotating heater stage that utilizes centrifugation-assisted thermal cycle in a ring-structured microchannel for polymerase chain reaction (PCR). The PCR solution could be driven by thermal convection and continuously exchanged high/low temperatures in a ring structured microchannel without the use of typical syringe pump. More importantly, the flow rate was controlled by the relative gravitational acceleration only. The platform enables amplification within 10 min at 5G and has a detection limit of 70.5 pg/channel DNA concentration (ß-actin, 295 bp). The current rotating system is capable of testing four different samples in parallel. The microfluidic chip can be preloaded with the PCR premix solution for on-site utility, and, with all of the features integrated to the system, the test can be conducted without the need for specialized laboratory and trained laboratory staff. In addition, this innovative chemical reaction technique has the potential to be utilized in other micromixing applications.

15.
Analyst ; 140(19): 6500-7, 2015 Oct 07.
Article in English | MEDLINE | ID: mdl-26309911

ABSTRACT

Quantitative diagnosis of pharmacological chronotropic reactions on mouse embryonic stem cell-derived cardiomyocytes (mESC-CMs) was successfully performed by utilizing derivative imaging analysis of videos recorded with a microscope camera at 30 Hz frame rate and 680 × 510 pixel resolution. The imaging analysis algorithm, developed in our lab, generated the contractile profile of the cells which was exploited for drug effect profiling. Six drugs such as isoproterenol (0.01-1 µM), quinidine (2-200 µM), propranolol (0.03-30 µM), verapamil (0.01-1 µM), sotalol (1-100 µM), and acetylsalicylic acid (0.1-10 µM) were administered and the quantitative medication effect was determined. Among the negative chronotropic agents administered, verapamil was found to be the most potent while sotalol was found to be the least potent at the micromolar level. Simultaneous measurement of the field potential and contractile motion in the verapamil effect test showed a coherent result. Moreover, this approach can provide insights into the contraction-relaxation conditions which are not available in the common electrophysiological approach. With these findings, it is expected that this study can aid in providing a simple and reliable in vitro mESC-CM-based screening platform for cardiovascular effect profiling of candidate drugs.


Subject(s)
Microscopy , Mouse Embryonic Stem Cells/cytology , Myocytes, Cardiac/cytology , Myocytes, Cardiac/drug effects , Animals , Cell Movement/drug effects , Drug Discovery , Heart Rate/drug effects , Mice , Myocardial Contraction/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL
...