Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Anal Chem ; 79(12): 4724-8, 2007 Jun 15.
Article in English | MEDLINE | ID: mdl-17508719

ABSTRACT

We present a new type of DNA switch, based on the Holliday junction, that uses a combination of binding and conformational switching to enable specific label-free detection of DNA and RNA. We show that a single RNA oligonucleotide species can be detected in a complex mixture of extracted cellular RNA and demonstrate that by exploiting different aspects of the switch characteristics we can achieve 30-fold discrimination between single-nucleotide mismatches in a DNA oligonucleotide.


Subject(s)
Biosensing Techniques/methods , DNA/analysis , RNA/analysis , Biosensing Techniques/instrumentation , Nucleic Acid Conformation , Nucleic Acid Hybridization , Oligonucleotide Probes/analysis , Oligonucleotides/analysis , Sensitivity and Specificity
2.
Langmuir ; 22(26): 11400-4, 2006 Dec 19.
Article in English | MEDLINE | ID: mdl-17154632

ABSTRACT

This work reports how the use of a standard integrated circuit (IC) fabrication process can improve the potential of silicon nitride layers as substrates for microarray technology. It has been shown that chemical mechanical polishing (CMP) substantially improves the fluorescent intensity of positive control gene and test gene microarray spots on both low-pressure chemical vapor deposition (LPCVD) and plasma-enhanced chemical vapor deposition (PECVD) silicon nitride films, while maintaining a low fluorescent background. This results in the improved discrimination of low expressing genes. The results for the PECVD silicon nitride, which has been previously reported as unsuitable for microarray spotting, are particularly significant for future devices that hope to incorporate microelectronic control and analysis circuitry, due to the film's use as a final passivating layer.


Subject(s)
Oligonucleotide Array Sequence Analysis , Silicon Compounds/chemistry , Fluorescence , Oligonucleotide Array Sequence Analysis/methods
3.
Anal Chem ; 74(6): 1322-6, 2002 Mar 15.
Article in English | MEDLINE | ID: mdl-11924592

ABSTRACT

Mesoporous (H(I)-ePt) platinum microelectrodes electrodeposited from the hexagonal (H(I)) lyotropic liquid crystalline phase are shown to be excellent amperometric sensors for the detection of hydrogen peroxide over a wide range of concentrations. Good reproducibility, high precision, and accuracy of measurements are demonstrated. Mesoporous microelectrodes retain the high rates of mass transport typical of conventional microelectrodes, and their high real surface area greatly enhances their catalytic activity. This unique combination of properties overcomes the limitations of previous amperometric hydrogen peroxide sensors and yields outstanding qualitative and quantitative results.

SELECTION OF CITATIONS
SEARCH DETAIL