1.
Gastrointest Endosc ; 99(1): 23-30.e1, 2024 01.
Article in English | MEDLINE | ID: mdl-37543062

ABSTRACT

BACKGROUND AND AIMS: Buried bumper syndrome (BBS) is a rare adverse event of PEG tubes. This study compared the newly developed Flamingo device (Fujifilm Medwork GmbH, Höchstadt, Germany) with conventional endoscopic techniques for BBS treatment. METHODS: This prospective, randomized controlled trial compared the Flamingo set (study group) with other endoscopic techniques (control group) for BBS treatment in 6 German hospitals. The primary endpoint was procedure time. Further outcome parameters were technical success, adverse event rate, and number and cost of devices used in each group. RESULTS: Thirty-six patients (18 in each group; mean age, 73 years; 12 women) were included in this study between March 2018 and December 2022. Median time since placement of the feeding tube was 30 months. The bumper was located in the gastric corpus in 27 patients, and the internal bumper was completely overgrown in 31 patients. The duration of the removal procedure was 17 minutes (range, 3-72) in the study group compared with 38 minutes (range, 12-111) in the control group (P = .046). The primary technical success rate was 77.8% in the study group and 55.6% in the control group (P = .157), whereas the overall technical success rate was 100% compared with 83.3% (P = .070). Adverse events occurred in 4 patients (11.1%). CONCLUSIONS: Endoscopic removal of the buried bumper using the Flamingo device was significantly faster than that with other endoscopic techniques and showed a higher technical success rate. This device may become the endoscopic treatment of choice for BBS. (Clinical trial registration number: NCT03186066.).


Subject(s)
Enteral Nutrition , Gastrostomy , Humans , Female , Aged , Enteral Nutrition/methods , Gastrostomy/methods , Prospective Studies , Device Removal/methods , Endoscopy , Syndrome
2.
PLoS One ; 10(1): e0117483, 2015.
Article in English | MEDLINE | ID: mdl-25629619

ABSTRACT

BACKGROUND: Intestinal perforation or leakage increases morbidity and mortality of surgical and endoscopic interventions. We identified criteria for use of full-covered, extractable self-expanding metal stents (cSEMS) vs. 'Over the scope'-clips (OTSC) for leak closure. METHODS: Patients who underwent endoscopic treatment for postoperative leakage, endoscopic perforation, or spontaneous rupture of the upper gastrointestinal tract between 2006 and 2013 were identified at four tertiary endoscopic centers. Technical success, outcome (e.g. duration of hospitalization, in-hospital mortality), and complications were assessed and analyzed with respect to etiology, size and location of leakage. RESULTS: Of 106 patients (male: 75 (71%), female: 31 (29%); age (mean ± SD): 62.5 ± 1.3 years, 72 (69%) were treated by cSEMS and 34 (31%) by OTSC. For cSEMS vs. OTSC, mean treatment duration was 41.1 vs. 25 days, p<0.001, leakage size 10 (1-50) vs. 5 (1-30) mm (median (range)), and complications were observed in 68% vs. 8.8%, p<0.001, respectively. Clinical success for primary interventional treatment was observed in 29/72 (40%) vs. 24/34 (70%, p = 0.006), and clinical success at the end of follow-up was 46/72 (64%) vs. 29/34 (85%) for patients treated by cSEMS vs. OTSC; p = 0.04. CONCLUSION: OTSC is preferred in small-sized lesions and in perforation caused by endoscopic interventions, cSEMS in patients with concomitant local infection or abscess. cSEMS is associated with a higher frequency of complications. Therefore, OTSC might be preferred if technically feasible. Indication criteria for cSEMS vs. OTSC vary and might impede design of randomized studies.


Subject(s)
Bariatric Surgery/adverse effects , Intestinal Perforation/surgery , Stents , Endoscopy, Gastrointestinal/methods , Equipment Design , Female , Humans , Intestinal Perforation/etiology , Male , Middle Aged , Retrospective Studies , Treatment Outcome
3.
Endoscopy ; 47(1): 63-7, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25268308

ABSTRACT

BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the efficacy and safety of this stent in a large cohort. PATIENTS AND METHODS: Patients with a PFC undergoing EUS-guided drainage with this novel stent were prospectively enrolled in this multicenter cohort study. RESULTS: There were 61 patients: 46 patients (75 %) with walled-off necrosis (WON) and 15 (25 %) with a pancreatic pseudocyst. Stent placement was technically successful in 60 patients (98 %, 95 %CI 95 % - 100 %). Clinical success, defined as resolution of clinical symptoms in combination with a decrease in the PFC size to ≤ 2 cm on imaging, was achieved in 93 % of patients with a pancreatic pseudocyst (95 %CI 77 % - 100 %) and in 81 % of patients with WON (95 %CI 69 % - 94 %). Treatment failure occurred in nine patients (16 %, 95 %CI 6 % - 26 %), including four patients who required surgical intervention. Stent removal was performed in 82 % of patients after a median of 32 days (range 2 - 178) and was rated as easy in all but one patient. In 10 patients, endoscopic stent removal was not performed because of stent migration (n = 3), stent dislodgement during necrosectomy (n = 3), stent removal during surgery (n = 2), or refusal by the patient (n = 2). In total, five major complications were reported (9 %, 95 %CI 2 % - 16 %), including PFC infection (n = 4) and perforation (n = 1). CONCLUSION: EUS-guided drainage using this novel stent is feasible and the clinical results obtained are promising with a low major complication rate.


Subject(s)
Drainage/methods , Endosonography , Pancreatic Pseudocyst/therapy , Pancreatitis, Acute Necrotizing/therapy , Stents , Ultrasonography, Interventional , Adult , Aged , Drainage/instrumentation , Female , Follow-Up Studies , Humans , Logistic Models , Male , Middle Aged , Pancreatic Pseudocyst/diagnostic imaging , Pancreatitis, Acute Necrotizing/diagnostic imaging , Prospective Studies , Treatment Outcome
4.
Endoscopy ; 47(1): 76-9, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25221859

ABSTRACT

The over-the-scope clip (OTSC) system was developed for the closure of gastrointestinal defects but can also be used for endoscopic resection. This report describes the efficacy and safety of endoscopic full-thickness resection (eFTR) using the OTSC system. In this retrospective, observational, open-label case study, a total of 17 patients underwent eFTR using a dual clip and cap technique. The indications were: carcinoids, incompletely resected colon cancers involving the mucosa or submucosa, recurrent fibrosed adenoma of the colon, and submucosal lesions. The technical success was 94 % (16 /17). The complete resection (R0) rate was 100 %. There were no complications. In summary, the described minimally invasive method to perform eFTR of complex gastrointestinal lesions appears to be effective and safe.


Subject(s)
Adenoma/surgery , Carcinoid Tumor/surgery , Endoscopy, Gastrointestinal/instrumentation , Gastrointestinal Neoplasms/surgery , Adult , Aged , Aged, 80 and over , Colonic Neoplasms/surgery , Endoscopy, Gastrointestinal/methods , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome