Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 346
Filter
1.
Article in English | MEDLINE | ID: mdl-38729397
2.
Ann Intern Med ; 2024 May 21.
Article in English | MEDLINE | ID: mdl-38768453

ABSTRACT

BACKGROUND: Computer-aided diagnosis (CADx) allows prediction of polyp histology during colonoscopy, which may reduce unnecessary removal of nonneoplastic polyps. However, the potential benefits and harms of CADx are still unclear. PURPOSE: To quantify the benefit and harm of using CADx in colonoscopy for the optical diagnosis of small (≤5-mm) rectosigmoid polyps. DATA SOURCES: Medline, Embase, and Scopus were searched for articles published before 22 December 2023. STUDY SELECTION: Histologically verified diagnostic accuracy studies that evaluated the real-time performance of physicians in predicting neoplastic change of small rectosigmoid polyps without or with CADx assistance during colonoscopy. DATA EXTRACTION: The clinical benefit and harm were estimated on the basis of accuracy values of the endoscopist before and after CADx assistance. The certainty of evidence was assessed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) framework. The outcome measure for benefit was the proportion of polyps predicted to be nonneoplastic that would avoid removal with the use of CADx. The outcome measure for harm was the proportion of neoplastic polyps that would be not resected and left in situ due to an incorrect diagnosis with the use of CADx. Histology served as the reference standard for both outcomes. DATA SYNTHESIS: Ten studies, including 3620 patients with 4103 small rectosigmoid polyps, were analyzed. The studies that assessed the performance of CADx alone (9 studies; 3237 polyps) showed a sensitivity of 87.3% (95% CI, 79.2% to 92.5%) and specificity of 88.9% (CI, 81.7% to 93.5%) in predicting neoplastic change. In the studies that compared histology prediction performance before versus after CADx assistance (4 studies; 2503 polyps), there was no difference in the proportion of polyps predicted to be nonneoplastic that would avoid removal (55.4% vs. 58.4%; risk ratio [RR], 1.06 [CI, 0.96 to 1.17]; moderate-certainty evidence) or in the proportion of neoplastic polyps that would be erroneously left in situ (8.2% vs. 7.5%; RR, 0.95 [CI, 0.69 to 1.33]; moderate-certainty evidence). LIMITATION: The application of optical diagnosis was only simulated, potentially altering the decision-making process of the operator. CONCLUSION: Computer-aided diagnosis provided no incremental benefit or harm in the management of small rectosigmoid polyps during colonoscopy. PRIMARY FUNDING SOURCE: European Commission. (PROSPERO: CRD42023402197).

3.
Endosc Int Open ; 12(4): E467-E473, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38585018

ABSTRACT

Background and study aims The optimal number of needle passes during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is not yet established. We aimed to perform a per-pass analysis of the diagnostic accuracy of EUS-FNB of solid pancreatic lesions using a 22G Franseen needle. Patients and methods Consecutive patients with solid pancreatic lesions referred to 11 Italian centers were prospectively enrolled. Three needle passes were performed; specimens were collected after each pass and processed individually as standard histology following macroscopic on-site evaluation (MOSE) by the endoscopist. The primary endpoint was diagnostic accuracy of each sequential pass. Final diagnosis was established based on surgical pathology or a clinical course of at least 6 months. Secondary endpoints were specimen adequacy, MOSE reliability, factors impacting diagnostic accuracy, and procedure-related adverse events. Results A total of 504 samples from 168 patients were evaluated. Diagnostic accuracy was 90.5% (85.0%-94.1%) after one pass and 97.6% (94.1%-99.3%) after two passes ( P =0.01). Similarly, diagnostic sensitivity and sample adequacy were significantly higher adding the second needle pass (90.2%, 84.6%-94.3% vs 97.5%, 93.8%-99.3%, P =0.009 and 91.1%, 85.7%-94.9% vs 98.2%, 95.8%-99.3%, P =0.009, one pass vs two passes, respectively). Accuracy, sensitivity, and adequacy remained the same after the third pass. The concordance between MOSE and histological evaluation was 89.9%. The number of passes was the only factor associated with accuracy. One case of mild acute pancreatitis (0.6%) was managed conservatively. Conclusions At least two passes should be performed for the diagnosis of solid pancreatic lesions. MOSE is a reliable tool to predict the histological adequacy of specimens.

4.
J Clin Med ; 13(5)2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38592317

ABSTRACT

Background. The optimal management of duodenal neuroendocrine neoplasms (dNENs) sized 10-20 mm remains controversial and although endoscopic resection is increasingly performed instead of surgery, the therapeutic approach in this setting is not fully standardized. We performed a systematic review of the literature and a meta-analysis to clarify the outcomes of endoscopic resection for 10-20 mm dNENs in terms of efficacy (i.e., recurrence rate) and safety. Methods. A computerized literature search was performed using relevant keywords to identify pertinent articles published until January 2023. Results. Seven retrospective studies were included in this systematic review. The overall recurrence rate was 14.6% (95%CI 5.4-27.4) in 65 patients analyzed, without significant heterogeneity. When considering studies specifically focused on endoscopic mucosal resection, the recurrence rate was 20.5% (95%CI 10.7-32.4), without significant heterogeneity. The ability to obtain the free margin after endoscopic resection ranged between 36% and 100%. No complications were observed in the four studies reporting this information. Conclusions. Endoscopic resection could be the first treatment option in patients with dNENs sized 10-20 mm and without evidence of metastatic disease. Further studies are needed to draw more solid conclusions, particularly in terms of superiority among the available endoscopic techniques.

6.
Dig Liver Dis ; 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38458884

ABSTRACT

Colorectal cancer is a significant global health concern, necessitating effective screening strategies to reduce its incidence and mortality rates. Colonoscopy plays a crucial role in the detection and removal of colorectal neoplastic precursors. However, there are limitations and variations in the performance of endoscopists, leading to missed lesions and suboptimal outcomes. The emergence of artificial intelligence (AI) in endoscopy offers promising opportunities to improve the quality and efficacy of screening colonoscopies. In particular, AI applications, including computer-aided detection (CADe) and computer-aided characterization (CADx), have demonstrated the potential to enhance adenoma detection and optical diagnosis accuracy. Additionally, AI-assisted quality control systems aim to standardize the endoscopic examination process. This narrative review provides an overview of AI principles and discusses the current knowledge on AI-assisted endoscopy in the context of screening colonoscopies. It highlights the significant role of AI in improving lesion detection, characterization, and quality assurance during colonoscopy. However, further well-designed studies are needed to validate the clinical impact and cost-effectiveness of AI-assisted colonoscopy before its widespread implementation.

7.
Ann Gastroenterol ; 37(2): 225-234, 2024.
Article in English | MEDLINE | ID: mdl-38481781

ABSTRACT

Background: Percutaneous cholangioscopy (PerC) offers an alternative for patients with an inaccessible biliary tree. This systematic review and meta-analysis aimed to evaluate the performance of this technique. Methods: A search in Medline, Cochrane and ClinicalTrials.gov databases was performed for studies assessing PerC up to October 2022. The primary outcome was diagnostic success, defined as successful stone identification or stricture workup. Secondary outcomes included therapeutic success (stone extraction, stenting) and complication rate. A subgroup analysis compared previous-generation and modern cholangioscopes. We performed meta-analyses using a random-effects model and the results were reported as percentages with 95% confidence interval (CI). Results: Fourteen studies (682 patients) were eligible for analysis. The rate of diagnostic success was 98.7% (95%CI 97.6-99.8%; I2=31.19%) and therapeutic success was 88.6% (95%CI 82.8-94.3%; I2=74.92%). Adverse events were recorded in 17.1% (95%CI 10.7-23.5%; I2=77.56%), of which 15.9% (95%CI 9.8-21.9%; I2=75.98%) were minor and 0.6% (95%CI 0.1-1.2%; I2=0%) major. The Spyglass system showed null heterogeneity for all outcomes; compared with older-generation endoscopes it offered comparable diagnostic success, but yielded significantly superior therapeutic success (96.1%, 95%CI 90-100%; I2=0% vs. 86.4%, 95%CI 79.2-93.6%; I2=81.41%; P=0.02]. Conclusion: PerC, especially using currently available cholangioscopes, is associated with high diagnostic and therapeutic success.

8.
Endosc Int Open ; 12(3): E456-E462, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38550768

ABSTRACT

Background and study aims EUS-guided choledochoduodenostomy (EUS-CDS) is a minimally invasive procedure used to treat malignant biliary obstruction (MBO) by transduodenal placement of a lumen-apposing metal stent (LAMS) into the extrahepatic bile duct. To identify factors that contribute to safe and effective EUS-CDS using LAMS, we performed a systematic review of the literature and meta-analysis. Methods The methodology of our analysis was based on PRISMA recommendations. Electronic databases (Medline, Scopus, EMBASE) were searched up to November 2022. Full articles that included patients with distal malignant biliary obstruction who underwent EUS-CDS using LAMS after failed endoscopic retrograde cholangiopancreatography were eligible. Random-effect meta-analysis was performed reporting pooled rates of technical success, clinical success, and adverse events (AEs) by means of a random model. Multivariate meta-regression and subgroup analysis were performed to assess possible associations between the outcomes and selected variables to assess the correlation between outcomes and different variables. Results were also stratified according to stent size. Results Twelve studies with 845 patients were included in the meta-analysis. Pooled technical and clinical success rates were 96% (95% confidence interval [CI] 94%-98%; I 2 = 52.29%) and 96% (95%CI 95%-98%), respectively, with no significant association with baseline characteristics, such are sex, age, common bile duct diameter, or stent size. The pooled AE rate was 12% (95%CI: 8%-16%; I 2 = 71.62%). The AE rate was significantly lower when using an 8 × 8 mm stent as compared with a 6 × 8 mm LAMS (odds ratio 0.59, 0.35-0.99; P = 0.04), with no evidence of heterogeneity (I 2 = 0%). Conclusions EUS-CDS with LAMS is a safe and effective option for relief of MBO. Selecting an appropriate stent size is crucial for achieving optimal safety outcomes.

9.
J Clin Med ; 13(6)2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38541829

ABSTRACT

Background: The incidence of syphilis has increased in high-income countries in the past few decades, especially among men who have sex with men. In the present study, we aimed to analyze the correlations between atypical syphilis manifestations and the demographic, clinical, and laboratory features of patients and to review unusual presentations of syphilis reported in the literature. Methods: We conducted a retrospective analysis of 307 patients with syphilis diagnosed between 1 January 2013 and 31 October 2023 at the sexually transmitted infection (STI) centers of the University of Genoa and University of Foggia with both typical and atypical manifestations of disease. Results: In our series, atypical manifestations were detected in 25.8% of the patients, especially in the secondary stage of the disease. Lesions with annular morphology and lesions presenting as itchy erythematous scaly plaques with a psoriasiform appearance were the most common atypical presentations of secondary syphilis. A statistical analysis revealed that homosexual orientation, syphilis reinfection, and venereal disease research laboratory (VDRL) titers > 1:32 were correlated with atypical manifestations. Conclusions: Our study demonstrates that the spectrum of syphilis manifestations, in all the stages of the disease, is wide; atypical manifestations often pose diagnostic challenges, may delay the provision of appropriate treatment, and facilitate the spread of the infection.

13.
Cancers (Basel) ; 16(4)2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38398115

ABSTRACT

BACKGROUND: Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using lumen apposing metal stent has emerged as a minimally invasive treatment for the management of malignant gastric outlet obstruction (mGOO). We aimed to compare EUS-GE with enteral stenting (ES) for the treatment of mGOO. METHODS: Patients who underwent EUS-GE or ES for mGOO between June 2017 and June 2023 at two Italian centers were retrospectively identified. The primary outcome was stent dysfunction. Secondary outcomes included technical success, clinical failure, safety, and hospital length of stay. A propensity score-matching analysis was performed using multiple covariates. RESULTS: Overall, 198 patients were included (66 EUS-GE and 132 ES). The stent dysfunction rate was 3.1% and 16.9% following EUS-GE and ES, respectively (p = 0.004). Using propensity score-matching, 45 patients were allocated to each group. The technical success rate was 100% for both groups. Stent dysfunction was higher in the ES group compared with the EUS-GE group (20% versus 4.4%, respectively; p = 0.022) without differences in clinical efficacy (p = 0.266) and safety (p = 0.085). A significantly shorter hospital stay was associated with EUS-GE compared with ES (7.5 ± 4.9 days vs. 12.5 ± 13.0 days, respectively; p = 0.018). Kaplan-Meier analyses confirmed a higher stent dysfunction-free survival rate after EUS-GE compared with ES (log-rank test; p = 0.05). CONCLUSION: EUS-GE offers lower rates of stent dysfunction, longer stent patency, and shorter hospital stay compared with ES.

14.
J Clin Med ; 13(4)2024 Feb 09.
Article in English | MEDLINE | ID: mdl-38398321

ABSTRACT

BACKGROUND: Patients with inflammatory bowel diseases (IBD) require proactive monitoring both during the active phase to evaluate therapeutic response and during the remission phase to evaluate relapse or colorectal cancer surveillance. However, monitoring may vary between patients with ulcerative colitis (UC) and Crohn's disease (CD), with distinct tools and intervals. METHODS: This narrative review aims to focus on modern approaches to IBD monitoring, considering international guidelines and expert consensus. RESULTS: The most recent European diagnostic guidelines advocate a combination of clinical, laboratory, endoscopic, and radiological parameters to evaluate the disease course of patients with IBD. Unfortunately, the conventional symptom-based therapeutic approach does not improve long-term outcomes and there is no single ideal biomarker available. Endoscopy plays a key role in evaluating response to therapy as well as monitoring disease activity. Recently, bedside intestinal ultrasound (IUS) has gained increasing interest and diffusion as it appears to offer several advantages including the monitoring of therapeutic response. CONCLUSION: In light of growing clinical advances, we present a schematic evidence-based monitoring algorithm that can be easily applied in clinical practice which combines all major monitoring modalities, including noninvasive tools such as IUS and video-capsule endoscopy.

15.
Med Sci (Basel) ; 12(1)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38390859

ABSTRACT

Gastric outlet obstruction (GOO) poses a common and challenging clinical scenario, characterized by mechanical blockage in the pylorus, distal stomach, or duodenum, resulting in symptoms such as nausea, vomiting, abdominal pain, and early satiety. Its diverse etiology encompasses both benign and malignant disorders. The spectrum of current treatment modalities extends from conservative approaches to more invasive interventions, incorporating procedures like surgical gastroenterostomy (SGE), self-expandable metallic stents (SEMSs) placement, and the advanced technique of endoscopic ultrasound-guided gastroenterostomy (EUS-GE). While surgery is favored for longer life expectancy, stents are preferred in malignant gastric outlet stenosis. The novel EUS-GE technique, employing a lumen-apposing self-expandable metal stent (LAMS), combines the immediate efficacy of stents with the enduring benefits of gastroenterostomy. Despite its promising outcomes, EUS-GE is a technically demanding procedure requiring specialized expertise and facilities.


Subject(s)
Gastric Outlet Obstruction , Gastroenterostomy , Humans , Gastroenterostomy/adverse effects , Gastroenterostomy/methods , Endosonography/adverse effects , Endosonography/methods , Gastric Outlet Obstruction/diagnostic imaging , Gastric Outlet Obstruction/etiology , Gastric Outlet Obstruction/surgery , Pylorus/surgery , Stents/adverse effects , Constriction, Pathologic/complications , Constriction, Pathologic/surgery
16.
Medicina (Kaunas) ; 60(2)2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38399627

ABSTRACT

Choledocholithiasis is one of the most common indications for endoscopic retrograde cholangiopancreatography (ERCP) in daily practice. Although the majority of stones are small and can be easily removed in a single endoscopy session, approximately 10-15% of patients have complex biliary stones, requiring additional procedures for an optimum clinical outcome. A plethora of endoscopic methods is available for the removal of difficult biliary stones, including papillary large balloon dilation, mechanical lithotripsy, and electrohydraulic and laser lithotripsy. In-depth knowledge of these techniques and the emerging literature on them is required to yield the most optimal therapeutic effects. This narrative review aims to describe the definition of difficult bile duct stones based on certain characteristics and streamline their endoscopic retrieval using various modalities to achieve higher clearance rates.


Subject(s)
Choledocholithiasis , Gallstones , Humans , Treatment Outcome , Cholangiopancreatography, Endoscopic Retrograde/methods , Gallstones/surgery , Catheterization/methods , Choledocholithiasis/surgery
17.
Gastrointest Endosc ; 99(6): 1035-1038, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38316225

ABSTRACT

BACKGROUND AND AIMS: The SpyGlass (Boston Scientific, Marlborough, Mass, USA) single-operator cholangioscopy (SOC) system is generally considered to be safe but adds additional risks to those associated with standard ERCP. METHODS: We evaluated adverse events (AEs) associated with the SpyGlass system reported in the U.S. Food and Drug Administration Manufacturer and User Facility Device Experience database between January 2016 and August 2023. RESULTS: From the database, 2311 device problems (SpyGlass DS, 1301; SpyGlass DS II, 1010) were reported. An optical problem was the most reported issue (SpyGlass DS, 83; SpyGlass DS II, 457). Patient-related events were found in 62 of 1743 reports (3.5%): 33 with the SpyGlass DS and 29 with the SpyGlass DS II. The most common AEs were bleeding/hemorrhage followed by perforation; infection, fever, or sepsis; and pancreatitis. CONCLUSIONS: Our findings add to the existing literature and provide a fuller picture of potential problems associated with the SpyGlass SOC.


Subject(s)
Databases, Factual , Endoscopy, Digestive System , Humans , Endoscopy, Digestive System/adverse effects , Endoscopy, Digestive System/methods , Endoscopy, Digestive System/instrumentation , United States , Pancreatitis/etiology , Sepsis/etiology , Equipment Failure , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Cholangiopancreatography, Endoscopic Retrograde/methods , Intestinal Perforation/etiology , United States Food and Drug Administration , Hemorrhage/etiology , Gastrointestinal Hemorrhage/etiology
18.
Endoscopy ; 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38325395

ABSTRACT

BACKGROUND: The gender gap in the authorship of scientific research may affect career advancement. Our aim was to assess the potential gender gap in gastrointestinal (GI) journals. METHODS: A systematic review was performed of the GI literature and ongoing research in the period 2020-2022. A total 10 GI journals and ongoing research on clinicaltrials.gov were selected for review. The gender gap in first and senior authorship was evaluated for each article and ongoing research project. Associations between the gender gap and possible predictors were measured and results are presented as odds ratios (ORs) with 95%CI. RESULTS: The number of first female authors (FFAs) and senior female authors (SFAs) in published articles were 1408/4207 (33.5%) and 911/4207 (21.7%), respectively. There were 781/2654 (29.4%) female principal investigators (PI)s for the ongoing research. On comparison of non-endoscopic vs. endoscopic topics, the latter were associated with the gender gap (hepatology, OR 2.15 [95%CI 1.83-2.55]; inflammatory bowel disease, OR 2.12 [95%CI 1.60-2.45]; upper and lower GI, OR 1.31 [95%CI 1.18-1.73]); as well as the type of article (original article vs. editorial, OR 1.92 [95%CI 1.58-2.33]). The type of research was also associated with the gender gap (clinical vs. preclinical studies, OR 0.88 [95%CI 0.66-0.91]). CONCLUSION: Our results demonstrated a correlation between the gender gap and the design and topic of the research. Future strategies for improving equity in career development in GI endoscopy should focus on closing the gender gap in equity of authorship.

19.
Expert Rev Gastroenterol Hepatol ; 18(1-3): 37-53, 2024.
Article in English | MEDLINE | ID: mdl-38383965

ABSTRACT

INTRODUCTION: Insulinomas are the most common functional pancreatic neuroendocrine tumors (PNETs) that lead to incapacitating hypoglycemia. Guidelines recommend surgical resection as the mainstay of management. However, surgery is fraught with complications, causing significant peri/post-operative morbidity. Since insulinomas are usually benign, solitary, small (<2 cm), and do not need lymphadenectomy, hence, in this regard, endoscopic ultrasound-guided radiofrequency ablation (EUS-RFA) is now being increasingly performed, to circumvent these adverse events and impairment of pancreatic function. AREAS COVERED: A comprehensive literature search was undertaken across various databases (PubMed/MEDLINE, Embase, Scopus), with no language restriction, for relevant articles (case series, reviews, case reports) pertaining to EUS-RFA for insulinoma and PNETs, till October 2023. In this review, we have explicated the role of EUS-RFA for insulinoma management, detailing thoroughly its mechanism of action, EUS-RFA devices with data on its safety and efficacy, and an algorithmic approach for its management. EXPERT OPINION: EUS-RFA is being advocated as a 'mini-invasive' option with the potential to replace surgery as a first-line approach for benign, sporadic, solitary, and small (<2 cm) insulinomas. Under real-time guidance, EUS-RFA has immense precision, is safe, predictable, with acceptable safety profile. Presently, it is being frequently performed for high-risk or inoperable candidates. Current need-of-the-hour is a randomized controlled trial to substantiate its role in the therapeutic algorithm for insulinoma management.


Subject(s)
Insulinoma , Neuroectodermal Tumors, Primitive , Pancreatic Neoplasms , Radiofrequency Ablation , Humans , Insulinoma/diagnostic imaging , Insulinoma/surgery , Insulinoma/complications , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/surgery , Pancreatic Neoplasms/complications , Treatment Outcome , Endosonography , Ultrasonography, Interventional/adverse effects , Neuroectodermal Tumors, Primitive/complications
20.
Medicina (Kaunas) ; 60(1)2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38256350

ABSTRACT

This review article provides a comprehensive overview of the evolving techniques in image-enhanced endoscopy (IEE) for the characterization of colorectal polyps, and the potential of artificial intelligence (AI) in revolutionizing the diagnostic accuracy of endoscopy. We discuss the historical use of dye-spray and virtual chromoendoscopy for the characterization of colorectal polyps, which are now being replaced with more advanced technologies. Specifically, we focus on the application of AI to create a "virtual biopsy" for the detection and characterization of colorectal polyps, with potential for replacing histopathological diagnosis. The incorporation of AI has the potential to provide an evolutionary learning system that aids in the diagnosis and management of patients with the best possible outcomes. A detailed analysis of the literature supporting AI-assisted diagnostic techniques for the detection and characterization of colorectal polyps, with a particular emphasis on AI's characterization mechanism, is provided. The benefits of AI over traditional IEE techniques, including the reduction in human error in diagnosis, and its potential to provide an accurate diagnosis with similar accuracy to the gold standard are presented. However, the need for large-scale testing of AI in clinical practice and the importance of integrating patient data into the diagnostic process are acknowledged. In conclusion, the constant evolution of IEE technology and the potential for AI to revolutionize the field of endoscopy in the future are presented.


Subject(s)
Artificial Intelligence , Colonic Polyps , Humans , Colonic Polyps/diagnostic imaging , Staining and Labeling , Biopsy , Learning
SELECTION OF CITATIONS
SEARCH DETAIL
...