Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-34281105

ABSTRACT

To cope with the shortage of filtering facepiece respirators (FFRs) caused by the coronavirus disease (COVID-19), healthcare institutions have been forced to reuse FFRs using different decontamination methods, including vapor hydrogen peroxide (VHP). However, most healthcare institutions still struggle with evaluating the effect of VHP on filtration efficiency (FE) of the decontaminated FFRs. We developed a low-cost in-house FE assessment using a novel 3D-printed air duct. Furthermore, we assessed the FE of seven types of FFRs. Following 10 VHP cycles, we evaluated the FE of KN95 and 3M-N95 masks. The 3M-N95 and Benehal-N95 masks showed significant lower FE (80.4-91.8%) at fine particle sizes (0.3-1 µm) compared to other FFRs (FE ≥ 98.1%, p < 0.05). Following 10 VHP cycles, the FE of KN95 masks was almost stable (FE stability > 99.1%) for all particle sizes, while 3M-N95 masks were stable only at 2 and 5 µm (FE stability > 98.0%). Statistically, FE stability of 3M-N95 masks at 0.3, 0.5, and 0.7 µm was significantly lower (p ≤ 0.006) than 2 and 5 µm. The in-house FE assessment may be used as an emergency procedure to validate the decontaminated FFRs, as well as a screening option for production control of FFRs. Following VHP cycles, both masks showed high stability at 5 µm, the size of the most suspected droplets implicated in COVID-19 transmission.


Subject(s)
COVID-19 , Respiratory Protective Devices , Decontamination , Equipment Reuse , Filtration , Humans , Hydrogen Peroxide , SARS-CoV-2 , Ventilators, Mechanical
2.
J Crit Care ; 54: 170-174, 2019 12.
Article in English | MEDLINE | ID: mdl-31476652

ABSTRACT

PURPOSE: To develop an Arabic version of Intensive Care Delirium Screening Checklist (ICDSC) and assess its validity and reliability among critically ill patients. MATERIALS AND METHODS: Multicentered study of convenience sample of adult ICU patients. Arabic translation was performed with rigorous back-to-back translation methods. Concurrent validity was established by calculating the sensitivity and specificity of two examiner assessments compared to a psychiatric evaluation. Kappa coefficients describe interrater reliability, whereas Cronbach α and composite reliability depict internal consistency. RESULTS: Three hundred critically ill patients were enrolled. Of these, validity testing was assessed in 180 patients. ICDSC screening was positive for delirium in 11% of enrolled patients. The area under the receiver operator characteristic (ROC) curve is 0.9413, with predicted sensitivity 70% (95% confidence interval [CI]: 60-81%) and specificity 99% (95% CI: 98-100%). The Arabic ICDSC showed acceptable internal consistency (Cronbach α = 0.63 and composite reliability = 0.64). Interrater agreement was excellent (Kappa coefficient [Ò¡] = 0.85). CONCLUSIONS: Arabic ICDSC is a valid and reliable delirium-screening tool among Arabic-speaking ICU population. Future studies could address whether these findings are generalizable to a higher proportion of mechanically ventilated patients, and address acceptability and reliability in other Arabic language critical care settings.


Subject(s)
Critical Care/methods , Delirium/diagnosis , Mass Screening/methods , Psychometrics/instrumentation , Adult , Aged , Checklist , Critical Illness , Cross-Cultural Comparison , Cross-Sectional Studies , Female , Humans , Intensive Care Units , Male , Mass Screening/standards , Middle Aged , Prospective Studies , ROC Curve , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL