Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Main subject
Publication year range
1.
Front Pharmacol ; 12: 682568, 2021.
Article in English | MEDLINE | ID: mdl-34512325

ABSTRACT

Background: Pyrotinib is a novel irreversible pan-ErbB receptor tyrosine kinase inhibitor. Evidence of the efficacy of pyrotinib-based treatments for HER2-positive metastatic breast cancer (MBC) in patients exposed to lapatinib is limited. Methods: Ninety-four patients who received pyrotinib as a third- or higher-line treatment for HER2-positive MBC were included in this retrospective study. The primary and secondary endpoints were overall survival (OS) and progression-free survival (PFS). Propensity score matching (PSM) and inverse probability of treatment weighting (IPTW) analysis were implemented to balance important patient characteristics between groups. Results: Thirty (31.9%) patients were pretreated with lapatinib and subsequently received pyrotinib as an anti-HER2 treatment, and 64 (68.1%) patients did not receive this treatment. The OS and PFS indicated a beneficial trend in lapatinib-naive group compared to lapatinib-treated group in either the original cohort (PFS: 9.02 vs 6.36 months, p = 0.05; OS: 20.73 vs 14.35 months, p = 0.08) or the PSM (PFS: 9.02 vs 6.08 months, p = 0.07; OS: 19.07 vs 18.00 months, p = 0.61) or IPTW (PFS: 9.90 vs 6.17 months, p = 0.05; OS: 19.53 vs 15.10 months, p = 0.08) cohorts. Subgroup analyses demonstrated lapatinib treatment-related differences in PFS in the premenopausal subgroup and the no prior trastuzumab treatment subgroup, but no significant differences were observed in OS. Conclusion: Pyrotinib-based therapy demonstrated promising effects in HER2-positive MBC patients in a real-world study, especially in lapatinib-naive patients, and also some activity in lapatinib-treated patients.

2.
Zhonghua Yi Xue Za Zhi ; 98(16): 1231-1235, 2018 Apr 24.
Article in Chinese | MEDLINE | ID: mdl-29747310

ABSTRACT

Objective: To explore the efficacy and safety of polyethylene glycal recombinant human granulocyte colony-stimulating factor (PEG-rhG-CSF) in preventing chemotherapy-induced neutropenia in patiens with breast cancer. Methods: There were two parts in the present phase Ⅳ clinical study. One was a randomized, controlled clinical study. Patients in this study received PEG-rhG-CSF or rhG-CSF in the first cycle and followed with both PEG-rhG-CSF in the rest of 3 cycles. The other one was a single arm study. Patients who developed Ⅲ/Ⅳ grade neutropenia in the screening cycle received PEG-rhG-CSF in the rest of 3 cycles chemotherapy. Results: In the first cycle of randomized, controlled study, the incidence of Ⅳ grade neutropenia are 31.48% and 35.58% respectively in PEG-rhG-CSF and rhG-CSF group, with no statistically significant differences (P=0.527 6). The duration of Ⅳ grade neutropenia respectively are 2.22±1.58 and 3.00±1.59 days, with a statistically significant difference (P=0.016 6). In the single arm study, the incidence of Ⅳ grade neutropenia was 57.76% in screening cycle. And the incidence decreased to 16.35%, 10%, and 8.57% in the followed 3 cycle after the use of PEG-rhG-CSF. The incidence of adverse effects was 5.06%, and the major adverse effect was bone pain which with an incidence of 2.8%. Conclusion: The fixed 6mg dose of PEG-rhG-CSF can effectively prevent neutropenia in patients with breast cancer in multicycle chemotherapy and it has a low incidence of adverse events and mild adverse reaction.


Subject(s)
Neutropenia/chemically induced , Breast Neoplasms , Granulocyte Colony-Stimulating Factor , Humans , Lung Neoplasms , Polyethylene , Recombinant Proteins
3.
Appl Opt ; 36(13): 2843-7, 1997 May 01.
Article in English | MEDLINE | ID: mdl-18253282

ABSTRACT

In identical exposure and processing conditions, we compare the exposure characteristics of soft-x-ray film, SIOFM-5FW, with Kodak101-05 and Ilford Q-plates in the soft-x-ray and extreme UV region below 100 nm, using D-19 and Phenisol developers. The experimental results show that for radiation greater than 10 nm, the response of SIOFM-5FW lies between the Kodak101-05 and the Ilford Q-plates but is closer to the former. For radiation of less than 10 nm, the SIOFM-5FW is more sensitive than the Kodak101-05 plate, with a higher saturated optical density, a higher dynamic range, and an obvious carbon K absorption edge structure in the spectra obtained. The effects of the two developers used on the exposure characteristics are discussed.

4.
Appl Opt ; 31(31): 6720-3, 1992 Nov 01.
Article in English | MEDLINE | ID: mdl-20733904

ABSTRACT

A stigmatic grazing-incidence flat-field grating spectrograph was developed. The spectrograph consisted of a variable line-spacing concave grating and a grazing-incidence collecting optics composed of a cylindrical mirror and a spherical mirror. Using this spectrograph, we have obtained soft x-ray spectra of line-focused laser plasmas with good spatial resolution along the normal of the target surface over the entire wavelength range covered by the spectrograph.

SELECTION OF CITATIONS
SEARCH DETAIL
...