Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Microdevices ; 26(3): 29, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38888669

ABSTRACT

Subcutaneous delivery of cell therapy is an appealing minimally-invasive strategy for the treatment of various diseases. However, the subdermal site is poorly vascularized making it inadequate for supporting engraftment, viability, and function of exogenous cells. In this study, we developed a 3D bioprinted scaffold composed of alginate/gelatin (Alg/Gel) embedded with mesenchymal stem cells (MSCs) to enhance vascularization and tissue ingrowth in a subcutaneous microenvironment. We identified bio-ink crosslinking conditions that optimally recapitulated the mechanical properties of subcutaneous tissue. We achieved controlled degradation of the Alg/Gel scaffold synchronous with host tissue ingrowth and remodeling. Further, in a rat model, the Alg/Gel scaffold was superior to MSC-embedded Pluronic hydrogel in supporting tissue development and vascularization of a subcutaneous site. While the scaffold alone promoted vascular tissue formation, the inclusion of MSCs in the bio-ink further enhanced angiogenesis. Our findings highlight the use of simple cell-laden degradable bioprinted structures to generate a supportive microenvironment for cell delivery.


Subject(s)
Alginates , Bioprinting , Mesenchymal Stem Cells , Neovascularization, Physiologic , Printing, Three-Dimensional , Tissue Scaffolds , Mesenchymal Stem Cells/cytology , Animals , Tissue Scaffolds/chemistry , Alginates/chemistry , Rats , Gelatin/chemistry , Mesenchymal Stem Cell Transplantation , Cell- and Tissue-Based Therapy , Subcutaneous Tissue , Rats, Sprague-Dawley , Hydrogels/chemistry
2.
BMJ Open ; 14(6): e081933, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38866577

ABSTRACT

INTRODUCTION: Hepatic artery complications (HACs), such as a thrombosis or stenosis, are serious causes of morbidity and mortality after paediatric liver transplantation (LT). This study will investigate the incidence, current management practices and outcomes in paediatric patients with HAC after LT, including early and late complications. METHODS AND ANALYSIS: The HEPatic Artery stenosis and Thrombosis after liver transplantation In Children (HEPATIC) Registry is an international, retrospective, multicentre, observational study. Any paediatric patient diagnosed with HAC and treated for HAC (at age <18 years) after paediatric LT within a 20-year time period will be included. The primary outcomes are graft and patient survivals. The secondary outcomes are technical success of the intervention, primary and secondary patency after HAC intervention, intraprocedural and postprocedural complications, description of current management practices, and incidence of HAC. ETHICS AND DISSEMINATION: All participating sites will obtain local ethical approval and (waiver of) informed consent following the regulations on the conduct of observational clinical studies. The results will be disseminated through scientific presentations at conferences and through publication in peer-reviewed journals. TRIAL REGISTRATION NUMBER: The HEPATIC registry is registered at the ClinicalTrials.gov website; Registry Identifier: NCT05818644.


Subject(s)
Hepatic Artery , Liver Transplantation , Postoperative Complications , Registries , Thrombosis , Humans , Liver Transplantation/adverse effects , Retrospective Studies , Child , Incidence , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Thrombosis/etiology , Thrombosis/epidemiology , Adolescent , Child, Preschool , Female , Male , Constriction, Pathologic/etiology , Infant , Multicenter Studies as Topic
3.
World J Transplant ; 14(1): 88734, 2024 Mar 18.
Article in English | MEDLINE | ID: mdl-38576759

ABSTRACT

BACKGROUND: Biliary atresia (BA) is the most common indication for pediatric liver trans plantation, although portoenterostomy is usually performed first. However, due to the high failure rate of portoenterostomy, liver transplantation has been advocated as the primary procedure for patients with BA. It is still unclear if a previous portoenterostomy has a negative impact on liver transplantation outcomes. AIM: To investigate the effect of prior portoenterostomy in infants un dergoing liver transplantation for BA. METHODS: This was a retrospective cohort study of 42 pediatric patients with BA who underwent primary liver transplantation from 2013 to 2023 at a single tertiary center in Brazil. Patients with BA were divided into two groups: Those under going primary liver transplantation without portoenterostomy and those undergoing liver transplantation with prior portoenterostomy. Continuous variables were compared using the Student's t-test or the Kruskal-Wallis test, and categorical variables were compared using the χ2 or Fisher's exact test, as appropriate. Multivariable Cox regression analysis was performed to determine risk factors for portal vein thrombosis. Patient and graft survival analyses were conducted with the Kaplan-Meier product-limit estimator, and patient subgroups were compared using the two-sided log-rank test. RESULTS: Forty-two patients were included in the study (25 [60%] girls), 23 undergoing liver transplantation without prior portoenterostomy, and 19 undergoing liver transplantation with prior portoenterostomy. Patients with prior portoenterostomy were older (12 vs 8 months; P = 0.02) at the time of liver transplantation and had lower Pediatric End-Stage Liver Disease scores (13.2 vs 21.4; P = 0.01). The majority of the patients (35/42, 83%) underwent living-donor liver transplantation. The group of patients without prior portoenterostomy appeared to have a higher incidence of portal vein thrombosis (39 vs 11%), but this result did not reach statistical significance. Prior portoenterostomy was not a protective factor against portal vein thrombosis in the multivariable analysis after adjusting for age at liver transplantation, graft-to-recipient weight ratio, and use of vascular grafts. Finally, the groups did not significantly differ in terms of post-transplant survival. CONCLUSION: In our study, prior portoenterostomy did not significantly affect the outcomes of liver transplantation.

4.
Eur J Ophthalmol ; : 11206721241236919, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38444247

ABSTRACT

BACKGROUND: recently much studies evidenced the potential role of photo-biomodulation (PBM) in patients affected by Age-related Macular Degeneration (AMD). We designed a new wearable device for self-medication that employs the same broadband red light described in literature, but with extremely low irradiance. AIM: to demonstrate the safety and effectiveness of low-fluence light stimulations emitted by a LED source with appropriate wavelengths through our new device in improving short-term visual function in patients affected by severe non neovascular AMD. MATERIALS AND METHODS: we prospectively enrolled patients affected by severe non-neovascular AMD with a relative sparing of the foveal region. All the patients were randomly assigned in placebo or in treatment group. The treatment consisted of 10 sessions of 10-min each, using the new device comprised of micro-LEDs that emitted light onto an amorphous support assembled within Metallic eyeglasses. The placebo group blindly underwent the same number of PBM sessions with the micro-LED turned off. Before and after each placebo/treatment sessions all the patients received: optical coherence tomography (OCT), Best-Corrected Visual Acuity (BCVA) and Microperimetry (MP). RESULTS: no significant differences in the anatomical parameters were observed in the two groups. The MP mean sensitivity and the central visual function both far and near significantly improved in the treated group (respectively p < 0.001, p < 0.001). CONCLUSIONS: our pivotal demonstrated that the LED PBM delivered through our new device is a safe and effective tool for improving short-term visual function in patients affected by severe non-neovascular AMD.

5.
Phys Eng Sci Med ; 47(2): 385-401, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38231358

ABSTRACT

The power consumption of portable gadgets, implantable medical devices (IMDs) and wireless sensor nodes (WSNs) has reduced significantly with the ongoing progression in low-power electronics and the swift advancement in nano and microfabrication. Energy harvesting techniques that extract and convert ambient energy into electrical power have been favored to operate such low-power devices as an alternative to batteries. Due to the expanded availability of radio frequency (RF) energy residue in the surroundings, radio frequency energy harvesters (RFEHs) for low-power devices have garnered notable attention in recent times. This work establishes a review study of RFEHs developed for the utilization of low-power devices. From the modest single band to the complex multiband circuitry, the work reviews state of the art of required circuitry for RFEH that contains a receiving antenna, impedance matching circuit, and an AC-DC rectifier. Furthermore, the advantages and disadvantages associated with various circuit architectures are comprehensively discussed. Moreover, the reported receiving antenna, impedance matching circuit, and an AC-DC rectifier are also compared to draw conclusions towards their implementations in RFEHs for sensors and biomedical devices applications.


Subject(s)
Electric Power Supplies , Radio Waves , Wireless Technology , Equipment Design , Wireless Technology/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL