Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 89
Filter
1.
J Vasc Interv Radiol ; 35(7): 1043-1048.e3, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38508449

ABSTRACT

PURPOSE: Treatment of hypovascular tumors, such as pancreatic adenocarcinoma, is challenging owing to inefficient drug delivery. This report examines the potential mechanism of localized drug delivery via transarterial microperfusion (TAMP) using a proprietary adjustable double-balloon occlusion catheter in a porcine model. MATERIALS AND METHODS: Adult Yorkshire swine (N = 21) were used in the Institutional Animal Care & Use Committee-approved protocols. The RC-120 catheter (RenovoRx, Los Altos, California) was positioned into visceral, femoral, and pulmonary arteries with infusion of methylene blue dye, gemcitabine, or gold nanoparticles. Transmural delivery was compared under double-balloon occlusion with and without side-branch exclusion, single-balloon occlusion, and intravenous delivery. Intra-arterial pressure and vascular histologic changes were assessed. RESULTS: Infusion with double-balloon occlusion and side-branch exclusion provided increased intra-arterial pressure in the isolated segment and enhanced perivascular infusate penetration with minimal vascular injury. Infusates were predominantly found in the vasa vasorum by electron microscopy. CONCLUSIONS: TAMP enhanced transmural passage mediated by localized increase in arterial pressure via vasa vasorum.


Subject(s)
Vasa Vasorum , Animals , Vasa Vasorum/pathology , Vasa Vasorum/drug effects , Balloon Occlusion , Gemcitabine , Infusions, Intra-Arterial , Deoxycytidine/analogs & derivatives , Deoxycytidine/administration & dosage , Deoxycytidine/pharmacology , Models, Animal , Antineoplastic Agents/administration & dosage , Antineoplastic Agents/pharmacology , Methylene Blue/administration & dosage , Swine , Metal Nanoparticles , Equipment Design , Arterial Pressure/drug effects , Sus scrofa , Vascular Access Devices
2.
J Am Coll Radiol ; 20(11S): S481-S500, 2023 11.
Article in English | MEDLINE | ID: mdl-38040466

ABSTRACT

Lower extremity venous insufficiency is a chronic medical condition resulting from primary valvular incompetence or, less commonly, prior deep venous thrombosis or extrinsic venous obstruction. Lower extremity chronic venous disease has a high prevalence with a related socioeconomic burden. In the United States, over 11 million males and 22 million females 40 to 80 years of age have varicose veins, with over 2 million adults having advanced chronic venous disease. The high cost to the health care system is related to the recurrent nature of venous ulcerative disease, with total treatment costs estimated >$2.5 billion per year in the United States, with at least 20,556 individuals with newly diagnosed venous ulcers yearly. Various diagnostic and treatment strategies are in place for lower extremity chronic venous disease and are discussed in this document. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Subject(s)
Societies, Medical , Vascular Diseases , Female , Humans , Male , Chronic Disease , Diagnostic Imaging/methods , Lower Extremity/diagnostic imaging , United States
3.
Cell Mol Gastroenterol Hepatol ; 16(6): 881-894, 2023.
Article in English | MEDLINE | ID: mdl-37678799

ABSTRACT

Colorectal cancer is the second leading cause of cancer-related deaths in the United States and accounts for an estimated 1 million deaths annually worldwide. The liver is the most common site of metastatic spread from colorectal cancer, significantly driving both morbidity and mortality. Although remarkable advances have been made in recent years in the management for patients with colorectal cancer liver metastases, significant challenges remain in early detection, prevention of progression and recurrence, and in the development of more effective therapeutics. In 2017, our group held a multidisciplinary state-of-the-science symposium to discuss the rapidly evolving clinical and scientific advances in the field of colorectal liver metastases, including novel early detection and prognostic liquid biomarkers, identification of high-risk cohorts, advances in tumor-immune therapy, and different regional and systemic therapeutic strategies. Since that time, there have been scientific discoveries translating into therapeutic innovations addressing the current management challenges. These innovations are currently reshaping the treatment paradigms and spurring further scientific discovery. Herein, we present an updated discussion of both the scientific and clinical advances and future directions in the management of colorectal liver metastases, including adoptive T-cell therapies, novel blood-based biomarkers, and the role of the tumor microbiome. In addition, we provide a comprehensive overview detailing the role of modern multidisciplinary clinical approaches used in the management of patients with colorectal liver metastases, including considerations toward specific molecular tumor profiles identified on next generation sequencing, as well as quality of life implications for these innovative treatments.


Subject(s)
Colorectal Neoplasms , Liver Neoplasms , Humans , Quality of Life , Liver Neoplasms/therapy , Biomarkers , Colorectal Neoplasms/therapy
4.
J Vasc Interv Radiol ; 34(11): 1958-1962.e1, 2023 11.
Article in English | MEDLINE | ID: mdl-37451538

ABSTRACT

During endovascular interventions, coaxial deployment of stents may be required to preserve luminal gain. This study characterized in vitro the effect on crush resistance and postcompression recovery when 316L stainless steel balloon-expandable (BE) and laser-cut nitinol self-expanding (SE) venous stents were deployed coaxially. Various stent configurations were parallel-plate compressed from a fully expanded state to 50% diameter reduction (Criterion, Model 42; MTS, Eden Prairie, Minnesota) in a 37 °C ± 1 water bath. Coaxial deployments of SE stent inside BE stent and BE stent inside SE stent demonstrated higher crush resistances compared with each stent individually or their mathematical summation (analysis of variance P < .0001; pairwise comparison P < .01). The configuration of SE stent inside BE stent showed higher postcompression luminal recovery at 48.7% compared with that of BE stent inside SE stent at 27.5% (P = .0001). Coaxial deployment of SE stent inside BE stent may improve crush resistance and luminal recovery after compression in the appropriate clinical context.


Subject(s)
Alloys , Stents , Humans , Minnesota , Prosthesis Design
5.
J Vasc Interv Radiol ; 34(9): 1511-1515.e1, 2023 09.
Article in English | MEDLINE | ID: mdl-37196821

ABSTRACT

Double-barrel stent placement across the iliocaval confluence is commonly used for the treatment of chronic bilateral iliocaval occlusion. The difference in the deployment outcomes of synchronous parallel stent deployment versus asynchronous or antiparallel deployment and the underlying stent interactions are poorly understood. In this study, 3 strategies of double-barrel nitinol self-expanding stent deployment across the iliocaval confluence (synchronous parallel, asynchronous parallel, and synchronous antiparallel) were contrasted in vivo in 3 swine followed by assessment of the explanted stent construct. Synchronous parallel stent deployment achieved a desired double-barrel configuration. The asynchronous parallel and antiparallel deployment strategies both resulted in a crushed stent despite subsequent simultaneous balloon angioplasty. These animal model results suggested that in patients who undergo double-barrel iliocaval reconstruction, synchronous parallel stent deployment may provide the desired stent conformation and increase the chance for clinical success.


Subject(s)
Alloys , Stents , Animals , Swine , Treatment Outcome , Vascular Patency
6.
AJR Am J Roentgenol ; 220(6): 863-872, 2023 06.
Article in English | MEDLINE | ID: mdl-36752368

ABSTRACT

Hepatocellular carcinoma (HCC) is the most prevalent primary liver cancer and the fourth most common cause of cancer mortality. The tumor microenvironment is increasingly recognized as having a central role in HCC carcinogenesis; factors such as tumor and immune cell interactions, cytokines, and extracellular matrix have key roles. Transarterial radioembolization (TARE) is a locoregional therapy for HCC that not only has a direct tumoricidal effect but also induces an immune response against tumor cells with subsequent immunogenic cell death. This TARE-induced tumor immunogenicity occurs through enhancement of tumor-associated antigen expression and recruitment and diversification of tumor-infiltrating lymphocytes. In addition, immunologic biomarkers, including neutrophil-to-lymphocyte ratio, lymphocyte count, and cytokine levels, may be useful for predicting outcomes after TARE. Early data are promising regarding the potential synergistic benefit of treatment algorithms that combine TARE and immunotherapies, and interest is growing in the clinical application of such combinations. The purpose of this article is to provide an overview of cancer immunology, summarize the available data on the biologic effects of TARE on local and systemic immune responses, and explore the potential role of the combination of TARE and immunotherapy for HCC.


Subject(s)
Carcinoma, Hepatocellular , Chemoembolization, Therapeutic , Liver Neoplasms , Humans , Carcinoma, Hepatocellular/radiotherapy , Liver Neoplasms/radiotherapy , Yttrium Radioisotopes/therapeutic use , Immunity , Tumor Microenvironment
7.
J Vasc Interv Radiol ; 34(2): 182-186, 2023 02.
Article in English | MEDLINE | ID: mdl-36414116

ABSTRACT

To compare public popularity and volume of scientific publications regarding uterine fibroid embolization (UFE) and myomectomy. Google Trends and PubMed data were queried to assess temporal variations in online public search volumes and number of research publications for UFE and myomectomy. Time series analysis was used to identify meaningful temporal trends and forecast a future trend. Compared with UFE, myomectomy had significantly higher volumes of public online search and research publications, with an increasing trend over time (P < .0001). The forecasting models predicted a continuing increase in both public search volumes and number of research publications for myomectomy and static future trends in these metrics for UFE. This study signals significantly lower public popularity and research efforts for UFE compared with myomectomy for uterine fibroids. More effective marketing strategies and further research support will be needed to fill this gap.


Subject(s)
Embolization, Therapeutic , Leiomyoma , Uterine Myomectomy , Uterine Neoplasms , Female , Humans , Uterine Myomectomy/adverse effects , Uterine Neoplasms/surgery , Search Engine , Leiomyoma/surgery , Embolization, Therapeutic/adverse effects , Marketing
8.
Cancer ; 129(2): 184-214, 2023 01 15.
Article in English | MEDLINE | ID: mdl-36382577

ABSTRACT

Cholangiocarcinoma is a lethal malignancy of the biliary epithelium that can arise anywhere along the biliary tract. Surgical resection confers the greatest likelihood of long-term survivability. However, its insidious onset, difficult diagnostics, and resultant advanced presentation render the majority of patients unresectable, highlighting the importance of early detection with novel biomarkers. Developing liver-directed therapies and emerging targeted therapeutics may offer improved survivability for patients with unresectable or advanced disease. In this article, the authors review the current multidisciplinary standards of care in resectable and unresectable cholangiocarcinoma, with an emphasis on novel biomarkers for early detection and nonsurgical locoregional therapy options.


Subject(s)
Bile Duct Neoplasms , Cholangiocarcinoma , Humans , Bile Ducts, Intrahepatic/pathology , Bile Duct Neoplasms/therapy , Bile Duct Neoplasms/pathology , Cholangiocarcinoma/therapy , Cholangiocarcinoma/pathology
9.
Small Methods ; 6(12): e2200916, 2022 12.
Article in English | MEDLINE | ID: mdl-36319445

ABSTRACT

Due to the limited heating efficiency of available magnetic nanoparticles, it is difficult to achieve therapeutic temperatures above 44 °C in relatively inaccessible tumors during magnetic hyperthermia following systemic administration of nanoparticles at clinical dosage (≤10 mg kg-1 ). To address this, a method for the preparation of magnetic nanoparticles with ultrahigh heating capacity in the presence of an alternating magnetic field (AMF) is presented. The low nitrogen flow rate of 10 mL min-1 during the thermal decomposition reaction results in cobalt-doped nanoparticles with a magnetite (Fe3 O4 ) core and a maghemite (γ-Fe2 O3 ) shell that exhibit the highest intrinsic loss power reported to date of 47.5 nH m2 kg-1 . The heating efficiency of these nanoparticles correlates positively with increasing shell thickness, which can be controlled by the flow rate of nitrogen. Intravenous injection of nanoparticles at a low dose of 4 mg kg-1 elevates intratumoral temperatures to 50 °C in mice-bearing subcutaneous and metastatic cancer grafts during exposure to AMF. This approach can also be applied to the synthesis of other metal-doped nanoparticles with core-shell structures. Consequently, this method can potentially be used for the development of novel nanoparticles with high heating performance, further advancing systemic magnetic hyperthermia for cancer treatment.


Subject(s)
Hyperthermia, Induced , Magnetite Nanoparticles , Neoplasms , Mice , Animals , Magnetite Nanoparticles/therapeutic use , Hyperthermia, Induced/methods , Heating , Magnetic Fields , Hyperthermia , Neoplasms/therapy , Nitrogen
10.
Cardiovasc Intervent Radiol ; 45(8): 1064-1073, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35737099

ABSTRACT

OBJECTIVE: There is no classification system for describing inferior vena cava (IVC) injuries. The objective of this study was to develop a standardized grading system for venographic appearance of the IVC following percutaneous IVC filter retrieval. METHODS: A classification system for the appearance of the IVC on cavograms following percutaneous IVC filter removal was developed consisting of two grading elements; luminal characteristics and extravasation. Luminal narrowing from 0% up to 50% from any cause is grade 1; narrowing between 50 and 99% is grade 2; occlusion is grade 3; and avulsion is grade 4. Absence of extravasation is grade A, contained extravasation is grade B, and free extravasation is grade C. This system was then applied retrospectively to pre- and post-IVC filter retrieval cavograms performed at a single institution from October 2004 through February 2019. RESULTS: 546 retrieval attempts were identified with 509 (93.2%) filters successfully retrieved. 449 cases (88.2%) had both pre-retrieval and post-retrieval imaging appropriate for application of the proposed classification system. Inter-rater reliability was 0.972 for luminal characteristics, 0.967 for extravasation, and 0.969 overall. Consensus grading demonstrated a distribution of 97.3% grade 1, 1.3% grade 2, 1.3% grade 3, and 0.0% grade 4 for post-retrieval luminal characteristics. For extravasation classification, 96.4% of the cases were classified as grade A, 2.7% grade B, and 0.9% grade C. CONCLUSION: A classification system was developed for describing IVC appearance after IVC filter retrieval, and retrospectively validated using a single center dataset.


Subject(s)
Vena Cava Filters , Vena Cava, Inferior , Device Removal/methods , Humans , Reproducibility of Results , Retrospective Studies , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery
11.
NPJ Precis Oncol ; 6(1): 28, 2022 Apr 25.
Article in English | MEDLINE | ID: mdl-35468987

ABSTRACT

Cell-free RNA (cfRNA) in plasma reflects phenotypic alterations of both localized sites of cancer and the systemic host response. Here we report that cfRNA sequencing enables the discovery of messenger RNA (mRNA) biomarkers in plasma with the tissue of origin-specific to cancer types and precancerous conditions in both solid and hematologic malignancies. To explore the diagnostic potential of total cfRNA from blood, we sequenced plasma samples of eight hepatocellular carcinoma (HCC) and ten multiple myeloma (MM) patients, 12 patients of their respective precancerous conditions, and 20 non-cancer (NC) donors. We identified distinct gene sets and built classification models using Random Forest and linear discriminant analysis algorithms that could distinguish cancer patients from premalignant conditions and NC individuals with high accuracy. Plasma cfRNA biomarkers of HCC are liver-specific genes and biomarkers of MM are highly expressed in the bone marrow compared to other tissues and are related to cell cycle processes. The cfRNA level of these biomarkers displayed a gradual transition from noncancerous states through precancerous conditions and cancer. Sequencing data were cross-validated by quantitative reverse transcription PCR and cfRNA biomarkers were validated in an independent sample set (20 HCC, 9 MM, and 10 NC) with AUC greater than 0.86. cfRNA results observed in precancerous conditions require further validation. This work demonstrates a proof of principle for using mRNA transcripts in plasma with a small panel of genes to distinguish between cancers, noncancerous states, and precancerous conditions.

12.
Small ; 18(24): e2107808, 2022 06.
Article in English | MEDLINE | ID: mdl-35434932

ABSTRACT

Endometriosis is a devastating disease in which endometrial-like tissue forms lesions outside the uterus. It causes infertility and severe pelvic pain in ≈176 million women worldwide, and there is currently no cure for this disease. Magnetic hyperthermia could potentially eliminate widespread endometriotic lesions but has not previously been considered for treatment because conventional magnetic nanoparticles have relatively low heating efficiency and can only provide ablation temperatures (>46 °C) following direct intralesional injection. This study is the first to describe nanoparticles that enable systemically delivered magnetic hyperthermia for endometriosis treatment. When subjected to an alternating magnetic field (AMF), these hexagonal iron-oxide nanoparticles exhibit extraordinary heating efficiency that is 6.4× greater than their spherical counterparts. Modifying nanoparticles with a peptide targeted to vascular endothelial growth factor receptor 2 (VEGFR-2) enhances their endometriosis specificity. Studies in mice bearing transplants of macaque endometriotic tissue reveal that, following intravenous injection at a low dose (3 mg per kg), these nanoparticles efficiently accumulate in endometriotic lesions, selectively elevate intralesional temperature above 50 °C upon exposure to external AMF, and completely eradicate them with a single treatment. These nanoparticles also demonstrate promising potential as magnetic resonance imaging (MRI) contrast agents for precise detection of endometriotic tissue before AMF application.


Subject(s)
Endometriosis , Hyperthermia, Induced , Magnetite Nanoparticles , Nanoparticles , Animals , Contrast Media , Endometriosis/therapy , Female , Heating , Humans , Hyperthermia, Induced/methods , Magnetic Fields , Mice , Vascular Endothelial Growth Factor A
13.
Liver Transpl ; 28(10): 1651-1663, 2022 10.
Article in English | MEDLINE | ID: mdl-35253365

ABSTRACT

Patients with acute and chronic liver disease present with a wide range of disease states and severity that may require liver transplantation (LT). Physiologic alterations occur that are dynamic throughout all phases of perioperative care, creating complex management scenarios that necessitate multidisciplinary clinical care. Specifically, alterations in hemostasis in liver disease can be pronounced and evolve with disease progression over time. Recent studies and society guidance address this emerging paradigm and offer recommendations to assist with hemostatic management in patients with liver disease. However, patients undergoing LT are unique and diverse, often with unstable disease that requires specialized approaches. Our aim is to provide a focused review of hemostatic management of the LT patient, distinguish unique aspects of the three main phases of care (before LT, perioperative, and after LT), and identify knowledge gaps and critical areas of future research.


Subject(s)
Blood Coagulation Disorders , Hemostatics , Liver Diseases , Liver Transplantation , Blood Coagulation Disorders/diagnosis , Blood Coagulation Disorders/etiology , Blood Coagulation Disorders/therapy , Hemostasis/physiology , Humans , Liver Diseases/complications , Liver Diseases/surgery , Liver Transplantation/adverse effects
14.
J Vasc Interv Radiol ; 33(3): 262-267, 2022 03.
Article in English | MEDLINE | ID: mdl-35221046

ABSTRACT

This study characterized the impact of vein wall biomechanics on inflow diameter and luminal flow during venous angioplasty and stent placement, using postthrombotic and healthy biomechanical properties from an ovine venous stenosis and thrombosis model. Finite element analysis demonstrated more pronounced inflow channel narrowing in the postthrombotic vein compared with the healthy control vein during angioplasty and stent placement (relative inflow diameter reduction of 42% versus 13%, P < .0001). Computational fluid dynamics modeling showed increased relative areas of low wall shear rate in the postthrombotic vein compared with the normal vein (0.46 vs 0.24 for shear rate < 50 s-1; 0.13 vs 0.07 for shear rate < 15 s-1; P < .05), with flow stagnation and recirculation. Since inflow narrowing and low wall shear rate are associated with in-stent restenosis and reintervention, these computational results based on experimentally obtained biomechanical values highlight the significance of postthrombotic venous properties in optimizing venous intervention outcomes.


Subject(s)
Iliac Vein , Stents , Angioplasty , Animals , Biomechanical Phenomena , Computer Simulation , Humans , Sheep , Treatment Outcome
15.
Clin Gastroenterol Hepatol ; 20(8): 1636-1662.e36, 2022 08.
Article in English | MEDLINE | ID: mdl-34274511

ABSTRACT

Complications of portal hypertension, including ascites, gastrointestinal bleeding, hepatic hydrothorax, and hepatic encephalopathy, are associated with significant morbidity and mortality. Despite few high-quality randomized controlled trials to guide therapeutic decisions, transjugular intrahepatic portosystemic shunt (TIPS) creation has emerged as a crucial therapeutic option to treat complications of portal hypertension. In North America, the decision to perform TIPS involves gastroenterologists, hepatologists, and interventional radiologists, but TIPS creation is performed by interventional radiologists. This is in contrast to other parts of the world where TIPS creation is performed primarily by hepatologists. Thus, the successful use of TIPS in North America is dependent on a multidisciplinary approach and technical expertise, so as to optimize outcomes. Recently, new procedural techniques, TIPS stent technology, and indications for TIPS have emerged. As a result, practices and outcomes vary greatly across institutions and significant knowledge gaps exist. In this consensus statement, the Advancing Liver Therapeutic Approaches group critically reviews the application of TIPS in the management of portal hypertension. Advancing Liver Therapeutic Approaches convened a multidisciplinary group of North American experts from hepatology, interventional radiology, transplant surgery, nephrology, cardiology, pulmonology, and hematology to critically review existing literature and develop practice-based recommendations for the use of TIPS in patients with any cause of portal hypertension in terms of candidate selection, procedural best practices and, post-TIPS management; and to develop areas of consensus for TIPS indications and the prevention of complications. Finally, future research directions are identified related to TIPS for the management of portal hypertension.


Subject(s)
Esophageal and Gastric Varices , Hypertension, Portal , Portasystemic Shunt, Transjugular Intrahepatic , Ascites/etiology , Esophageal and Gastric Varices/complications , Gastrointestinal Hemorrhage/complications , Gastrointestinal Hemorrhage/surgery , Humans , Hypertension, Portal/complications , Hypertension, Portal/surgery , Portasystemic Shunt, Transjugular Intrahepatic/adverse effects , Treatment Outcome
16.
J Vasc Interv Radiol ; 33(3): 255-261.e2, 2022 03.
Article in English | MEDLINE | ID: mdl-34915165

ABSTRACT

PURPOSE: To characterize an ovine endovascular radiofrequency (RF) ablation-based venous stenosis and thrombosis model for studying venous biomechanics and response to intervention. MATERIALS AND METHODS: Unilateral short-segment (n = 2) or long-segment (n = 6) iliac vein stenoses were created in 8 adult sheep using an endovenous RF ablation technique. Angiographic assessment was performed at baseline, immediately after venous stenosis creation, and after 2-week (n = 6) or 3-month (n = 2) survival. Stenosed iliac veins and the contralateral healthy controls were harvested for histological and biomechanical assessment. RESULTS: At follow-up, the short-segment RF ablation group showed stable stenosis without occlusion. The long-segment group showed complete venous occlusion/thrombosis with the formation of collateral veins. Stenosed veins showed significant wall thickening (0.28 vs 0.16 mm, P = .0175) and confluent collagen deposition compared with the healthy controls. Subacute nonadherent thrombi were apparent at 2 weeks, which were replaced by fibrous luminal obliteration with channels of recanalization at 3 months. Stenosed veins demonstrated increased longitudinal stiffness (448.5 ± 5.4 vs 314.6 ± 1.5 kPa, P < .0001) and decreased circumferential stiffness (140.8 ± 2.6 vs 246.0 ± 1.6 kPa, P < .0001) compared with the healthy controls. CONCLUSION: Endovenous RF ablation is a reliable technique for creating venous stenosis and thrombosis in a large animal model with histological and biomechanical attributes similar to those seen in humans. This platform can facilitate understanding of venous biomechanics and testing of venous-specific devices and interventions.


Subject(s)
Catheter Ablation , Vascular Diseases , Venous Insufficiency , Venous Thrombosis , Animals , Catheter Ablation/methods , Constriction, Pathologic/surgery , Humans , Saphenous Vein/surgery , Sheep , Treatment Outcome , Vascular Diseases/surgery , Venous Insufficiency/surgery , Venous Thrombosis/surgery
17.
Diagn Interv Radiol ; 27(5): 644-648, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34559049

ABSTRACT

PURPOSE: We aimed to determine if lateral inferior vena cava (IVC) filter tilt at placement predicts the need for subsequent advanced retrieval techniques. METHODS: A retrospective chart review was performed of all Gunther Tulip IVC filter placements with subsequent retrievals between February 2015 and October 2017. Chart and imaging review was performed for patient, filter placement, and filter retrieval demographics/characteristics. Degree of agreement between two measurement sets was evaluated with the intraclass correlation (ICC) analysis. Categorical variables were compared with chi-square or Fisher exact test, as appropriate. Kendall rank correlation was used to measure correlation between categorical variables. RESULTS: There was poor agreement between filter tilt angle at the time of placement and retrieval (ICC coefficient, 0.54). Mean difference ± standard deviation between tilt angle at the time of placement and retrieval was 4.6°±4.3° (p = 0.35). Among patient- or procedure-related factors, a common femoral vein access on placement (regression coefficient, -2.90; p = 0.039) was associated with a lower difference between placement and retrieval filter tilt angles compared to internal jugular vein access. Higher filter tilt angle measured at the time of retrieval (OR: 1.19, p = 0.025), hook embedment (OR: 77.3, p < 0.001), and a longer dwell time (OR: 1.25, p = 0.002) were associated with the need for advanced retrieval techniques. However, in univariate and multivariate analysis filter tilt angle at the time of placement was not associated with the subsequent need for advanced retrieval technique (p = 0.16). CONCLUSION: Lateral tilt at the time of placement is poorly associated with lateral tilt at the time of retrieval and does not correlate with the need for advanced retrieval technique.


Subject(s)
Device Removal , Vena Cava Filters , Femoral Vein , Humans , Retrospective Studies , Risk Factors , Treatment Outcome , Vena Cava, Inferior/diagnostic imaging
18.
J Hepatocell Carcinoma ; 8: 1181-1193, 2021.
Article in English | MEDLINE | ID: mdl-34589446

ABSTRACT

Percutaneous ablation is a mainstay of treatment for early stage, unresectable hepatocellular carcinoma (HCC). Recent advances in technology have created multiple ablative modalities for treatment of this common malignancy. The purpose of this review is to familiarize readers with the technical and clinical aspects of both existing and emerging percutaneous treatment options for HCC.

19.
Ann Transl Med ; 9(14): 1194, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34430635

ABSTRACT

The spleen is a commonly injured organ in blunt abdominal trauma. Splenic preservation, however, is important for immune function and prevention of overwhelming infection from encapsulated organisms. Splenic artery embolization (SAE) for high-grade splenic injury has, therefore, increasingly become an important component of non-operative management (NOM). SAE decreases the blood pressure to the spleen to allow healing, but preserves splenic perfusion via robust collateral pathways. SAE can be performed proximally in the main splenic artery, more distally in specific injured branches, or a combination of both proximal and distal embolization. No definitive evidence from available data supports benefits of one strategy over the other. Particles, coils and vascular plugs are the major embolic agents used. Incorporation of SAE in the management of blunt splenic trauma has significantly improved success rates of NOM and spleen salvage. Failure rates generally increase with higher injury severity grades; however, current management results in overall spleen salvage rates of over 85%. Complication rates are low, and primarily consist of rebleeding, parenchymal infarction or abscess. Splenic immune function is felt to be preserved after embolization with no guidelines for prophylactic vaccination against encapsulated bacteria; however, a complete understanding of post-embolization immune changes remains an area in need of further investigation. This review describes the history of SAE from its inception to its current role and indications in the management of splenic trauma. The endovascular approach, technical details, and outcomes are described with relevant examples. SAE is has become an important part of a multidisciplinary strategy for management of complex trauma patients.

20.
J Am Coll Radiol ; 18(5S): S139-S152, 2021 May.
Article in English | MEDLINE | ID: mdl-33958109

ABSTRACT

Diverticulosis remains the commonest cause for acute lower gastrointestinal tract bleeding (GIB). Conservative management is initially sufficient for most patients, followed by elective diagnostic tests. However, if acute lower GIB persists, it can be investigated with colonoscopy, CT angiography (CTA), or red blood cell (RBC) scan. Colonoscopy can identify the site and cause of bleeding and provide effective treatment. CTA is a noninvasive diagnostic tool that is better tolerated by patients, can identify actively bleeding site or a potential bleeding lesion in vast majority of patients. RBC scan can identify intermittent bleeding, and with single-photon emission computed tomography, can more accurately localize it to a small segment of bowel. If patients are hemodynamically unstable, CTA and transcatheter arteriography/embolization can be performed. Colonoscopy can also be considered in these patients if rapid bowel preparation is feasible. Transcatheter arteriography has a low rate of major complications; however, targeted transcatheter embolization is only feasible if extravasation is seen, which is more likely in hemodynamically unstable patients. If bleeding site has been previously localized but the intervention by colonoscopy and transcatheter embolization have failed to achieve hemostasis, surgery may be required. Among patients with obscure (nonlocalized) recurrent bleeding, capsule endoscopy and CT enterography can be considered to identify culprit mucosal lesion(s). The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Subject(s)
Radiology , Societies, Medical , Gastrointestinal Hemorrhage/diagnostic imaging , Gastrointestinal Hemorrhage/therapy , Humans , Lower Gastrointestinal Tract/diagnostic imaging , Tomography, X-Ray Computed , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...