ABSTRACT

PURPOSE: Glistening formation in the intraocular lens (IOL) optic has the potential to impact quality of vision. The enVista One-Piece Hydrophobic Acrylic Spherical IOL Model MX60 (MX60 IOL) is currently the only US Food and Drug Administration-approved IOL with a label of "no glistenings". The purpose of this prospective, multicenter, partially randomized, partially controlled, double-masked, pivotal study was to evaluate the safety and effectiveness of the enVista One-Piece Hydrophobic Acrylic MX60T Toric IOL (enVista MX60T Toric IOL). PATIENTS AND METHODS: Subjects (n=191) were implanted with the enVista MX60T Toric IOL (cylinder powers 1.25, 2.00, or 2.75 D) or the parent MX60 IOL (control). Eyes within the lowest range of corneal astigmatism were randomized to receive either Toric 1.25 D IOL or control IOL in a 1:1 ratio. All subjects with corneal astigmatism requiring 2.00 or 2.75 D cylinder IOLs received toric IOLs. Rotational stability, cylinder reduction, and best-corrected distance visual acuity were primary effectiveness endpoints measured at Visit 4 (120-180 days postoperatively). RESULTS: Visit 4 mean absolute axis misalignment in the All Toric group was 4.68°±7.33°, and all subjects had ≤5° absolute rotation from Visit 3 to Visit 4. The 1.25 D group had significantly greater improvement in dioptric cylinder reduction (P<0.001), percent cylinder reduction (P<0.001), and mean uncorrected distance visual acuity (P<0.001), compared to control at Visit 4. Most adverse events (AEs) were mild, with no serious AEs in the study eyes. The rates of cumulative AEs through Visit 4 were below International Organization for Standardization (ISO) standard 11979-7 AE rates. CONCLUSION: enVista MX60T Toric IOL is safe and effective for patients with preoperative corneal astigmatism undergoing IOL implantation.

2.
J Cataract Refract Surg ; 41(2): 295-305, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25661122

ABSTRACT

PURPOSE: To evaluate the safety and effectiveness of the Trulign toric intraocular lens (IOL) in adults with cataract. SETTING: Eight private practices in the United States and 1 in Canada. DESIGN: Prospective randomized single-masked multicenter study. METHODS: A toric IOL (1.25 D, 2.00 D, or 2.75 D, determined by a toric calculator) was implanted in eligible patients with age-related cataract requiring a 16.00 to 27.00 diopter (D) spherical IOL power and with a predicted postoperative astigmatism of 0.83 to 2.50 D. Eyes within the lowest cylinder range (predicted postoperative astigmatism 0.83 to 1.32 D) were randomized in a 1:1 ratio between the 1.25 D toric IOL group and the nontoric accommodating IOL (Crystalens) control group. RESULTS: The toric 1.25 D group had a statistically significantly greater percentage reduction in absolute cylinder (P < .001) and uncorrected distance visual acuity (P = .002) than the control group at the 120- to 180-day visit. The mean monocular uncorrected vision at distance, intermediate, and near was 20/25, 20/22, and 20/39, respectively, with the 1.25 D, 2.00 D, and 2.75 D toric IOLs in aggregate (toric group). In addition, 96.1% of patients (123/128) had 5.0 degrees or less absolute IOL rotation postoperatively. Regarding safety, the endpoints for preservation of corrected visual acuity and the incidence of complications and adverse events were met. CONCLUSION: The toric IOL was safe and effective in reducing the effects of preoperative corneal astigmatism and provided excellent uncorrected distance and intermediate vision and functional near vision. FINANCIAL DISCLOSURES: Dr. Pepose is a consultant to Bausch & Lomb and was medical monitor of this study. Drs. Buckhurst, Whitman, Feinerman, Hovanesian, Davies, Labor, and Carter are consultants to Bausch & Lomb. At the time of the study, Drs. Hayashida, and Khodai were employees of Bausch & Lomb. Drs. Colvard and Mittleman have financial or proprietary interest in any material or method mentioned.


Subject(s)
Biocompatible Materials , Lens Implantation, Intraocular , Lenses, Intraocular , Phacoemulsification , Presbyopia/surgery , Silicone Elastomers , Aged , Aged, 80 and over , Astigmatism/surgery , Cataract/complications , Equipment Safety , Female , Humans , Male , Middle Aged , Presbyopia/complications , Prospective Studies , Prosthesis Design , Refraction, Ocular/physiology , Single-Blind Method , Treatment Outcome , Visual Acuity/physiology