Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Eur Radiol ; 34(1): 422-432, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37566266

ABSTRACT

OBJECTIVES: In this study, we developed a radiomic signature for the classification of benign lipid-poor adenomas, which may potentially help clinicians limit the number of unnecessary investigations in clinical practice. Indeterminate adrenal lesions of benign and malignant nature may exhibit different values of key radiomics features. METHODS: Patients who had available histopathology reports and a non-contrast-enhanced CT scan were included in the study. Radiomics feature extraction was done after the adrenal lesions were contoured. The primary feature selection and prediction performance scores were calculated using the least absolute shrinkage and selection operator (LASSO). To eliminate redundancy, the best-performing features were further examined using the Pearson correlation coefficient, and new predictive models were created. RESULTS: This investigation covered 50 lesions in 48 patients. After LASSO-based radiomics feature selection, the test dataset's 30 iterations of logistic regression models produced an average performance of 0.72. The model with the best performance, made up of 13 radiomics features, had an AUC of 0.99 in the training phase and 1.00 in the test phase. The number of features was lowered to 5 after performing Pearson's correlation to prevent overfitting. The final radiomic signature trained a number of machine learning classifiers, with an average AUC of 0.93. CONCLUSIONS: Including more radiomics features in the identification of adenomas may improve the accuracy of NECT and reduce the need for additional imaging procedures and clinical workup, according to this and other recent radiomics studies that have clear points of contact with current clinical practice. CLINICAL RELEVANCE STATEMENT: The study developed a radiomic signature using unenhanced CT scans for classifying lipid-poor adenomas, potentially reducing unnecessary investigations that scored a final accuracy of 93%. KEY POINTS: • Radiomics has potential for differentiating lipid-poor adenomas and avoiding unnecessary further investigations. • Quadratic mean, strength, maximum 3D diameter, volume density, and area density are promising predictors for adenomas. • Radiomics models reach high performance with average AUC of 0.95 in the training phase and 0.72 in the test phase.


Subject(s)
Adrenocortical Adenoma , Radiomics , Humans , Benchmarking , Tomography, X-Ray Computed , Lipids , Retrospective Studies
2.
Cancers (Basel) ; 14(8)2022 Apr 08.
Article in English | MEDLINE | ID: mdl-35454793

ABSTRACT

Prostate cancer (PCa) risk categorization based on clinical/PSA testing results in a substantial number of men being overdiagnosed with indolent, early-stage PCa. Clinically non-significant PCa is characterized as the presence of ISUP grade one, where PCa is found in no more than two prostate biopsy cores.MRI-ADC and [68Ga]Ga-PSMA-11 PET have been proposed as tools to predict ISUP grade one patients and consequently reduce overdiagnosis. In this study, Radiomics analysis is applied to MRI-ADC and [68Ga]Ga-PSMA-11 PET maps to quantify tumor characteristics and predict histology-proven ISUP grades. ICC was applied with a threshold of 0.6 to assess the features' stability with variations in contouring. Logistic regression predictive models based on imaging features were trained on 31 lesions to differentiate ISUP grade one patients from ISUP two+ patients. The best model based on [68Ga]Ga-PSMA-11 PET returned a prediction efficiency of 95% in the training phase and 100% in the test phase whereas the best model based on MRI-ADC had an efficiency of 100% in both phases. Employing both imaging modalities, prediction efficiency was 100% in the training phase and 93% in the test phase. Although our patient cohort was small, it was possible to assess that both imaging modalities add information to the prediction models and show promising results for further investigations.

3.
J Sports Sci Med ; 21(1): 58-67, 2022 03.
Article in English | MEDLINE | ID: mdl-35250334

ABSTRACT

Triathlon's popularity is rapidly increasing, and epidemiological data relating to its related medical conditions is crucial to the development of proper medical plans and safety guidelines for it. This study examined the data from the medical reports collected during three consecutive editions of Ironman Italy, from 2017 to 2019. Out of 10,653 race-starters, 3.3% required medical attention sustaining 472 medical conditions. A significantly higher injury risk was found for females versus males (χ2 = 9.78, p = 0.02) and in long-distance (IR: 4.09/1,000hours) rather than in Olympic/middle distance races (IR: 1.75/1,000hours). Most (68.4%) conditions (including muscular exhaustion, hypothermia, and dehydration) were systemic, whilst only 10.2% were acute traumatic injuries. Of a total of 357 triathletes requiring medical assistance, 8.1% were a candidate for hospitalisation. The equipment and personnel that are required for the medical assistance in future triathlon events were estimated based on Maurer's algorithm, and ten practical recommendations for triathlon medical support were formulated.


Subject(s)
Running , Bicycling/injuries , Female , Humans , Male , Retrospective Studies , Running/injuries , Swimming/injuries
4.
Cancers (Basel) ; 14(1)2022 Jan 04.
Article in English | MEDLINE | ID: mdl-35008404

ABSTRACT

The purpose of this study is to discuss how to use an external radio-opaque template in the Diffusing Alpha-emitters Radiation Therapy (DaRT) technique's pre-planning and treatment stages. This device would help to determine the proper number of sources for tumour coverage, accounting for subcutaneous invasion and augmenting DaRT safety. The procedure will be carried out in a first phase on a phantom and then applied to a clinical case. A typical DaRT procedure workflow comprises steps like tumour measurements and delineation, source number assessment, and therapy administration. As a first step, an adhesive fiberglass mesh (spaced by 2 mm) tape was applied on the skin of the patient and employed as frame of reference. A physician contoured the lesion and marked the entrance points for the needles with a radio opaque ink marker. According to the radio opaque marks and metabolic uptake the clinical target volume was defined, and with a commercial brachytherapy treatment planning system (TPS) it was possible to simulate and adjust the spatial seeds distribution. After the implant procedure a CT was again performed to check the agreement between simulations and seeds positions. With the procedure described above it was possible to simulate a DaRT procedure on a phantom in order to train physicians and subsequently apply the novel approach on patients, outlining the major issues involved in the technique. The present work innovates and supports DaRT technique for the treatment of cutaneous cancers, improving its efficacy and safety.

5.
Sci Rep ; 12(1): 14, 2022 01 07.
Article in English | MEDLINE | ID: mdl-34996956

ABSTRACT

The majority of local recurrences, after conservative surgery of breast cancer, occurs in the same anatomical area where the tumour was originally located. For the treatment of ductal carcinoma in situ (DCIS), a new medical device, named BAT-90, (BetaGlue Technologies SpA) has been proposed. BAT-90 is based on the administration of 90Y ß-emitting microspheres, embedded in a bio-compatible matrix. In this work, the Geant4 simulation toolkit is used to simulate BAT-90 as a homogenous cylindrical 90Y layer placed in the middle of a bulk material. The activity needed to deliver a 20 Gy isodose at a given distance z from the BAT-90 layer is calculated for different device thicknesses, tumour bed sizes and for water and adipose bulk materials. A radiobiological analysis has been performed using both the Poisson and logistic Tumour Control Probability (TCP) models. A range of radiobiological parameters (α and ß), target sizes, and densities of tumour cells were considered. Increasing α values, TCP increases too, while, for a fixed α value, TCP decreases as a function of clonogenic cell density. The models predict very solid results in case of limited tumour burden while the activity/dose ratio could be further optimized in case of larger tumour beds.


Subject(s)
Breast Neoplasms/radiotherapy , Carcinoma, Ductal, Breast/radiotherapy , Carcinoma, Intraductal, Noninfiltrating/radiotherapy , Radiotherapy/methods , Computer Simulation , Female , Humans , Logistic Models , Radiotherapy/instrumentation , Radiotherapy Dosage , Tumor Burden
6.
Sci Data ; 8(1): 209, 2021 08 05.
Article in English | MEDLINE | ID: mdl-34354085

ABSTRACT

Testicular cancer is a rare tumor with a worldwide incidence that has increased over the last few decades. The majority of these tumors are testicular non-germ (TNGCTs) and germ cell tumors (TGCTs); the latter divided into two broad classes - seminomatous (SGCTs) and non-seminomatous germ cell tumors (NSGCTs). Although ultrasonography (US) maintains a primary role in the diagnostic workup of scrotal pathology, magnetic resonance imaging (MRI) has emerged as the imaging modality recommended for challenging cases, providing additional information to clarify inconclusive/equivocal US. In this work we describe and publicly share a collection of 44 images of annotated T2-weighted MRI lesions from 42 patients. Given that testicular cancer is a rare tumor, we are confident that this collection can be used to validate statistical models and to further investigate TNGCT and TGCT peculiarities using medical imaging features.


Subject(s)
Magnetic Resonance Imaging , Neoplasms, Germ Cell and Embryonal/diagnostic imaging , Testicular Neoplasms/diagnostic imaging , Adult , Humans , Male , Middle Aged , Seminoma/diagnostic imaging , Testis/diagnostic imaging , Testis/pathology , Young Adult
7.
Front Oncol ; 11: 601053, 2021.
Article in English | MEDLINE | ID: mdl-34249671

ABSTRACT

PURPOSE: The objective of this study was to evaluate a set of radiomics-based advanced textural features extracted from 18F-FLT-PET/CT images to predict tumor response to neoadjuvant chemotherapy (NCT) in patients with locally advanced breast cancer (BC). MATERIALS AND METHODS: Patients with operable (T2-T3, N0-N2, M0) or locally advanced (T4, N0-N2, M0) BC were enrolled. All patients underwent chemotherapy (six cycles every 3 weeks). Surgery was performed within 4 weeks of the end of NCT. The MD Anderson Residual Cancer Burden calculator was used to evaluate the pathological response. 18F-FLT-PET/CT was performed 2 weeks before the start of NCT and approximately 3 weeks after the first cycle. The evaluation of PET response was based on EORTC criteria. Standard uptake value (SUV) statistics (SUVmax, SUVpeak, SUVmean), together with 148 textural features, were extracted from each lesion. Indices that are robust against contour variability (ICC test) were used as independent variables to logistically model tumor response. LASSO analysis was used for variable selection. RESULTS: Twenty patients were included in the study. Lesions from 15 patients were evaluable and analyzed: 9 with pathological complete response (pCR) and 6 with pathological partial response (pPR). Concordance between PET response and histological examination was found in 13/15 patients. LASSO logistic modelling identified a combination of SUVmax and the textural feature index IVH_VolumeIntFract_90 as the most useful to classify PET response, and a combination of PET response, ID range, and ID_Coefficient of Variation as the most useful to classify pathological response. CONCLUSIONS: Our study suggests the potential usefulness of FLT-PET for early monitoring of response to NCT. A model based on PET radiomic characteristics could have good discriminatory capacity of early response before the end of treatment.

8.
Sci Rep ; 11(1): 3456, 2021 02 10.
Article in English | MEDLINE | ID: mdl-33568713

ABSTRACT

How to differentiate with MRI-based techniques testicular germ (TGCTs) and testicular non-germ cell tumors (TNGCTs) is still under debate and Radiomics may be the turning key. Our purpose is to investigate the performance of MRI-based Radiomics signatures for the preoperative prediction of testicular neoplasm histology. The aim is twofold: (i), differentiating TGCTs and TNGCTs status and (ii) differentiating seminomas (SGCTs) from non-seminomatous (NSGCTs). Forty-two patients with pathology-proven testicular neoplasms and referred for pre-treatment MRI, were retrospectively enrolled. Thirty-two out of 44 lesions were TGCTs. Twelve out of 44 were TNGCTs or other histologies. Two radiologists segmented the volume of interest on T2-weighted images. Approximately 500 imaging features were extracted. Least Absolute Shrinkage and Selection Operator (LASSO) was applied as method for variable selection. A linear model and a linear support vector machine (SVM) were trained with selected features to assess discrimination scores for the two endpoints. LASSO identified 3 features that were employed to build fivefold validated linear discriminant and linear SVM classifiers for the TGCT-TNGCT endpoint giving an overall accuracy of 89%. Four features were employed to build another SVM for the SGCT-SNGCT endpoint with an overall accuracy of 86%. The data obtained proved that T2-weighted-based Radiomics is a promising tool in the diagnostic workup of testicular neoplasms by discriminating germ cell from non-gem cell tumors, and seminomas from non-seminomas.


Subject(s)
Neoplasms, Germ Cell and Embryonal/diagnostic imaging , Seminoma/diagnostic imaging , Testicular Neoplasms/diagnostic imaging , Adult , Biomarkers , Diagnosis, Differential , Humans , Magnetic Resonance Imaging , Male , Neoplasms, Germ Cell and Embryonal/pathology , Retrospective Studies , Seminoma/pathology , Support Vector Machine , Testicular Neoplasms/pathology
9.
Brachytherapy ; 20(1): 272-278, 2021.
Article in English | MEDLINE | ID: mdl-33041230

ABSTRACT

PURPOSE: The aim of this work was to analyze the exposure rates measured in the proximity of patients who underwent prostate low-dose-rate brachytherapy with I-125 implant. Effective doses to relatives and to population were computed to estimate the time to reach radioprotection dose constraints. METHODS AND MATERIALS: Measurements were obtained from 180 patients, whereas the body mass index was calculated and reported for 77 patients. The day after the implant, K˙ measurements were conducted at various skin distances and positions and converted to effective doses. A theoretical model was developed to estimate effective doses from total implanted activity. The latter was approximated with a 10-mL vial inside the patient. RESULTS: The K˙ measurements showed a low correlation with the total implanted activity, albeit an increasing trend of K˙ was observed on increasing the activity. A stronger correlation was found between body mass index and K˙ measurements. The effective dose to population is in general lower than dose constraints as well as the effective doses to relatives, with the exception of children and pregnant women, who command special precautions. We report differences between the experimental model- and theoretical model-based dose evaluation together with their comparison with previous studies found in literature. CONCLUSIONS: Based on the K˙ measurements and the results of the present analysis, it is possible to provide the patient with radiation safety instructions specifically tailored to his relatives' habits and working environment.


Subject(s)
Brachytherapy , Prostatic Neoplasms , Radiation Protection , Brachytherapy/methods , Child , Humans , Iodine Radioisotopes/therapeutic use , Male , Pregnancy , Prostatic Neoplasms/radiotherapy , Radiotherapy Dosage
10.
J Contemp Brachytherapy ; 11(5): 449-457, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31749854

ABSTRACT

PURPOSE: Alpha particle treatments could enhance the probability of an immune response, which can lead to abscopal effects (AE). We report a case of a patient affected by multiple cutaneous squamous cell carcinoma (cSCC). After the treatment with diffusing alpha emitters radiation therapy (DaRT) of one lesion, an AE was observed on at least two distant ones. MATERIAL AND METHODS: We investigated a case of a 65-year-old female patient with multiple synchronous lesions of the skin of lower limbs confirmed by a biopsy. Patient was enrolled in a clinical trial N.CTP-SCC-00 (NCT03015883), with the objective to assess effectiveness of DaRT technique. DaRT is based on the insertion of locally 224Ra-loaded seeds in a clinical target volume (CTV). Treatment plan with positron emission tomography/computed tomography (PET/CT) was used to entirely cover the CTV. Follow-up and biopsy evaluations were employed to outline the patient outcome. RESULTS: We performed seeds implantation according to the Paris system. At 28th day, an evident lesion shrinkage with a persistent minimal area of hyperkeratosis was noted. 76 days after implantation, a complete remission of the treated lesion was observed and an evident reduction of the area with two more distant lesion, which could be associated to an immune-mediated response. One year after the treatment, a complete remission of treated lesion was observed as well as spontaneous regression of untreated distant ones. CONCLUSIONS: In this study, we reported evidences of an AE in cSCC stimulated by radiation and possibly mediated by immune system. In the next DaRT treatments, our intent is to monitor T-lymphocytes variations in peripheral blood in order to demonstrate indirect activation of the immune system mediated by radiation also in patients with solitary lesions, in which, by definition, an AE cannot be observed.

11.
PLoS One ; 14(7): e0218814, 2019.
Article in English | MEDLINE | ID: mdl-31365526

ABSTRACT

The purpose of this study was to apply texture analysis (TA) to evaluate the uniformity of SPECT images reconstructed with the 3D Ordered Subsets Expectation Maximization (3D-OSEM) algorithm. For this purpose, a cylindrical homogeneous phantom filled with 177Lu was used and a total of 24 spherical volumes of interest (VOIs) were considered inside the phantom. The location of the VOIs was chosen in order to define two different configurations, i.e. gravity and radial configuration. The former configuration was used to investigate the uniformity of distribution of 177Lu inside the phantom, while the latter configuration was used to investigate the lack of uniformity from center towards edge of the images. For each VOI, the trend of different texture features considered as a function of 3D-OSEM updates was investigated in order to evaluate the influence of reconstruction parameters. TA was performed using CGITA software. The equality of the average texture feature trends in both spatial configurations was assumed as the null hypothesis and was tested by functional analysis of variance (fANOVA). With regard to the gravity configuration, no texture feature rejected the null hypothesis when the number of subsets increased. For the radial configuration, the statistical analysis revealed that, depending on the 3D-OSEM parameters used, a few texture features were capable of detecting the non-uniformity of 177Lu distribution inside the phantom moving from the center of the image towards its edge. Finally, cross-correlation coefficients were calculated to better identify the features that could play an important role in assessing quality assurance procedures performed on SPECT systems.


Subject(s)
Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Phantoms, Imaging , Tomography, Emission-Computed, Single-Photon/methods , Algorithms , Humans , Lutetium/chemistry , Lutetium/therapeutic use , Radioisotopes/chemistry , Radioisotopes/therapeutic use , Software
12.
Acta Oncol ; 56(11): 1544-1553, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28885084

ABSTRACT

BACKGROUND: Radiomic analyses of CT images provide prognostic information that can potentially be used for personalized treatment. However, heterogeneity of acquisition- and reconstruction protocols influences robustness of radiomic analyses. The aim of this study was to investigate the influence of different CT-scanners, slice thicknesses, exposures and gray-level discretization on radiomic feature values and their stability. MATERIAL AND METHODS: A texture phantom with ten different inserts was scanned on nine different CT-scanners with varying tube currents. Scans were reconstructed with 1.5 mm or 3 mm slice thickness. Image pre-processing comprised gray-level discretization in ten different bin widths ranging from 5 to 50 HU and different resampling methods (i.e., linear, cubic and nearest neighbor interpolation to 1 × 1 × 3 mm3 voxels) were investigated. Subsequently, 114 textural radiomic features were extracted from a 2.1 cm3 sphere in the center of each insert. The influence of slice thickness, exposure and bin width on feature values was investigated. Feature stability was assessed by calculating the concordance correlation coefficient (CCC) in a test-retest setting and for different combinations of scanners, tube currents and slice thicknesses. RESULTS: Bin width influenced feature values, but this only had a marginal effect on the total number of stable features (CCC > 0.85) when comparing different scanners, slice thicknesses or exposures. Most radiomic features were affected by slice thickness, but this effect could be reduced by resampling the CT-images before feature extraction. Statistics feature 'energy' was the most dependent on slice thickness. No clear correlation between feature values and exposures was observed. CONCLUSIONS: CT-scanner, slice thickness and bin width affected radiomic feature values, whereas no effect of exposure was observed. Optimization of gray-level discretization to potentially improve prognostic value can be performed without compromising feature stability. Resampling images prior to feature extraction decreases the variability of radiomic features.


Subject(s)
Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Tomography Scanners, X-Ray Computed , Tomography, X-Ray Computed/methods , Carcinoma, Non-Small-Cell Lung/radiotherapy , Humans , Lung Neoplasms/radiotherapy
13.
Adv Physiol Educ ; 40(3): 410-7, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27503902

ABSTRACT

This laboratory activity is designed to teach students how to measure forearm muscle blood flow (FBF) to describe the mechanisms of peripheral blood flow thermal regulation in healthy subjects. The cold pressor test (CPT) is the clinical procedure used in the experiment to induce arterial vasoconstriction. Strain-gauge plethysmography is applied on the patient's forearm to noninvasive monitor vasoconstriction effects on local blood perfusion and physiological parameters such as blood pressure (BP) and heart rate (HR). Patients with an altered peripheral vascular resistance (e.g., in hypertension) have different responses to the CPT from healthy subjects. To date, experimental evidence remains unexplained, as we do not know if the BP and HR increase is caused by a decrease in flow rate or an increase in peripheral vascular resistance during the test. To clarify this situation, we have to quantify the parameter we assume is being conditioned by the regulatory physiological intervention, i.e., peripheral vascular resistance. Peripheral vascular resistance quantification can be calculated as the ratio between muscle flow and mean arterial pressure. Students will learn how to apply the instrumental procedure to collect and analyze data before, during, and after the CPT and to describe the physiological responses of the peripheral vascular system to external stressors. They will also learn how to distinguish healthy from pathological responses on the basis of how sympathetic nervous system reactions influence the biomechanics of peripheral vessels.


Subject(s)
Blood Pressure Determination/methods , Blood Pressure/physiology , Cold Temperature , Physiology/education , Students, Medical , Blood Flow Velocity , Blood Pressure Determination/instrumentation , Forearm/blood supply , Humans , Plethysmography/methods , Vascular Resistance/physiology
14.
IEEE Trans Biomed Eng ; 62(5): 1355-62, 2015 May.
Article in English | MEDLINE | ID: mdl-25576560

ABSTRACT

OBJECTIVE: Characteristics of vortices within intracranial aneurysmal flow patterns have been associated with increased risk of rupture. The classifications of these vortex characteristics are commonly based upon qualitative scores, and are, therefore, subjective to user interpretation. We present a quantitative method for automatic time-resolved characterization of 3-D flow patterns and vortex detection within aneurysms. METHODS: Our approach is based upon the combination of kernel deconvolution and Jacobian analysis of the velocity field. The deconvolution approach is accurate in detecting vortex centers but cannot discriminate between vortices and high-shear regions. Therefore, this approach is combined with analysis of the Jacobian of the velocity field. Scale-space theory is used to evaluate aneurysmal flow velocity fields at various scales. RESULTS: The proposed algorithm is applied to computational fluid dynamics and time-resolved 3-D phase-contrast magnetic resonance imaging of aneurysmal flow. CONCLUSION: Results show that the proposed algorithm efficiently detects, visualizes, and quantifies vortices in intracranial aneurysmal velocity patterns at multiple scales and follows the temporal evolution of these patterns. SIGNIFICANCE: Quantitative analysis performed with this method has the potential to reduce interobserver variability in aneurysm classification.


Subject(s)
Blood Flow Velocity/physiology , Imaging, Three-Dimensional/methods , Intracranial Aneurysm/pathology , Intracranial Aneurysm/physiopathology , Magnetic Resonance Angiography/methods , Models, Cardiovascular , Algorithms , Humans , Phantoms, Imaging
15.
Phys Med ; 29(1): 33-8, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22138139

ABSTRACT

The aim of this paper is to clarify some physical-mechanical aspects involved in the carbon dioxide angiography procedure (CO2 angiography), with a particular attention to a possible damage of the vascular wall. CO2 angiography is widely used on patients with iodine intolerance. The injection of a gaseous element, in most cases manually performed, requires a long training period. Automatic systems allow better control of the injection and the study of the mechanical behaviour of the gas. CO2 injections have been studied by using manual and automatic systems. Pressures, flows and jet shapes have been monitored by using a cardiovascular mock. Photographic images of liquid and gaseous jet have been recorded in different conditions, and the vascular pressure rises during injection have been monitored. The shape of the liquid jet during the catheter washing phase is straight in the catheter direction and there is no jet during gas injection. Gas bubbles are suddenly formed at the catheter's hole and move upwards: buoyancy is the only governing phenomenon and no bubbles fragmentation is detected. The pressure rise in the vessel depends on the injection pressure and volume and in some cases of manual injection it may double the basal vascular pressure values. CO2 angiography is a powerful and safe procedure which diffusion will certainly increase, although some aspects related to gas injection and chamber filling are not jet well known. The use of an automatic system permits better results, shorter training period and limitation of vascular wall damage risk.


Subject(s)
Angiography/methods , Carbon Dioxide , Mechanical Phenomena , Angiography/instrumentation , Aortography , Humans , Injections , Pressure , Quality Control , Risk
SELECTION OF CITATIONS
SEARCH DETAIL
...