1.
Comput Biol Med ; 171: 108111, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38382384

ABSTRACT

Estimating fetal brain age based on sulci by magnetic resonance imaging (MRI) is clinically crucial in determining the normal development of fetal brains. Deep learning provides a possible way for fetal brain age estimation using MRI. Previous studies have mainly emphasized optimizing individual-wise correlation criteria, such as mean square error. However, they ignored the very important global and peer-wise criterion, which are essential for learning the structured relationships among regression samples. Moreover, the imbalanced label distribution introduces an adverse bias, which impairs the reliability and interpretation of correlation estimation and the model's fairness and generalizability. In this work, we propose a novel joint correlation learning with ranking similarity regularization (JoCoRank) algorithm for deep imbalanced regression of fetal brain age. Joint correlation learning concurrently captures individual, global, and peer-level valuable relationship information, and the customized optimization scheme for each criterion exhibits strong robustness against outliers and imbalanced regression. Ranking similarity regularization is designed to calibrate the biased feature representations by aligning the sorted list of neighbors in the label space with those in the feature space. A total of 1327 MRI images from 157 healthy fetuses between 22 and 34 weeks were collected at Wuhan Children's Hospital and utilized to evaluate the performance of JoCoRank in fetal brain age estimation. JoCoRank achieved promising results with an average mean absolute error of 0.693±0.064 weeks and R2 coefficient of 0.930±0.019. Our fetal brain age estimation algorithm would be useful for identifying abnormalities in fetal brain development and undertaking early intervention in clinical practice.


Subject(s)
Fetal Development , Magnetic Resonance Imaging , Child , Humans , Reproducibility of Results , Magnetic Resonance Imaging/methods , Gestational Age , Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods
2.
Comput Methods Programs Biomed ; 244: 107957, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38061113

ABSTRACT

BACKGROUND AND OBJECTIVES: Total Plaque Area (TPA) measurement is critical for early diagnosis and intervention of carotid atherosclerosis in individuals with high risk for stroke. The delineation of the carotid plaques is necessary for TPA measurement, and deep learning methods can automatically segment the plaque and measure TPA from carotid ultrasound images. A large number of labeled images is essential for training a good deep learning model, but it is very difficult to collect such large labeled datasets for carotid image segmentation in clinical practice. Self-supervised learning can provide a possible solution to improve the deep-learning models on small labeled training datasets by designing a pretext task to pre-train the models without using the segmentation masks. However, the existing self-supervised learning methods do not consider the feature presentations of object contours. METHODS: In this paper, we propose an image registration-based self-supervised learning method and a stacked U-Net (SSL-SU-Net) for carotid plaque ultrasound image segmentation, which can better exploit the semantic features of carotid plaque contours in self-supervised task training. RESULTS: Our network was trained on different numbers of labeled images (n = 10, 33, 50 and 100 subjects) and tested on 44 subjects from the SPARC dataset (n = 144, London, Canada). The network trained on the entire SPARC dataset was then directly applied to an independent dataset collected in Zhongnan hospital (n = 497, Wuhan, China). For the 44 subjects tested on the SPARC dataset, our method yielded a DSC of 80.25-89.18% and the produced TPA measurements, which were strongly correlated with manual segmentation (r = 0.965-0.995, ρ< 0.0001). For the Zhongnan dataset, the DSC was 90.3% and algorithm TPAs were strongly correlated with manual TPAs (r = 0.985, ρ< 0.0001). CONCLUSIONS: The results demonstrate that our proposed method yielded excellent performance and good generalization ability when trained on a small labeled dataset, facilitating the use of deep learning in carotid ultrasound image analysis and clinical practice. The code of our algorithm is available https://github.com/a610lab/Registration-SSL.


Subject(s)
Carotid Artery Diseases , Plaque, Atherosclerotic , Humans , Ultrasonography/methods , Plaque, Atherosclerotic/diagnostic imaging , Carotid Artery Diseases/diagnostic imaging , Carotid Arteries/diagnostic imaging , Ultrasonography, Carotid Arteries , Image Processing, Computer-Assisted/methods
3.
Med Phys ; 51(2): 1092-1104, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37493097

ABSTRACT

BACKGROUND: Synovitis is one of the defining characteristics of osteoarthritis (OA) in the carpometacarpal (CMC1) joint of the thumb. Quantitative characterization of synovial volume is important for furthering our understanding of CMC1 OA disease progression, treatment response, and monitoring strategies. In previous studies, three-dimensional ultrasound (3-D US) has demonstrated the feasibility of being a point-of-care system for monitoring knee OA. However, 3-D US has not been tested on the smaller joints of the hand, which presents unique physiological and imaging challenges. PURPOSE: To develop and validate a novel application of 3-D US to monitor soft-tissue characteristics of OA in a CMC1 OA patient population compared to the current gold standard, magnetic resonance imaging (MRI). METHODS: A motorized submerged transducer moving assembly was designed for this device specifically for imaging the joints of the hands and wrist. The device used a linear 3-D scanning approach, where a 14L5 2-D transducer was translated over the region of interest. Two imaging phantoms were used to test the linear and volumetric measurement accuracy of the 3-D US device. To evaluate the accuracy of the reconstructed 3-D US geometry, a multilayer monofilament string-grid phantom (10 mm square grid) was scanned. To validate the volumetric measurement capabilities of the system, a simulated synovial tissue phantom with an embedded synovial effusion was fabricated and imaged. Ten CMC1 OA patients were imaged by our 3-D US and a 3.0 T MRI system to compare synovial volumes. The synovial volumes were manually segmented by two raters on the 2D slices of the 3D US reconstruction and MR images, to assess the accuracy and precision of the device for determining synovial tissue volumes. The Standard Error of Measurement and Minimal Detectable Change was used to assess the precision and sensitivity of the volume measurements. Paired sample t-tests were used to assess statistical significance. Additionally, rater reliability was assessed using Intra-Class Correlation (ICC) coefficients. RESULTS: The largest percent difference observed between the known physical volume of synovial extrusion in the phantom and the volume measured by our 3D US was 1.1% (p-value = 0.03). The mean volume difference between the 3-D US and the gold standard MRI was 1.78% (p-value = 0.48). The 3-D US synovial tissue volume measurements had a Standard Error Measurement (SEm ) of 11.21 mm3 and a Minimal Detectible Change (MDC) of 31.06 mm3 , while the MRI synovial tissue volume measurements had an SEM of 16.82 mm3 and an MDC of 46.63 mm3 . Excellent inter- and intra-rater reliability (ICCs = 0.94-0.99) observed across all imaging modalities and raters. CONCLUSION: Our results indicate the feasibility of applying 3-D US technology to provide accurate and precise CMC1 synovial tissue volume measurements, similar to MRI volume measurements. Lower MDC and SEm values for 3-D US volume measurements indicate that it is a precise measurement tool to assess synovial volume and that it is sensitive to variation between volume segmentations. The application of this imaging technique to monitor OA pathogenesis and treatment response over time at the patient's bedside should be thoroughly investigated in future studies.


Subject(s)
Osteoarthritis, Knee , Synovitis , Humans , Feasibility Studies , Reproducibility of Results , Synovitis/diagnostic imaging , Synovitis/etiology , Synovitis/pathology , Synovial Membrane/pathology , Osteoarthritis, Knee/complications , Osteoarthritis, Knee/pathology , Magnetic Resonance Imaging/methods
4.
Med Phys ; 51(4): 2665-2677, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37888789

ABSTRACT

BACKGROUND: Accurate segmentation of the clinical target volume (CTV) corresponding to the prostate with or without proximal seminal vesicles is required on transrectal ultrasound (TRUS) images during prostate brachytherapy procedures. Implanted needles cause artifacts that may make this task difficult and time-consuming. Thus, previous studies have focused on the simpler problem of segmentation in the absence of needles at the cost of reduced clinical utility. PURPOSE: To use a convolutional neural network (CNN) algorithm for segmentation of the prostatic CTV in TRUS images post-needle insertion obtained from prostate brachytherapy procedures to better meet the demands of the clinical procedure. METHODS: A dataset consisting of 144 3-dimensional (3D) TRUS images with implanted metal brachytherapy needles and associated manual CTV segmentations was used for training a 2-dimensional (2D) U-Net CNN using a Dice Similarity Coefficient (DSC) loss function. These were split by patient, with 119 used for training and 25 reserved for testing. The 3D TRUS training images were resliced at radial (around the axis normal to the coronal plane) and oblique angles through the center of the 3D image, as well as axial, coronal, and sagittal planes to obtain 3689 2D TRUS images and masks for training. The network generated boundary predictions on 300 2D TRUS images obtained from reslicing each of the 25 3D TRUS images used for testing into 12 radial slices (15° apart), which were then reconstructed into 3D surfaces. Performance metrics included DSC, recall, precision, unsigned and signed volume percentage differences (VPD/sVPD), mean surface distance (MSD), and Hausdorff distance (HD). In addition, we studied whether providing algorithm-predicted boundaries to the physicians and allowing modifications increased the agreement between physicians. This was performed by providing a subset of 3D TRUS images of five patients to five physicians who segmented the CTV using clinical software and repeated this at least 1 week apart. The five physicians were given the algorithm boundary predictions and allowed to modify them, and the resulting inter- and intra-physician variability was evaluated. RESULTS: Median DSC, recall, precision, VPD, sVPD, MSD, and HD of the 3D-reconstructed algorithm segmentations were 87.2 [84.1, 88.8]%, 89.0 [86.3, 92.4]%, 86.6 [78.5, 90.8]%, 10.3 [4.5, 18.4]%, 2.0 [-4.5, 18.4]%, 1.6 [1.2, 2.0] mm, and 6.0 [5.3, 8.0] mm, respectively. Segmentation time for a set of 12 2D radial images was 2.46 [2.44, 2.48] s. With and without U-Net starting points, the intra-physician median DSCs were 97.0 [96.3, 97.8]%, and 94.4 [92.5, 95.4]% (p < 0.0001), respectively, while the inter-physician median DSCs were 94.8 [93.3, 96.8]% and 90.2 [88.7, 92.1]%, respectively (p < 0.0001). The median segmentation time for physicians, with and without U-Net-generated CTV boundaries, were 257.5 [211.8, 300.0] s and 288.0 [232.0, 333.5] s, respectively (p = 0.1034). CONCLUSIONS: Our algorithm performed at a level similar to physicians in a fraction of the time. The use of algorithm-generated boundaries as a starting point and allowing modifications reduced physician variability, although it did not significantly reduce the time compared to manual segmentations.


Subject(s)
Brachytherapy , Deep Learning , Prostatic Neoplasms , Male , Humans , Prostate/diagnostic imaging , Brachytherapy/methods , Ultrasonography , Algorithms , Image Processing, Computer-Assisted/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy
5.
Phys Med Biol ; 68(23)2023 Nov 28.
Article in English | MEDLINE | ID: mdl-37918343

ABSTRACT

Objective.Ultrasound is the most commonly used examination for the detection and identification of thyroid nodules. Since manual detection is time-consuming and subjective, attempts to introduce machine learning into this process are ongoing. However, the performance of these methods is limited by the low signal-to-noise ratio and tissue contrast of ultrasound images. To address these challenges, we extend thyroid nodule detection from image-based to video-based using the temporal context information in ultrasound videos.Approach.We propose a video-based deep learning model with adjacent frame perception (AFP) for accurate and real-time thyroid nodule detection. Compared to image-based methods, AFP can aggregate semantically similar contextual features in the video. Furthermore, considering the cost of medical image annotation for video-based models, a patch scale self-supervised model (PASS) is proposed. PASS is trained on unlabeled datasets to improve the performance of the AFP model without additional labelling costs.Main results.The PASS model is trained by 92 videos containing 23 773 frames, of which 60 annotated videos containing 16 694 frames were used to train and evaluate the AFP model. The evaluation is performed from the video, frame, nodule, and localization perspectives. In the evaluation of the localization perspective, we used the average precision metric with the intersection-over-union threshold set to 50% (AP@50), which is the area under the smoothed Precision-Recall curve. Our proposed AFP improved AP@50 from 0.256 to 0.390, while the PASS-enhanced AFP further improved the AP@50 to 0.425. AFP and PASS also improve the performance in the valuations of other perspectives based on the localization results.Significance.Our video-based model can mitigate the effects of low signal-to-noise ratio and tissue contrast in ultrasound images and enable the accurate detection of thyroid nodules in real-time. The evaluation from multiple perspectives of the ablation experiments demonstrates the effectiveness of our proposed AFP and PASS models.


Subject(s)
Thyroid Nodule , Humans , Thyroid Nodule/diagnostic imaging , alpha-Fetoproteins , Ultrasonography , Machine Learning , Signal-To-Noise Ratio
6.
Brachytherapy ; 22(6): 790-799, 2023.
Article in English | MEDLINE | ID: mdl-37722991

ABSTRACT

PURPOSE: To demonstrate novel clinical implementation of a 3D transvaginal ultrasound (3DTVUS) system for intraoperative needle insertion guidance in perineal template interstitial gynecologic high-dose-rate brachytherapy and assess its impact on implant quality. METHODS AND MATERIALS: Interstitial implants began with preimplant 3DTVUS to visualize the tumor and anatomy, with intermittent 3DTVUS to assess the implant and guide needle adjustment. Analysis includes visualization of the implant relative to anatomy, identification of cases where 3DTVUS is beneficial, dosimetry, and a survey distributed to 3DTVUS clinicians. RESULTS: Seven patients treated between November 2021 and October 2022 were included in this study. Twenty needles were inserted under 3DTVUS guidance. The tumor and vaginal wall were well-differentiated in four and all seven patients, respectively. Patients with tumours below the superior aspect of the vagina are suited for 3DTVUS. Four radiation oncologists responded to the survey. There was general agreement that 3DTVUS improves implant and anatomy visualization and is preferred over standard 2D ultrasound guidance techniques. CONCLUSIONS: Based on qualitative feedback from primary users and a small preliminary patient cohort, 3DTVUS imaging improves tumor and vaginal wall visualization during gynecologic perineal template interstitial needle implant and is a powerful tool for implant assessment in an intraoperative setting.


Subject(s)
Brachytherapy , Genital Neoplasms, Female , Humans , Female , Brachytherapy/methods , Genital Neoplasms, Female/diagnostic imaging , Genital Neoplasms, Female/radiotherapy , Genital Neoplasms, Female/surgery , Ultrasonography , Vagina/diagnostic imaging , Radiometry , Radiotherapy Dosage
7.
Sci Rep ; 13(1): 14390, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37658125

ABSTRACT

Breast cancer screening has substantially reduced mortality across screening populations. However, a clinical need persists for more accessible, cost-effective, and robust approaches for increased-risk and diverse patient populations, especially those with dense breasts where screening mammography is suboptimal. We developed and validated a cost-effective, portable, patient-dedicated three-dimensional (3D) automated breast ultrasound (ABUS) system for point-of-care breast cancer screening. The 3D ABUS system contains a wearable, rapid-prototype 3D-printed dam assembly, a compression assembly, and a computer-driven 3DUS scanner, adaptable to any commercially available US machine and transducer. Acquisition is operator-agnostic, involves a 40-second scan time, and provides multiplanar 3D visualization for whole-breast assessment. Geometric reconstruction accuracy was evaluated with a 3D grid phantom and tissue-mimicking breast phantoms, demonstrating linear measurement and volumetric reconstruction errors < 0.2 mm and < 3%, respectively. The system's capability was demonstrated in a healthy male volunteer and two healthy female volunteers, representing diverse patient geometries and breast sizes. The system enables comfortable ultrasonic coupling and tissue stabilization, with adjustable compression to improve image quality while alleviating discomfort. Moreover, the system effectively mitigates breathing and motion, since its assembly affixes directly onto the patient. While future studies are still required to evaluate the impact on current clinical practices and workflow, the 3D ABUS system shows potential for adoption as an alternative, cost-effective, dedicated point-of-care breast cancer screening approach for increased-risk populations and limited-resource settings.


Subject(s)
Breast Neoplasms , Early Detection of Cancer , Humans , Female , Male , Breast Neoplasms/diagnostic imaging , Cost-Benefit Analysis , Point-of-Care Systems , Mammography
8.
Int J Comput Assist Radiol Surg ; 18(7): 1159-1166, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37162735

ABSTRACT

PURPOSE: US-guided percutaneous focal liver tumor ablations have been considered promising curative treatment techniques. To address cases with invisible or poorly visible tumors, registration of 3D US with CT or MRI is a critical step. By taking advantage of deep learning techniques to efficiently detect representative features in both modalities, we aim to develop a 3D US-CT/MRI registration approach for liver tumor ablations. METHODS: Facilitated by our nnUNet-based 3D US vessel segmentation approach, we propose a coarse-to-fine 3D US-CT/MRI image registration pipeline based on the liver vessel surface and centerlines. Then, phantom, healthy volunteer and patient studies are performed to demonstrate the effectiveness of our proposed registration approach. RESULTS: Our nnUNet-based vessel segmentation model achieved a Dice score of 0.69. In healthy volunteer study, 11 out of 12 3D US-MRI image pairs were successfully registered with an overall centerline distance of 4.03±2.68 mm. Two patient cases achieved target registration errors (TRE) of 4.16 mm and 5.22 mm. CONCLUSION: We proposed a coarse-to-fine 3D US-CT/MRI registration pipeline based on nnUNet vessel segmentation models. Experiments based on healthy volunteers and patient trials demonstrated the effectiveness of our registration workflow. Our code and example data are publicly available in this r epository.


Subject(s)
Liver Neoplasms , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Liver Neoplasms/pathology , Imaging, Three-Dimensional/methods , Image Processing, Computer-Assisted/methods
9.
Osteoarthr Cartil Open ; 5(2): 100356, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37008822

ABSTRACT

Objective: Effusion-synovitis is related to pain and progression in knee osteoarthritis (OA), but current gold standard ultrasound (US) measures are limited to semi-quantitative grading of joint distension or 1-dimensional thickness measures. A novel quantitative 2-dimensional image analysis methodology is applied to US images of effusion-synovitis; reliability and concurrent validity was assessed in patients with knee OA. Methods: Cross sectional analysis of US images collected from 51 patients with symptomatic knee OA were processed in ImageJ and segmented in 3DSlicer to produce a binary mask of the supra-patellar synovitis region of interest (ROI). Area measures (mm2) of total synovitis, effusion and hypertrophy components were exported. Intra-rater reliability and test-retest reliability (1-14 days washout) were estimated with intra-class correlation coefficients (ICCs). Concurrent validity was measured by Spearman correlations between quantitative measures and gold standard OMERACT and caliper measurements of synovitis. Results: Intra-rater reliability for hypertrophy area was estimated at 0.98, 0.99 for effusion area, and 0.99 for total synovitis area. The test-retest reliability for total synovitis area was 0.63 (SEM 87.8 â€‹mm2), 0.59 for hypertrophy area (SEM 21.0 â€‹mm2), and 0.64 for effusion area (SEM 73.8 â€‹mm2). Correlation between total synovitis area and OMERACT grade was 0.84, 0.81 between total synovitis area and effusion-synovitis calipers, and 0.81 between total effusion area and effusion calipers. Conclusion: This new research tool for image analysis demonstrated excellent intra-rater reliability, good concurrent validity, and moderate test-retest reliability. Quantitative 2D US measures of effusion-synovitis and its individual components may enhance the study and management of knee OA.

10.
Math Biosci Eng ; 20(2): 1617-1636, 2023 01.
Article in English | MEDLINE | ID: mdl-36899501

ABSTRACT

Carotid total plaque area (TPA) is an important contributing measurement to the evaluation of stroke risk. Deep learning provides an efficient method for ultrasound carotid plaque segmentation and TPA quantification. However, high performance of deep learning requires datasets with many labeled images for training, which is very labor-intensive. Thus, we propose an image reconstruction-based self-supervised learning algorithm (IR-SSL) for carotid plaque segmentation when few labeled images are available. IR-SSL consists of pre-trained and downstream segmentation tasks. The pre-trained task learns region-wise representations with local consistency by reconstructing plaque images from randomly partitioned and disordered images. The pre-trained model is then transferred to the segmentation network as the initial parameters in the downstream task. IR-SSL was implemented with two networks, UNet++ and U-Net, and evaluated on two independent datasets of 510 carotid ultrasound images from 144 subjects at SPARC (London, Canada) and 638 images from 479 subjects at Zhongnan hospital (Wuhan, China). Compared to the baseline networks, IR-SSL improved the segmentation performance when trained on few labeled images (n = 10, 30, 50 and 100 subjects). For 44 SPARC subjects, IR-SSL yielded Dice-similarity-coefficients (DSC) of 80.14-88.84%, and algorithm TPAs were strongly correlated (r=0.962-0.993, p < 0.001) with manual results. The models trained on the SPARC images but applied to the Zhongnan dataset without retraining achieved DSCs of 80.61-88.18% and strong correlation with manual segmentation (r=0.852-0.978, p < 0.001). These results suggest that IR-SSL could improve deep learning when trained on small labeled datasets, making it useful for monitoring carotid plaque progression/regression in clinical use and trials.


Subject(s)
Carotid Arteries , Image Processing, Computer-Assisted , Humans , Carotid Arteries/diagnostic imaging , Image Processing, Computer-Assisted/methods , Ultrasonography , Algorithms , Supervised Machine Learning
11.
Med Phys ; 50(5): 2649-2661, 2023 May.
Article in English | MEDLINE | ID: mdl-36846880

ABSTRACT

PURPOSE: High-dose-rate (HDR) interstitial brachytherapy (BT) is a common treatment technique for localized intermediate to high-risk prostate cancer. Transrectal ultrasound (US) imaging is typically used for guiding needle insertion, including localization of the needle tip which is critical for treatment planning. However, image artifacts can limit needle tip visibility in standard brightness (B)-mode US, potentially leading to dose delivery that deviates from the planned dose. To improve intraoperative tip visualization in visually obstructed needles, we propose a power Doppler (PD) US method which utilizes a novel wireless mechanical oscillator, validated in phantom experiments and clinical HDR-BT cases as part of a feasibility clinical trial. METHODS: Our wireless oscillator contains a DC motor housed in a 3D printed case and is powered by rechargeable battery allowing the device to be operated by one person with no additional equipment required in the operating room. The oscillator end-piece features a cylindrical shape designed for BT applications to fit on top of the commonly used cylindrical needle mandrins. Phantom validation was completed using tissue-equivalent agar phantoms with the clinical US system and both plastic and metal needles. Our PD method was tested using a needle implant pattern matching a standard HDR-BT procedure as well as an implant pattern designed to maximize needle shadowing artifacts. Needle tip localization accuracy was assessed using the clinical method based on ideal reference needles as well as a comparison to computed tomography (CT) as a gold standard. Clinical validation was completed in five patients who underwent standard HDR-BT as part of a feasibility clinical trial. Needle tips positions were identified using B-mode US and PD US with perturbation from our wireless oscillator. RESULTS: Absolute mean ± standard deviation tip error for B-mode alone, PD alone, and B-mode combined with PD was respectively: 0.3 ± 0.3 mm, 0.6 ± 0.5 mm, and 0.4 ± 0.2 mm for the mock HDR-BT needle implant; 0.8 ± 1.7 mm, 0.4 ± 0.6 mm, and 0.3 ± 0.5 mm for the explicit shadowing implant with plastic needles; and 0.5 ± 0.2 mm, 0.5 ± 0.3 mm, and 0.6 ± 0.2 mm for the explicit shadowing implant with metal needles. The total mean absolute tip error for all five patients in the feasibility clinical trial was 0.9 ± 0.7 mm using B-mode US alone and 0.8 ± 0.5 mm when including PD US, with increased benefit observed for needles classified as visually obstructed. CONCLUSIONS: Our proposed PD needle tip localization method is easy to implement and requires no modifications or additions to the standard clinical equipment or workflow. We have demonstrated decreased tip localization error and variation for visually obstructed needles in both phantom and clinical cases, including providing the ability to visualize needles previously not visible using B-mode US alone. This method has the potential to improve needle visualization in challenging cases without burdening the clinical workflow, potentially improving treatment accuracy in HDR-BT and more broadly in any minimally invasive needle-based procedure.


Subject(s)
Brachytherapy , Prostatic Neoplasms , Male , Humans , Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/surgery , Ultrasonography , Needles , Ultrasonography, Doppler
12.
J Neurosurg Pediatr ; 31(4): 321-328, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36670532

ABSTRACT

OBJECTIVE: Some neonates born prematurely with intraventricular hemorrhage develop posthemorrhagic hydrocephalus and require lifelong treatment to divert the flow of CSF. Early prediction of the eventual need for a ventriculoperitoneal shunt (VPS) is difficult, and early discussions with families are based on statistics and the grade of hemorrhage. The authors hypothesize that change in ventricular volume during ventricular taps that is measured with repeated 3D ultrasound (3D US) imaging of the lateral ventricles could be used to assess the risk of the future requirement of a VPS. METHODS: A total of 92 neonates with intraventricular hemorrhage who were treated in the NICU were recruited between April 2012 and November 2019. Only patients who required ventricular taps (VTs) were included in this study, resulting in the analysis of 19 patients with a total of 61 VTs. Among them, 14 patients were treated with a VPS, and in 5 patients the hydrocephalus resolved spontaneously. Parameters studied were total ventricular volume measured with 3D US, ventricular volume change after VT, the ratio between volume reduction and tap amount, the difference between tap amount and volume reduction after tap, the average tap amount, the average number of days between taps, pre-tap head circumference, and reduction in head circumference after tap. RESULTS: Statistically significant differences were found in ventricular volume reduction after tap (p = 0.007), the ratio between volume reduction and tap amount (p = 0.03), the difference between tap amount and volume reduction after tap (p = 0.05), and the interval of days between taps (p = 0.0115). CONCLUSIONS: Measuring with 3D US before and after VT can be a useful tool for quantifying ventricular volume. The findings in this study showed that neonates who experience a large reduction of ventricular volume after VT are more likely to be treated with a shunt than are neonates who experience a small reduction.


Subject(s)
Hydrocephalus , Ventriculoperitoneal Shunt , Infant, Newborn , Humans , Ventriculoperitoneal Shunt/adverse effects , Hydrocephalus/diagnostic imaging , Hydrocephalus/etiology , Hydrocephalus/surgery , Cerebral Hemorrhage/complications , Cerebral Hemorrhage/diagnostic imaging , Ultrasonography , Drainage , Retrospective Studies
13.
Brachytherapy ; 22(2): 199-209, 2023.
Article in English | MEDLINE | ID: mdl-36641305

ABSTRACT

PURPOSE: The purpose of this study was to evaluate and clinically implement a deformable surface-based magnetic resonance imaging (MRI) to three-dimensional ultrasound (US) image registration algorithm for prostate brachytherapy (BT) with the aim to reduce operator dependence and facilitate dose escalation to an MRI-defined target. METHODS AND MATERIALS: Our surface-based deformable image registration (DIR) algorithm first translates and scales to align the US- and MR-defined prostate surfaces, followed by deformation of the MR-defined prostate surface to match the US-defined prostate surface. The algorithm performance was assessed in a phantom using three deformation levels, followed by validation in three retrospective high-dose-rate BT clinical cases. For comparison, manual rigid registration and cognitive fusion by physician were also employed. Registration accuracy was assessed using the Dice similarity coefficient (DSC) and target registration error (TRE) for embedded spherical landmarks. The algorithm was then implemented intraoperatively in a prospective clinical case. RESULTS: In the phantom, our DIR algorithm demonstrated a mean DSC and TRE of 0.74 ± 0.08 and 0.94 ± 0.49 mm, respectively, significantly improving the performance compared to manual rigid registration with 0.64 ± 0.16 and 1.88 ± 1.24 mm, respectively. Clinical results demonstrated reduced variability compared to the current standard of cognitive fusion by physicians. CONCLUSIONS: We successfully validated a DIR algorithm allowing for translation of MR-defined target and organ-at-risk contours into the intraoperative environment. Prospective clinical implementation demonstrated the intraoperative feasibility of our algorithm, facilitating targeted biopsies and dose escalation to the MR-defined lesion. This method provides the potential to standardize the registration procedure between physicians, reducing operator dependence.


Subject(s)
Brachytherapy , Prostate , Male , Humans , Prostate/diagnostic imaging , Prostate/pathology , Brachytherapy/methods , Retrospective Studies , Prospective Studies , Algorithms , Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted/methods
14.
Ultrasound Med Biol ; 49(4): 1031-1036, 2023 04.
Article in English | MEDLINE | ID: mdl-36642588

ABSTRACT

Vessel wall volume (VWV) is a 3-D ultrasound measurement for the assessment of therapy in patients with carotid atherosclerosis. Deep learning can be used to segment the media-adventitia boundary (MAB) and lumen-intima boundary (LIB) and to quantify VWV automatically; however, it typically requires large training data sets with expert manual segmentation, which are difficult to obtain. In this study, a UNet++ ensemble approach was developed for automated VWV measurement, trained on five small data sets (n = 30 participants) and tested on 100 participants with clinically diagnosed coronary artery disease enrolled in a multicenter CAIN trial. The Dice similarity coefficient (DSC), average symmetric surface distance (ASSD), Pearson correlation coefficient (r), Bland-Altman plots and coefficient of variation (CoV) were used to evaluate algorithm segmentation accuracy, agreement and reproducibility. The UNet++ ensemble yielded DSCs of 91.07%-91.56% and 87.53%-89.44% and ASSDs of 0.10-0.11 mm and 0.33-0.39 mm for the MAB and LIB, respectively; the algorithm VWV measurements were correlated (r = 0.763-0.795, p < 0.001) with manual segmentations, and the CoV for VWV was 8.89%. In addition, the UNet++ ensemble trained on 30 participants achieved a performance similar to that of U-Net and Voxel-FCN trained on 150 participants. These results suggest that our approach could provide accurate and reproducible carotid VWV measurements using relatively small training data sets, supporting deep learning applications for monitoring atherosclerosis progression in research and clinical trials.


Subject(s)
Carotid Arteries , Imaging, Three-Dimensional , Humans , Reproducibility of Results , Imaging, Three-Dimensional/methods , Carotid Arteries/diagnostic imaging , Ultrasonography/methods , Algorithms
15.
Med Phys ; 50(3): 1259-1273, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36583505

ABSTRACT

BACKGROUND: Multiparametric MRI (mpMRI) is an effective tool for detecting and staging prostate cancer (PCa), guiding interventional therapy, and monitoring PCa treatment outcomes. MRI-guided focal laser ablation (FLA) therapy is an alternative, minimally invasive treatment method to conventional therapies, which has been demonstrated to control low-grade, localized PCa while preserving patient quality of life. The therapeutic success of FLA depends on the accurate placement of needles for adequate delivery of ablative energy to the target lesion. We previously developed an MR-compatible mechatronic system for prostate FLA needle guidance and validated its performance in open-air and clinical 3T in-bore experiments using virtual targets. PURPOSE: To develop a robust MRI-to-mechatronic system registration method and evaluate its in-bore MR-guided needle delivery accuracy in tissue-mimicking prostate phantoms. METHODS: The improved registration multifiducial assembly houses thirty-six aqueous gadolinium-filled spheres distributed over a 7.3 × 7.3 × 5.2 cm volume. MRI-guided needle guidance accuracy was quantified in agar-based tissue-mimicking prostate phantoms on trajectories (N = 44) to virtual targets covering the mechatronic system's range of motion. 3T gradient-echo recalled (GRE) MRI images were acquired after needle insertions to each target, and the air-filled needle tracks were segmented. Needle guidance error was measured as the shortest Euclidean distance between the target point and the segmented needle trajectory, and angular error was measured as the angle between the targeted trajectory and the segmented needle trajectory. These measurements were made using both the previously designed four-sphere registration fiducial assembly on trajectories (N = 7) and compared with the improved multifiducial assembly using a Mann-Whitney U test. RESULTS: The median needle guidance error of the system using the improved registration fiducial assembly at a depth of 10 cm was 1.02 mm with an interquartile range (IQR) of 0.42-2.94 mm. The upper limit of the one-sided 95% prediction interval of needle guidance error was 4.13 mm. The median (IQR) angular error was 0.0097 rad (0.0057-0.015 rad) with a one-sided 95% prediction interval upper limit of 0.022 rad. The median (IQR) positioning error using the previous four-sphere registration fiducial assembly was 1.87 mm (1.77-2.14 mm). This was found to be significantly different (p = 0.0012) from the median (IQR) positioning error of 0.28 mm (0.14-0.95 mm) using the new registration fiducial assembly on the same trajectories. No significant difference was detected between the medians of the angular errors (p = 0.26). CONCLUSION: This is the first study presenting an improved registration method and validation in tissue-mimicking phantoms of our remotely actuated MR-compatible mechatronic system for delivery of prostate FLA needles. Accounting for the effects of needle deflection, the system was demonstrated to be capable of needle delivery with an error of 4.13 mm or less in 95% of cases under ideal conditions, which is a statistically significant improvement over the previous method. The system will next be validated in a clinical setting.


Subject(s)
Laser Therapy , Prostatic Neoplasms , Male , Humans , Prostate/pathology , Quality of Life , Magnetic Resonance Imaging/methods , Needles , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/surgery
16.
Ultrasound Med Biol ; 49(1): 278-288, 2023 01.
Article in English | MEDLINE | ID: mdl-36220709

ABSTRACT

Joint arthropathies often require continuous monitoring of the joint condition, typically performed using magnetic resonance (MR) or ultrasound (US) imaging. US imaging is often the preferred screening or diagnostic tool as it is fast and inexpensive. However, conventional 2-D US has limited capability to compare imaging results between examinations because of its operator dependence and challenges related to repeat imaging in the same location and orientation. Comparison between several imaging sessions is crucial to assess the interval progression of joint conditions. We propose a novel 3-D US scanner for ankle joint assessment that can partially overcome these issues by enabling 3-D imaging. Here, we (i) present the design of the 3-D US ankle scanner system, (ii) validate the geometric reconstruction accuracy of the system, (iii) provide preliminary images of healthy volunteer ankles and (iv) compare 3-D US imaging results with MR imaging. The 3-D ankle scanner consists of a tub filled with water, a linear US probe attached to the wall of the tub and a motorized unit that rotates the US probe 360° around the center of the tub. As the probe rotates, a 3-D US image is formed of the ankle of the patient positioned in the middle of the tub. US probe height, angle and distance from the tub center can be adjusted. The reconstruction accuracy of the system was validated in each of the coordinate directions at different probe angles using two test phantoms. A phantom consisting of numerous Ø200-µm nylon threads with known spacing and a metal rod with machined grooves was used for validation in the horizontal and vertical directions, respectively. The volumetric reconstruction accuracy validation was performed by imaging an agar phantom with two embedded spheres of known volumes and comparing the segmented sphere volume and surface area with the expected. Three-dimensional US and MR images of both ankles of five healthy volunteers were acquired. Distal tibia and proximal talus were segmented in both imaging modalities and the surfaces of these segmentations were compared using the 95% Hausdorff and mean surface distances. The observed mean linear measurement error in all the coordinate directions and over several probe angles was 2.98%. The mean measured volumetric measurement error was 3.45%. The volunteer study revealed useful features for joint assessment present in the 3-D ankle scanner images, such as joint spacing, distal tibia and proximal talus. The mean 95% Hausdorff and mean surface distances between segmentations in 3-D US and MR images were 5.68 ± 0.83 and 2.01 ± 0.30 mm, respectively. In this proof-of-concept study, the 3-D US ankle scanner enabled visualization of the ankle joint features that are useful for joint assessment.


Subject(s)
Ankle Joint , Imaging, Three-Dimensional , Humans , Ankle Joint/diagnostic imaging , Ultrasonography/methods , Phantoms, Imaging , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods
17.
Osteoarthr Cartil Open ; 4(3): 100290, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36474947

ABSTRACT

Objective: This study aimed to develop a deep learning-based approach to automatically segment the femoral articular cartilage (FAC) in 3D ultrasound (US) images of the knee to increase time efficiency and decrease rater variability. Design: Our method involved deep learning predictions on 2DUS slices sampled in the transverse plane to view the cartilage of the femoral trochlea, followed by reconstruction into a 3D surface. A 2D U-Net was modified and trained using a dataset of 200 2DUS images resliced from 20 3DUS images. Segmentation accuracy was evaluated using a holdout dataset of 50 2DUS images resliced from 5 3DUS images. Absolute and signed error metrics were computed and FAC segmentation performance was compared between rater 1 and 2 manual segmentations. Results: Our U-Net-based algorithm performed with mean 3D DSC, recall, precision, VPD, MSD, and HD of 73.1 â€‹± â€‹3.9%, 74.8 â€‹± â€‹6.1%, 72.0 â€‹± â€‹6.3%, 10.4 â€‹± â€‹6.0%, 0.3 â€‹± â€‹0.1 â€‹mm, and 1.6 â€‹± â€‹0.7 â€‹mm, respectively. Compared to the individual 2D predictions, our algorithm demonstrated a decrease in performance after 3D reconstruction, but these differences were not found to be statistically significant. The percent difference between the manually segmented volumes of the 2 raters was 3.4%, and rater 2 demonstrated the largest VPD with 14.2 â€‹± â€‹11.4 â€‹mm3 compared to 10.4 â€‹± â€‹6.0 â€‹mm3 for rater 1. Conclusion: This study investigated the use of a modified U-Net algorithm to automatically segment the FAC in 3DUS knee images of healthy volunteers, demonstrating that this segmentation method would increase the efficiency of anterior femoral cartilage volume estimation and expedite the post-acquisition processing for 3D US images of the knee.

18.
NPJ Digit Med ; 5(1): 151, 2022 Sep 27.
Article in English | MEDLINE | ID: mdl-36168038

ABSTRACT

With the increase of the ageing in the world's population, the ageing and degeneration studies of physiological characteristics in human skin, bones, and muscles become important topics. Research on the ageing of bones, especially the skull, are paid much attention in recent years. In this study, a novel deep learning method representing the ageing-related dynamic attention (ARDA) is proposed. The proposed method can quantitatively display the ageing salience of the bones and their change patterns with age on lateral cephalometric radiographs images (LCR) images containing the craniofacial and cervical spine. An age estimation-based deep learning model based on 14142 LCR images from 4 to 40 years old individuals is trained to extract ageing-related features, and based on these features the ageing salience maps are generated by the Grad-CAM method. All ageing salience maps with the same age are merged as an ARDA map corresponding to that age. Ageing salience maps show that ARDA is mainly concentrated in three regions in LCR images: the teeth, craniofacial, and cervical spine regions. Furthermore, the dynamic distribution of ARDA at different ages and instances in LCR images is quantitatively analyzed. The experimental results on 3014 cases show that ARDA can accurately reflect the development and degeneration patterns in LCR images.

19.
IEEE Trans Med Imaging ; 41(11): 3344-3356, 2022 11.
Article in English | MEDLINE | ID: mdl-35724283

ABSTRACT

Complete tumor coverage by the thermal ablation zone and with a safety margin (5 or 10 mm) is required to achieve the entire tumor eradication in liver tumor ablation procedures. However, 2D ultrasound (US) imaging has limitations in evaluating the tumor coverage by imaging only one or multiple planes, particularly for cases with multiple inserted applicators or irregular tumor shapes. In this paper, we evaluate the intra-procedural tumor coverage using 3D US imaging and investigate whether it can provide clinically needed information. Using data from 14 cases, we employed surface- and volume-based evaluation metrics to provide information on any uncovered tumor region. For cases with incomplete tumor coverage or uneven ablation margin distribution, we also proposed a novel margin uniformity -based approach to provide quantitative applicator adjustment information for optimization of tumor coverage. Both the surface- and volume-based metrics showed that 5 of 14 cases had incomplete tumor coverage according to the estimated ablation zone. After applying our proposed applicator adjustment approach, the simulated results showed that 92.9% (13 of 14) cases achieved 100% tumor coverage and the remaining case can benefit by increasing the ablation time or power. Our proposed method can evaluate the intra-procedural tumor coverage and intuitively provide applicator adjustment information for the physician. Our 3D US-based method is compatible with the constraints of conventional US-guided ablation procedures and can be easily integrated into the clinical workflow.


Subject(s)
Catheter Ablation , Liver Neoplasms , Humans , Ultrasonography , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Imaging, Three-Dimensional/methods , Radionuclide Imaging , Catheter Ablation/methods
20.
Comput Math Methods Med ; 2022: 2014349, 2022.
Article in English | MEDLINE | ID: mdl-35509862

ABSTRACT

Atherosclerotic carotid plaques have been shown to be closely associated with the risk of stroke. Since patients with symptomatic carotid plaques have a greater risk for stroke, stroke risk stratification based on the classification of carotid plaques into symptomatic or asymptomatic types is crucial in diagnosis, treatment planning, and medical treatment monitoring. A deep learning technique would be a good choice for implementing classification. Usually, to acquire a high-accuracy classification, a specific network architecture needs to be designed for a given classification task. In this study, we propose an object-specific four-path network (OSFP-Net) for stroke risk assessment by integrating ultrasound carotid plaques in both transverse and longitudinal sections of the bilateral carotid arteries. Each path of the OSFP-Net comprises of a feature extraction subnetwork (FE) and a feature downsampling subnetwork (FD). The FEs in the four paths use the same network structure to automatically extract features from ultrasound images of carotid plaques. The FDs use different object-specific pooling strategies for feature downsampling based on the observation that the sizes and shapes in the feature maps obtained from FEs should be different. The object-specific pooling strategies enable the network to accept arbitrarily sized carotid plaques as input and to capture a more informative context for improving the classification accuracy. Extensive experimental studies on a clinical dataset consisting of 333 subjects with 1332 carotid plaques show the superiority of our OSFP-Net against several state-of-the-art deep learning-based methods. The experimental results demonstrate better clinical agreement between the ground truth and the prediction, which indicates its great potential for use as a risk stratification and as a monitoring tool in the management of patients at risk for stroke.


Subject(s)
Plaque, Atherosclerotic , Stroke , Carotid Arteries/diagnostic imaging , Humans , Plaque, Atherosclerotic/diagnostic imaging , Risk Assessment , Stroke/diagnostic imaging , Stroke/etiology , Ultrasonography