Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.000
Filter
1.
Phys Med Biol ; 68(14)2023 07 10.
Article in English | MEDLINE | ID: mdl-37343590

ABSTRACT

Objective. Megavoltage cone-beam computed tomography (MV-CBCT) imaging offers several advantages including reduced metal artifacts and accurate electron density mapping for adaptive or emergent situations. However, MV-CBCT imaging is limited by the poor efficiency of current detectors. Here we examine a new MV imager and compare CBCT reconstructions under clinically relevant scenarios.Approach. A multilayer imager (MLI), consisting of four vertically stacked standard flat-panel imagers, was mounted to a clinical linear accelerator. A custom anthropomorphic pelvis phantom with replaceable femoral heads was imaged using MV-CBCT and kilovoltage CBCT (kV-CBCT). Bone, aluminum, and titanium were used as femoral head inserts. 8 MU 2.5 MV scans were acquired for all four layers and (as reference) the top layer. Prostate and bladder were contoured on a reference CT and transferred to the other scans after rigid registration, from which the structural similarity index measure (SSIM) was calculated. Prostate and bladder were also contoured on CBCT scans without guidance, and Dice coefficients were compared to CT contours.Main results. kV-CBCT demonstrated the highest SSIMs with bone inserts (prostate: 0.86, bladder: 0.94) and lowest with titanium inserts (0.32, 0.37). Four-layer MV-CBCT SSIMs were preserved with bone (0.75, 0.80) as compared to titanium (0.67, 0.74), outperforming kV-CBCT when metal is present. One-layer MV-CBCT consistently underperformed four-layer results across all phantom configurations. Unilateral titanium inserts and bilateral aluminum insert results fell between the bone and bilateral titanium results. Dice coefficients trended similarly, with four-layer MV-CBCT reducing metal artifact impact relative to KV-CBCT to provide better soft-tissue identification.Significance. MV-CBCT with a four-layer MLI showed improvement over single-layer MV scans, approaching kV-CBCT quality for soft-tissue contrast. In the presence of artifact-producing metal implants, four-layer MV-CBCT scans outperformed kV-CBCT by eliminating artifacts and single-layer MV-CBCT by reducing noise. MV-CBCT with a novel multi-layer imager may be a valuable alternative to kV-CBCT, particularly in the presence of metal.


Subject(s)
Artifacts , Spiral Cone-Beam Computed Tomography , Titanium , Aluminum , Cone-Beam Computed Tomography/methods , Metals , Phantoms, Imaging
2.
Comput Methods Programs Biomed ; 225: 107063, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35994872

ABSTRACT

BACKGROUND AND OBJECTIVE: Wearable inertial devices integrated with modelling and cloud computing have been widely adopted in the sports sector, however, their use in the health and medical field has yet to be fully realised. To date, there have been no reported studies concerning the use of wearables as a surrogate tool to monitor knee joint loading during recovery following a total knee joint replacement. The objective of this study is to firstly evaluate if peak tibial acceleration from wearables during gait is a good surrogate metric for computer modelling predicted functional knee loading; and secondly evaluate if traditional clinical patient related outcomes measures are consistent with wearable predictions. METHODS: Following ethical approval, four healthy participants were used to establish the relationship between computer modelling predicted knee joint loading and wearable measured tibial acceleration. Following this, ten patients who had total knee joint replacements were then followed during their 6-week rehabilitation. Gait analysis, wearable acceleration, computer models of knee joint loading, and patient related outcomes measures including the Oxford knee score and range of motion were recorded. RESULTS: A linear correlation (R2 of 0.7-0.97) was observed between peak tibial acceleration (from wearables) and musculoskeletal model predicted knee joint loading during gait in healthy participants first. Whilst patient related outcome measures (Oxford knee score and patient range of motion) were observed to improve consistently during rehabilitation, this was not consistent with all patient's tibial acceleration. Only those patients that exhibited increasing peak tibial acceleration over 6-weeks rehabilitation were positively correlated with the Oxford knee score (R2 of 0.51 to 0.97). Wearable predicted tibial acceleration revealed three patients with a consistent knee loading, five patients with improving knee loading, and two patients with declining knee loading during recovery. Hence, 20% of patients did not present with satisfactory joint loading following total knee joint replacement and this was not detected with current patient related outcome measures. CONCLUSIONS: The use of inertial measurement units or wearables in this study provided additional insight into patients who were not exhibiting functional improvements in joint loading, and offers clinicians an 'off-site' early warning metric to identify potential complications during recovery and provide the opportunity for early intervention. This study has important implications for improving patient outcomes, equity, and for those who live in rural regions.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Wearable Electronic Devices , Arthroplasty, Replacement, Knee/rehabilitation , Biomechanical Phenomena , Gait , Humans , Knee Joint/surgery
3.
Parasitology ; 149(2): 161-170, 2022 02.
Article in English | MEDLINE | ID: mdl-35234595

ABSTRACT

Plasmodium coatneyi has been proposed as an animal model for human Plasmodium falciparum malaria as it appears to replicate many aspects of pathogenesis and clinical symptomology. As part of the ongoing evaluation of the rhesus macaque model of severe malaria, a detailed ultrastructural analysis of the interaction between the parasite and both the host erythrocytes and the microvasculature was undertaken. Tissue (brain, heart and kidney) from splenectomized rhesus macaques and blood from spleen-intact animals infected with P. coatneyi were examined by electron microscopy. In all three tissues, similar interactions (sequestration) between infected red blood cells (iRBC) and blood vessels were observed with evidence of rosette and auto-agglutinate formation. The iRBCs possessed caveolae similar to P. vivax and knob-like structures similar to P. falciparum. However, the knobs often appeared incompletely formed in the splenectomized animals in contrast to the intact knobs exhibited by spleen intact animals. Plasmodium coatneyi infection in the monkey replicates many of the ultrastructural features particularly associated with P. falciparum in humans and as such supports its use as a suitable animal model. However, the possible effect on host­parasite interactions and the pathogenesis of disease due to the use of splenectomized animals needs to be taken into consideration.


Subject(s)
Malaria , Plasmodium , Animals , Erythrocytes/parasitology , Host-Parasite Interactions , Macaca mulatta/parasitology , Malaria/parasitology
4.
Phys Med Biol ; 66(15)2021 07 20.
Article in English | MEDLINE | ID: mdl-34233309

ABSTRACT

Purpose.Electronic portal image devices (EPIDs) have been investigated previously for beams-eye view (BEV) applications such as tumor tracking but are limited by low contrast-to-noise ratio and detective quantum efficiency. A novel multilayer imager (MLI), consisting of four stacked flat-panels was used to measure improvements in fiducial tracking during liver stereotactic body radiation therapy (SBRT) procedures compared to a single layer EPID.Methods.The prototype MLI was installed on a clinical TrueBeam linac in place of the conventional DMI single-layer EPID. The panel was extended during volumetric modulated arc therapy SBRT treatments in order to passively acquire data during therapy. Images were acquired for six patients receiving SBRT to liver metastases over two fractions each, one with the MLI using all 4 layers and one with the MLI using the top layer only, representing a standard EPID. The acquired frames were processed by a previously published tracking algorithm modified to identify implanted radiopaque fiducials. Truth data was determined using respiratory traces combined with partial manual tracking. Results for 4- and 1-layer mode were compared against truth data for tracking accuracy and efficiency. Tracking and noise improvements as a function of gantry angle were determined.Results. Tracking efficiency with 4-layers improved to 82.8% versus 58.4% for the 1-layer mode, a relative improvement of 41.7%. Fiducial tracking with 1-layer returned a root mean square error (RMSE) of 2.1 mm compared to 4-layer RMSE of 1.5 mm, a statistically significant (p < 0.001) improvement of 0.6 mm. The reduction in noise correlated with an increase in successfully tracked frames (r = 0.913) and with increased tracking accuracy (0.927).Conclusion. Increases in MV photon detection efficiency by utilization of a MLI results in improved fiducial tracking for liver SBRT treatments. Future clinical applications utilizing BEV imaging may be enhanced by including similar noise reduction strategies.


Subject(s)
Particle Accelerators , Radiosurgery , Algorithms , Diagnostic Imaging , Fiducial Markers , Humans , Phantoms, Imaging
5.
Br J Surg ; 108(4): 388-394, 2021 04 30.
Article in English | MEDLINE | ID: mdl-33749771

ABSTRACT

BACKGROUND: Breast angiosarcomas are rare tumours of vascular origin. Secondary angiosarcoma occurs following radiotherapy for breast cancer. Angiosarcomas have high recurrence and poor survival rates. This is concerning owing to the increasing use of adjuvant radiotherapy for the treatment of invasive breast cancer and ductal cancer in situ (DCIS), which could explain the rising incidence of angiosarcoma. Outcome data are limited and provide a poor evidence base for treatment. This paper presents a national, trainee-led, retrospective, multicentre study of a large angiosarcoma cohort. METHODS: Data for patients with a diagnosis of breast/chest wall angiosarcoma between 2000 and 2015 were collected retrospectively from 15 centres. RESULTS: The cohort included 183 patients with 34 primary and 149 secondary angiosarcomas. Median latency from breast cancer to secondary angiosarcoma was 6 years. Only 78.9 per cent of patients were discussed at a sarcoma multidisciplinary team meeting. Rates of recurrence were high with 14 of 28 (50 per cent ) recurrences in patients with primary and 80 of 124 (64.5 per cent ) in those with secondary angiosarcoma at 5 years. Many patients had multiple recurrences: total of 94 recurrences in 162 patients (58.0 per cent). Median survival was 5 (range 0-16) years for patients with primary and 5 (0-15) years for those with secondary angiosarcoma. Development of secondary angiosarcoma had a negative impact on predicted breast cancer survival, with a median 10-year PREDICT prognostic rate of 69.6 per cent, compared with 54.0 per cent in the observed cohort. CONCLUSION: A detrimental impact of secondary angiosarcoma on breast cancer survival has been demonstrated. Although not statistically significant, almost all excess deaths were attributable to angiosarcoma. The increased use of adjuvant radiotherapy to treat low-risk breast cancer and DCIS is a cause for concern and warrants further study.


Subject(s)
Breast Neoplasms/secondary , Hemangiosarcoma/secondary , Neoplasm Recurrence, Local/epidemiology , Adult , Aged , Aged, 80 and over , Breast Neoplasms/epidemiology , Breast Neoplasms/mortality , Breast Neoplasms/pathology , Breast Neoplasms/therapy , Female , Hemangiosarcoma/epidemiology , Hemangiosarcoma/mortality , Hemangiosarcoma/therapy , Humans , Male , Middle Aged , Neoplasm Recurrence, Local/therapy , Retrospective Studies , Survival Analysis , Thoracic Wall/pathology , Treatment Outcome
6.
Ann R Coll Surg Engl ; 103(3): 173-179, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33557703

ABSTRACT

INTRODUCTION: With the emergence of the COVID-19 pandemic, all elective surgery was temporarily suspended in the UK, allowing for diversion of resource to manage the anticipated surge of critically unwell patients. Continuing to deliver time-critical surgical care is important to avoid excess morbidity and mortality from pathologies unrelated to COVID-19. We describe the implementation and short-term surgical outcomes from a system to deliver time-critical elective surgical care to patients during the COVID-19 pandemic. MATERIALS AND METHODS: A protocol for the prioritisation and safe delivery of time-critical surgery at a COVID-19 'clean' site was implemented at the Nuffield Health Exeter Hospital, an independent sector hospital in the southwest of England. Outcomes to 30 days postoperatively were recorded, including unplanned admissions after daycase surgery, readmissions and complications, as well as the incidence of perioperative COVID-19 infection in patients and staff. RESULTS: A total of 128 surgical procedures were performed during a 31-day period by a range of specialties including breast, plastics, urology, gynaecology, vascular and cardiology. There was one unplanned admission and and two readmissions. Six complications were identified, and all were Clavien-Dindo grade 1 or 2. All 128 patients had preoperative COVID-19 swabs, one of which was positive and the patient had their surgery delayed. Ten patients were tested for COVID-19 postoperatively, with none testing positive. CONCLUSION: This study has demonstrated the implementation of a safe system for delivery of time-critical elective surgical care at a COVID-19 clean site. Other healthcare providers may benefit from implementation of similar methodology as hospitals plan to restart elective surgery.


Subject(s)
Elective Surgical Procedures/methods , Neoplasms/surgery , Surgical Procedures, Operative/methods , Time-to-Treatment , Adolescent , Adult , Aged , Aged, 80 and over , Ambulatory Surgical Procedures/methods , Arteriovenous Shunt, Surgical , COVID-19 , COVID-19 Nucleic Acid Testing , Cardiac Catheterization , Delivery of Health Care/organization & administration , Female , Hospitalization/statistics & numerical data , Humans , Hysterectomy , Male , Mass Screening , Middle Aged , Patient Readmission/statistics & numerical data , Postoperative Complications/epidemiology , SARS-CoV-2 , United Kingdom/epidemiology , Urologic Surgical Procedures , Young Adult
7.
Abdom Radiol (NY) ; 46(2): 506-516, 2021 02.
Article in English | MEDLINE | ID: mdl-32761405

ABSTRACT

PURPOSE: Stool burden on abdominal radiographs is not reflective of constipation, perhaps because of variable fecal shadowing or limited inter-rater agreement. These limitations are hypothetically mitigated by computed tomography (CT). This research aimed (i) to evaluate whether bowel movement frequency, stool form, or a diagnosis of functional constipation correlate or associate with stool burden identified on CT, and (ii) to investigate whether physicians use CT in their assessment of a patients' bowel function. METHODS: Patients attending for non-emergent abdominal CT imaging were invited to participate by completing a bowel questionnaire. Stool burden identified on imaging was determined and inter-rater reliability was evaluated in a subgroup of patients (n = 20). Descriptive and comparative analyses were performed. An online questionnaire evaluated the use of abdominal imaging in assessing patients' bowel function in a cross-section of ordering physicians. RESULTS: The patient response rate was 19% (96/516). No clinically useful associations between fecal burden and stool form, bowel motion frequency, gastrointestinal symptoms or a diagnosis of constipation was identified. The physician response rate was 35% (33/94). Opportunistic use of data was more common than deliberate use. However, an abdominal radiograph or CT scan had been requested by 42% and 18% of physicians respectively to assess patient's chronic bowel habit. Approximately 30% of physicians believed evidence supported this practice. CONCLUSIONS: Physicians may use abdominal CT in their assessment of patients' chronic bowel habits. However, objective assessment does not support this practice. Colonic stool burden does not correlate with patient-reported symptoms or a criteria-based diagnosis of constipation.


Subject(s)
Defecation , Tomography, X-Ray Computed , Cross-Sectional Studies , Habits , Humans , Reproducibility of Results
8.
Phys Med Biol ; 65(22): 225004, 2020 12 07.
Article in English | MEDLINE | ID: mdl-33284786

ABSTRACT

Electronic portal imaging devices (EPIDs) lend themselves to beams-eye view clinical applications, such as tumor tracking, but are limited by low contrast and detective quantum efficiency (DQE). We characterize a novel EPID prototype consisting of multiple layers and investigate its suitability for use under clinical conditions. A prototype multi-layer imager (MLI) was constructed utilizing four conventional EPID layers, each consisting of a copper plate, a Gd2O2S:Tb phosphor scintillator, and an amorphous silicon flat panel array detector. We measured the detector's response to a 6 MV photon beam with regards to modulation transfer function, noise power spectrum, DQE, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and the linearity of the detector's response to dose. Additionally, we compared MLI performance to the single top layer of the MLI and the standard Varian AS-1200 detector. Pre-clinical imaging was done on an anthropomorphic phantom, and the detector's CNR, SNR and spatial resolution were assessed in a clinical environment. Images obtained from spine and liver patient treatment deliveries were analyzed to verify CNR and SNR improvements. The MLI has a DQE(0) of 9.7%, about 5.7 times the reference AS-1200 detector. Improved noise performance largely drives the increase. CNR and SNR of clinical images improved three-fold compared to reference. A novel MLI was characterized and prepared for clinical translation. The MLI substantially improved DQE and CNR performance while maintaining the same resolution. Pre-clinical tests on an anthropomorphic phantom demonstrated improved performance as predicted theoretically. Preliminary patient data were analyzed, confirming improved CNR and SNR. Clinical applications are anticipated to include more accurate soft tissue tracking.


Subject(s)
Diagnostic Imaging/instrumentation , Electrical Equipment and Supplies , Humans , Phantoms, Imaging , Signal-To-Noise Ratio , Translational Research, Biomedical
9.
Expert Rev Cardiovasc Ther ; 18(7): 381-394, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32538199

ABSTRACT

INTRODUCTION: Blood lipid screening recommendations begin at ages 9-11 years, despite poor adherence and evidence of fatty streaks in coronary arteries by 3 years of age. For cardiovascular disease (CVD) prevention, there may be value in earlier measurement of blood lipids. AREAS COVERED: The present systematic review examines evidence concerning total cholesterol, low-density lipoprotein, high-density lipoprotein, and triglycerides during the infant period. Included are studies examining the extent to which infant blood lipids predict later values in childhood and factors that influence their magnitude. A total of 38 articles (published from 1965 to 2013) met inclusion criteria and were examined in this review. EXPERT OPINION: Longitudinal data suggest correlative relationships in all lipid values around 6 months of age, except for TRG. Influential factors related to blood lipids in infancy include sex, race, family history, feeding, gestational length, birth weight, and maternal factors. Clinical measurement of infant lipids could perhaps provide an early marker of CVD and a target of early CVD prevention strategies. The identification of personal characteristics that associate with high or low values in each lipid could become important in the early identification of vulnerable populations and the promotion of personalized CVD prevention.


Subject(s)
Cardiovascular Diseases/prevention & control , Lipids/blood , Child , Child, Preschool , Cholesterol/blood , Humans , Infant , Risk Factors , Triglycerides/blood
10.
Phys Med Biol ; 65(12): 125011, 2020 06 22.
Article in English | MEDLINE | ID: mdl-32330918

ABSTRACT

Tumor tracking during radiotherapy treatment can improve dose accuracy, conformity and sparing of healthy tissue. Many methods have been introduced to tackle this challenge utilizing multiple imaging modalities, including a template matching based approach using the megavoltage (MV) on-board portal imager demonstrated on 3D conformal treatments. However, the complexity of treatments is evolving with the introduction of VMAT and IMRT, and successful motion management is becoming more important due to a trend towards hypofractionation. We have developed a markerless lung tumor tracking algorithm, utilizing the electronic portal imager (EPID) of the treatment machine. The algorithm has been specifically adapted to track during complex treatment deliveries with gantry and MLC motion. The core of the algorithm is an adaptive template matching method that relies on template stability metrics and local relative orientations to perform multiple feature tracking simultaneously. Only a single image is required to initialize the algorithm and features are automatically added, modified or removed in response to the input images. This algorithm was evaluated against images collected during VMAT arcs of a dynamic thorax phantom. Dynamic phantom images were collected during radiation delivery for multiple lung SBRT breathing traces and an example patient data set. The tracking error was 1.34 mm for the phantom data and 0.68 mm for the patient data. A multi-region, markerless tracking algorithm has been developed, capable of tracking multiple features simultaneously without requiring any other a priori information. This novel approach delivers robust target localization during complex treatment delivery. The reported tracking error is similar to previous reports for 3D conformal treatments.


Subject(s)
Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods , Algorithms , Automation , Humans , Image Processing, Computer-Assisted , Movement , Phantoms, Imaging
11.
J Plast Reconstr Aesthet Surg ; 73(6): 1043-1049, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32008945

ABSTRACT

INTRODUCTION: Immediate implant-based breast reconstruction (IBR) rates have increased considerably with the advent of acellular dermal matrices. Implant loss is a significant complication and is costly to patients and the NHS. National Mastectomy and Breast Reconstruction Audit and Implant-Based Breast Reconstruction Audit data have demonstrated national implant loss rate of 9% at 3 months. National Oncoplastic Guidelines for Best Practice cite a < 5% target. We aimed to reduce implant loss by introducing a protocol with pre-, intra- and post-operative interventions. METHODS: Audit of IBR at a single oncoplastic breast unit was commenced and implant loss at 3 months was recorded (May 2012-July 2014). Patients were identified from a prospectively maintained database, and case notes were examined by identifying factors associated with implant loss. A team involving microbiology, theatre staff, infection control and surgeons was established. A novel, evidence-based intervention bundle, including more than 25 protocol changes, was introduced. Prospective re-audit of IBR (April 2015-December 2017) was completed following introduction of the new protocol and implant loss was recorded at 3 months. RESULTS: The first retrospective audit of 77 reconstructions (54 patients) demonstrated 11 implant losses at 3 months (14%). Re-audit, post-intervention, comprised 129 reconstructions (106 patients) with no implant loss at 3 months. Fisher's exact analysis revealed statistically significant reduction in implant loss rate (P < 0.00001) following protocol introduction. CONCLUSIONS: Implant loss rate following IBR can be reduced to an exceptionally low level, well below national targets, by adhering to this evidence-based intervention bundle. Our protocol could improve outcomes nationally.


Subject(s)
Breast Implantation/methods , Clinical Protocols , Quality Assurance, Health Care/methods , Adult , Breast Implantation/adverse effects , Breast Implantation/standards , Breast Implants/adverse effects , Breast Neoplasms/surgery , Female , Humans , Medical Audit , Middle Aged , Prosthesis Failure , Quality Improvement , Retrospective Studies , Risk Factors
12.
Res Q Exerc Sport ; 91(4): 562-573, 2020 Dec.
Article in English | MEDLINE | ID: mdl-31976825

ABSTRACT

Purpose:Automobile racing is physically challenging, but there is no information related to experience level and physiological responses to racing. The aim of this study was to compare physiological responses of professional (PRO) and amateur (AM) sportscar drivers. Methods:Four male racing drivers (PRO n = 2, AM n = 2), completed a physical fitness assessment and had heart rate (HR), breathing rate 10 (BR), skin temperature (Tsk), core temperature (Tcore), physiological strain index (PSI) and blood glucose (BG) measured continuously during six races. Rate of perceived exertion (RPE), blood lactate, and fluid loss were measured post-race. Results:AM had higher HR compared to PRO during driver changes (AM: 177 ± 12 beats·min-1, PRO: 141 ± 16 beats·min-1, p < .0001), pit stops (AM: 139 ± 14 beats·min-1, PRO: 122 ± 1 beats·min-1, p = .0381) and cautions (AM: 144 ± 13 beats·min-1, PRO: 15 123 ± 11 beats·min-1, p = .0059). During pit stops, PRO (26 ± 6 respirations·min-1) displayed a significantly greater BR than AM (AM: 18 ± 7 respirations·min-1, p = .0004). Tcore was greater for PRO (38.4 ± 0.4°C) drivers while in the car during pit stops than AM (36.1 ± 2.5°C, p < .0001). AM displayed elevated PSI during cautions (AM: 5.5 ± 1.8, PRO: 3.2 ± 1.3, p < .0001) and pit stops (AM: 5.6 ± 1.4, PRO: 2.8 ± 1.1, p < .0001). BG was increased for AM versus PRO during pit stops (AM: 20 132.9 ± 20.2 mg·dl-1, PRO: 106.5 ± 3.5 mg·dl-1, p = .0015) and during racing (AM: 150.9 ± 34.6 mg·dl-1, PRO: 124.9 ± 16.0 mg·dl-1, p = .0018). AM (3.3 ± 1.7 mmol·dl-1) had a higher blood lactate than PRO (1.7 ± 2.6 mmol·dl-1, p = .0491) from pre to post-race. AM (1.90 ± 0.54 kg) lost more fluids over the race than PRO (1.36 ± 0.67 kg, p = .0271). Conclusions:Amateur drivers could fatigue faster in the car which results in a decreased driving performance.


Subject(s)
Automobiles , Competitive Behavior/physiology , Sports/physiology , Adult , Blood Glucose/metabolism , Body Temperature Regulation , Fatigue/physiopathology , Heart Rate , Humans , Lactic Acid/blood , Male , Perception/physiology , Physical Exertion/physiology , Physical Fitness , Respiratory Rate , Skin Temperature , Sports/psychology , Stress, Physiological , Stress, Psychological , Young Adult
13.
Br J Dermatol ; 182(3): 698-707, 2020 03.
Article in English | MEDLINE | ID: mdl-31141158

ABSTRACT

BACKGROUND: The Ehlers-Danlos syndromes (EDS) consist of 13 subtypes with overlapping features including joint hypermobility, skin and vascular fragility and generalized connective tissue friability. As DNA analysis has become the gold standard for investigation of EDS, transmission electron microscopy (TEM) in clinical practice is decreasing. However, owing to the use of next-generation sequencing, the frequency of variants of uncertain significance (VUS) identified using DNA analysis is increasing. We hypothesized that TEM can provide evidence for or against pathogenicity of VUS. OBJECTIVES: The aim of this study was to evaluate the role of TEM in the diagnosis of EDS subtypes. METHODS: Data were collected from patients who underwent a skin biopsy between October 2012 and March 2017 at the London EDS National Diagnostic Service. TEM biopsies were categorized as 'normal' or 'abnormal' according to the description and conclusion in the TEM reports. Definitive diagnoses were reached via a combination of clinical features, structural and functional studies and DNA investigations. RESULTS: The analysis included 177 patients, comprising 30 abnormal and 147 normal TEM reports. A definitive diagnosis of monogenic EDS subtypes was made in 24 patients. Overall, 17 of these 24 patients (71%) had an abnormal biopsy report and seven (29%) had a normal biopsy report. No TEM findings were specifically associated with any EDS subtype, although collagen flowers were present in most patients with a genetically confirmed diagnosis of classical EDS. CONCLUSIONS: TEM analysis of collagen structure may have the potential to provide evidence for or against the pathogenicity of a VUS, but more work is needed to establish a clear role for TEM in this process. What's already known about this topic? Collagen fibril abnormalities can be seen in several Ehlers-Danlos syndrome (EDS) subtypes. What does this study add? This study provides clinical data, transmission electron microscopy (TEM) data and molecular data of one of the largest groups of patients suspected to have a monogenetic EDS subtype. No TEM findings were specifically associated with an EDS subtype. There was a higher percentage (71%) of abnormal biopsy findings in patients with a definitive diagnosis of a monogenetic EDS subtype and where a class 4/5 genetic variant was present.


Subject(s)
Ehlers-Danlos Syndrome , Collagen , Ehlers-Danlos Syndrome/diagnosis , Ehlers-Danlos Syndrome/genetics , Humans , London , Microscopy, Electron , Syndrome
14.
Zootaxa ; 4646(2): zootaxa.4646.2.8, 2019 Jul 24.
Article in English | MEDLINE | ID: mdl-31717019

ABSTRACT

Anabarhynchus Macquart 1848 is a species-rich genus of stiletto flies (Diptera: Therevidae) belonging to the subfamily Therevinae, with over 113 species described from Australia. These flies are diverse and abundant in Australia's eucalypt woodland and mallee habitats. Here we describe, diagnose and illustrate a further three new Anabarhynchus species in the genus as follows: A. aurantilateralis sp. nov. and A. halmaturinus sp. nov., and A. venabrunneis sp. nov., from Kangaroo Island. These new species bring the total number of described Australian species in the genus to 116, with 13 of these known to occur on Kangaroo Island.


Subject(s)
Diptera , Animal Distribution , Animals , Australia , Ecosystem , Islands , South Australia
16.
Sci Rep ; 9(1): 8674, 2019 06 17.
Article in English | MEDLINE | ID: mdl-31209240

ABSTRACT

FcRn mediates recycling and transcytosis of IgG and albumin in various cell types. The MHC-class-I-like protein of the FcRn heterodimer is encoded by FCGRT. Few determinants of variable FCGRT expression in humans have been identified so far. In this study, we investigated the presence of DNA methylation in regulatory regions of FCGRT in samples of human liver and myocardium tissue, and we examined the impact of FCGRT methylation on FcRn expression in model cell lines. Quantitative DNA methylation analysis of the FCGRT locus revealed differentially methylated regions in DNA from liver and myocardium. Methylation status in individual CpG sites correlated with FCGRT mRNA expression. Data from model cell lines suggest that differential methylation in the -1058 to -587 bp regulatory region of FCGRT contributes to FcRn expression. Chromatin immunoprecipitation assays indicate that CpG site methylation impacts the binding of the methylation sensitive transcription factors Zbtb7a and Sp1. This study provides a foundation to further define the contribution of epigenetic factors during the control of FcRn expression and IgG traffic in human tissues.


Subject(s)
DNA-Binding Proteins/genetics , Epigenesis, Genetic , Hepatocytes/metabolism , Histocompatibility Antigens Class I/genetics , Myocytes, Cardiac/metabolism , Receptors, Fc/genetics , Sp1 Transcription Factor/genetics , Transcription Factors/genetics , Albumins/metabolism , Cell Line, Tumor , Chromatin Immunoprecipitation , CpG Islands , DNA Methylation , DNA-Binding Proteins/metabolism , Hepatocytes/cytology , Histocompatibility Antigens Class I/metabolism , Humans , Immunoglobulin G/metabolism , Liver/cytology , Liver/metabolism , Myocardium/cytology , Myocardium/metabolism , Myocytes, Cardiac/cytology , Promoter Regions, Genetic , Protein Binding , RNA, Messenger/genetics , RNA, Messenger/metabolism , Receptors, Fc/metabolism , Sp1 Transcription Factor/metabolism , Transcription Factors/metabolism , Transcytosis/genetics
17.
Eur J Orthop Surg Traumatol ; 29(6): 1277-1289, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31093753

ABSTRACT

BACKGROUND: Anterior cruciate ligament (ACL) reconstruction is a rapidly developing orthopaedic field and an area of notable clinical equipoise. The optimal timing of surgery in an acute (< 3 weeks) or delayed (≥ 3 weeks) time frame remains unresolved with a 2010 meta-analysis concluding no difference between these two groups across multiple outcomes. In an era of evidence-based medicine, surgeons are still basing their decisions on when to operate on little more than anecdotal evidence and personal preference. Clear guidance is required to determine whether the timing of surgery can optimise outcomes in this largely young and active patient cohort. METHODS: A systematic literature search was performed in January 2018 of Embase, Medline and OpenGrey in accordance with (PRISMA) guidelines. A total of 658 articles were retrieved, with 6 suitable for inclusion, covering 576 ACL reconstructions. Four meta-analyses were performed assessing subjective measures of Tegner activity scale and Lysholm score, and objective measures of arthroscopically identified meniscal and chondral injury. Additional relevant outcome measures underwent narrative review. Study bias was assessed and reported using the Downs and Black checklist. RESULTS: A statistically significant difference of 0.39 points was found on the Tegner activity scale in favour of early surgery within 3 weeks (RR 0.39, CI 0.10, 0.67, p = 0.008). No statistically difference was found between groups for the patient-reported Lysholm score (RR - 0.18, CI - 2.40, 2.05, p = 0.17). There was no statistically significant difference between groups for intra-operative findings of meniscal lesions (RR 0.84, CI 0.66, 1.08, p = 0.17). A trend towards significance was observed for the incidence of chondral lesions in the early surgery group (RR 0.56, CI 0.31, 1.02, p = 0.06). All the studies were rated either fair or good on the Downs and Black checklist with no study excluded due to bias. CONCLUSIONS: Although there was a statistically significant result for the Tegner activity scale in favour of early surgery, the magnitude of the effect is unlikely to translate into any clinically meaningful difference. At present, there remains no clear evidence to determine superiority of acute/early or delayed reconstruction of a ruptured anterior cruciate ligament. Further research through methodologically robust randomised controlled trials or through the UK National Ligament Registry  may help to provide clearer guidance.


Subject(s)
Anterior Cruciate Ligament Reconstruction/methods , Time-to-Treatment , Anterior Cruciate Ligament Injuries/surgery , Evidence-Based Practice , Humans
18.
Int J Stroke ; 13(9): 949-984, 2018 12.
Article in English | MEDLINE | ID: mdl-30021503

ABSTRACT

The 2018 update of the Canadian Stroke Best Practice Recommendations for Acute Stroke Management, 6th edition, is a comprehensive summary of current evidence-based recommendations, appropriate for use by healthcare providers and system planners caring for persons with very recent symptoms of acute stroke or transient ischemic attack. The recommendations are intended for use by a interdisciplinary team of clinicians across a wide range of settings and highlight key elements involved in prehospital and Emergency Department care, acute treatments for ischemic stroke, and acute inpatient care. The most notable changes included in this 6th edition are the renaming of the module and its integration of the formerly separate modules on prehospital and emergency care and acute inpatient stroke care. The new module, Acute Stroke Management: Prehospital, Emergency Department, and Acute Inpatient Stroke Care is now a single, comprehensive module addressing the most important aspects of acute stroke care delivery. Other notable changes include the removal of two sections related to the emergency management of intracerebral hemorrhage and subarachnoid hemorrhage. These topics are covered in a new, dedicated module, to be released later this year. The most significant recommendation updates are for neuroimaging; the extension of the time window for endovascular thrombectomy treatment out to 24 h; considerations for treating a highly selected group of people with stroke of unknown time of onset; and recommendations for dual antiplatelet therapy for a limited duration after acute minor ischemic stroke and transient ischemic attack. This module also emphasizes the need for increased public and healthcare provider's recognition of the signs of stroke and immediate actions to take; the important expanding role of paramedics and all emergency medical services personnel; arriving at a stroke-enabled Emergency Department without delay; and launching local healthcare institution code stroke protocols. Revisions have also been made to the recommendations for the triage and assessment of risk of recurrent stroke after transient ischemic attack/minor stroke and suggested urgency levels for investigations and initiation of management strategies. The goal of this updated guideline is to optimize stroke care across Canada, by reducing practice variations and reducing the gap between current knowledge and clinical practice.


Subject(s)
Emergency Medical Services/legislation & jurisprudence , Emergency Service, Hospital/legislation & jurisprudence , Ischemic Attack, Transient/therapy , Stroke/therapy , Canada , Critical Care/legislation & jurisprudence , Delivery of Health Care/legislation & jurisprudence , Hospitalization/legislation & jurisprudence , Humans , Inpatients , Stroke/diagnosis
19.
J Dev Orig Health Dis ; 9(4): 417-424, 2018 08.
Article in English | MEDLINE | ID: mdl-29644942

ABSTRACT

Growth restriction caused by postnatal undernutrition increases risk for cardiovascular disease in adulthood with the potential to induce arrhythmogenesis. Thus, the purpose was to determine if undernutrition during development produced arrhythmias at rest and when stressed with dobutamine in adulthood. Mouse dams were fed (CON: 20% protein), or low-protein (LP: 8%) diet before mating. A cross-fostering model was used where pups nursed by dams fed LP diet in early [EUN; postnatal day (PN) 1-10], late (LUN; PN11-21) and whole (PUN; 1-21) phases of postnatal life. Weaned pups were switched to CON diets for the remainder of the study (PN80). At PN80, body composition (magnetic resonance imaging), and quantitative electrocardiogram (ECG) measurements were obtained under 1% isoflurane anesthesia. After baseline ECG, an IP injection (1.5 µg/g body weight) of dobutamine was administered and ECG repeated. Undernutrition significantly (P<0.05) reduced body weight in LUN (22.68±0.88 g) and PUN (19.96±0.32 g) but not in CON (25.05±0.96 g) and EUN (25.28±0.9207 g). Fat mass decreased in all groups compared with controls (CON: 8.00±1.2 g, EUN: 6.32±0.65 g, LUN: 5.11±1.1 g, PUN: 3.90±0.25 g). Lean mass was only significantly reduced in PUN (CON: 17.99±0.26 g, EUN: 17.78±0.39 g, LUN: 17.34±0.33 g, PUN: 15.85±0.28 g). Absolute heart weights were significantly less from CON, with PUN having the smallest. ECG showed LUN had occurrences of atrial fibrillation; EUN had increases of 1st degree atrioventricular block upon stimulation, and PUN had increased risk for ventricular depolarization arrhythmias. CON did not display arrhythmias. Undernutrition in early life resulted in ventricular arrhythmias under stressed conditions, but undernutrition occurring in later postnatal life there is an increased incidence of atrial arrhythmias.


Subject(s)
Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/pathology , Diet, Protein-Restricted/adverse effects , Dobutamine/toxicity , Malnutrition/complications , Stress, Physiological , Animals , Animals, Newborn , Cardiotonic Agents/toxicity , Female , Male , Mice
20.
J Dev Orig Health Dis ; 9(3): 299-306, 2018 06.
Article in English | MEDLINE | ID: mdl-29310734

ABSTRACT

Several studies have suggested that maternal lifestyle during pregnancy may influence long-term health of offspring by altering the offspring epigenome. Whether maternal leisure-time physical activity (LTPA) during pregnancy might have this effect is unknown. The purpose of this study was to determine the relationship between maternal LTPA during pregnancy and offspring DNA methylation. Participants were recruited from the Archive for Research on Child Health study. At enrollment, participants' demographic information and self-reported LTPA during pregnancy were determined. High active participants (averaged 637.5 min per week of LTPA; n=14) were matched by age and race to low active participants (averaged 59.5 min per week LTPA; n=28). Blood spots were obtained at birth. Pyrosequencing was used to determine methylation levels of long interspersed nucleotide elements (LINE-1) (global methylation) and peroxisome proliferator-activated receptor-gamma (PPARγ), peroxisome proliferator-activated receptor-gamma coactivator (PGC1-α), insulin-like growth factor 2 (IGF2), pyruvate dehydrogenase kinase, isozyme 4 (PDK4) and transcription factor 7-like 2 (TCF7L2). We found no differences between offspring of high active and low active groups for LINE-1 methylation. The only differences in candidate gene methylation between groups were at two CpG sites in the P2 promoter of IGF2; the offspring of low active group had significantly higher DNA methylation (74.70±2.25% methylation for low active v. 72.83±2.85% methylation for high active; P=0.045). Our results suggest no effect of maternal LTPA on offspring global and candidate gene methylation, with the exception of IGF2. IGF2 has been previously associated with regulation of physical activity, suggesting a possible role of maternal LTPA on regulation of offspring physical activity.


Subject(s)
DNA Methylation , Exercise/physiology , Insulin-Like Growth Factor II/genetics , Motor Activity/physiology , Adult , Cohort Studies , Female , Humans , Infant, Newborn , Male , Pregnancy
SELECTION OF CITATIONS
SEARCH DETAIL
...